NTE NTE1906

NTE1906
Integrated Circuit
Positive 3 Terminal Voltage Regulator,
18V, 100mA
Description:
The NTE1906 is a positive 3–terminal voltage regulator in a TO92 type package suitable for numerous
applications requiring up to 100mA. This device features thermal shutdown and current limiting making
the NTE1906 remarkably rugged. In most applications, no external components are required.
The NTE1906 is useful for on–card regulation or any other application where a regulated positive voltage at a modest current level is needed. This device offers a substantial advantage over he common
resistor/zener diode approach.
Features:
D Internal Short–Circuit Current Limiting
D Internal Thermal Overload Protection
D No External Components Required
Absolute Maximum Ratings:
Input Voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35V
Internal Power Dissipation (Note 1), PD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internally Limited
Operating Junction Temperature Range, Topr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0° to +70°C
Maximum Junction Temperature, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +125°C
Storage Junction Temperature Range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –55° to +150°C
Lead Temperature (During Soldring, 10sec), TL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +300°C
Note 1. Thermal resistance, junction–to–ambient is 180°C/W when mounted with 0.4” leads on a PC
board and 160°C/W when mounted with .250” leads on a PC board.
Electrical Characteristics: (VI = 27V, IO = 40mA, CI = 0.33µF, CO = 0.1µF, 0° < TJ < +125°C
unless otherwise specified)
Parameter
Output Voltage
Line Regulation
Symbol
VO
Regline
Test Conditions
Min
Typ
Max
Unit
TJ = +25°C
17.3
18.0
18.7
V
20.7V ≤ VI ≤ 33V, 1mA ≤ IO ≤ 100mA
17.1
18.0
18.9
V
–
–
325
mV
TJ = +25°C, 20.7V ≤ VI ≤ 33V
Electrical Characteristics (Cont’d): (VI = 27V, IO = 40mA, CI = 0.33µF, CO = 0.1µF,
0° < TJ < +125°C unless otherwise specified)
Parameter
Load Regulation
Quiescent Current
Quiescent Current Change
Output Noise Voltage
Long–Term Stability
Symbol
Regload
IB
∆IB
Vn
Test Conditions
Min
Typ
Max
Unit
TJ = +25°C, 1mA ≤ IO ≤ 100mA
–
–
170
mV
TJ = +125°C
–
2
6
mA
With line, 21V ≤ VI ≤ 33V
–
–
1.5
mA
With load, 1mA ≤ IO ≤ 40mA
–
–
0.1
mA
TJ = +25°C, f = 10Hz to 10kHz
–
150
–
µV
–
56
–
mV/1kHrs
∆VO/∆t
Ripple Rejection
RR
f = 120Hz, 23V ≤ VI ≤ 33V
33
48
–
dB
Dropout Voltage
VDO
TJ = +25°C, IO = 40mA
–
1.7
–
V
.135 (3.45) Min
.210
(5.33)
Max
Seating Plane
.500
(12.7)
Min
.021 (.445) Dia Max
VOUT
VIN
GND
.100 (2.54)
.050 (1.27)
.105 (2.67) Max
.205 (5.2) Max
.165 (4.2) Max
.105 (2.67) Max