NTE NTE1909

NTE1909
Integrated Circuit
Negative 3 Terminal Voltage Regulator,
–24V, 100mA
Description:
The NTE1909 is a negative 3–terminal voltage regulator in a TO92 type package suitable for numerous
applications requiring up to 100mA. This device features thermal shutdown and current limiting making
the NTE1909 remarkably rugged. In most applications, no external components are required for operation.
The NTE1909 is useful for on–card regulation or any other application where a regulated negative
voltage at a modest current level is needed. This device offers a substantial advantage over the common resistor/zener diode approach.
Features:
D Internal Short–Circuit Current Limiting
D Internal Thermal Overload Protection
D No External Components Required
Absolute Maximum Ratings:
Input Voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –40V
Internal Power Dissipation (Note 1), PD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internally Limited
Operating Junction Temperature Range, Topr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0° to +70°C
Maximum Junction Temperature, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +125°C
Storage Temperature Range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –55° to +150°C
Lead Temperature (During Soldering, 10sec), TL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +300°C
Note 1. Thermal resistance, junction–to–ambient is 180°C/W when mounted with 0.4” leads on a PC
board and 160°C/W when mounted with .250” leads on a PC board.
Electrical Characteristics: (VI = –33V, IO = 40mA, CI = 0.33µF, CO = 0.1µF, 0° ≤ TJ ≤ +125°C,
Note 2 unless otherwise specified)
Parameter
Output Voltage
Line Regulation
Symbol
VO
Regline
Test Conditions
Min
Typ
Max
Unit
TJ = +25°C
–23.0
–24.0
–25.0
V
–38V ≤ VI ≤ –27V, 1mA ≤ IO ≤ 100mA
–22.8
–24.0
–25.2
V
–
–
350
mV
TJ = +25°C, –38V ≤ VI ≤ –27V
Electrical Characteristics (Cont’d): (VI = –33V, IO = 40mA, CI = 0.33µF, CO = 0.1µF,
0° ≤ TJ ≤ +125°C, Note 2 unless otherwise specified)
Parameter
Load Regulation
Quiescent Current
Quiescent Current Change
Symbol
Regload
IB
∆IB
Test Conditions
Min
Typ
Max
Unit
TJ = +25°C, 1mA ≤ IO ≤ 100mA
–
–
200
mV
TJ = +125°C
–
–
6
mA
With line, –38V ≤ VI ≤ –28V
–
–
1.5
mA
With load, 1mA ≤ IO ≤ 40mA
–
–
0.1
mA
Output Noise Voltage
Vn
TJ = +25°C, f = 10Hz to 10kHz
–
200
–
µV
Ripple Rejection
RR
–35V ≤ VI ≤ –29V, f = 120Hz
31
47
–
dB
Dropout Voltage
VDO
TJ = +25°C, IO = 40mA
–
1.7
–
V
Note 2. To ensure constant junction temperature, low duty cycle pulse testing is used.
.135 (3.45) Min
.210
(5.33)
Max
Seating Plane
.500
(12.7)
Min
.021 (.445) Dia Max
GND
VOUT
VIN
.100 (2.54)
.050 (1.27)
.105 (2.67) Max
.205 (5.2) Max
.165 (4.2) Max
.105 (2.67) Max