Imaging D A T A S H E E T Lighting Telecom Machine Vision Illumination Systems MVS-4100, 4200 Machine Vision Strobe Description Features The PerkinElmer Optoelectronics MVS 4100 and MVS 4200 are costeffective strobes for a wide variety of industrial inspection applications. The linear xenon flashlamp, mounted in a reflector for maximum intensity, provides 6 microsecond pulses at flash rates up to 100 Hz. The energy-perflash remains constant at 180 mJ; no range-switching is needed. • Low cost • Compact/light weight • Universal AC input (90–230 VAC, 560/60 Hz) • Long life xenon flashlamp • Flash rates to 100 Hz • Pulse duration 6 µsec These 20 Watt strobes are housed in a convection-cooled, rugged enclosure. Threaded hoses at the bottom of the enclosure allow the unit to be hard mounted. • Internal/external trigger • Convection cooled The MVS 4100 has an optically isolated trigger input and requires an external +5V TTL pulse to flash. The MVS 4200 has an internal oscillator and can be run in either external or internal trigger mode. The MVS 4200 is ideal as a stand-alone unit for “stroboscopic” applications. . www.perkinelmer.com/opto MVS-4100, 4200 Optical Specifications 300 to 1100+ nm Spectral bandwidth (1) Up to 100 Hz (6,000 fpm) Flash rate >108 flashes Flashlamp life (3) Flash duration (2) 6 microseconds Flash to flash variation < 5% Illumination Characteristics Area Illuminated 6 in. x 8 in. 12 in. x 16 in. 20 in. x 23 in. 36 in. x 48 in. Distance 6 inches 1 foot 2 feet 3 feet Note 1: Note 2: Note 3: Note 4: Note 5: Note 6: Photometric 19 lux-sec 5.7 lux-sec 1.5 lux-sec 0.6 lux-sec Radiometric 15 x 10-6 J/cm2 4.5 x 10-6 J/cm2 1.2 x 10-6 J/cm2 0.5 x 10-6 J/cm2 Spectral bandwidth may be extended into the ultraviolet with other flashlamp envelope and enclosure window materials. Contact factory for IR or UV filters. Measured at 1/3 peak value. Prior to light output decreasing to 50% of the initial value. Area where energy is not less than 50% of maximum. Lux-sec = Lumen-sec/m2. Delay between flash command and light output is 8 µsec typical. Electrical Specifications Input voltage Input current Flashlamp voltage Discharge capacitor Discharge energy Discharge power Tirgger input: (1) Trigger Pulse duration 90 - 230 ±10% VAC, 50/60 Hz 2.0 amps maximum 600 volts 1.0 microfarad ± 10% 0.18 Joules (± 10%) 20 watts maximum +5 volt pulse into opto-isolator with 150 ohm nominal series resistor 10 to 100 microseconds Internal oscillator 10 - 100 Hz (10 turn potentiometer) (MVS-4200 only) INTERNAL FLASH RATE 4.88 (124.0) EXT INT INT TRIGGER Physical Specifications AC INPUT ON-OFF SWITCH 8.25 (209.6) 9 PIN CONNECTOR POWER EXTERNAL TRIGGER 2.51 1.50 (63.8) (38.1) 50-60HZ 100-240VAC 2A MAX REAR VIEW 1.88 (47.6) 6.75 (171.5) 0.50 (12.7) 0.56 (14.2) 1/4-20 X .27(6.9) DEEP MOUNTING HOLES 3 PLACES 2.43 (61.7) 0.56 (14.2) For more information e-mail us at [email protected] or visit our web site at www.perkinelmer.com/opto. All values are nominal; specifications subject to change without notice. USA: PerkinElmer Optoelectronics 35 Congress Street Salem, MA 01970 Toll Free: (800) 950-3441 (USA) Phone: (978) 745-3200 Fax: (978) 745-0894 © 2001 PerkinElmer inc. All rights reserved. Europe: PerkinElmer Optoelectronics Wenzel-Jaksch-Str. 31, D-65199 Weisbaden, Germany Phone: +49 (0) 611-492-437 Fax: +49 (0)611-492-159 Asia: PerkinElmer Optoelectronics 47 Ayer Rajah Crescent #06-12 Singapore 139947 Phone: +65 775 2022 Fax: +65 775 1008 0601 www.perkinelmer.com/opto .