LA VDE 2 Form A slim power relay LA RELAYS FEATURES 12.0 .472 24.0 .945 25.0 .984 mm inch tween contact and coil: Min. 6 mm .236 inch(In compliance with IEC65) • Surge withstand voltage between contact and coil: 10,000 V or more. 4. High noise immunity realized by the card separation structure between contact and coil 5. Conforms to the various safety standards • UL/CSA, VDE, TÜV, SEMKO, SEV approved 1. 2 Form A slim type 24(L) × 12(W) × 25(H) mm .945(L)×.472(W)×.984(H) inch 2. 3A type and 5A TV type 3A type: Contact reliability and break performance best suited for protecting and switching speakers. 5A TV type: Tough against inrush current and optimal for turning on and off the power supply. Rated TV-4 (UL/CSA). 3. High insulation resistance • Creepage distance and clearances be- SPECIFICATIONS Contact Characteristics Type Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) 3A rated 5A TV rated 2 Form A Contact material Rating (resistive load) Expected life (min. operations) Max. 50 mΩ Max. 100 mΩ Gold-clad silver alloy Silver alloy Nominal switching 3 A 125 V AC 5 A 277 V AC capacity Max. switching power 625 VA 1,385 V A Max. switching voltage 125 V AC 277 V AC Max. switching current 5 A (AC) Mechanical (at 180 cpm) 106 Electrical (at 20 cpm) 5 × 104 (at rated load) (ON: OFF=1.5s: 1.5s) Type Max. operating speed Initial insulation resistance*1 Between contact sets Initial *2 Between open contacts breakdown Between contact and voltage coil Surge voltage between contact and coil*3 Operate time*4 (at nominal voltage) Release time (with diode)*4 (at nominal voltage) Nominal operating power 530 mW Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section. *2 Detection current: 10mA *3 Wave is standard shock voltage of ±1.2 × 50ms according to JEC-212-1981 *4 Excluding contact bounce time. *5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs *6 Half-wave pulse of sine wave: 6 ms *7 Detection time: 10 µs *8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61). Shock resistance Functional*5 Destructive*6 Functional*7 Vibration resistance Destructive Conditions for operation, transport and storage*8 (Not freezing and condensing at low temperature) Unit weight 5A TV rated 20 cpm Min. 1,000 MΩ (at 500 V DC) 1,000 Vrms for 1 min. 1,000 Vrms for 1 min. 4,000 Vrms for 1 min. Min. 10,000 V Max. 15ms (at 20°C 68°F) Max. 15ms (at 20°C 68°F) Max. 45°C with nominal coil voltage and at 3 A contact carrying current Temperature rise (at 70°C) Coil 3A rated Ambient temp. Humidity Air pressure Max. 45°C with nominal coil voltage and at 5 A contact carrying current Min. 200 m/s2{approx. 20 G} Min. 1,000 m/s2{approx. 100 G} 10 to 55Hz at double amplitude of 1.5mm 10 to 55Hz at double amplitude of 1.5mm –40°C to +70°C –40°F to +158°F 5 to 85% R.H. 86 to 106 kPa Approx. 13 g .46 oz ORDERING INFORMATION Ex. A LA 2 P F 12 Product name Contact arrangement Contact capacity Protective construction Coil voltage(V DC) LA 2: 2 Form A Nil: 3A P: 5A TV-4 F: Flux-resistant type 12, 24 UL/CSA, VDE, TÜV, SEMKO, TV-4 approved type is standard. Notes: 1. Standard packing Carton: 100 pcs. Case: 500 pcs. 2. 4.5V, 5V, 9V and 18V DC types are also available. Please consult us for details. 275 LA TYPES AND COIL DATA (at 20°C 68°F) Part No. 3 A type 5A TV type Nominal voltage, V DC ALA2F12 ALA2F24 ALA2PF12 ALA2PF24 12 24 Pick-up voltage, V DC (max.) Drop-out voltage, V DC (min.) Coil resistance, Ω (±10%) (Initial) 9 (Initial) 18 (Initial) 0.6 (Initial) 1.2 272 1,087 Nominal operating current, mA (±10%) 44.2 22.1 Nominal operating power, mW 530 530 Maximum allowable voltage, V DC 15.6 31.2 DIMENSIONS mm inch PC board pattern (Bottom view) 2-0.9 dia 2-.035 dia 15.0 .591 5.0 .197 Max. 25.0 .984 7.5 .295 0.5 .020 Tolerance : ±0.1 ±.004 4 .157 0.5 0.3 .020 .012 1.65 .065 Max. 24 5.0 .945 .197 15.0 .591 4-1.3 dia 4-.051 dia Schematic (Bottom view) 0.4 .016 Max. 12 .472 1.0 .039 Dimension: Max. 1mm .039 inch: 1 to 3mm .039 to .118 inch: Min. 3mm .118 inch: 7.5 .295 1.0 .039 General tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 REFERENCE DATA 1. Max. switching power (AC resistive load) 2-(1). Life curve (250 V AC resistive load) ALA2PF12 3 250V AC resistive load 10 10 ALA2F12 1 100 300 Contact voltage, V 0 1 2 3 3-(1). Coil temperature rise 3-(2). Coil temperature rise Sample: ALA2F12, 6 pcs. Measured portion: coil inside Contact current: 0 A, 3A Sample: ALA2PF12, 6 pcs. Measured portion: coil inside Contact current: 0 A, 5A 50 50 20°C 3A 20°C 0A 40 70°C 3A 70°C 0A 35 30 25 20 40 5 5 100 120 Coil applied voltage, %V 0 3 Contact current: ALA2F=3A ALA2PF=5A 20 10 2 4. Ambient temperature characteristics and coil applied voltage 25 15 80 1 Contact current, A 30 10 0 0 70°C 5A 70°C 0A 35 15 0 1 5 200 20°C 5A 20°C 0A 45 Temperature rise, °C 45 4 Contact current, A Coil applied voltage, %V 0 Temperature rise, °C 125V AC resistive load Life, ×104 5 Life, ×104 Contact current, A 100 100 10 276 2-(2). Life curve (125 V AC resistive load) Allowable ambient temperatures against % coil voltages (max. inside the coil temperature set as 115°C 239°F) 150 100 50 0 80 100 120 Coil applied voltage, %V 0 0 20 40 60 Ambient temperature, °C 80 LA Change of pick-up and drop-out voltage Circuit: NO COM NO COM 80 Pick-up voltage 5-(2). Electrical life test (5 A 250 V AC, resistive load) 40 Drop-out voltage NO COM NO COM Pick-up and drop-out voltage, %V Contact welding detection and Miscontacting detection circuit Max. x Min. 20 2.5 No. of operations, ×104 5 Change of contact resistance 50 Pick-up voltage 60 Max. x Min. 40 40 Max. 30 x Min. 20 Drop-out voltage Max. x Min. 20 2.5 No. of operations, ×104 10 0 0 5 2.5 5 No. of operations, ×104 Change of pick-up and drop-out voltage Pick-up and drop-out voltage, %V Tested sample: ALA2PF12, 6 pcs. • Overload test Load: 6.0 A 120 V AC (60 Hz), Inrush: 91 A Operation frequency: 10 times/min (ON: OFF = 1 s: 5 s) No. of operations: 50 ope. • Endurance test Load: 4A 120 V AC (60 Hz), Inrush: 65 A Operation frequency: 10 times/min (ON: OFF = 1 s: 5 s) No. of operations: 25,000 ope. 30 0 0 5 80 0 0 G 5-(3). Electrical life test (UL lamp load test TV-4) 2.5 No. of operations, ×104 40 10 100 Circuit: 12V DC Max. x Min. 20 Change of pick-up and drop-out voltage Sample: ALA2PF12, 6 pcs. Operation frequency: 20 times/min. (ON/OFF = 1.5s: 1.5s) Ambient temperature: 20°C 68°F 250V AC Max. x Min. 60 0 0 G 50 Contact resistance, mΩ 125V AC Contact welding detection and Miscontacting detection circuit 100 Change of contact resistance 50 100 80 Pick-up voltage Max. x Min. 60 40 Drop-out voltage Max. x Min. 20 0 0 2.5 No. of operations, ×104 Contact resistance, mΩ 12V DC Change of contact resistance Contact resistance, mΩ Sample: ALA2F12, 6 pcs. Operation frequency: 20 times/min. (ON/OFF = 1.5s: 1.5s) Ambient temperature: 20°C 68°F Pick-up and drop-out voltage, %V 5-(1). Electrical life test (3 A 125 V AC, resistive load) 40 30 20 Max. 10 x Min. 0 0 2.5 No. of operations, ×104 For Cautions for Use, see Relay Technical Information (Page 48 to 76). 9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, 277 Ltd. Go To Online Catalog