NTE NTE1912

NTE1912
Integrated Circuit
Positive 3 Terminal Voltage Regulator,
12V, 3A
Description:
The NTE1912 is a 3 terminal fixed positive voltage regulator in a TO3 type package designed for use
in applications requiring a well regulated positive output voltage. Outstanding features include full power
usage up to 3A of load current, internal current limiting, thermal shutdown, and safe area protection on
the chip, providing protection of the series pass Darlington, under most operating conditions. Hermetically sealed steel packages are utilized for high reliability and low thermal resistance. A low–noise temperature stable band–gap reference is the key design factor insuring excellent temperature regulation
of the NTE1912. This coupled to a very low output impedance insures superior load regulation.
Features:
D Guaranteed Power Dissipation: PD = 30W @ TC = 57.5°C
D Guaranteed Input–Output Differential: VIN – VO = +2.5V
D Low Noise, Band Gap Reference
D Remote Sense Capability
D Sample Power Cycled Burn–In
D Guaranteed Thermal Resistance Junction to Case: RΘJC = 2.25°C/W
Absolute Maximum Ratings:
Input Voltage (Note 1), VIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30V
Power Dissipation, PD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internally Limited
Derate Above TC = 57.5°C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 444mW/°C
Operating Junction Temperature Range, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –55° to +150°C
Storage Temperature Range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65° to +150°C
Lead Temperature (During Soldering, 60sec Max), TL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +300°C
Thermal Resistance, Junction to Case, RΘJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.25°C/W
Note 1. Short circuit protection is only assured to VINmax. In case of short circuit, with input–output
voltages approaching VINmax, regulator may require the removal of the input voltage to restart.
Electrical Characteristics: (TJ = +25°C unless otherwise specified)
Parameter
Symbol
Output Voltage
VO
Test Conditions
Min
Typ
Max
Unit
11.05
12.0
13.05
V
2.5
–
–
V
–
–
1.0
% VO
–
–
0.6
% VO
VIN = 15V, IO = 10mA
–
–
20
mA
VIN = 15V to 22V, IO = 10mA to 3A, Note 2
Input–Output Differential
VIN–VO
IO = 3A, TJ = 0 to +125°C
Line Regulation
RegLine
VIN = 15V to 27V, IO = 2A, Note 2
Load Regulation
RegLoad VIN = 17V, IO = 10mA to 3A, Note 2
Quiescent Current
IQ
Quiescent Current Line
IQ(Line)
VIN = 15V to 22V, IO = 10mA
–
–
5
mA
Quiescent Current Load
IQ(Load)
VIN = 15V, IO = 10mA to 3A
–
–
5
mA
Current Limit
ILIM
VIN = 17V, Note 2
–
–
6.5
A
Temperature Coefficient
TC
VIN = 15V, IO = 100mA, TJ = 0 to +125°C
–
–
0.02
% VO/°C
Output Noise Voltage
VN
VIN = 15V, IO = 100mA. TJ = 0 to +125°C, Note 3
–
–
10
µVrms/V
Ripple Attenuation
RA
VIN = 17V, IO = 2A, TJ = 0 to +125°C, Note 4
60
–
–
dB
Power Dissipation
PD
VIN – VO (2.5V to 10V), IO = 10mA to 3A,
TJ = 0 to +125°C
–
–
30
W
Note 2. Low duty cycle pulse testing with Kelvin connections required. Die temperature changes
must be accounted for separatly.
Note 3. BW = 10Hz to 100kHz.
Note 4. Ripple attenuation is specified for a 1Vrms, 120Hz, input ripple. Ripple attenuation is minimum of 60dB at 5V output and is 1dB less for each volt increase in the output voltage.
.135 (3.45) Max
.350 (8.89)
.875 (22.2)
Dia Max
Seating
Plane
.312 (7.93) Min
.040 (1.02)
1.187 (30.16)
VOUT
.665
(16.9)
.215 (5.45)
.156 (3.96) Dia
(2 Holes)
.430
(10.92)
.188 (4.8) R Max
VIN
.525 (13.35) R Max
Common/Case