UCD9248 www.ti.com SLVSA33 – JANUARY 2010 Digital PWM System Controller FEATURES Tool to Simulate, Configure, and Monitor Power Supply Performance 1 • 2 • • • • • • • • • • • • • • • • Fully Configurable Multi-Output and MultiPhase Non-Isolated DC/DC PWM Controller Controls Up to 4 Voltage Rails and Up to 8 Phases Supports Switching Frequencies Up to 2MHz with 250 ps Duty-Cycle Resolution Up To 1mV Closed Loop Resolution Hardware-Accelerated, 3-Pole/3-Zero Compensator with Non-Linear Gain for Improved Transient Performance Supports Multiple Soft-Start and Soft-Stop Configurations Including Prebias Start-up Supports Voltage Tracking, Margining and Sequencing Supports Current and Temperature Balancing for Multi-Phase Power Stages Supports Phase Adding/Shedding for Multi-Phase Power Stages Sync In/Out Pins Align DPWM Clocks Between Multiple UCD92xx Devices 12-Bit Digital Monitoring of Power Supply Parameters Including: – Input/Output Current and Voltage – Temperature at Each Power Stage Multiple Levels of Over-current Fault Protection: – External Current Fault Inputs – Analog Comparators Monitor Current Sense Voltage – Current Continually Digitally Monitored Over- and Under-voltage Fault Protection Over-temperature Fault Protection Enhanced Nonvolatile Memory with Error Correction Code (ECC) Device Operates From a Single Supply with an Internal Regulator Controller That Allows Operation Over a Wide Supply Voltage Range Supported by Fusion Digital Power™ Designer, a Full Featured PC Based Design APPLICATIONS • • • • • • Industrial/ATE Networking Equipment Telecommunications Equipment Servers Storage Systems FPGA, DSP and Memory Power DESCRIPTION The UCD9248 is a multi-rail, multi-phase synchronous buck digital PWM controller designed for non-isolated DC/DC power applications. This device integrates dedicated circuitry for DC/DC loop management with flash memory and a serial interface to support configurability, monitoring and management. The UCD9248 was designed to provide a wide variety of desirable features for non-isolated DC/DC converter applications while minimizing the total system component count by reducing external circuits. The solution integrates multi-loop management with sequencing, margining, tracking and intelligent phase management to optimize for total system efficiency. Additionally, loop compensation and calibration are supported without the need to add external components. To facilitate configuring the device, the Texas Instruments Fusion Digital Power™ Designer is provided. This PC based Graphical User Interface offers an intuitive interface to the device. This tool allows the design engineer to configure the system operating parameters for the application, store the configuration to on-chip non-volatile memory and observe both frequency domain and time domain simulations for each of the power stage outputs. TI has also developed multiple complementary power stage solutions – from discrete drivers in the UCD7k family to fully tested power train modules in the PTD family. These solutions have been developed to complement the UCD9k family of system power controllers. 1 2 Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. Fusion Digital Power, Auto-ID are trademarks of Texas Instruments. PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of the Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. Copyright © 2010, Texas Instruments Incorporated UCD9248 SLVSA33 – JANUARY 2010 www.ti.com This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications. ORDERING INFORMATION (1) OPERATING TEMPERATURE RANGE, TA ORDERABLE PART NUMBER PIN COUNT SUPPLY PACKAGE TOP SIDE MARKING UCD9248PFCR 80-pin Reel of 1000 QFP UCD9248 UCD9248PFC 80-pin Tray of 119 QFP UCD9248 –40°C to 125°C (1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI web site at www.ti.com. ABSOLUTE MAXIMUM RATINGS (1) VALUE UNIT Voltage applied at V33D to DGND –0.3 to 3.8 V Voltage applied at V33A to AGND –0.3 to 3.8 V Voltage applied to any pin (2) –0.3 to 3.8 V Storage temperature (TSTG) –40 to 150 °C (1) (2) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. All voltages referenced to GND. RECOMMENDED OPERATING CONDITIONS over operating free-air temperature range (unless otherwise noted) V Supply voltage during operation, V33D, V33DIO, V33A TA Operating free-air temperature range (1) TJ Junction temperature (1) MIN NOM 3 3.3 MAX UNIT 3.6 V 125 °C 125 °C TYP MAX UNIT –40 (1) When operating, the UCD9248’s typical power consumption causes a 15°C temperature rise from ambient. ELECTRICAL CHARACTERISTICS PARAMETER TEST CONDITIONS MIN SUPPLY CURRENT IV33A V33A = 3.3 V 8 15 IV33DIO V33DIO = 3.3 V 2 10 V33D = 3.3 V 40 45 V33D = 3.3 V storing configuration parameters in flash memory 50 55 3.3 3.6 4 4.6 IV33D Supply current IV33D mA INTERNAL REGULATOR CONTROLLER INPUTS/OUTPUTS V33 3.3-V linear regulator V33FB 3.3-V linear regulator feedback IV33FB Series pass base drive Beta Series NPN pass device Emitter of NPN transistor 3.25 VVIN = 12 V 10 V mA 40 EXTERNALLY SUPPLIED 3.3 V POWER V33D Digital 3.3-V power TA = 25° C 3.0 3.6 V V33A Analog 3.3-V power TA = 25°C 3.0 3.6 V 2 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated UCD9248 www.ti.com SLVSA33 – JANUARY 2010 ELECTRICAL CHARACTERISTICS (continued) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT ERROR AMPLIFIER INPUTS EAPn, EANn VCM Common mode voltage each pin VERROR Internal error voltage range AFE_GAIN field of CLA_GAINS = 0 (1) –0.15 1.848 –256 248 mV EAP-EAN Error voltage digital resolution AFE_GAIN field of CLA_GAINS= 3 REA Input Impedance Ground reference 0.5 IOFFSET Input offset current 1 kΩ source impedence –5 V 3 MΩ 5 µA 1 1.5 mV Vref 10-bit DAC Vref Reference voltage setpoint Vrefres Reference voltage resolution 0 1.6 V 1.56 mV ANALOG INPUTS CS-1A, CS-1B, CS-2A, CS-2B, CS-3A, CS-3B, CS-4A, CS-4B, Vin/Iin, TEMP, ADDR-0, ADDR-1, Vtrack, ADCref VADDR_OPEN Voltage indicating open pin ADDR-0, ADDR-1 open VADDR_SHORT Voltage indicating shorted pin ADDR-0, ADDR-1 short to ground 2.37 VADC_RANGE Measurement range for voltage monitoring Inputs: Vin/Iin, Vtrack, Temp, CS-1A, CS-1B, CS-2A, CS-2B CS-3A, CS-3B, CS-4A, CS-4B VOC_THRS Over-current comparator threshold voltage range (2) Inputs: CS-1A, CS-2A, CS-3A, CS-4A VOC_RES Over-current comparator threshold voltage range Inputs: CS-1A, CS-2A, CS-3A, CS-4A ADCref External reference input Tempinternal Int. temperature sense accuracy INL ADC integral nonlinearity Ilkg Input leakage current 3V applied to pin RIN Input impedance Ground reference CIN Current Sense Input capacitance V 0.36 V 0 2.5 V 0.032 2 V 31.25 Over range from 0°C to 125°C mV 1.8 V33A V –5 5 °C 2.5 mV –2.5 100 nA 8 MΩ 10 pF Dgnd +0.25 V DIGITAL INPUTS/OUTPUTS VOL Low-level output voltage IOL = 6 mA (3), V33DIO = 3 V VOH High-level output voltage IOH = -6 mA (4), V33DIO = 3 V VIH High-level input voltage V33DIO = 3V VIL Low-level input voltage V33DIO = 3.5 V V33DIO –0.6V 2.1 V 3.6 V 1.4 V SYSTEM PERFORMANCE VRESET Voltage where device comes out of reset V33D Pin tRESET Pulse width needed for reset nRESET pin VRefAcc Setpoint reference accuracy Vref commanded to be 1V, at 25°C, AFEgain = 4, 1V input to EAP/N measured at output of the EADC (5) 2.3 Setpoint reference accuracy over temperature –40°C to 125°C VDiffOffset Differential offset between gain settings 2.4 V 2 AFEgain = 4 compared to AFEgain = 1, 2, or 8 µs –10 10 mV –20 20 mV –4 4 mV 240 240 + 1 switching cycle ns tDelay Digital compensator delay FSW Switching frequency Duty Max and Min duty cycle V33Slew Minimum V33 slew rate during power on V33 slew rate between 2.3V and 2.9V 0.25 V/ms tretention Retention of configuration parameters TJ = 25°C 100 Years Write_Cycles Number of nonvolatile erase/write cycles TJ = 25°C 20 K cycles (1) (2) (3) (4) (5) 15.260 2000 0% 100% kHz See the UCD92xx PMBus Command Reference for the description of the AFE_GAIN field of CLA_GAINS command. Can be disabled by setting to '0' The maximum IOL, for all outputs combined, should not exceed 12 mA to hold the maximum voltage drop specified. The maximum IOH, for all outputs combined, should not exceed 48 mA to hold the maximum voltage drop specified. With default device calibration. PMBus calibration can be used to improve the regulation tolerance Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 3 UCD9248 SLVSA33 – JANUARY 2010 www.ti.com ADC MONITORING INTERVALS AND RESPONSE TIMES The ADC operates in a continuous conversion sequence that measures each rail's output voltage, each power stage's output current, plus four other variables (external temperature, Internal temperature, input voltage and current, and tracking input voltage). The length of the sequence is determined by the number of output rails (NumRails) and total output power stages (NumPhases) configured for use. The time to complete the monitoring sampling sequence is give by the formula: tADC_SEQ = tADC × (NumRAILS + NumPHASE + 4) PARAMETER tADC TEST CONDITIONS MIN ADC single-sample time tADC_SEQ ADC sequencer interval TYP MAX 3.84 Min = 1 Rail + 1 Phase + 4 = 6 samples Max = 4 Rails + 8 Phases + 4 = 16 samples 23.04 UNIT µs 61.44 µs The most recent ADC conversion results are periodically converted into the proper measurement units (volts, amperes, degrees), and each measurement is compared to its corresponding fault and warning limits. The monitoring operates asynchronously to the ADC, at intervals shown in the table below. PARAMETER TEST CONDITIONS MIN TYP MAX UNIT tVout Output voltage monitoring interval 200 tIout Output current monitoring interval 200 × NRails µs µs tVin Input voltage monitoring interval 2 ms tIin Input current monitoring interval 2 ms tTEMP Temperature monitoring interval 100 ms tIbal Output current balancing interval 2 ms Because the ADC sequencer and the monitoring comparisons are asynchronous to each other, the response time to a fault condition depends on where the event occurs within the monitoring interval and within the ADC sequence interval. Once a fault condition is detected, some additional time is required to determine the correct action based on the FAULT_RESPONSE code, and then to perform the appropriate response. The following table lists the worse-case fault response times. PARAMETER tOVF, tUVF tOCF, tUCF tOTF (1) 4 MAX TIME UNIT Over-/under-voltage fault response time during normal operation Normal regulation, no PMBus activity, 8 stages enabled TEST CONDITIONS 300 µs Over-/under-voltage fault response time, during data logging During data logging to nonvolatile memory (1) 800 µs Over-/under-voltage fault response time, when tracking or sequencing enable During tracking and soft-start ramp. 400 µs Over-/under-current fault response time during normal operation Normal regulation, no PMBus activity, 8 stages enabled 75% to 125% current step 100 + (600 × NRails) µs Over-/under-current fault response time, during data logging During data logging to nonvolatile memory 75% to 125% current step 600 + (600 × NRails) µs Over-/under-current fault response time, when tracking or sequencing enable During tracking and soft start ramp 75% to 125% current step 300 + (600 × NRails) µs Over-temperature fault response time Temperature rise of 10°C/sec, OT threshold = 100°C 2.5 S During a STORE_DEFAULT_ALL command, which stores the entire configuration to nonvolatile memory, the fault detection latency can be up to 10 ms. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated UCD9248 www.ti.com SLVSA33 – JANUARY 2010 HARDWARE FAULT DETECTION LATENCY The controller contains hardware fault detection circuits that are independent of the ADC monitoring sequencer. PARAMETER tFAULT tCLF TEST CONDITIONS MAX UNIT 15 + 3 × NumPhases µs Time to disable DPWM output based on corresponding active FLTpin High level on FAULT pin Time to disable the first DPWM output based on internal analog comparator fault Step change in CS voltage from 0V to 2.5V 4 Switch Cycles Time to disable all remaining DPWM and SRE outputs configured for the voltage rail after an internal analog comparator fault Step change in CS voltage from 0V to 2.5V 10 + 3 × NumPhases µs PMBUS/SMBUS/I2C The timing characteristics and timing diagram for the communications interface that supports I2C, SMBus and PMBus are shown below. I2C/SMBus/PMBus TIMING CHARACTERISTICS TA = –40°C to 125°C, 3V < V33 < 3.6V, typical values at TA = 25°C PARAMETER TEST CONDITIONS MIN TYP MAX UNIT fSMB SMBus/PMBus operating frequency Slave mode; SMBC 50% duty cycle 10 1000 kHz fI2C I2C operating frequency Slave mode; SCL 50% duty cycle 10 1000 kHz t(BUF) Bus free time between start and stop t(HD:STA) t(SU:STA) 4.7 µs Hold time after (repeated) start 0.26 µs Repeated start setup time 0.26 µs t(SU:STO) Stop setup time 0.26 µs t(HD:DAT) Data hold time 0 ns t(SU:DAT) Data setup time t(TIMEOUT) Error signal/detect t(LOW) Clock low period Receive mode 50 See (1) ns 35 0.5 ms µs t(HIGH) Clock high period See (2) 50 µs t(LOW:SEXT) Cumulative clock low slave extend time See (3) 25 ms tFALL Clock/data fall time See (4) 120 ns See (5) 120 ns tRISE (1) (2) (3) (4) (5) Clock/data rise time 0.26 The UCD9248 times out when any clock low exceeds t(TIMEOUT). t(HIGH), max, is the minimum bus idle time. SMBC = SMBD = 1 for t > 50 ms causes reset of any transaction involving UCD9248 that is in progress. t(LOW:SEXT) is the cumulative time a slave device is allowed to extend the clock cycles in one message from initial start to the stop. Rise time tRISE = VILMAX – 0.15) to (VIHMIN + 0.15) Fall time tFALL = 0.9 V33 to (VILMAX – 0.15) Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 5 UCD9248 SLVSA33 – JANUARY 2010 www.ti.com Figure 1. I2C/SMBus/PMBus Timing in Extended Mode Diagram 6 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated UCD9248 www.ti.com SLVSA33 – JANUARY 2010 Fusion Power Peripheral 4 EAp4 EAn4 Analog front end (AFE) Digital High Res PWM Compensator 3P/3Z IIR DPWM-4A DPWM-4B FAULT -4A FAULT -4B Fusion Power Peripheral 3 EAp3 EAn3 Analog front end (AFE) Digital High Res PWM Compensator 3P/3Z IIR DPWM-3A DPWM-3B FAULT -3A FAULT -3B Fusion Power Peripheral 2 EAp2 EAn2 Analog front end (AFE) Digital High Res PWM Compensator 3P/3Z IIR DPWM-2A DPWM-2B FAULT -2A FAULT -2B Fusion Power Peripheral 1 Aalog front end EAp1 EAn1 Diff Amp Ref Compensator Err Amp Digital High Res PWM IIR 3P/3Z Coeff. Regs ADC 6 bit DPWM-1A DPWM-1B FAULT -1A FAULT -1B SYNC-IN SYNC-OUT 5 V33x 6 xGnd BPCap 3.3V reg. controller & 1.8V regulator Analog Comparators Ref 1 ADDR-0 ADDR-1 CS-1A CS-1B CS-2A CS-2B CS-3A CS-3B CS-4A CS-4B Vin/Iin Vtrack Temperature Ref 2 12-bit ADC 260 ksps ADCref Ref 3 Ref 4 Trip1 ARM-7 core SRE control Trip2 Trip3 Trip4 Flash memory with ECC Mux control Seq. control Osc POR/BOR internal Temp sense PMBus SRE-4B SRE-4A SRE-3B SRE-3A SRE-2B SRE-2A SRE-1B SRE-1A TMUX0 TMUX1 TMUX2 SEQ_1 SEQ_2 SEQ_3 PMBus-Clk PMBus-Data PMBus-Alert PMBus-Cntl PGood nRESET Figure 2. Functional Block Diagram Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 7 UCD9248 SLVSA33 – JANUARY 2010 www.ti.com AGND3 CS-1B CS-2B ADDR-0 ADDR-1 CS-1A CS-3B CS-4B Aux-in (AD14) Aux-in (AD13) V33FB EAn4 EAp4 EAn3 EAp3 EAn2 EAp2 EAn1 EAp1 AGND2 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 The UCD9248 is available in an 80-pin TQFP package (PFC). ADCref 1 60 AGND1 CS-4A 2 59 BPCap CS-3A 3 58 V33A CS-2A 4 57 V33D Vin/Iin 5 56 V33DIO Vtrack 6 55 DGND3 Temperature 7 54 TMUX-2 V33DIO 8 53 SEQ-2 DGND1 9 52 SRE-3B SEQ-3 10 51 SRE-2A SRE-1B 11 50 SRE-4B SRE-1A 12 49 PGood nRESET 13 48 TRST TRCK 14 47 TMS FLT-1A 15 46 TDI FLT-1B 16 45 TDO FLT-2A 17 44 TCK FLT-2B 18 43 FLT-4B PMBus_Clk 19 42 FLT-4A PMBus_Data 20 41 FLT-3B 40 PMBus_Control TMUX-1 36 PMBus_Alert 39 35 TMUX-0 34 DGND2 38 33 SRE-4A SRE-3A 32 SEQ-1 37 31 Sync-In SRE-2B 30 FLT-3A 28 DPWM-4B Sync-Out 27 DPWM-4A 29 26 24 DPWM-2B DPWM-3B 23 DPWM-2A 25 22 DPWM-1B DPWM-3A 21 DPWM-1A UCD9248 Figure 3. Pin Assignment Diagram TYPICAL APPLICATION SCHEMATIC Figure 4 shows the UCD9248 power supply controller as part of a system that provides the regulation of one eight-phase power supply. The loop for the power supply is created by the voltage output feeding into the differential voltage error ADC (EADC) input, and completed by DPWM outputs feeding into the gate drivers for each power stage. The ±Vsenserail signal must be routed to the EAp/EAn input that matches the number of the lowest DPWM configured as part of the rail. (See more detail in Flexible Rail/Power Stage Configuration.) 8 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated UCD9248 www.ti.com SLVSA33 – JANUARY 2010 UCD7231 Power Stage Vin Vin Vin +3.3V FF BST PWM HS_Gate SRE VGG LS_Gate PwPd AGND VGG_DIS FLT-1A Vtrack Temperature +Vs1 PGND RDLY BPCAP V33DIO V33DIO V33A V33D V33FB ILIM Vin/Iin -Vs UCD7231 SRE_Mode Vin/Iin Temp _1A +Vs SW IOUT BP3 Temperature Sensor HS_SNS CSP CSN DPWM-1A Temperature SRE-1A CS-1A EAP1 EAN1 -Vs1 FLT-1B EAP2 PWM SRE-1B SRE CS-1B EAP3 Temp FF DPWM-1B EAN2 UCD7231 Power Stage Temp _1B +Vs -Vs IOUT EAN3 FLT-2A EAP4 PWM SRE-2A SRE CS-2A Sync_In Temp FF DPWM-2A EAN4 UCD7231 Power Stage Temp _2A -Vs IOUT Sync_Out -Vs1 FLT-2B ADCref PWM SRE-2B Aux-in (AD14) CS-2B IOUT FLT-3A DPWM-3A FF PWM SEQ-2 SEQ-3 TMUX-0 TMUX-1 SRE UCD7231 Power Stage Temp _2B +Vs -Vs UCD9248 SEQ-1 TMUX-1 TMUX-2 Temp FF DPWM-2B Aux-in (AD13) TMUX-0 +Vs1 +Vs SRE-3A SRE CS-3A Temp UCD7231 Power Stage Temp _3A +Vs -Vs IOUT TMUX-2 +3.3V FLT-3B TRCK PWM SRE-3B TDI SRE CS-3B TDO Temp FF DPWM-3B TMS UCD7231 Power Stage Temp _3B +Vs -Vs IOUT TCK nTRST FLT-4A PWM SRE-4A ADDR-1 Temp FF DPWM-4A ADDR-0 SRE CS-4A UCD7231 Power Stage Temp _4A +Vs -Vs IOUT PMBus_Clock PMBus_Data PMBus_Alert FLT-4B PMBus_Cntl DPWM-4B DGND3 DGND2 DGND1 AGND3 AGND2 AGND1 PGood nRESET Temp FF PWM SRE-4B PowerPad +3.3V SRE CS-4B UCD7231 Power Stage Temp _4B +Vs -Vs IOUT +3.3V +3.3V Vcc Temperature Temp _1A A0 Temp _1B A1 Temp _2A A2 Temp _2B A3 Temp _3A A7 Temp _3B A5 S2 TMUX-2 Temp _4A A6 S1 TMUX-1 Temp _4B A7 S0 TMUX-0 A Vcc Iin Vin B2 A B1 S Gnd CD74HC4051 Vin/Iin SN74LVC1G3157 TMUX-0 Vee Gnd E Figure 4. Typical Application Schematic Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 9 UCD9248 SLVSA33 – JANUARY 2010 www.ti.com PIN DESCRIPTIONS PIN NO. 10 PIN NAME DESCRIPTION 1 ADCref ADC Decoupling capacitor – tie 0.1 µF capacitor to ground 2 CS-4A Power stage 4A current sense input and input to analog comparator 4 3 CS-3A Power stage 3A current sense input and input to analog comparator 3 4 CS-2A Power stage 2A current sense input and input to analog comparator 2 5 Vin/Iin Input supply sense, alternates between Vin and Iin 6 Vtrack Voltage track input 7 Temperature Temperature sense input 8 V33DIO Digital I/O 3.3 V supply 9 DGND1 Digital Ground 10 SEQ-3 Sequencing Input/Output 11 SRE-1B Synchronous rectifier enable output 1B, active high 12 SRE-1A Synchronous rectifier enable output 1A, active high 13 nRESET Active low device reset input, pullup to 3.3V with 10 kΩ resistor 14 TRCK JTAG Test return clock 15 FLT-1A External fault input 1A, active high 16 FLT-1B External fault input 1B, active high 17 FLT-2A External fault input 2A, active high 18 FLT-2B External fault input 2B, active high 19 PMBus_Clock PMBus Clock, pullup to 3.3 V with 2 kΩ resistor 20 PMBus_Data PMBus Data, pullup to 3.3 V with 2 kΩ resistor 21 DPWM-1A Digital Pulse Width Modulator output 1A 22 DPWM-1B Digital Pulse Width Modulator output 1B 23 DPWM-2A Digital Pulse Width Modulator output 2A 24 DPWM-2B Digital Pulse Width Modulator output 2B 25 DPWM-3A Digital Pulse Width Modulator output 3A 26 DPWM-3B Digital Pulse Width Modulator output 3B 27 DPWM-4A Digital Pulse Width Modulator output 4A 28 DPWM-4B Digital Pulse Width Modulator output 4B 29 FLT-3A External fault input 3A, active high 30 Sync-In Synchronization input to DPWM 31 Sync-Out Synchronization output from DPWM 32 SEQ-1 Sequencing Input/Output 33 SRE-4A Synchronous rectifier enable output 4A, active high 34 DGND2 Digital Ground 35 PMBus_Alert PMBus Alert, pullup to 3.3V with 2 kΩ resistor 36 PMBus_Cntl PMBus Control, pullup to 3.3V with 2 kΩ resistor 37 SRE-2B Synchronous rectifier enable output 2B, active high 38 SRE-3A Synchronous rectifier enable output 3A, active high 39 TMUX-0 Temperature multiplexer select output SO, Vin/Iin select 40 TMUX-1 Temperature multiplexer select output S1 41 FLT-3B External fault input 3B, active high 42 FLT-4A External fault input 4A, active high 43 FLT-4B External fault input 4B, active high 44 TCK JTAG Test clock 45 TDO JTAG Test data out 46 TDI JTAG Test data in tie to V33D with 10 kΩ resistor 47 TMS JTAG Test mode select – tie to V33D with 10 kΩ resistor Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated UCD9248 www.ti.com PIN NO. SLVSA33 – JANUARY 2010 PIN NAME DESCRIPTION 48 nTRST JTAG Test reset – tie to ground with 10kOhm resistor 49 PGood Power Good indication, Active high open-drain output. Pull-up to 3.3V with 10 kΩ resistor. 50 SRE-4B Synchronous rectifier enable output 4B, active high 51 SRE-2A Synchronous rectifier enable output 2A, active high 52 SRE-3B Synchronous rectifier enable output 3B, active high 53 SEQ-2 Sequencing Input/Output 54 TMUX-2 Temperature multiplexer select output S2 55 DGND3 Digital Ground 56 V33DIO Digital I/O 3.3V supply 57 V33D Digital core 3.3V supply 58 V33A Analog 3.3V supply 59 BPCap 1.8V bypass capacitor connection 60 AGND1 Analog Ground 61 AGND2 Analog Ground 62 EAP1 Error analog, differential voltage. Positive channel #1 input 63 EAN1 Error analog, differential voltage. Negative channel #1 input 64 EAP2 Error analog, differential voltage. Positive channel #2 input 65 EAN2 Error analog, differential voltage. Negative channel #2 input 66 EAP3 Error analog, differential voltage. Positive channel #3 input 67 EAN3 Error analog, differential voltage. Negative channel #3 input 68 EAP4 Error analog, differential voltage. Positive channel #4 input 69 EAN4 Error analog, differential voltage. Negative channel #4 input 70 V33FB Connection to the base of the 3.3V linear regulator transistor. (no connect if not using an external transistor) 71 Aux-In (AD13) Unused Analog Input – Tie to ground with a 10KOhm resistor 72 Aux-In (AD14) Unused Analog Input – Tie to ground with a 10KOhm resistor 73 CS-4B Power stage 4B current sense input 74 CS-3B Power stage 3B current sense input 75 CS-1A Power stage 1A current sense input and input to analog comparator 1 76 ADDR-1 Address sense input. Channel 1 77 ADDR-0 Address sense input. Channel 0 78 CS-2B Power stage 2B current sense input 79 CS-1B Power stage 1B current sense input 80 AGND3 Analog Ground PowerPad PowerPad It is recommended that this pad be connected to analog ground Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 11 UCD9248 SLVSA33 – JANUARY 2010 www.ti.com FUNCTIONAL OVERVIEW The UCD9248 contains four fusion power peripherals (FPP). Each FPP can be configured to regulated up to four DC/DC converter outputs. There are eight PWM outputs that can be assigned to drive the converter outputs. Each FPP consists of: • A differential input error voltage amplifier • A 10-bit DAC used to set the output regulation reference voltage. • A fast ADC with programmable input gain to digitally measure the error voltage. • A dedicated 3-pole/3-zero digital filter to compensate the error voltage. • A digital PWM (DPWM) engine that generates the PWM pulse width based on the compensator output. Each controller is configured through a PMBus serial interface. PMBus Interface The PMBus is a serial interface specifically designed to support power management. It is based on the SMBus interface that is built on the I2C physical specification. The UCD9248 supports revision 1.1 of the PMBus standard. Wherever possible, standard PMBus commands are used to support the function of the device. For unique features of the UCD9248, MFR_SPECIFIC commands are defined to configure or activate those features. These commands are defined in the UCD92xx PMBUS Command Reference. The UCD9248 is PMBus compliant, in accordance with the Compliance section of the PMBus specification. The firmware is also compliant with the SMBus 1.1 specification, including support for the SMBus ALERT function. The hardware can support 100 kHz, 400 kHz, or 1 MHz PMBus operation. Resistor Programmed PMBus Address Decode Two pins are allocated to decode the PMBus address. At power-up, the device applies a bias current to each address detect pin, and the voltage on that pin is captured by the internal 12-bit ADC. The PMBus address is calculated as follows: PMBus Address = 12 × PMBus Address 1 + PMBus Address 0 Where PMBus Address 1 and 0 are selected from Table 1. V33 ADDR - 0, ADDR - 1 pins Resistor to set PMBus Address UCD9248 10 mA IBIAS To 12 -bit ADC Figure 5. PMBus Address Detection Method Table 1. PMBus Address Bins PMBus ADDRESS 12 Submit Documentation Feedback RPMBus PMBus RESISTANCE (kΩ) open – 11 205 10 178 9 154 8 133 7 115 6 100 Copyright © 2010, Texas Instruments Incorporated UCD9248 www.ti.com SLVSA33 – JANUARY 2010 Table 1. PMBus Address Bins (continued) PMBus ADDRESS RPMBus PMBus RESISTANCE (kΩ) 5 86.6 4 75 3 64.9 2 56.2 1 48.7 0 42.2 short – A low impedance (short) on either address pin that produces a voltage below the minimum voltage causes the PMBus address to default to address 126. A high impedance (open) on either address pin that produces a voltage above the maximum voltage also causes the PMBus address to default to address 126. Some addresses should be avoid, see Table 2. Table 2. PMBus Address Assignment Rules ADDRESS STATUS 0 Prohibited 1-10 Avaliable 11 Avoid 12 Prohibited 13–125 Avaliable 126 Avoid 127 Prohibited REASON SMBus generall address call Causes confilcts with other devices during program flash updates. PMBus alert response protocol Default value; may cause conflicts with other devices. Used by TI manufacturing for device tests. JTAG Interface The JTAG interface can provide an alternate interface for programming the device. It is enabled by default on the UCD9248. Bias Supply Generator (Shunt Regulator Controller) Internally, the circuits in the UCD9248 require 3.3V to operate. This can be provided directly on the V33x pins, or it can be generated from the power supply input voltage using an internal shunt regulator and an external transistor. The requirements for the external transistor are that it be an NPN device with a beta of at least 40. Figure 6 shows the typical application using the external series pass transistor. The base of the transistor is driven by a 10kΩ resistor to Vin and a transconduction amplifier whose output is on the VD33FB pin. The NPN emitter becomes the 3.3 V supply for the chip and requires bypass capacitors of 0.1µF and 4.7µF. The transconductance amplifier sinks current into the V33FB pin, in order to regulate the amount of current allowed into the base of the transistor, which regulates the collector current, which determines the emitter voltage (3.3V). The resistor value should be sized low enough to give sufficient base drive at minimum input voltage, yet large enough to not exceed the maximum current sink capability of the V33FB pin at maximum input voltage. Higher beta transistors help in increasing the minimum resistance value, as less base current is needed to sufficiently drive the higher beta transistor. A resistor value of 10 kΩ works well for most applications that use the FCX491A BJT. Some circuits in the device require 1.8V that is generated internally from the 3.3V supply. This voltage requires a 0.1 µF to 1 µF bypass capacitor from BPCap to ground. Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 13 UCD9248 SLVSA33 – JANUARY 2010 www.ti.com To Power Stage Vin FCX491A +3.3 V 4.7 mF 10 kW +1.8 V 0.1 mF V33A V33D BPCap V33FB 0.1 mF UC9248 Figure 6. Series-Pass 3.3V Regulator Controller I/O Power On Reset The UCD9248 has an integrated power-on reset (POR) circuit that monitors the supply voltage. At power-up, the POR circuit detects the V33D rise. When V33D is greater than VRESET, the device initiates an internal startup sequence. At the end of the delay sequence, the device begins normal operation, as defined by the downloaded device PMBus configuration. External Reset The device can be forced into the reset state by an external circuit connected to the nRESET pin. A logic low voltage on this pin holds the device in reset. To avoid an erroneous trigger caused by noise, a 10 kΩ pull up resistor to 3.3V is recommended. Output Voltage Adjustment The nominal output voltage is programmed by a combination of PMBus commands: VOUT_COMMAND, VOUT_CAL_OFFSET, VOUT_SCALE_LOOP, and VOUT_MAX. Their relationship is shown in Figure 7. These PMBus parameters need to be set such that the resulting Vref DAC value does not exceed the maximum value of Vref. Output voltage margining is configured by the VOUT_MARGIN_HIGH and VOUT_MARGIN_LOW commands. The OPERATION command selects between the nominal output voltage and either of the margin voltages. The OPERATION command also includes an option to suppress certain voltage faults and warnings while operating at the margin settings. 14 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated UCD9248 www.ti.com SLVSA33 – JANUARY 2010 OPERATION Command VOUT_MAX VOUT_MARGIN_HIGH + 3:1 Mux VOUT_COMMAND VOUT_ SCALE_ LOOP Limiter Vref DAC VOUT_MARGIN_LOW VOUT_CAL_OFFSET Figure 7. PMBus Voltage Adjustment Methods For a complete description of the commands supported by the UCD9248 see the UCD92xx PMBUS Command Reference. Each of these commands can also be issued from the Texas Instruments Fusion Digital Power™ Designer program. This Graphical User Interface (GUI) PC program issues the appropriate commands to configure the UCD9248 device. Calibration To optimize the operation of the UCD9248, PMBus commands are supplied to enable fine calibration of output voltage, output current, and temperature measurements. The supported commands and related calibration formulas may be found in the UCD92xx PMBUS Command Reference. Analog Front End (AFE) VEAP VEA GAFE = 1, 2, 4, or 8 Vead VEAN 6-bit result EADC GeADC = 8 mV/LSB Vref DAC CPU Vref = 1.563 mV/LSB PMBus Figure 8. Analog Front End Block Diagram The UCD9248 senses the power supply output voltage differentially through the EAP and EAN pins. The error amplifier utilizes a switched capacitor topology that provides a wide common mode range for the output voltage sense signals. The fully differential nature of the error amplifier also ensures low offset performance. The output voltage is sampled at a programmable time (set by the EADC_SAMPLE_TRIGGER PMBus command). When the differential input voltage is sampled, the voltage is captured in internal capacitors and then transferred to the error amplifier where the value is subtracted from the set-point reference which is generated by the 10-bit Vref DAC as shown in Figure 8. The resulting error voltage is then amplified by a programmable gain circuit before the error voltage is converted to a digital value by the error ADC (EADC). This programmable gain is configured through the PMBus and affects the dynamic range and resolution of the sensed error voltage as shown in Table 3. Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 15 UCD9248 SLVSA33 – JANUARY 2010 www.ti.com Table 3. Analog Front End Resolution AFE_GAIN for PMBus COMMAND AFE GAIN EFFECTIVE ADC RESOLUTION (mV) DIGITAL ERROR VOLTAGE DYNAMIC RANGE (mV) 0 1 8 –256 to 248 1 2 4 –128 to 124 2 4 2 –64 to 62 3 8 1 –32 to 31 The AFE variable gain is one of the compensation coefficients that are stored when the device is configured by issuing the CLA_GAINS PMBus command. Compensator coefficients are arranged in several banks: one bank for start/stop ramp or tracking, one bank for normal regulation mode and one bank for light load mode. This allows the user to trade-off resolution and dynamic range for each operational mode. The EADC, which samples the error voltage, has high accuracy, high resolution, and a fast conversion time. However, its range is limited as shown in Table 3. If the output voltage is different from the reference by more than this, the EADC reports a saturated value at –32 LSBs or 31 LSBs. The UCD9248 overcomes this limitation by adjusting the Vref DAC up or down in order to bring the error voltage out of saturation. In this way, the effective range of the ADC is extended. When the EADC saturates, the Vref DAC is slewed at a rate of 0.156 V/ms, referred to the EA differential inputs. The differential feedback error voltage is defined as VEA = VEAP – VEAN. An attenuator network using resistors R1 and R2 (see Figure 9) should be used to ensure that VEA does not exceed the maximum value of Vref when operating at the commanded voltage level. The commanded voltage level is determined by the PMBus settings described in the Output Voltage Adjustment section. R1 EAP +Vout R2 C2 Rin Ioff -Vout EAN Figure 9. Input Offset Equivalent Circuit Voltage Sense Filtering Conditioning should be provided on the EAP and EAN signals. Figure 9 a divider network between the output voltage and the voltage sense input to the controller. The resistor divider is used to bring the output voltage within the dynamic range of the controller. When no attenuation is needed, R2 can be left open and the signal conditioned by the low-pass filter formed by R1 and C2. As with any power supply system, maximize the accuracy of the output voltage by sensing the voltage directly across an output capacitor as close to the load as possible. Route the positive and negative differential sense signals as a balanced pair of traces or as a twisted pair cable back to the controller. Put the divider network close to the controller. This ensures that there is low impedance driving the differential voltage sense signal from the voltage rail output back to the controller. The resistance of the divider network is a trade-off between power loss and minimizing interference susceptibility. A parallel resistance (RP) of 1kΩ to 4kΩ is a good compromise. Once RP is chosen, R1 and R2 can be determined from the following formulas. R R1 = P K (1) Rp R2 = 1 - K (2) 16 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated UCD9248 www.ti.com SLVSA33 – JANUARY 2010 Where K= VEA VOUT @ VOUT_SCALE_LOOP (3) It is recommended that a capacitor be placed across the lower resistor of the divider network. This acts as an additional pole in the compensation and as an anti-alias filter for the EADC. To be effective as an anti-alias filter, the corner frequency should be 35% to 40% of the switching frequency. Then the capacitor is calculated as: 1 C2 = 2 p ´ 0.35 ´ FSW ´ RP (4) To obtain the best possible accuracy, the input resistance and offset current on the device should be considered when calculating the gain of a voltage divider between the output voltage and the EA sense inputs of the UCD9224. The input resistance and input offset current are specified in the parametric tables in this datasheet. VEA = VEAP – VEAN in the equation below. R2 R1R2 VEA = VO UT + IOFFSET æ R1R 2 ö æ R1R2 ö R1 + R2 + ç R1 + R2 + ç ÷ ÷ è REA ø è RE A ø (5) The effect of the offset current can be reduced by making the resistance of the divider network low. Digital Compensator Each voltage rail controller in the UCD9248 includes a digital compensator. The compensator consists of a nonlinear gain stage, followed by a digital filter consisting of a second order infinite impulse response (IIR) filter section cascaded with a first order IIR filter section. The Texas Instruments Fusion Digital Power™ Designer development tool can be used to assist in defining the compensator coefficients. The design tool allows the compensator to be described in terms of the pole frequencies, zero frequencies and gain desired for the control loop. In addition, the Fusion Digital Power™ Designer can be used to characterize the power stage so that the compensator coefficients can be chosen based on the total loop gain for each feedback system. The coefficients of the filter sections are generated through modeling the power stage and load. Additionally, the UCD9248 has three banks of filter coefficients: Bank-0 is used during the soft start/stop ramp or tracking; Bank-1 is used while in regulation mode; and Bank-2 is used when the measured output current is below the configured light load threshold. Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 17 UCD9248 SLVSA33 – JANUARY 2010 www.ti.com Figure 10. Digital Compensation The nonlinear gain block allows a different gain to be applied to the system when the error voltage deviates from zero. Typically Limit 0 and Limit 1 would be configured with negative values between –1 and –32 and Limit 2 and Limit 3 would be configured with positive values between 1 and 31. However, the gain thresholds do not have to be symmetric. For example, the four limit registers could all be set to positive values causing the Gain 0 value to set the gain for all negative errors and a nonlinear gain profile would be applied to only positive error voltages. The cascaded 1st order filter section is used to generate the third zero and third pole. DPWM Engine The output of the compensator feeds the high resolution DPWM engine. The DPWM engine produces the pulse width modulated gate drive output from the device. In operation, the compensator calculates the necessary duty cycle as a digital number representing a value from 0 to 100%. This duty cycle value is multiplied by the configured period to generate a comparator threshold value. This threshold is compared against the high speed switching period counter to generate the desired DPWM pulse width. This is shown in Figure 11. Each DPWM engine can be synchronized to another DPWM engine or to an external sync signal via the SYNC_IN and SYNC_OUT pins. Configuration of the synchronization function is done through a MFR_SPECIFIC PMBus command. See the DPWM Synchronization section for more details. 18 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated UCD9248 www.ti.com SLVSA33 – JANUARY 2010 DPWM Engine (1 of 4) SysClk SyncIn Clk high res ramp counter reset S Switch period R PWM gate drive output Current balance adj Compensator output EADC trigger (Calculated duty cycle) EADC trigger SyncOut threshold Figure 11. DPWM Engine Flexible Rail/Power Stage Configuration The UCD9248 can control up to four rails, each of which can comprise a programmable number of power stages. Constraints on the mapping of power stages to rails are described in detail in the UCD92xx PMBus Command Reference under the PHASE_INFO command. While there is significant flexibility in terms of mapping power stages to output rails, the differential voltage feedback signals (EAP/EAN) cannot be re-mapped through any commands, and therefore, must be connected to the proper input on the circuit board. Because the EADC sample trigger for a given front end stage is derived from the ramp timer of the first (lowest numbered) DPWM on the rail, the system must ensure that the number of the EADC and the number of the first DPWM match. For example, consider a two rail configuration in which 4 power stages (1A, 2A, 1B and 2B) are assigned to the first rail and 2 power stages (3A and 4A) to the second. The first DPWM on the first rail is 1; its voltage feedback must be through EAP1/EAN1. The first DPWM on the second rail is 3; its voltage feedback must be through EAP3/EAN3. (In this configuration EAP2/EAN2 and EAP4/EAN4 are unused and are disabled to reduce unnecessary power consumption.) DPWM Phase Distribution The number of voltage rails is configured using the PHASE_INFO PMBus command. The UCD9248 automatically synchronizes the first power stage of each voltage rail. The phase (in time) of each 1st power stage is shifted by an amount in order to minimize input current ripple. The amount that each 1st power stage is shifted is: 3t trail-rail spread = sw 13 (6) Where tSW is the period of the rail with the fastest switching frequency. The ratio 3/13 is chosen because it is close to 1/4, but it is a prime ratio. This should ensure that any configuration of rails and power stages should not have the leading edge of the DPWM signal aligned. Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 19 UCD9248 SLVSA33 – JANUARY 2010 www.ti.com The PHASE_INFO PMBus command is also used to configure the number of power stages driving each voltage rail. When multiple power stages are configured to drive a voltage rail, the UCD9248 automatically distributes the phase of each DPWM output to minimize ripple. This is accomplished by setting the rising edge of each DPWM pulse to be separated by: tsw tphase-phase spread = Nphases (7) Where tSW is the switching period and NPhases is the number of power stages driving a voltage rail. DPWM Synchronization DPWM synchronization provides a method to link the timing between rails on two distinct devices at the switching rate; i.e., two rails on different devices can be configured to run at the same frequency and sync forcing them not to drift from each other. (Note that within a single device, because all rails are driven off a common clock there is no need for an internal sync because rails won’t drift.) The PMBus SYNC_IN_OUT command sets which rails (if any) should follow the sync input, and which rail (if any) should drive the sync output. For rails that are following the sync input, the DPWM ramp timer for that output is reset when the sync input goes high. This allows the slave device to sync to inputs that are faster. On the fast side, there is no limit to how much faster the input is compared to the defined frequency of the rail; when the pulse comes in, the timer is reset and the frequencies are locked. This is the standard mode of operation -setting the slave to run slower, and letting the sync speed it up. The Sync Input and Output Configuration Word set by the PMBus command consists of two bytes. The upper byte (sync_out) controls which rail drives the sync output signal (0=DPWM1, 1=DPWM2, 2=DPWM3, 3=DPWM4. Any other value disables sync_out). The lower byte (sync_in) determines which rail(s) respond to the sync input signal (each bit represents one rail -note that multiple rails can be synchronized to the input). The DPWM period is aligned to the sync input. For more information, see the UCD92xx PMBUS Command Reference. Note that once a rail is synchronized to an external source, the rail-to-rail spacing that attempts to minimize input current ripple is lost. Rail-to-rail spacing can only be restored by power cycling or issuing a SOFT_RESET command. Phase Shedding at Light Current Load By issuing LIGHT_LOAD_LIMIT_LOW, LIGHT_LOAD_LIMIT_HIGH, and LIGHT_LOAD_CONFIG commands, the UCD9248 can be configured to shed (disable) power stages when at light load. When this feature is enabled, the device disables the configured number of power stages when the average current drops below the specified LIGHT_LOAD_LIMIT_LOW. In addition, a separate set of compensation coefficients can be loaded into the digital compensator when entering a light load condition. Phase Adding at Normal Current Load After shedding phases, if the current load is increased past the LIGHT_LOAD_LIMIT_HIGH threshold, all phases are re-enabled. If the compensator was configured for light load, the normal load coefficients are restored as well. See the UCD92xx PMBUS Command Reference for more information. Output Current Measurement Pins CS-1A, CS-1B, CS-2A, CS-2B, CS-3A, CS-3B, CS-4A, and CS-4B are used to measure either output current or inductor current in each of the controlled power stages. PMBus commands IOUT_CAL_GAIN and IOUT_CAL_OFFSET are used to calibrate each measurement. See the UCD92xx PMBus Command Reference for specifics on configuring this voltage to current conversion. When the measured current is outside the range of either the over-current or undercurrent threshold, a FAULT is declared and the UCD9248 performs the PMBus configured fault recovery. ADC current measurements are digitally averaged before they are compared against the FAULT threshold. The output current is measured at a rate of one output rail per 200 microseconds. The current measurements are then passed through a smoothing filter to reduce noise on the signal and prevent false errors. The output of the smoothing filter asymptotically approaches the input value with a time constant that is approximately 3.5 times the sampling interval. 20 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated UCD9248 www.ti.com SLVSA33 – JANUARY 2010 Table 4. Output Current Filter Time Constants NUMBER OF OUTPUT RAILS OUTPUT CURRENT SAMPLING INTERVALS (µs) FILTER TIME CONSTANTS (ms) 1 200 0.7 2 400 1.4 3 600 2.1 4 800 2.8 For example, with a single rail, the filter has the transfer function characteristics that shows the signal magnitude at the output of the averaging filter due to a sine wave input for a range of frequencies. This plot includes an RC analog low pass network, with a corner frequency of 3 kHz, on the current sense inputs. This averaged current measurement is used for output current fault detection; see “Over-Current Detection” section. In response to a PMBus request for a current reading, the device returns an average current value. When the UCD9248 is configured to drive a multi-phase power converter, the device adds the average current measurement for each of the power stages tied to a power rail. Current Sense Input Filtering Each power stage current is monitored by the device at the CS pins. There are 4 "A" channel pins and 4 "B" channel pins. The B channel monitors the current with a 12-bit ADC and samples each current sense voltage in turn. The A channels monitor the current with the same12-bit ADC and also monitor the current with a digitally programmable analog comparator. The comparator can be disabled by writing a zero to the FAST_OC_FAULT_LIMIT. Because the current sense signal is both digitally sampled and compared to the programmable over-current threshold, it should be conditioned with an RC network acting as an anti-alias filter. If the comparator is disabled, the CS input should be filtered at 35% of the sampling rate. An RC network with this characteristic can be calculated as N T R = 0.45 rails Iout C (8) Where Nrails is the number of rails configured and TIout is the sample period for the current sense inputs. Therefore, when the comparator is not used, the recommended component values for the RC network are C = 10 nF and R = 35.7 kΩ. When the fast over-current comparator is used, the filter corner frequency based on the ADC sample rate may be too slow and a corner frequency that is a compromise between the requirements of fast over-current detection and attenuating aliased content in the sampled current must be sought. In this case, the filter corner frequency can be calculated based on the time to cross the over-current threshold. ( VOC_thres = VCS_nom + DVImon 1 - e-t t ) (9) Where VOC_thres is the programmed OC comparator threshold, VCS_nom is the nominal CS voltage, ΔVImon is the change in CS voltage due to an over-current fault and is the filter time constant. Using the equation for the comparator voltage above, the RC network values can be calculated as T 1 R = det C ln(D VImon ) - ln(ΔVImon - VOC_thres + VCS_nom ) (10) Where Tdet is the time to cross the over-current comparator threshold. For Tdet = 10 µsec, ΔVImon = 1.5V, VOC_thres = 2.0V and VCS_nom = 1.5V, the corner frequency is 6.4 kHz and the recommended RC network component values are C = 10 nF and R = 2.49 kΩ. Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 21 UCD9248 SLVSA33 – JANUARY 2010 www.ti.com Output Current Balancing When the UCD9248 is configured to drive multiple power stage circuits from one compensator, current balancing is implemented by adjusting each gate drive output pulse width to correct for current imbalance between the connected power stage sections. The UCD9248 balances the current by monitoring the current at the CS analog input for each power stage and then adding a current balance adjustment value to the DPWM ramp threshold value for each power stage. When there is more than one power stage connected to the voltage rail, the device continually determines which stage has the highest measured current and which stage has the lowest measured current. To balance the currents while maintaining a constant total current, the adjustment value for the power stage with the lowest current is increased by the same amount as the adjustment value for the power stage with the highest current is decreased. A slight modification to this algorithm is made to keep the adjustment values positive in order to ensure that a positive DPWM duty cycle is commanded under all conditions. Over-Current Detection Several mechanisms are provided to sense output current fault conditions. This allows for the design of power systems with multiple layers of protection. 1. An integrated gate driver, such as the UCD72xx of integrated gate drivers, can be used to generate the FAULT signal. The driver monitors the voltage drop across the high side FET and if it exceeds a resistor/voltage programmed threshold, the driver activates its fault output. The FAULT input can be disabled by reconfiguring the FAULT pin to be a sequencing pin. A logic high signal on the FAULT input causes a hardware interrupt to the internal CPU. The CPU then determines which DPWM outputs are configured to be associated with the voltage rail that contained the fault and disables those DPWM and SRE outputs. This process takes about 14 microseconds. 2. Inputs CS-1A, CS-2A, CS-3A and CS-4A each drive an internal analog comparator. These comparators can be used to detect the voltage output of a current sense circuit. Each comparator has a separate PMBus configurable threshold. This threshold is set by issuing the FAST_OC_FAULT_LIMIT command. Though the command is specified in amperes, the hardware threshold is programmed with a value between 31mV and 2V in 64 steps. The conversion from amperes to volts is accomplished by issuing the IOUT_CAL_GAIN command. When the current sense voltage exceeds the configured threshold the corresponding DPWM and SRE outputs are driven low on the voltage rail with the fault. 3. Each Current Sense input to the UCD9248 is also monitored by the 12-bit ADC. Each measured value is scaled using the IOUT_CAL_GAIN and IOUT_CAL_OFFSET commands. The currents for each power stage configured as part of a voltage rail are summed and compared to the OC limit set by the IOUT_OC_FAULT_LIMIT command. The action taken when a fault is detected is defined by the IOUT_OC_FAULT_RESPONSE command. Because the current measurement is averaged with a smoothing filter, the response time to an over-current condition depends on a combination of the time constant (t) from Table 4, the recent measurement history, and how much the measured value exceeds the over-current limit. When the current steps from a current (I1) that is less than the limit to a higher current (I2) that is greater than the limit, the output of the smoothing filter is: ( Ismoothed (t) = I1 + (I2 - I1 ) 1 - e-t/t ) (11) At the point when Ismoothed exceeds the limit, the smoothing filter lags time, tlag is: æ I - I1 ö tlag = t ln ç 2 ÷ è I2 - Ilimit ø (12) The worst case response time to an over-current condition is the sum of the sampling interval (see Table 4) and the smoothing filter lag, tlag from the equation above. 22 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated UCD9248 www.ti.com SLVSA33 – JANUARY 2010 Current Foldback Mode When the measured output current exceeds the value specified by the IOUT_OC_FAULT_LIMIT command, the UCD9248 attempts to continue to operate by reducing the output voltage in order to maintain the output current at the value set by IOUT_OC_FAULT_LIMIT. This continues indefinitely as long as the output voltage remains above the minimum value specified by IOUT_OC_LV_FAULT_LIMIT. If the output voltage is pulled down to less than that value, the device shuts down, if programmed to do so by the IOUT_OC_LV_FAULT_RESPONSE command. Input Voltage and Current Monitoring The Vin/Iin pin on the UCD9248 monitors the input voltage and current. To measure both input voltage and input current, an external multiplexer is required, see Figure 4. If measurement of only the input voltage, and not input current, is desired, then a multiplexer is not needed. The multiplexer is switched between voltage and current using the TMUX-0 signal. (This signal is the LSB of the temperature mux select signals, so the TMUX-0 signal is connected both to the temperature multiplexer as well as the voltage/current multiplexer). When TMUX-0 is low the Vin/Iin pin will be sampled for Vin. When TMUX-0 is high the Vin/Iin pin will be sampled for Iin. The Vin/Iin pin is monitored using the internal 12-bit ADC and so has a dynamic range of 0 to VADC_RANGE. The fault thresholds for the input voltage are set using the VIN_OV_FAULT_LIMIT and VIN_UV_FAULT_LIMIT commands. The scaling for Vin is set using the VIN_SCALE_MONITOR command, and the scaling for Iin is set using the IIN_SCALE_MONITOR command. Input UV Lockout The input supply lock-out voltage thresholds are configured with the VIN_ON and VIN_OFF commands. When input supply voltage drops below the value set by VIN_OFF, the device starts a normal soft stop ramp. When the input supply voltage drops below the voltage set by VIN_UV_FAULT_LIMIT, the device performs per the configuration using the VIN_UV_FAULT_RESPONSE command. For example, when the bias supply for the controller is derived from another source, the response code can be set to "Continue" or "Continue with delay," and the controller attempts to finish the soft stop ramp. If the bias voltages for the controller and gate driver are uncertain below some voltage, the user can set the UV fault limit to that voltage and specify the response code to be "shut down immediately" disabling all DPWM and SRE outputs. If VIN_OFF sets the voltage at which the output voltage soft-stop ramp is initiated, and VIN_UV_FAULT_LIMIT sets the voltage where power conversion is stopped. Temperature Monitoring Both the internal device temperature and up to eight external temperatures are monitored by the UCD9248. The controller supports multiple PMBus commands related to temperature, including READ_TEMPERATURE_1, which reads the internal temperature, READ_TEMPERATURE_2, which reads the external power stage temperatures, OT_FAULT_LIMIT, which sets the over temperature fault limit, and OT_FAULT_RESPONSE, which defines the action to take when the configured limit is exceeded. If more than one external temperature is to be measured, the UCD9248 provides analog multiplexer select pins (TMUX0-2) to allow up to 8 external temperatures to be measured. The output of the multiplexer is routed to the Temperature pin. The controller cycles through each of the power stage temperature measurement signals. The signal from the external temperature sensor is expected to be a linear voltage proportional to temperature. The PMBus commands TEMPERATURE_CAL_GAIN and TEMPERATURE_CAL_OFFSET are used to scale the measured temperature-dependent voltage to °C. The inputs to the multiplexer are mapped in the order that the outputs are assigned using the PHASE_INFO PMBus command. For example, if only one power stage is wired to each DPWM, the four temperature signals should be wired to the first four multiplexer inputs. The UCD9248 monitors temperature using the 12-bit monitor ADC, sampling each temperature in turn with an 100 ms sample period. These measurements are smoothed by a digital filter, similar to that used to smooth the output current measurements. The filter has a time constant 15.5 times the sample interval, or 1.55 s (15.5 × 0 ms = 1.55 seconds). This filtering reduces the probability of false fault detections. Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 23 UCD9248 SLVSA33 – JANUARY 2010 www.ti.com +3.3 V Vcc Temperature Temp _1A Temp _1B A0 Temp _2A Temp _2B A2 A3 Temp _3A A7 Temp _3B A5 S2 TMUX-2 Temp _4A A6 S1 TMUX-1 Temp _4B A7 S0 TMUX-0 A A1 CD74HC4051 Vee Gnd E Figure 12. Temperature Mux (1 rail, 8 phases) Below is an example of a system with two output voltage rails driven by 3 power stages each. The first output voltage rail is driven with DPWM-1A, DPWM-1B and DPWM-3A. The second output voltage rail is driven with DPWM-2A, DPWM-2B and DPWM-4A. The order in which the temperature multiplexer inputs are assigned is shown in Table 5. 24 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated UCD9248 www.ti.com SLVSA33 – JANUARY 2010 Table 5. Temperature Sensor Mapping TEMPERATURE MUX INPUT POWER STAGE A0 DPWM-1A A1 DPWM-1B A2 DPWM-3A A3 DPWM-2A A4 DPWM-2B A5 DPWM-4A A6 n/c A7 n/c Temperature Balancing Temperature balancing between phases is performed by adjusting the current such that cooler phases draw a larger share of the current. Temperature balancing occurs slowly (the loop runs at a 10 Hz rate), and only when the phase currents exceeds the PMBus settable TEMP_BALANCE_IMIN. This minimum current threshold prevents the controller from "winding up" and forcing one phase to carry all the current under a low-load condition, when the total current may be insufficient to significantly affect phase temperatures. Soft Start, Soft Stop Ramp Sequence The UCD9248 performs soft start and soft stop ramps under closed loop control. Performing a start or stop ramp or tracking is considered a separate operational mode. The other operational modes are normal regulation and light load regulation. Each operational mode can be configured to have an independent loop gain and compensation. Each set of loop gain coefficients is called a "bank" and is configured using the CLA_GAINS PMBus command. Start ramps are performed by waiting for the configured start delay TON_DELAY and then ramp the internal reference toward the commanded reference voltage at the rate specified by the TON_RISE time and VOUT_COMMAND. The DPWM and SRE outputs are enabled when the internal ramp reference equals the preexisting voltage (pre-bias) on the output and the calculated DPWM pulse width exceeds the pulse width specified by DRIVER_MIN_PULSE. This ensures that a constant ramp rate is maintained, and that the ramp is completed at the same time it would be if there were not a pre-bias condition. Figure 13 shows the operation of soft-start ramps and soft-stop ramps. Figure 13. Start and Stop Ramps Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 25 UCD9248 SLVSA33 – JANUARY 2010 www.ti.com When a voltage rail is in its idle state, the DPWM and SRE outputs are disabled, and the differential voltage on the EAP/EAN pins are monitored by the controller. During idle the Vref DAC is adjusted to minimize the error voltage. If there is a pre-bias (that is, a non-zero voltage on the regulated output), then the device can begin the start ramp from that voltage with a minimum of disturbance. This is done by calculating the duty cycle that is required to match the measured voltage on the rail. Nominally this is calculated as Vout / Vin. If the pre-bias voltage on the output requires a smaller pulse width than the driver can deliver, as defined by the DRIVER_MIN_PULSE PMBus command, then the start ramp is delayed until the internal ramp reference voltage has increased to the point where the required duty cycle exceeds the specified minimum duty. Once a soft start/stop ramp has begun, the output is controlled by adjusting the Vref DAC at a fixed rate and allowing the digital compensator control engine to generate a duty cycle based on the error. The Vref DAC adjustments are made at a rate of 10 kHz and are based on the TON_RISE or TOFF_FALL PMBus configuration parameters. Although the presence of a pre-bias voltage or a specified minimum DPWM pulse width affects the time when the DPWM and SRE signals become active, the time from when the controller starts processing the turn-on command to the time when it reaches regulation is TON_DELAY plus TON_RISE, regardless of the pre-bias or minimum duty cycle. During a normal ramp (i.e., no tracking, no current limiting events and no EADC saturation), the set point slews at a pre-calculated rate based on the commanded output voltage and TON_RISE. Under closed loop control, the compensator follows this ramp up to the regulation point. Because the EADC in the controller has a limited range, it may saturate due to a large transient during a start/stop ramp. If this occurs, the controller overrides the calculated set point ramp value, and adjusts the reference DAC in the direction to minimize the error. It continues to step the reference DAC in this direction until the EADC comes out of saturation. Once it is out of saturation, the start ramp continues, but from this new set point voltage; and therefore, has an impact on the ramp time. Voltage Tracking Each voltage rail can be configured to operate in a tracking mode. When a voltage rail is configured to track another voltage rail, it adjusts the set point to follow the master, which can be either another internal rail or the external Vtrack pin. As in standard non-tracking mode, a target Vout is still specified for the voltage rail. If the tracking input exceeds this target, the tracking voltage rail stops following the master signal, switches to regulation gains, and regulates at the target voltage. When the tracking input drops below the target with 20 mV of hysteresis, tracking gains are re-loaded and the voltage rail follows the tracking reference. Note that the target can be set above the range of the tracking input, forcing the voltage rail to always remain in tracking mode with the start-stop gains. During tracking, the Vref DAC is permitted to change only as fast as is possible without inducing the EADC to saturate. This limit may be reached if the master ramps at an extremely fast rate, or if the master is at a significantly different voltage when the rail is turned on. A current limit (current foldback) or the detection of the EADC saturating will force the rail to temporarily deviate from the tracking reference. This behavior is the same in normal regulation mode. The PMBus command TRACKING_SOURCE is available to enable tracking mode and select the master to track. The tracking mode is set individually for each rail, allowing each rail to have a different master, multiple rails to share a master, or some rails to track while others remain independent. Additionally, TRACKING_SCALE_MONITOR permits tracking at voltage with a fixed ratio to a master voltage. For example, a ratio of 0.5 causes the rail to regulate at one half of the master’s voltage. Sequencing There are three methods to sequence voltage rails controlled by the UCD9248 that allow for a variety of system sequencing configurations. Each of these options is configurable in the GUI. These methods include: 1. Use the PMBus to set the soft start/stop parameters for each rail. Multiple start/stop sequences may be triggered simultaneously. Each voltage rail performs its sequencing in an open-loop manner. If any rail fails to complete its sequence, all other rails are unaffected. 2. Daisy-chain the Power Good output signal from one controller to the PMBus_CTRL input on another. 3. Use the GPIO_SEQ_CONFIG command to assign dependencies between rails, or to configure unused pins as sequencing control inputs or sequencing status outputs. 26 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated UCD9248 www.ti.com SLVSA33 – JANUARY 2010 Method 1: Each rail has programmable delay times, TON_DELAY and TOFF_DELAY, before beginning a soft start ramp or a soft stop ramp, and programmable ramp times, TON_RISE and TOFF_FALL determine how long the ramp takes. These PMBus commands are defined in the UCD92xx PMBUS Command Reference. The parameters can also be configured using the Fusion Digital Power™ Designer GUI (see http://focus.ti.com/docs/toolsw/folders/print/fusion_digital_power_designer.html). The configurable times can be used to program a time based sequence for each voltage rail. Using this method each rail ramps independently and completes the ramp regardless of the success of the other rails. The start/stop sequence is initiated for a single rail by the PMBus_CTRL pin or via the PMBus using the OPERATION or ON_OFF_CONTROL commands. The start/stop sequence may be initiated simultaneously for multiple rails within the same controller by configuring each rail to respond to the PMBus_CTRL pin. Alternatively, after setting the PMBus PAGE variable to 255, subsequent OPERATION or ON_OFF_CONTROL commands applies to all rails at the same time. To simultaneously initiate start/stop sequences in multiple controllers, a common PMBus_CTRL signal can be fed into each controller. Alternatively, the PMBus Group Command Protocol may be used to send separate commands to multiple controllers. All the commands are sent in one continuous transmission and wait for the final STOP signal in order to start executing their commands simultaneously. Method 2: The PGood pin can be used to coordinate multiple controllers by running the PGood pin output from one controller to the PMBus_CTRL input pin of another. This imposes a master/slave relationship between multiple devices. During startup, the slave controllers initiate their start sequences after the master completes its start sequence and reaches its regulation voltage. During shut-down, as soon as the master starts its shut-down sequence, the shut-down signals to its slaves. Unlike Method 1, a shut-down on one or more rails on the master can initiate shut-downs of the slave devices. The master shut-downs can initiate intentionally or by a fault condition. The PMBus specification implies that the Power Good signal is active when ALL the rails in a controller are above their power-good “on” threshold setting. The UCD9248 allows the Power Good pin to be reprogrammed using the GPIO_SEQ_CONFIG command so that the pin responds to a desired subset of rails. This method works to coordinate multiple controllers, but it does not enforce interdependency between rails within a single controller. Method 3: Using the GPIO_SEQ_CONFIG command, several sequencing options can be configured using undedicated pins for input/output. As many as four pins can be configured as inputs, and as many as six as outputs. The outputs can be open-drain or actively driven with selectable polarity. Each rail can be configured to respond to a combination of the power-good status of other internal rails and/or the state of sequencing input pins. The output pins can be configured to reflect the power-good status of a combination of rails, or to one of several status indicators including power-good, an over-current warning, or the “open-drain outputs valid” signal. When using the output signals for sequencing, they may be routed to sequencing control inputs or to the PMBus_CTRL inputs on other controllers. Once each rail’s input dependencies are configured, the rail responds to those input pins or internal rails. Like method 2, shut-downs on one rail or controller can initiate shut-downs of other rails or controllers. Unlike method 2, GPIO_SEQ_CONFIG offers much more flexibility in assigning relationships between multiple rails within a single controller or between multiple controllers. It is possible for each controller to be both a master and a slave to another controller. GPIO_SEQ_CONFIG allows the configuration of fault relationships such that a fault on one rail can result in the shut down of any selection of rails in addition to the rail at fault. These fault interactions are not constrained to a single master/slave relationship; for example, a system can be configured such that a fault on any rail shuts down all rails. If the fault response of the failing rail is to shut down immediately, all dependent rails follow suit and shuts down immediately regardless of their programmed response code. The fault slaves can be configured to shutdown when the master first reports a fault or after the master has exhausted its retries. Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 27 UCD9248 SLVSA33 – JANUARY 2010 www.ti.com Each rail can be optionally configured to monitor a sequencing input pin for a specified period of time after it turns on and reaches its power good threshold. If the programmable timeout is reached before the input pin state matches its defined logic level, the rail is shut down, and a status error posted. This feature could be used, for example, to ensure that an LDO on the board did turn on when the main system voltage came up. Each rail is enabled independently of the other rails and has a unique timeout value; a single input pin is used as the timeout source. The setup of the GPIO_SEQ_CONFIG command is aided by the use of the Fusion Digital Power™ Designer, which graphically displays relationships between rails and provides intuitive controls to allocate and configure available resources. The following pins are available for use as sequencing control, provided they are not being used for their primary purpose: PIN NAME 80-PIN DPWM-1A IN/OUT DPWM-1B IN/OUT DPWM-2A IN/OUT DPWM-2B IN/OUT DPWM-3A IN/OUT DPWM-3B IN/OUT DPWM-4A IN/OUT DPWM-4B IN/OUT FAULT-1A IN/OUT FAULT-1B IN/OUT FAULT-2A IN/OUT FAULT-2B IN/OUT FAULT-3A IN/OUT FAULT-3B IN/OUT FAULT-4A IN/OUT FAULT-4B IN/OUT SRE-1A IN/OUT SRE-1B IN/OUT SRE-2A IN/OUT SRE-2B IN/OUT SRE-3A IN/OUT SRE-3B IN/OUT SRE-4A IN/OUT SRE-4B IN/OUT PGOOD IN/OUT SEQ-1 IN/OUT SEQ-2 IN SEQ-3 IN Non-volatile Memory Error Correction Coding The UCD9248 uses Error Correcting Code (ECC) to improve data integrity and provide high reliability storage of Data Flash contents. ECC uses dedicated hardware to generate extra check bits for the user data as it is written into the Flash memory. This adds an additional six bits to each 32-bit memory word stored into the Flash array. These extra check bits, along with the hardware ECC algorithm, allow for any single bit error to be detected and corrected when the Data Flash is read. ADCRef Pin The ADCRef pin is the decoupling pin for the ADC12. Connect this pin to ground through a 0.1µF to 1µF capacitor. 28 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated UCD9248 www.ti.com SLVSA33 – JANUARY 2010 APPLICATION INFORMATION Automatic System Identification ( Auto-ID™) By using digital circuits to create the control function for a switch-mode power supply, additional features can be implemented. One of those features is the measurement of the open loop gain and stability margin of the power supply without the use of external test equipment. This capability is called automatic system identification or Auto-ID™. To identify the frequency response, the UCD9248 internally synthesizes a sine wave signal and injects it into the loop at the set point DAC. This signal excites the system, and the closed-loop response to that excitation can be measured at another point in the loop. The UCD9248 measures the response to the excitation at the output of the digital compensator. From the closed-loop response, the open-loop transfer function is calculated. The open-loop transfer function may be calculated from the closed-loop response. Note that since the compensator and DPWM are digital, their transfer functions are known exactly and can be divided out of the measured open-loop gain. In this way the UCD9248 can accurately measure the power stage/load plant transfer function in situ (in place), on the factory floor or in an end equipment application and send the measurement data back to a host through the PMBus interface without the need for external test equipment. Details of the Auto-ID™ PMBus measurement commands can be found in the UCD92xx PMBus Command Reference. Data Logging The UCD9248 maintains a data log in non-volatile memory. This log tracks the peak internal and external temperature sensor measurements, peak current measurements and fault history. The PMBus commands and data format for the Data Logging can be found in the UCD92xx PMBus Command Reference (SLUU337). Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 29 PACKAGE OPTION ADDENDUM www.ti.com 15-Feb-2010 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Drawing Pins Package Eco Plan (2) Qty UCD9248PFC ACTIVE TQFP PFC 80 UCD9248PFCR ACTIVE TQFP PFC 80 96 Lead/Ball Finish MSL Peak Temp (3) Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR 1000 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 1 MECHANICAL DATA MTQF009A – OCTOBER 1994 – REVISED DECEMBER 1996 PFC (S-PQFP-G80) PLASTIC QUAD FLATPACK 0,27 0,17 0,50 60 0,08 M 41 61 40 80 21 1 0,13 NOM 20 Gage Plane 9,50 TYP 12,20 SQ 11,80 0,25 14,20 SQ 13,80 0,05 MIN 0°– 7° 0,75 0,45 1,05 0,95 Seating Plane 0,08 1,20 MAX 4073177 / B 11/96 NOTES: A. All linear dimensions are in millimeters. B. This drawing is subject to change without notice. C. Falls within JEDEC MS-026 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Amplifiers amplifier.ti.com Audio www.ti.com/audio Data Converters dataconverter.ti.com Automotive www.ti.com/automotive DLP® Products www.dlp.com Communications and Telecom www.ti.com/communications DSP dsp.ti.com Computers and Peripherals www.ti.com/computers Clocks and Timers www.ti.com/clocks Consumer Electronics www.ti.com/consumer-apps Interface interface.ti.com Energy www.ti.com/energy Logic logic.ti.com Industrial www.ti.com/industrial Power Mgmt power.ti.com Medical www.ti.com/medical Microcontrollers microcontroller.ti.com Security www.ti.com/security RFID www.ti-rfid.com Space, Avionics & Defense www.ti.com/space-avionics-defense RF/IF and ZigBee® Solutions www.ti.com/lprf Video and Imaging www.ti.com/video Wireless www.ti.com/wireless-apps Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2010, Texas Instruments Incorporated