Compact & Slim 2 Form C Non-polarized Relay HX-RELAYS FEATURES 15.0 .591 • Compact size of (W) 7.4 × (L) 15.0 × (H) 9.4 mm (W) .291× (L) .591× (H) .370 inch. • Surge withstand voltage of 1,500 V (between contact and coil) Conforms to FCC Part 68. 7.4 .291 9.4 .370 • High-density mounting is possible • High reliability The use of a gold-clad bifurcated structure for the movable contacts, and a low gas material for the forming materials and coil wiring ensures high contact reliability. mm inch SPECIFICATIONS Contact Characteristics Arrangement 2 Form C Initial contact resistance Max. 100 mΩ (By voltage drop 6 V DC 1 A) Contact material Gold-clad silver alloy Nominal switching 1 A 30 V DC, 0.3 A 125 V AC capacity (resistive load) Max. switching power 30 W (DC), 37.5 VA (AC) (resistive load) Rating Max. switching voltage 110 V DC, 125 V AC Max. switching current 1A Min. switching capability ❇1 1 mA 1 V DC Nominal operating power 320 mW Mechanical (at 180 cpm) 107 Expected 105 life (min. Electrical (at 20 cpm) (1 A 30 V DC, operations) 0.3 A 125 V AC resistive) Between contacts Initial breakdown voltage Between contact and coil Between contacts sets Temperature rise*2 Operate time*3 (at 20°C 68°F) Release time(without diode)*3 (at 20°C 68°F) Functional*4 Shock resistance Destructive*5 Functional*6 Vibration resistance Destructive Note: ❇1This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section. *2 By resistive method, nominal voltage applied to the coil; contact carrying current: 1A. *3 Nominal voltage applied to the coil, excluding contact bounce time. *4 Half- wave pulse of sine wave: 11ms, detection time: 10µs *5 Half- wave pulse of sine wave: 6ms *6 Detection time: 10µs *7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61) TYPICAL APPLICATIONS • Telephone exchange, transmission equipment • Communications devices • Measurement devices • Home appliances, and audio/visual equipment • Office equipment Min. 1,000 MΩ (at 500 V DC) 750 V rms for 1 min. Initial insulation*1 resistance Conditions for opetation, transport and storage*7 Ambient temperature Humidity Atmospheric pressure Unit weight 1,000 V rms for 1 min. 1,000 V rms for 1 min. Max. 60°C Max. 6 ms (Approx. 4 ms) Max. 5 ms (Approx. 3 ms) Min. 100 m/s2 {10G} Min. 1,000 m/s2 {100G} 10 to 55 Hz at double amplitude of 1.0 mm 10 to 55 Hz at double amplitude of 1.5 mm –40 to +70°C –40 to +158°F 5 to 85% R.H. 86 to 106 kPa Approx. 2g .07 oz ORDERING INFORMATION Ex. HX 2 3V Contact arrangement Coil voltage(DC) 2: 2 Form C 1.5, 3, 4.5, 5, 6, 9, 12, 24 V Note: 2,500V Surge (Bellcore) type is also available. Please consult us for details. 183 HX TYPES AND COIL DATA Contact arrangement Coil rating, V DC 2 Form C 1.5 3 4.5 5 6 9 12 24 Part No. Standard PC board terminal arrangement HX2-1.5V HX2-3V HX2-4.5V HX2-5V HX2-6V HX2-9V HX2-12V HX2-24V Pick-up voltage, V DC (max.) (at 20°C 68°F) Drop-out voltage, V DC (min.) (at 20°C 68°F) Normal operating current, mA (±10%) (at 20°C 68°F) Coil Resistance, ohm (±10%) (at 20°C 68°F) Nominal operating power, mW Max. allowable voltage, V DC (at 70°C 158°F) 1.13 2.25 3.38 3.75 4.5 6.75 9 18 0.15 0.3 0.45 0.5 0.6 0.9 1.2 2.4 214 107 71.1 64.0 53.6 35.6 26.7 13.3 7.0 28.1 63.3 78.1 112 253 450 1,800 320 320 320 320 320 320 320 320 1.65 3.3 4.95 5.5 6.6 9.9 13.2 26.4 Standard packing: Tube; 40 pcs.; Case : 1,000 pcs. DIMENSIONS mm inch 1. Standard PC board terminal type PC board pattern (Bottom view) 15.00 .591 10.16 .400 2.54 .100 7.4 .291 9.4 .370 0.45 .018 Schematic (Bottom view) 8-1 dia 8-.039 dia 5.08 .200 2.54 .100 3.5 .138 0.25 .010 0.5 .020 1.15 .138 5.08 .200 1 3 4 5 12 10 9 8 5.08 .200 2.54 .100 General tolerance: ±0.3 ±.012 Tolerance: ±0.1 ±.004 REFERENCE DATA 1. Maximum switching capacity 2. Life curve 3. Mechanical life Switching current, A 2.0 1.0 0.5 0.4 0.3 200 No. of operations, ×104 DC load (cos ϕ = 1) AC load (cos ϕ = 1) 3.0 Ratio against the rated voltage, %V Tested sample: HX2-12 V, 10 pcs. 100 50 30 V DC resistive load 30 20 125 V AC resistive load 0.2 10 20 30 0.2 50 100 200 300 Switching voltage, V 0.4 0.6 0.8 1.0 Switching current, A 100 90 80 Pick-up voltage 70 Max. 60 50 Min. 40 30 Drop-out voltage 20 Max. 10 Min. 0 1.2 100 500 No. of operations, ×104 1,000 4. Electrical life (1 A 30 V DC resistive load) 5. Coil temperature rise Tested sample: HX2-12 V, 6 pcs. Operating frequency: 20 cpm Tested sample: HX2-12 V Measured portion: Inside the coil Ambient temperature: 25°C 77°F, 70°C 158°F Change of contact resistance 100 90 90 80 70 Pick-up voltage Min. 50 40 30 Drop-out voltage Max. 20 0 60 80 70 60 50 40 Max. 30 5 No. of operations, ×104 10 1A 0A 1A 0A 50 40 30 20 10 10 0 70°C 158°F Room temperature (25°C 77°F) Min. 20 Min. 10 184 Max. 60 70 Temperature rise, °C 100 Contact resistance, mΩ Ratio against the rated voltage, %V Change of pick-up and drop-out voltage 5 No. of operations, ×104 10 0 100 110 120 130 140 150 Coil applied voltage, %V HX 6. Operate/release time characteristics 7. Distribution of pick-up and drop-out voltage 8. Ambient temperature characteristics Tested sample: HX2-12V, 10 pcs. Tested sample: HX2-12V, 50 pcs. Tested sample: HX2-12V, 5 pcs. 35 5 4 Set time 3 Max. Min. 2 Reset time Max. Min. 1 0 Variation ratio, % –40 Quantity Set/reset time, msec. 6 80 90 100 110 30 Drop-out voltage 25 Pick-up voltage –40 –20 20 Drop-out voltage –30 –20 –10 Pick-up voltage 0 15 20 40 60 80 Ambient temperature, °C –10 10 –20 5 –30 0 120 Coil applied voltage, %V –40 10 20 30 40 50 60 70 80 90 100 Ratio against the rated voltage, %V 9. Distribution of contact resistance 10.-(1) High frequency characteristics 10.-(2) High frequency characteristics Tested sample: HX2-12V, 25 pcs. (25 × 4 contacts) Isolation characteristics Insertion loss characteristics Isolation, dB Quantity 40 30 Insertion loss, dB 50 100 20 0.5 0.4 0.3 50 0.2 10 0.1 0 20 30 Contact resistance, mΩ 40 10 100 Frequency, MHZ 1,000 0 10 100 Frequency, MHZ 1,000 NOTES 3. Packing style • Packing direction The relay is packed in a tube with the relay orientation mark on the left side, as shown in the figure below. Take note of the relay orientation when mounting relays on the printed circuit board. Orientation (indicates PIN No. 1) stripe 4. Automatic insertion To maintain the internal function of the relay, the chucking pressurre should not exceed the values below. Chucking pressure in direction A: 9.8 N {1 kgf} or less Chucking pressure in direction B: 9.8 N {1 kgf} or less Chucking pressure in direction C: 4.9 N {500 gf} or less A Stopper (gray) Stopper (green) The temperature range is –40 to +70°C –40 to +158°F C B , , , , , ,,,,, 1. Coil operating power Pure DC current should be applied to the coil. The wave form should be rectangular. If it includes ripple, the ripple factor should be less than 5%. However, check it with the actual circuit since the characteristics may be slightly different. The nominal operating voltage should be applied to the coil for more than 10 ms to set/reset the latching type relay. 2. Cleaning In automatic cleaning, cleaning with the boiling method is recommended. Avoid ultrasonic cleaning which subject the relay to high frequency vibrations. It may cause the contacts to stick. lt is recommended that a fluorinated hydrocarbon or other alcoholic solvent be used. Please chuck the portion. Avoid chucking the center of the relay. For Cautions for Use, see Relay Technical Information (Page 48 to 76). 9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, 185 Ltd. Go To Online Catalog