MOSEL VITELIC V826664G24S 512 MB 200-PIN DDR UNBUFFERED SODIMM 2.5 VOLT 64M x 64 PRELIMINARY Features Description ■ JEDEC 200 Pin DDR Unbuffered Small-Outline, Dual In-Line memory module (SODIMM); 67,108,864 x 64 bit organization. ■ Utilizes High Performance 32M x 8 DDR SDRAM in SOC Packages ■ Single +2.5V (± 0.2V) Power Supply ■ Programmable CAS Latency, Burst Length, and Wrap Sequence (Sequential & Interleave) ■ Auto Refresh (CBR) and Self Refresh ■ All Inputs, Outputs are SSTL-2 Compatible ■ 8192 Refresh Cycles every 64 ms ■ Serial Presence Detect (SPD) ■ DDR SDRAM Performance The V826664G24S memory module is organized 67,108,864 x 64 bits in a 200 pin memory module. The 64M x 64 memory module uses 16 MoselVitelic 32M x 8 DDR SDRAM. The x64 modules are ideal for use in high performance computer systems where increased memory density and fast access times are required. Component Used tCK tAC Clock Frequency (max.) -6 -7 -75 -8 Units 166 143 133 125 MHz (PC333) (PC266A) (PC266B) (PC200) Clock Access Time CAS Latency = 2.5 6 7 7.5 8 ns Module Speed A1 PC1600 (100MHz @ CL2) B0 PC2100B (133MHz @ CL2.5) B1 PC2100A (133MHz @ CL2) C0 PC2700 (166MHz @ CL2.5) V826664G24S Rev. 1.0 August 2002 1 V826664G24S MOSEL VITELIC Part Number Information V 8 2 66 64 G 2 4 S DDR SDRAM 2.5V S G - XX COMPONENT PACKAGE, S = SOC WIDTH DEPTH COMPONENT REV LEVEL 200 PIN Unbuffered SODIMM X8 COMPONENT STTL REFRESH RATE 8K V826664G24S Rev. 1.0 August 2002 X SPEED A1 (100MHz@CL2) B0 ([email protected]) B1 (133MHz@CL2) LEAD FINISH C0 ([email protected]) G = GOLD MOSEL VITELIC MANUFACTURED 2 4 BANKS V826664G24S MOSEL VITELIC Block Diagram CS1# CS0# DQS0 DQS7 DM0 DM7 DQ0 DQ1 DQ2 DQ3 DQ4 DQ5 DQ6 DQ7 DM CS# DQS DQ U10 DQ DQ DQ DQ DQ DQ DQ DM CS# DQS DQ U11 DQ DQ DQ DQ DQ DQ DQ DQS2 DQ32 DQ33 DQ34 DQ35 DQ36 DQ37 DQ38 DQ39 DM CS# DQS DQ U50 DQ DQ DQ DQ DQ DQ DQ DM CS# DQS DQ U51 DQ DQ DQ DQ DQ DQ DQ DQ40 DQ41 DQ42 DQ43 DQ44 DQ45 DQ46 DQ47 DM CS# DQS DQ U60 DQ DQ DQ DQ DQ DQ DQ DM CS# DQS DQ U61 DQ DQ DQ DQ DQ DQ DQ DQ48 DQ49 DQ50 DQ51 DQ52 DQ53 DQ54 DQ55 DM CS# DQS DQ U70 DQ DQ DQ DQ DQ DQ DQ DM CS# DQS DQ U71 DQ DQ DQ DQ DQ DQ DQ DQ56 DQ57 DQ58 DQ59 DQ60 DQ61 DQ62 DQ63 DM CS# DQS DQ U80 DQ DQ DQ DQ DQ DQ DQ DM CS# DQS DQ U81 DQ DQ DQ DQ DQ DQ DQ DQS5 DM2 DM5 DQ8 DQ9 DQ10 DQ11 DQ12 DQ13 DQ14 DQ15 DM CS# DQS DQ U20 DQ DQ DQ DQ DQ DQ DQ DM CS# DQS DQ U21 DQ DQ DQ DQ DQ DQ DQ DQS4 DQS3 DM4 DM3 DQ16 DQ17 DQ18 DQ19 DQ20 DQ21 DQ22 DQ23 DM CS# DQS DQ U30 DQ DQ DQ DQ DQ DQ DQ DM CS# DQS DQ U31 DQ DQ DQ DQ DQ DQ DQ DQS6 DQS1 DM6 DM1 DQ24 DQ25 DQ26 DQ27 DQ28 DQ29 DQ30 DQ31 DM CS# DQS DQ U40 DQ DQ DQ DQ DQ DQ DQ DM CS# DQS DQ U41 DQ DQ DQ DQ DQ DQ DQ 120 CK0 CK0# BA0, BA1: DDR SDRAMs U1-U8 BA0, BA1 A0-A12: DDR SDRAMs U1-U8 A0-A12 RAS# CAS# RAS#: DDR SDRAMs U1-U8 CKE0 CKE0: DDR SDRAMs U10-U80 CKE1 CKE1: DDR SDRAMs U11-U81 WE# WE#: DDR SDRAMs U1-U8 120 CAS#: DDR SDRAMs U1-U8 SERIAL PD SCL WP U20 A0 A1 A2 SDA SA0 SA1 SA2 V826664G24S Rev. 1.0 August 2002 DDR SDRAM X 8 3 CK1 CK1# DDR SDRAM X 8 CK2 CK2# 120 VDDQ DDR SDRAMs VDD DDR SDRAMs VREF DDR SDRAMs VSS DDR SDRAMs V826664G24S MOSEL VITELIC Pin Configurations (Front Side/Back Side) Pin Front Pin Front Pin Front Pin Back Pin Back Pin Back 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 VREF VSS DQ0 DQ1 VDD DQS0 DQ2 VSS DQ3 DQ8 VDD DQ9 DQS1 VSS DQ10 DQ11 VDD CK0 CK0 VSS 67 69 71 73 75 77 79 81 83 85 87 89 91 93 95 97 99 101 103 105 107 109 111 113 115 117 119 121 123 125 127 129 131 133 DQ27 VDD CB0 CB1 VSS DQS8 CB2 VDD CB3 DU VSS CK2 CK2 VDD CKE1 DU(A13) A12 A9 VSS A7 A5 A3 A1 VDD A10/AP BA0 WE S0 DU VSS DQ32 DQ33 VDD DQS4 135 137 139 141 143 145 147 149 151 153 155 157 159 161 163 165 167 169 171 173 175 177 179 181 183 185 187 189 191 193 195 197 199 DQ34 VSS DQ35 DQ40 VDD DQ41 DQS5 VSS DQ42 DQ43 VDD VDD VSS VSS DQ48 DQ49 VDD DQS6 DQ50 VSS DQ51 DQ56 VDD DQ57 DQS7 DQ58 DQ58 DQ59 VDD SDA SCL VDDSPD VDDID 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 VREF VSS DQ4 DQ5 VDD DM0 DQ6 VSS DQ7 DQ12 VDD DQ13 DM1 VSS DQ14 DQ15 VDD VDD VSS VSS 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 DQ31 VDD CB4 CB5 VSS DM8 CB6 VDD CB7 DU/(RESET) VSS VSS VDD VDD CKE0 DU(BA2) A11 A8 VSS A6 A4 A2 A0 VDD BA1 RAS CAS S1 DU VSS DQ36 DQ37 VDD DM4 136 138 140 142 144 146 148 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 182 184 186 188 190 192 194 196 198 200 DQ38 VSS DQ39 DQ44 VDD DQ45 DM5 VSS DQ46 DQ47 VDD CK1 CK1 VSS DQ52 DQ53 VDD DM6 DQ54 VSS DQ55 DQ60 VDD DQ61 DM7 VSS DQ62 DQ63 VDD SA0 SA1 SA2 DU Key 41 43 45 47 49 51 53 55 57 59 61 63 65 DQ16 DQ17 VDD DQS2 DQ18 VSS DQ19 DQ24 VDD DQ25 DQS3 VSS DQ26 Key 42 44 46 48 50 52 54 56 58 60 62 64 66 DQ20 DQ21 VDD DM2 DQ22 VSS DQ23 DQ28 VDD DQ29 DM3 VSS DQ30 Notes: * These pins are not used in this module. Pin Names Pin Pin Description Pin Pin Description A0~A12 Address Input (Multiplexed) VDD Power Supply (2.5V) BA0~BA1 Bank Select Address VDDQ Power Supply for DQS(2.5V) DQ0~DQ63 Data Input/Output VSS Ground DQS0~DQS7 Data Strobe Input/Output VREF Power Supply for Reference CK0~CK2, CK0~CK2, Clock Input VDDSPD CKE0, CKE1 Clock Enable Input Serial EEPOM Power Supply (2.3V to 3.6V) CS0 , CS1 Chip Select Input SDA Serial Data I/O RAS Row Address Strobe SCL Serial Clock CAS Column Address Strobe SA0~2 Address in EEPROM WE Write Enable VDDID VDD Identification Flag DM0~DM7 Data - In Mask NC No Connection V826664G24S Rev. 1.0 August 2002 4 V826664G24S MOSEL VITELIC Serial Presence Detect Information Bin Sort: A1 (PC1600 @ CL2) B0 (PC2100B @ CL2.5) B1 (PC2100A @ CL2) C0 (PC2700 @ CL2.5) Function Supported Byte # Function described A1 B0 B1 Hex value C0 A1 B0 0 Defines # of Bytes written into serial memory at module manufacturer 128bytes 80h 1 Total # of Bytes of SPD memory device 256bytes 08h 2 Fundamental memory type SDRAM DDR 07h 3 # of row address on this assembly 13 0Dh 4 # of column address on this assembly 10 0Ah 5 # of module Rows on this assembly 2 Bank 02h 6 Data width of this assembly 64 bits 40h 7 .........Data width of this assembly - 00h 8 VDDQ and interface standard of this assembly SSTL 2.5V 04h 9 DDR SDRAM cycle time at CAS Latency =2.5 10 DDR SDRAM Access time from clock at CL=2.5 11 DIMM configuration type(Non-parity, Parity, ECC) 12 Refresh rate & type 13 Primary DDR SDRAM width 14 Error checking DDR SDRAM data width 15 Minimum clock delay for back-to-back random column address 16 DDR SDRAM device attributes : Burst lengths supported 17 DDR SDRAM device attributes : # of banks on each DDR SDRAM 18 8ns 7.5ns 7ns 6ns ±0.8ns ±0.75ns ±0.75ns ±0.70ns 75h 70h 60h 80h 75h 75h 70h 00h 7.8us & Self refresh 82h x8 08h N/A 00h tCCD =1CLK 01h 2,4,8 0Eh 4 banks 04h DDR SDRAM device attributes : CAS Latency supported 2,2.5 0Ch 19 DDR SDRAM device attributes : CS Latency 0CLK 01h 20 DDR SDRAM device attributes : WE Latency 1CLK 02h 21 DDR SDRAM module attributes Differential clock / non Registered 20h 22 DDR SDRAM device attributes : General +/-0.2V voltage tolerance 00h 23 DDR SDRAM cycle time at CL =2 24 DDR SDRAM Access time from clock at CL =2 25 DDR SDRAM cycle time at CL =1.5 - - - - 00h 26 DDR SDRAM Access time from clock at CL =1.5 - - - - 00h 27 Minimum row precharge time (=tRP) 20ns 20ns 20ns 18ns 50h 28 Minimum row activate to row active delay(=tRRD ) 15ns 15ns 15ns 12ns 3Ch V826664G24S Rev. 1.0 August 2002 10ns 7.5ns 7.5ns ±0.8ns ±0.75ns ±0.75ns ±0.70ns 5 C0 80h Non-parity, ECC 10ns B1 A0h A0h 75h 75h 80h 75h 75h 70h 50h 50h 48h 3Ch 3Ch 30h V826664G24S MOSEL VITELIC Serial Presence Detect Information (cont.) Function Supported Byte # Function described Hex value A1 B0 B1 C0 A1 B0 B1 C0 29 Minimum RAS to CAS delay(=tRCD ) 20ns 20ns 20ns 18ns 50h 50h 50h 48h 30 Minimum active to precharge time(=tRAS) 50ns 45ns 45ns 42ns 32h 2Dh 2Dh 2Ah 31 Module ROW density 32 Command and address signal input setup time 1.1ns 0.9ns 0.9ns 0.75ns B0h 90h 90h 75h 33 Command and address signal input hold time 1.1ns 0.9ns 0.9ns 0.75ns B0h 90h 90h 75h 34 Data signal input setup time 0.6ns 0.5ns 0.5ns 0.45ns 60h 50h 50h 45h 35 Data signal input hold time 0.6ns 0.5ns 0.5ns 0.45ns 60h 50h 50h 45h 36-40 256MB 40h Superset information (may be used in future) 00h 41 SDRAM device minimum active to active/auto-refresh time (=tRC) 70ns 65ns 65ns 60ns 46h 41h 41h 3Ch 42 SDRAM device minimum active to autorefresh to active/auto-refresh time (=tRFC ) 80ns 75ns 75ns 72ns 50h 4Bh 4Bh 48h 43 SDRAM device maximum device cycle time (=tCK MAX) 12ns 12ns 12ns 12ns 30h 30h 30h 30h 44 SDRAM device maximum skew between DQS and DQ signals (=tDQSQ) 0.6ns 0.5ns 0.5ns 0.45ns 3Ch 32h 32h 2Dh 45 SDRAM device maximum read datahold skew factor (=tQHS) 0.75ns 0.75ns 0.60ns A0h 75h 75h 60h F3h 4Ch 46-61 Superset information (may be used in future) 62 SPD data revision code 63 Checksum for Bytes 0 ~ 62 64 Manufacturer JEDEC ID code 65 -71 72 73-90 1ns - 00h Initial release 00h Mosel Vitelic ....... Manufacturer JEDEC ID code E8h 23h 40h 00h Manufacturing location 02=Taiwan 05=China 0A=S-CH Module part number (ASCII) V826664G24S 91 Manufacturer revison code (For PCB) 0 00 92 Manufacturer revison code (For component) 0 00 93 Manufacturing date (Week) - - 94 Manufacturing date (Year) - - Assembly serial # - - 99~127 Manufacturer specific data (may be used in future) Undefined 00h 128~25 Open for customer use 5 Undefined 00h 95~98 V826664G24S Rev. 1.0 August 2002 6 V826664G24S MOSEL VITELIC DC Operating Conditions (TA = 0 to 70°C, Voltage referenced to VSS = 0V) Parameter Symbol Min Typ. Max Unit Power Supply Voltage VDD 2.3 2.5 2.7 V Power Supply Voltage VDDQ 2.3 2.5 2.7 V Input High Voltage VIH VREF + 0.15 - VDDQ + 0.3 V Input Low Voltage VIL -0.3 - VREF - 0.15 V I/O Termination Voltage VTT VREF - 0.04 VREF VREF + 0.04 V VREF 1.15 1.25 1.35 V II -2 - 2 µA Output Leakage Current IOz -5 - 5 µA Output High Current (VOUT = 1.95V) IOH -16.8 - - mA Output Low Current (VOUT = 0.35V) IOL 16.8 - - mA Reference Voltage Input Leakage Current Note 1 2 3 Notes: 1. VDDQ must not exceed the level of VDD . 2. VIL (min) is acceptable -1.5V AC pulse width with <=5ns of duration. 3. The value of VREF is approximately equal to 0.5VDDQ. AC Operating Conditions (TA = 0 to 70 °C, Voltage referenced to VSS = 0V) Parameter Symbol Min Input High (Logic 1) Voltage, DQ, DQS and DM signals VIH(AC) VREF + 0.31 Input Low (Logic 0) Voltage, DQ, DQS and DM signals VIL(AC) Input Differential Voltage, CK and CK inputs VID(AC) Input Crossing Point Voltage, CK and CK inputs VIX(AC) Max Unit Note V VREF - 0.31 V 0.7 VDDQ + 0.6 V 1 0.5*VDDQ-0.2 0.5*VDDQ+0.2 V 2 Notes: 1. VID is the magnitude of the difference between the input level on CK and the input on CK. 2. The value of VIX is expected to equal 0.5*VDDQ of the transmitting device and must track variations in the DC level of the same. V826664G24S Rev. 1.0 August 2002 7 V826664G24S MOSEL VITELIC AC Operating Test Conditions (TA = 0 to 70°C, Voltage referenced to VSS = 0V) Parameter Value Unit Reference Voltage VDDQ x 0.5 V Termination Voltage VDDQ x 0.5 V AC Input High Level Voltage (VIH, min) VREF + 0.31 V AC Input Low Level Voltage (VIL, max) VREF - 0.31 V VREF V Output Timing Measurement Reference Level Voltage VTT V Input Signal maximum peak swing 1.5 V Input minimum Signal Slew Rate 1 V/ns Termination Resistor (RT) 50 Ohm Series Resistor (R S) 25 Ohm Output Load Capacitance for Access Time Measurement (C L) 30 pF Input Timing Measurement Reference Level Voltage Vtt=0.5*VDDQ RT=50Ω Output Z0=50Ω CLOAD=30pF VREF =0.5*V DDQ Output Load Circuit (SSTL_2) Input/Output Capacitance (VDD = 2.5V, VDDQ = 2.5V, TA = 25°C, f = 1MHz) Parameter Symbol Min Max Unit Input capacitance (A0 ~ A11, BA0 ~ BA1, RAS, CAS, WE) CIN1 36 45 pF Input capacitance (CKE0) CIN2 36 45 pF Input capacitance (CS0) CIN3 34 42 pF Input capacitance (CLK1, CLK2) CIN4 34 38 pF Data & DQS input/output capacitance (DQ 0~DQ63) COUT 8 9 pF Input capacitance (DM0~DM8) CIN5 8 9 pF V826664G24S Rev. 1.0 August 2002 8 V826664G24S MOSEL VITELIC DDR SDRAM IDD SPEC TABLE C0 DDR333@CL=2.5 B1 DDR266@CL=2 B0 DDR266@CL=2.5 A1 DDR200@CL=2 Typical Typical Typical Typical IDD0 880 800 800 640 mA IDD1 1120 1000 1000 800 mA IDD2P 450 380 380 260 mA IDD2F 365 360 360 320 mA IDD2Q 340 280 280 240 mA IDD3P 450 380 380 260 mA IDD3N 460 400 400 320 mA IDD4R 1360 1360 1360 1120 mA IDD4W 1680 1480 1480 1200 mA IDD5 1600 1480 1480 1200 mA Normal 54 54 54 54 mA Low power 30 30 30 30 mA 2800 2600 2600 2120 mA Symbol IDD6 IDD7A Unit Notes Optional * Module IDD was calculated on the basis of component IDD and can be differently measured according to DQ loading cap. Detailed test conditions for DDR SDRAM IDD1 & IDD IDD1 : Operating current: One bank operation 1. Typical Case : Vdd = 2.5V, T=25’ C 2. Worst Case : Vdd = 2.7V, T= 10’ C 3. Only one bank is accessed with tRC(min), Burst Mode, Address and Control inputs on NOP edge are changing once per clock cycle. lout = 0mA 4. Timing patterns - DDR200(100Mhz, CL=2) : tCK = 10ns, CL2, BL=4, tRCD = 2*tCK, tRAS = 5*tCK Read : A0 N R0 N N P0 N A0 N - repeat the same timing with random address changing *50% of data changing at every burst - DDR266B(133Mhz, CL=2.5) : tCK = 7.5ns, CL=2.5, BL=4, tRCD = 3*tCK, tRC = 9*tCK, tRAS = 5*tCK Read : A0 N N R0 N P0 N N N A0 N - repeat the same timing with random address changing *50% of data changing at every burst - DDR266A (133Mhz, CL=2) : tCK = 7.5ns, CL=2, BL=4, tRCD = 3*tCK, tRC = 9*tCK, tRAS = 5*tCK Read : A0 N N R0 N P0 N N N A0 N - repeat the same timing with random address changing *50% of data changing at every burst Legend : A=Activate, R=Read, W=Write, P=Precharge, N=NOP V826664G24S Rev. 1.0 August 2002 9 V826664G24S MOSEL VITELIC AC Characteristics (AC operating conditions unless otherwise noted) (PC333) Parameter (PC266A) (PC266B) (PC200) Symbol Min Max Min Max Min Max Min Row Cycle Time tRC 60 - 65 - 65 - 70 - ns Auto Refresh Row Cycle Time tRFC 72 - 75 - 75 - 80 - ns Row Active Time tRAS 42 120K 45 120K 45 120K 50 120K ns Row Address to Column Address Delay tRCD 18 - 20 - 20 - 20 - ns Row Active to Row Active Delay tRRD 12 - 15 - 15 - 15 - ns Column Address to Column Address Delay tCCD 1 - 1 - 1 - 1 - CLK Row Precharge Time tRP 18 - 20 - 20 - 20 - ns Write Recovery Time tWR 12 - 15 - 15 - 15 - ns Last Data-In to Read Command tDRL 1 - 1 - 1 - 1 - CLK Auto Precharge Write Recovery + Precharge Time tDAL 35 - 35 - 35 - 35 - ns CAS Latency = 2.5 tCK 6 12 7 12 7.5 12 8 12 ns 7.5 12 7.5 12 10 12 10 12 ns System Clock Cycle Time CAS Latency = 2 Max Unit Note Clock High Level Width tCH 0.45 0.55 0.45 0.55 0.45 0.55 0.45 0.55 CLK Clock Low Level Width tCL 0.45 0.55 0.45 0.55 0.45 0.55 0.45 0.55 CLK Data-Out edge to Clock edge Skew tAC -0.75 0.75 -0.75 0.75 -0.75 0.75 -0.8 0.8 ns DQS-Out edge to Clock edge Skew tDQSCK -0.75 0.75 -0.75 0.75 -0.75 0.75 -0.8 0.8 ns DQS-Out edge to Data-Out edge Skew tDQSQ - 0.45 - 0.5 - 0.5 - 0.6 ns Data-Out hold time from DQS tQH tHPmin -0.75ns - tHPmin -0.75ns - tHPmin -0.75ns - tHPmin -0.75ns - ns 1 Clock Half Period tHP tCH/L min - tCH/L min - tCH/L min - tCH/L min - ns 1 Input Setup Time (fast slew rate) tIS 0.75 - 0.9 - 0.9 - 1.1 - ns 2,3,5,6 Input Hold Time (fast slew rate) tIH 0.75 - 0.9 - 0.9 - 1.1 - ns 2,3,5,6 Input Setup Time (slow slew rate) tIS 0.8 - 1.0 - 1.0 - 1.1 - ns 2,4,5,6 Input Hold Time (slow slew rate) tIH 0.8 - 1.0 - 1.0 - 1.1 - ns 2,4,5,6 Write DQS High Level Width tDQSH 0.4 0.6 0.4 0.6 0.4 0.6 0.4 0.6 CLK Write DQS Low Level Width tDQSL 0.4 0.6 0.4 0.6 0.4 0.6 0.4 0.6 CLK CLK to First Rising edge of DQS-In tDQSS 0.75 1.25 0.75 1.25 0.75 1.25 0.75 1.25 CLK Data-In Setup Time to DQS-In (DQ & DM) tDS 0.45 - 0.5 - 0.5 - 0.6 - ns 7 Data-in Hold Time to DQS-In (DQ & DM) tDH 0.45 - 0.5 - 0.5 - 0.6 - ns 7 DQ & DM Input Pulse Width tDIPW 1.75 - 1.75 - 1.75 - 2 - ns Read DQS Preamble Time tRPRE 0.9 1.1 0.9 1.1 0.9 1.1 0.9 1.1 CLK Read DQS Postamble Time tRPST 0.4 0.6 0.4 0.6 0.4 0.6 0.4 0.6 CLK tWPRES 0 - 0 - 0 - 0 - CLK Write DQS Preamble Setup Time V826664G24S Rev. 1.0 August 2002 10 V826664G24S MOSEL VITELIC AC Characteristics (cont.) (PC333) Parameter (PC266A) (PC266B) (PC200) Symbol Min Max Min Max Min Max Min tWPREH 0.25 - 0.25 - 0.25 - 0.25 - CLK Write DQS Postamble Time tWPST 0.4 0.6 0.4 0.6 0.4 0.6 0.4 0.6 CLK Mode Register Set Delay tMRD 2 - 2 - 2 - 2 - CLK Power Down Exit Time tPDEX 10 - 10 - 10 - 10 - ns Exit Self Refresh to Non-Read Command tXSNR 75 - 75 - 75 - 80 - ns Exit Self Refresh to Read Command tXSRD 200 - 200 - 200 - 200 - CLK Average Periodic Refresh Interval tREFI - 7.8 - 7.8 - 7.8 - 7.8 us Write DQS Preamble Hold Time Max Unit Note Notes: 1. This calculation accounts for tDQSQ(max), the pulse width distortion of on-chip circuit and jitter. 2. Data sampled at the rising edges of the clock : A0~A11, BA0~BA1, CKE, CS, RAS, CAS, WE. 3. For command/address input slew rate >=1.0V/ns 4. For command/address input slew rate >=0.5V/ns and <1.0V/ns 5. CK, CK slew rates are >=1.0V/ns 6. These parameters guarantee device timing, but they are not necessarily tested on each device, and they may be guaranteed by design or tester correlation. 7. Data latched at both rising and falling edges of Data Strobes(DQS) : DQ, DM 8. Minimum of 200 cycles of stable input clocks after Self Refresh Exit command, where CKE is held high, is required to complete Self Refresh Exit and lock the internal DLL circuit of DDR SDRAM. Absolute Maximum Ratings Parameter Symbol Rating Unit Ambient Temperature TA 0 ~ 70 °C Storage Temperature TSTG -55 ~ 125 °C VIN , V OUT -0.5 ~ 3.6 V VDD -0.5 ~ 3.6 V VDDQ -0.5 ~ 3.6 V Output Short Circuit Current IOS 50 mA Power Dissipation PD 16 W TSOLDER 260 • 10 °C • Sec Voltage on Any Pin relative to VSS Voltage on VDD relative to VSS Voltage on VDDQ relative to V SS Soldering Temperature • Time Note: Operation at above absolute maximum rating can adversely affect device reliability V826664G24S Rev. 1.0 August 2002 11 8 V826664G24S MOSEL VITELIC Package Dimensions Units : Inches (Millimeters) 2.70 (67.60) 2.50 (63.60) 39 41 0.456 11.40 0.086 2.15 199 1.896 (47.40) 0.17 (4.20) 0.096 (2.40) 0.07 (1.8) 0.79 (20.00) 0.24 (6.0) 1 Z 1.25 (31.75) Full R 2x 0.16 ± 0.039 (4.00 ± 0.10) 2- 0.07 (1.80) Y 0.098 2.45 200 0.157 Min (4.00 Min) 0.157 Min (4.00 Min) 0.150 Max (3.80 Max) 0.04 ± 0.0039 (1.00 ± 0.10) 0.16 ± 0.0039 (4.00 ± 0.10) 0.04 ± 0.0039 (1.00 ± 0.1) Detail Z 0.018 ± 0.001 (0.45 ± 0.03) 0.01 (0.25) 0.024 TYP (0.60 TYP) Detail Y Tolerances : ±.006(.15) unless otherwise specified V826664G24S Rev. 1.0 August 2002 0.102 Min 40 42 (2.55 Min) 2 12 V826664G24S MOSEL VITELIC Label Information Module Density MOSEL VITELIC Part Number Criteria of PC2700 DIMM manufacture date code V826664G24SXXX-XX 512MB CLXX PC2700U-2533-X-XX XXXX-XXXXXXX Assembly in Taiwan PC2700 U - 2533 - X - X CAS Latency X Revision number of the reference design used "1" : 1st Revision "2" : 2nd Revision blank : not applicable UNBUFFERED DIMM CL = 2.5 (CLK) tRCD = 3 (CLK) tRP = 3 (CLK) Gerber file used for this design "A" : Reference design for raw card A is used for this assembly SPD Revision "B" : Reference design for raw card B is used for this assembly "C" : Reference design for raw card C is used for this assembly "Z" : None of the reference design were used for this assembly Module Density MOSEL VITELIC Part Number Criteria of PC2100 or PC1600 DIMM manufacture date code V826664G24SXXX-XX 512MB CLXX PC2100U-2533-XXX-X XXXX-XXXXXXX Assembly in Taiwan PC2100 U - 2533 - XX X - X UNBUFFERED SODIMM Gerber file CL = 2.5 (CLK) tRCD = 3 (CLK) tRP = 3 (CLK) V826664G24S Rev. 1.0 August 2002 SPD Revision CYCLE TIME 13 CAS Latency V826664G24S MOSEL VITELIC WORLDWIDE OFFICES U.S.A. TAIWAN SINGAPORE UK & IRELAND 3910 NORTH FIRST STREET SAN JOSE, CA 95134 PHONE: 408-433-6000 FAX: 408-433-0952 7F, NO. 102 MIN-CHUAN E. ROAD, SEC. 3 TAIPEI PHONE: 886-2-2545-1213 FAX: 886-2-2545-1209 10 ANSON ROAD #23-13 INTERNATIONAL PLAZA SINGAPORE 079903 PHONE: 65-6323-1801 FAX: 65-6323-7013 NO 19 LI HSIN ROAD SCIENCE BASED IND. PARK HSIN CHU, TAIWAN, R.O.C. PHONE: 886-3-579-5888 FAX: 886-3-566-5888 JAPAN SUITE 50, GROVEWOOD BUSINESS CENTRE STRATHCLYDE BUSINESS PARK BELLSHILL, LANARKSHIRE, SCOTLAND, ML4 3NQ PHONE: 44-1698-748515 FAX: 44-1698-748516 ONZE 1852 BUILDING 6F 2-14-6 SHINTOMI, CHUO-KU TOKYO 104-0041 PHONE: 03-3537-1400 FAX: 03-3537-1402 U.S. SALES OFFICES WEST CENTRAL / EAST 3910 NORTH FIRST STREET SAN JOSE, CA 95134 PHONE: 408-433-6000 FAX: 408-433-0952 604 FIELDWOOD CIRCLE RICHARDSON, TX 75081 PHONE: 214-352-3775 FAX: 214-904-9029 © Copyright , MOSEL VITELIC Corp. Printed in U.S.A. MOSEL VITELIC subjects its products to normal quality control sampling techniques which are intended to provide an assurance of high quality products suitable for usual commercial applications. MOSEL VITELIC does not do testing appropriate to provide 100% product quality assurance and does not assume any liability for consequential or incidental arising from any use of its products. If such products are to be used in applications in which personal injury might occur from failure, purchaser must do its own quality assurance testing appropriate to such applications. The information in this document is subject to change without notice. MOSEL VITELIC makes no commitment to update or keep current the information contained in this document. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of MOSEL-VITELIC. V826664G24S Rev. 1.0 August 2002 14