PMC PM5362

PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
PM5362
TUPP-PLUS
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR /
PERFORMANCE MONITOR
DATA SHEET
ISSUE 6: MARCH 1998
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
CONTENTS
1
FEATURES ............................................................................................1
2
APPLICATIONS .....................................................................................5
3
REFERENCES.......................................................................................6
4
DESCRIPTION.......................................................................................8
5
PIN DIAGRAM .....................................................................................10
6
BLOCK DIAGRAM ...............................................................................11
7
PIN DESCRIPTION..............................................................................12
8
FUNCTIONAL DESCRIPTION.............................................................41
8.1
INPUT BUS DEMULTIPLEXER.................................................41
8.2
OUTPUT BUS MULTIPLEXER..................................................41
8.3
TRIBUTARY PAYLOAD PROCESSOR......................................42
8.3.1 CLOCK GENERATOR ....................................................42
8.3.2 INCOMING TIMING GENERATOR .................................42
8.3.3 INCOMING MULTIFRAME DETECTOR .........................43
8.3.4 POINTER INTERPRETER .............................................43
8.3.5 PAYLOAD BUFFER ........................................................47
8.3.6 OUTGOING TIMING GENERATOR................................47
8.3.7 POINTER GENERATOR ................................................48
8.4
TRIBUTARY PATH OVERHEAD PROCESSOR ........................51
8.4.1 CLOCK GENERATOR ....................................................52
8.4.2 TIMING GENERATOR....................................................52
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
i
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
8.4.3 ERROR MONITOR .........................................................52
8.4.4 IN-BAND ERROR REPORT ...........................................54
8.4.5 EXTRACT .......................................................................55
8.5
TRIBUTARY TRACE BUFFER...................................................55
8.5.1 CLOCK GENERATOR ....................................................55
8.5.2 TIMING GENERATOR....................................................56
8.5.3 EXTRACT .......................................................................56
8.5.4 ALARM MONITOR..........................................................56
8.5.5 BUFFER .........................................................................57
9
10
11
8.6
JTAG TEST ACCESS PORT .....................................................57
8.7
MICROPROCESSOR INTERFACE...........................................57
8.8
REGISTER MEMORY MAP ......................................................58
NORMAL MODE REGISTER DESCRIPTION .....................................66
9.1
MASTER REGISTERS..............................................................67
9.2
VTPP #1, VTPP #2 AND VTPP #3 REGISTERS ....................109
9.3
RTOP #1, RTOP #2 AND RTOP #3 REGISTERS ...................143
9.4
RTTB #1, RTTB #2 AND RTTB #3 REGISTERS ....................236
TEST FEATURES DESCRIPTION.....................................................261
10.1
I/O TEST MODE......................................................................266
10.2
JTAG TEST PORT ...................................................................274
OPERATION ......................................................................................276
11.1
CONFIGURATION OPTIONS..................................................276
11.2
STS-1 MODE ..........................................................................277
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
ii
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
11.3
AU3 MODE..............................................................................278
11.4
AU4 MODE..............................................................................279
11.5
JTAG SUPPORT......................................................................281
11.5.1 TAP CONTROLLER......................................................282
11.5.2 BOUNDARY SCAN INSTRUCTIONS ...........................285
12
FUNCTIONAL TIMING.......................................................................293
13
APPLICATION EXAMPLES ...............................................................309
14
ABSOLUTE MAXIMUM RATINGS .....................................................310
15
D.C. CHARACTERISTICS..................................................................311
16
MICROPROCESSOR INTERFACE TIMING
CHARACTERISTICS .........................................................................314
17
TUPP-PLUS TIMING CHARACTERISTICS .......................................322
18
ORDERING AND THERMAL INFORMATION....................................330
19
MECHANICAL INFORMATION ..........................................................331
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
iii
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
LIST OF REGISTERS
REGISTER 00H: MASTER INCOMING CONFIGURATION ...........................67
REGISTER 01H: MASTER OUTGOING CONFIGURATION ..........................69
REGISTER 02H: INPUT SIGNAL ACTIVITY MONITOR,
ACCUMULATION TRIGGER ................................................................72
REGISTER 03H: MASTER RESET AND IDENTITY ......................................74
REGISTER 04H: VTPP #1 CONFIGURATION ...............................................75
REGISTER 05H: VTPP #2 CONFIGURATION ...............................................78
REGISTER 06H: VTPP #3 CONFIGURATION ...............................................81
REGISTER 07H: TRIBUTARY PAYLOAD PROCESSOR AND LOM
INTERRUPT ENABLE..........................................................................84
REGISTER 08H: TRIBUTARY PAYLOAD PROCESSOR
INTERRUPT AND LOM STATUS .........................................................86
REGISTER 09H: PARITY ERROR AND LOM INTERRUPT ...........................88
REGISTER 0AH: TRIBUTARY PATH OVERHEAD PROCESSOR
AND TRIBUTARY TRACE BUFFER INTERRUPT ENABLE.................90
REGISTER 0BH: TRIBUTARY PATH OVERHEAD PROCESSOR
AND TRIBUTARY TRACE BUFFER INTERRUPT STATUS..................92
REGISTER 0CH: RTOP #1 AND RTTB #1 CONFIGURATION.......................94
REGISTER 0DH: RTOP #2 AND RTTB #2 CONFIGURATION.......................96
REGISTER 0EH: RTOP #3 AND RTTB #3 CONFIGURATION.......................98
REGISTER 10H: TRIBUTARY ALARM AIS CONTROL ................................100
REGISTER 11H: TRIBUTARY REMOTE DEFECT INDICATION
CONTROL..........................................................................................102
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
iv
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
REGISTER 12H: TRIBUTARY AUXILIARY REMOTE DEFECT
INDICATION CONTROL ....................................................................104
REGISTER 13H: TRIBUTARY PDI CONTROL .............................................107
REGISTER 20H, 40H, 60H: VTPP, TU3 OR TU #1 IN TUG2 #1,
CONFIGURATION AND STATUS.......................................................109
REGISTER 21H-26H, 41H-46H, 61H-66H: VTPP, TU #1 IN TUG2
#2 TO TUG2 #7, CONFIGURATION AND STATUS ............................112
REGISTER 27H, 47H, 67H: VTPP, TU3 OR TU #1 IN TUG2 #1 TO
TUG2 #7, LOP INTERRUPT ..............................................................114
REGISTER 28H-2EH, 48H-4EH, 68H-6EH: VTPP, TU #2 IN TUG2
#1 TO TUG2 #7, CONFIGURATION AND STATUS ............................116
REGISTER 2FH, 4FH, 6FH: VTPP, TU #2 IN TUG2 #1 TO TUG2 #7,
LOP INTERRUPT...............................................................................119
REGISTER 30H-36H, 50H-56H, 70H-76H: VTPP, TU #3 IN TUG2
#1 TO TUG2 #7, CONFIGURATION AND STATUS ............................120
REGISTER 37H, 57H, 77H: VTPP, TU #3 IN TUG2 #1 TO TUG2 #7,
LOP INTERRUPT...............................................................................123
REGISTER 38H-3EH, 58H-5EH, 78H-7EH: VTPP, TU #4 IN TUG2
#1 TO TUG2 #7, CONFIGURATION AND STATUS ............................124
REGISTER 3FH, 5FH, 7FH: VTPP, TU #4 IN TUG2 #1 TO TUG2 #7,
LOP INTERRUPT...............................................................................127
REGISTER A0H, C0H, E0H: VTPP, TU3 OR TU #1 IN TUG2 #1,
ALARM STATUS.................................................................................128
REGISTER A1H-A6H, C1H-C6H, E1H-E6H: VTPP, TU #1 IN TUG2
#2 TO TUG2 #7, ALARM STATUS......................................................130
REGISTER A7H, C7H, E7H: VTPP, TU3 OR TU #1 IN TUG2 #1 TO
TUG2 #7, AIS INTERRUPT ...............................................................132
REGISTER A8H-AEH, C8H-CEH, E8H-EEH: VTPP, TU #2 IN TUG2
#1 TO TUG2 #7, ALARM STATUS......................................................134
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
v
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
REGISTER AFH, CFH, EFH: VTPP, TU #2 IN TUG2 #1 TO TUG2 #7
AIS INTERRUPT ................................................................................136
REGISTER B0H-B6H, D0H-D6H, F0H-F6H: VTPP, TU #3 IN TUG2
#1 TO TUG2 #7, ALARM STATUS......................................................137
REGISTER B7H, D7H, F7H: VTPP, TU #3 IN TUG2 #1 TO TUG2
#7, AIS INTERRUPT ..........................................................................139
REGISTER B8H-BEH, D8H-DEH, F8H-FEH: VTPP, TU #4 IN TUG2
#1 TO TUG2 #7, ALARM STATUS......................................................140
REGISTER BFH, DFH, FFH: VTPP, TU #4 IN TUG2 #1 TO TUG2
#7, AIS INTERRUPT ..........................................................................142
REGISTER 100H, 200H, 300H: RTOP, TU3 OR TU #1 IN TUG2 #1,
CONFIGURATION .............................................................................143
REGISTER 101H, 201H, 301H: RTOP, TU3 OR TU #1 IN TUG2 #1,
CONFIGURATION AND ALARM STATUS..........................................146
REGISTER 102H, 202H, 302H: RTOP, TU3 OR TU #1 IN TUG2 #1,
EXPECTED PATH SIGNAL LABEL....................................................149
REGISTER 103H, 203H, 303H: RTOP, TU3 OR TU #1 IN TUG2 #1,
ACCEPTED PATH SIGNAL LABEL....................................................150
REGISTER 104H, 204H, 304H: RTOP, TU3 OR TU #1 IN TUG2 #1,
BIP-2/BIP-8 ERROR COUNT LSB.....................................................151
REGISTER 105H, 205H, 305H: RTOP, TU3 OR TU #1 IN TUG2 #1,
BIP-2/BIP-8 ERROR COUNT MSB....................................................151
REGISTER 106H, 206H, 306H: RTOP, TU3 OR TU #1 IN TUG2 #1,
FEBE ERROR COUNT LSB ..............................................................153
REGISTER 107H, 207H, 307H: RTOP, TU3 OR TU #1 IN TUG2 #1,
FEBE ERROR COUNT MSB .............................................................153
REGISTER 108H, 110H, 118H, 120H, 128H, 130H: REGISTER
208H, 210H, 218H, 220H, 228H, 230H: REGISTER 308H,
310H, 318H, 320H, 328H, 330H: RTOP, TU #1 IN TUG2 #2
TO TUG2 #7, CONFIGURATION .......................................................155
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
vi
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
REGISTER 109H, 111H, 119H, 121H, 129H, 131H: REGISTER
209H, 211H, 219H, 221H, 229H, 231H: REGISTER 309H,
311H, 319H, 321H, 329H, 331H: RTOP, TU #1 IN TUG2 #2
TO TUG2 #7, CONFIGURATION AND ALARM STATUS ...................158
REGISTER 10AH, 112H, 11AH, 122H, 12AH, 132H: REGISTER
20AH, 212H, 21AH, 222H, 22AH, 232H: REGISTER 30AH,
312H, 31AH, 322H, 32AH, 332H: RTOP, TU #1 IN TUG2 #2
TO TUG2 #7, EXPECTED PATH SIGNAL LABEL..............................161
REGISTER 10BH, 113H, 11BH, 123H, 12BH, 133H: REGISTER
20BH, 213H, 21BH, 223H, 22BH, 233H: REGISTER 30BH,
313H, 31BH, 323H, 32BH, 333H: RTOP, TU #1 IN TUG2 #2
TO TUG2 #7, ACCEPTED PATH SIGNAL LABEL..............................162
REGISTER 10CH, 114H, 11CH, 124H, 12CH, 134H: REGISTER
20CH, 214H, 21CH, 224H, 22CH, 234H: REGISTER 30CH,
314H, 31CH, 324H, 32CH, 334H: RTOP, TU #1 IN TUG2 #2
TO TUG2 #7, BIP-2 ERROR COUNT LSB.........................................163
REGISTER 10DH, 115H, 11DH, 125H, 12DH, 135H: REGISTER
20DH, 215H, 21DH, 225H, 22DH, 235H: REGISTER 30DH,
315H, 31DH, 325H, 32DH, 335H: RTOP, TU #1 IN TUG2 #2
TO TUG2 #7, BIP-2 ERROR COUNT MSB........................................163
REGISTER 10EH, 116H, 11EH, 126H, 12EH, 136H: REGISTER
20EH, 216H, 21EH, 226H, 22EH, 236H: REGISTER 30EH,
316H, 31EH, 326H, 32EH, 336H: TU #1 IN TUG2 #2 TO
TUG2 #7, FEBE ERROR COUNT LSB..............................................165
REGISTER 10FH, 117H, 11FH, 127H, 12FH, 137H: REGISTER
20FH, 217H, 21FH, 227H, 22FH, 237H: REGISTER 30FH,
317H, 31FH, 327H, 32FH, 337H: TU #1 IN TUG2 #2 TO
TUG2 #7, FEBE ERROR COUNT MSB.............................................165
REGISTER 138H, 238H, 338H: RTOP, TU3 OR TU #1 IN TUG2 #1
TO TUG2 #7, COPSL INTERRUPT ...................................................167
REGISTER 139H, 239H, 339H: RTOP, TU3 OR TU #1 IN TUG2 #1
TO TUG2 #7, PSLM INTERRUPT......................................................169
REGISTER 13AH, 23AH, 33AH: RTOP, TU3 OR TU #1 IN TUG2 #1
TO TUG2 #7, PSLU INTERRUPT ......................................................171
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
vii
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
REGISTER 13BH, 23BH, 33BH: RTOP, TU3 OR TU #1 IN TUG2 #1
TO TUG2 #7, RDI INTERRUPT .........................................................173
REGISTER 13CH, 23CH, 33CH: RTOP, TU3 AUXILIARY RDI
INTERRUPT OR TU #1 IN TUG2 #1 TO TUG2 #7 RFI
INTERRUPT.......................................................................................175
REGISTER 13DH, 23DH, 33DH: RTOP, TU3 OR TU #1 IN TUG2 #1
TO TUG2 #7, IN BAND ERROR REPORTING
CONFIGURATION .............................................................................177
REGISTER 13EH, 23EH, 33EH: RTOP, TU3 OR TU #1 IN TUG2 #1
TO TUG2 #7, CONTROLLABLE OUTPUT
CONFIGURATION .............................................................................178
REGISTER 140H, 148H, 150H, 158H, 160H, 168H, 170H:
REGISTER 240H, 248H, 250H, 258H, 260H, 268H, 270H:
REGISTER 340H, 348H, 350H, 358H, 360H, 368H, 370H:
RTOP, TU #2 IN TUG2 #1 TO TUG2 #7, CONFIGURATION ..............179
REGISTER 141H, 149H, 151H, 159H, 161H, 169H, 171H:
REGISTER 241H, 249H, 251H, 259H, 261H, 269H, 271H:
REGISTER 341H, 349H, 351H, 359H, 361H, 369H, 371H:
RTOP, TU #2 IN TUG2 #1 TO TUG2 #7, CONFIGURATION
AND ALARM STATUS ........................................................................182
REGISTER 142H, 14AH, 152H, 15AH, 162H, 16AH, 172H:
REGISTER 242H, 24AH, 252H, 25AH, 262H, 26AH, 272H:
REGISTER 342H, 34AH, 352H, 35AH, 362H, 36AH, 372H:
RTOP, TU #2 IN TUG2 #1 TO TUG2 #7, EXPECTED PATH
SIGNAL LABEL..................................................................................185
REGISTER 143H, 14BH, 153H, 15BH, 163H, 16BH, 173H:
REGISTER 243H, 24BH, 253H, 25BH, 263H, 26BH, 273H:
REGISTER 343H, 34BH, 353H, 35BH, 363H, 36BH, 373H:
RTOP, TU #2 IN TUG2 #1 TO TUG2 #7, ACCEPTED PATH
SIGNAL LABEL..................................................................................186
REGISTER 144H, 14CH, 154H, 15CH, 164H, 16CH, 174H:
REGISTER 244H, 24CH, 254H, 25CH, 264H, 26CH, 274H:
REGISTER 344H, 34CH, 354H, 35CH, 364H, 36CH, 374H:
RTOP, TU #2 IN TUG2 #1 TO TUG2 #7, BIP-2 ERROR
COUNT LSB ......................................................................................187
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
viii
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
REGISTER 145H, 14DH, 155H, 15DH, 165H, 16DH, 175H:
REGISTER 245H, 24DH, 255H, 25DH, 265H, 26DH, 275H:
REGISTER 345H, 34DH, 355H, 35DH, 365H, 36DH, 375H:
RTOP, TU #2 IN TUG2 #1 TO TUG2 #7, BIP-2 ERROR
COUNT MSB......................................................................................187
REGISTER 146H, 14EH, 156H, 15EH, 166H, 16EH, 176H:
REGISTER 246H, 24EH, 256H, 25EH, 266H, 26EH, 276H:
REGISTER 346H, 34EH, 356H, 35EH, 366H, 36EH, 376H:
RTOP, TU #2 IN TUG2 #1 TO TUG2 #7, FEBE ERROR
COUNT LSB ......................................................................................189
REGISTER 147H, 14FH, 157H, 15FH, 167H, 16FH, 177H:
REGISTER 247H, 24FH, 257H, 25FH, 267H, 26FH, 277H:
REGISTER 347H, 34FH, 357H, 35FH, 367H, 36FH, 377H:
RTOP, TU #2 IN TUG2 #1 TO TUG2 #7, FEBE ERROR
COUNT MSB......................................................................................189
REGISTER 178H, 278H, 378H: RTOP, TU #2 IN TUG2 #1 TO TUG2
#7, COPSL INTERRUPT....................................................................191
REGISTER 179H, 279H, 379H: RTOP, TU #2 IN TUG2 #1 TO TUG2
#7, PSLM INTERRUPT ......................................................................192
REGISTER 17AH, 27AH, 37AH: RTOP, TU #2 IN TUG2 #1 TO
TUG2 #7, PSLU INTERRUPT............................................................193
REGISTER 17BH, 27BH, 37BH: RTOP, TU #2 IN TUG2 #1 TO
TUG2 #7, RDI INTERRUPT ...............................................................194
REGISTER 17CH, 27CH, 37CH: RTOP, TU #2 IN TUG2 #1 TO
TUG2 #7, RFI INTERRUPT ...............................................................195
REGISTER 17DH, 27DH, 37DH: RTOP, TU #2 IN TUG2 #1 TO
TUG2 #7, IN BAND ERROR REPORTING
CONFIGURATION .............................................................................196
REGISTER 17EH, 27EH, 37EH: TU #2 IN TUG2 #1 TO TUG2 #7,
CONTROLLABLE OUTPUT CONFIGURATION ................................197
REGISTER 180H, 188H, 190H, 198H, 1A0H, 1A8H, 1B0H:
REGISTER 280H, 288H, 290H, 298H, 2A0H, 2A8H, 2B0H:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
ix
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
REGISTER 380H, 388H, 390H, 398H, 3A0H, 3A8H, 3B0H:
RTOP, TU #3 IN TUG2 #1 TO TUG2 #7, CONFIGURATION ..............198
REGISTER 181H, 189H, 191H, 199H, 1A1H, 1A9H, 1B1H:
REGISTER 281H, 289H, 291H, 299H, 2A1H, 2A9H, 2B1H:
REGISTER 381H, 389H, 391H, 399H, 3A1H, 3A9H, 3B1H:
RTOP, TU #3 IN TUG2 #1 TO TUG2 #7, CONFIGURATION
AND ALARM STATUS ........................................................................201
REGISTER 182H, 18AH, 192H, 19AH, 1A2H, 1AAH, 1B2H:
REGISTER 282H, 28AH, 292H, 29AH, 2A2H, 2AAH, 2B2H:
REGISTER 382H, 38AH, 392H, 39AH, 3A2H, 3AAH, 3B2H:
RTOP, TU #3 IN TUG2 #1 TO TUG2 #7, EXPECTED PATH
SIGNAL LABEL..................................................................................204
REGISTER 183H, 18BH, 193H, 19BH, 1A3H, 1ABH, 1B3H:
REGISTER 283H, 28BH, 293H, 29BH, 2A3H, 2ABH, 2B3H:
REGISTER 383H, 38BH, 393H, 39BH, 3A3H, 3ABH, 3B3H:
RTOP, TU #3 IN TUG2 #1 TO TUG2 #7, ACCEPTED PATH
SIGNAL LABEL..................................................................................205
REGISTER 184H, 18CH, 194H, 19CH, 1A4H, 1ACH, 1B4H:
REGISTER 284H, 28CH, 294H, 29CH, 2A4H, 2ACH, 2B4H:
REGISTER 384H, 38CH, 394H, 39CH, 3A4H, 3ACH, 3B4H:
RTOP, TU #3 IN TUG2 #1 TO TUG2 #7, BIP-2 ERROR
COUNT LSB ......................................................................................206
REGISTER 185H, 18DH, 195H, 19DH, 1A5H, 1ADH, 1B5H:
REGISTER 285H, 28DH, 295H, 29DH, 2A5H, 2ADH, 2B5H:
REGISTER 385H, 38DH, 395H, 39DH, 3A5H, 3ADH, 3B5H:
RTOP, TU #3 IN TUG2 #1 TO TUG2 #7, BIP-2 ERROR
COUNT MSB......................................................................................206
REGISTER 186H, 18EH, 196H, 19EH, 1A6H, 1AEH, 1B6H:
REGISTER 286H, 28EH, 296H, 29EH, 2A6H, 2AEH, 2B6H:
REGISTER 386H, 38EH, 396H, 39EH, 3A6H, 3AEH, 3B6H:
TU #3 IN TUG2 #1 TO TUG2 #7, FEBE ERROR COUNT
LSB ....................................................................................................208
REGISTER 187H, 18FH, 197H, 19FH, 1A7H, 1AFH, 1B7H:
REGISTER 287H, 28FH, 297H, 29FH, 2A7H, 2AFH, 2B7H:
REGISTER 387H, 38FH, 397H, 39FH, 3A7H, 3AFH, 3B7H:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
x
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
RTOP, TU #3 IN TUG2 #1 TO TUG2 #7, FEBE ERROR
COUNT MSB......................................................................................208
REGISTER 1B8H, 2B8H, 3B8H: RTOP, TU #3 IN TUG2 #1 TO
TUG2 #7, COPSL INTERRUPT .........................................................210
REGISTER 1B9H, 2B9H, 3B9H: RTOP, TU #3 IN TUG2 #1 TO
TUG2 #7, PSLM INTERRUPT ...........................................................211
REGISTER 1BAH, 2BAH, 3BAH: RTOP, TU #3 IN TUG2 #1 TO
TUG2 #7, PSLU INTERRUPT............................................................212
REGISTER 1BBH, 2BBH, 3BBH: RTOP, TU #3 IN TUG2 #1 TO
TUG2 #7, RDI INTERRUPT ...............................................................213
REGISTER 1BCH, 2BCH, 3BCH: RTOP, TU #3 IN TUG2 #1 TO
TUG2 #7, RFI INTERRUPT ...............................................................214
REGISTER 1BDH, 2BDH, 3BDH: RTOP, TU #3 IN TUG2 #1 TO
TUG2 #7, IN BAND ERROR REPORTING
CONFIGURATION .............................................................................215
REGISTER 1BEH, 2BEH, 3BEH: RTOP, TU #3 IN TUG2 #1 TO
TUG2 #7, CONTROLLABLE OUTPUT CONFIGURATION................216
REGISTER 1C0H, 1C8H, 1D0H, 1D8H, 1E0H, 1E8H, 1F0H:
REGISTER 2C0H, 2C8H, 2D0H, 2D8H, 2E0H, 2E8H, 2F0H:
REGISTER 3C0H, 3C8H, 3D0H, 3D8H, 3E0H, 3E8H, 3F0H:
RTOP, TU #4 IN TUG2 #1 TO TUG2 #7, CONFIGURATION ..............217
REGISTER 1C1H, 1C9H, 1D1H, 1D9H, 1E1H, 1E9H, 1F1H:
REGISTER 2C1H, 2C9H, 2D1H, 2D9H, 2E1H, 2E9H, 2F1H:
REGISTER 3C1H, 3C9H, 3D1H, 3D9H, 3E1H, 3E9H, 3F1H:
RTOP, TU #4 IN TUG2 #1 TO TUG2 #7, CONFIGURATION
AND ALARM STATUS ........................................................................219
REGISTER 1C2H, 1CAH, 1D2H, 1DAH, 1E2H, 1EAH, 1F2H:
REGISTER 2C2H, 2CAH, 2D2H, 2DAH, 2E2H, 2EAH, 2F2H:
REGISTER 3C2H, 3CAH, 3D2H, 3DAH, 3E2H, 3EAH, 3F2H:
RTOP, TU #4 IN TUG2 #1 TO TUG2 #7, EXPECTED PATH
SIGNAL LABEL..................................................................................222
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
xi
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
REGISTER 1C3H, 1CBH, 1D3H, 1DBH, 1E3H, 1EBH, 1F3H:
REGISTER 2C3H, 2CBH, 2D3H, 2DBH, 2E3H, 2EBH, 2F3H:
REGISTER 3C3H, 3CBH, 3D3H, 3DBH, 3E3H, 3EBH, 3F3H:
RTOP, TU #4 IN TUG2 #1 TO TUG2 #7, PATH SIGNAL
LABEL................................................................................................223
REGISTER 1C4H, 1CCH, 1D4H, 1DCH, 1E4H, 1ECH, 1F4H:
REGISTER 2C4H, 2CCH, 2D4H, 2DCH, 2E4H, 2ECH,
2F4H: REGISTER 3C4H, 3CCH, 3D4H, 3DCH, 3E4H,
3ECH, 3F4H: RTOP, TU #4 IN TUG2 #1 TO TUG2 #7, BIP-2
ERROR COUNT LSB.........................................................................224
REGISTER 1C5H, 1CDH, 1D5H, 1DDH, 1E5H, 1EDH, 1F5H:
REGISTER 2C5H, 2CDH, 2D5H, 2DDH, 2E5H, 2EDH,
2F5H: REGISTER 3C5H, 3CDH, 3D5H, 3DDH, 3E5H,
3EDH, 3F5H: RTOP, TU #4 IN TUG2 #1 TO TUG2 #7, BIP-2
ERROR COUNT MSB........................................................................224
REGISTER 1C6H, 1CEH, 1D6H, 1DEH, 1E6H, 1EEH, 1F6H:
REGISTER 2C6H, 2CEH, 2D6H, 2DEH, 2E6H, 2EEH, 2F6H:
REGISTER 3C6H, 3CEH, 3D6H, 3DEH, 3E6H, 3EEH, 3F6H:
RTOP, TU #4 IN TUG2 #1 TO TUG2 #7, FEBE ERROR
COUNT LSB ......................................................................................226
REGISTER 1C7H, 1CFH, 1D7H, 1DFH, 1E7H, 1EFH, 1F7H:
REGISTER 2C7H, 2CFH, 2D7H, 2DFH, 2E7H, 2EFH, 2F7H:
REGISTER 3C7H, 3CFH, 3D7H, 3DFH, 3E7H, 3EFH, 3F7H:
RTOP, TU #4 IN TUG2 #1 TO TUG2 #7, FEBE ERROR
COUNT MSB......................................................................................226
REGISTER 1F8H, 2F8H, 3F8H: RTOP, TU #4 IN TUG2 #1 TO
TUG2 #7, COPSL INTERRUPT .........................................................228
REGISTER 1F9H, 2F9H, 3F9H: RTOP, TU #4 IN TUG2 #1 TO
TUG2 #7, PSLM INTERRUPT ...........................................................229
REGISTER 1FAH, 2FAH, 3FAH: RTOP, TU #4 IN TUG2 #1 TO
TUG2 #7, PSLU INTERRUPT............................................................230
REGISTER 1FBH, 2FBH, 3FBH: RTOP, TU #4 IN TUG2 #1 TO
TUG2 #7, RDI INTERRUPT ...............................................................231
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
xii
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
REGISTER 1FCH, 2FCH, 3FCH: RTOP, TU #4 IN TUG2 #1 TO
TUG2 #7, RFI INTERRUPT ...............................................................232
REGISTER 1FDH, 2FDH, 3FDH: RTOP, TU #4 IN TUG2 #1 TO
TUG2 #7, IN BAND ERROR REPORTING
CONFIGURATION .............................................................................233
REGISTER 1FEH, 2FEH, 3FEH: RTOP, TU #4 IN TUG2 #1 TO
TUG2 #7, CONTROLLABLE OUTPUT CONFIGURATION................234
REGISTER 1FFH, 2FFH, 3FFH: RTOP STATUS ..........................................235
REGISTER 400H, 440H, 480H: RTTB, TU3 OR TU #1 IN TUG2 #1,
CONFIGURATION AND STATUS.......................................................236
REGISTER 401H-406H, 441H-446H, 481H-486H: RTTB, TU #1 IN
TUG2 #2 TO TUG2 #7, CONFIGURATION AND STATUS .................238
REGISTER 408H-40EH, 448H-44EH, 488H-48EH: RTTB, TU #2 IN
TUG2 #1 TO TUG2 #7, CONFIGURATION AND STATUS .................240
REGISTER 410H-416H, 450H-456H, 490H-496H: RTTB, TU #3 IN
TUG2 #1 TO TUG2 #7, CONFIGURATION AND STATUS .................242
REGISTER 418H-41EH, 458H-45EH, 498H-49EH: RTTB, TU #4
IN TUG2 #1 TO TUG2 #7, CONFIGURATION AND STATUS .............244
REGISTER 420H, 460H, 4A0H: RTTB, TU3 OR TU #1 IN TUG2 #1
TO TUG2 #7, TIM INTERRUPT..........................................................246
REGISTER 421H, 461H, 4A1H: RTTB, TU #2 IN TUG2 #1 TO
TUG2 #7, TIM INTERRUPT ...............................................................248
REGISTER 422H, 462H, 4A2H: RTTB, TU #3 IN TUG2 #1 TO
TUG2 #7, TIM INTERRUPT ...............................................................249
REGISTER 423H, 463H, 4A3H: RTTB, TU #4 IN TUG2 #1 TO
TUG2 #7, TIM INTERRUPT ...............................................................250
REGISTER 424H, 464H, 4A4H: RTTB, TU3 OR TU #1 IN TUG2 #1
TO TUG2 #7, TIU INTERRUPT ..........................................................251
REGISTER 425H, 465H, 4A5H: RTTB, TU #2 IN TUG2 #1 TO
TUG2 #7, TIU INTERRUPT................................................................253
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
xiii
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
REGISTER 426H, 466H, 4A6H: RTTB, TU #3 IN TUG2 #1 TO
TUG2 #7, TIU INTERRUPT................................................................254
REGISTER 427H, 467H, 4A7H: RTTB, TU #4 IN TUG2 #1 TO
TUG2 #7, TIU INTERRUPT................................................................255
REGISTER 428H, 468H, 4A8H: RTTB, TIU THRESHOLD ...........................256
REGISTER 429H, 469H, 4A9H: RTTB, INDIRECT TRIBUTARY
SELECT .............................................................................................257
REGISTER 42AH, 46AH, 4AAH: RTTB, INDIRECT ADDRESS
SELECT .............................................................................................258
REGISTER 42BH, 46BH, 4ABH: RTTB, INDIRECT DATA SELECT .............260
REGISTER 800H: MASTER TEST ...............................................................265
TEST REGISTER 801H: (WRITE IN I/O TEST MODE) ................................267
TEST REGISTER 802H: (WRITE IN I/O TEST MODE) ................................268
TEST REGISTER 803H: (WRITE IN I/O TEST MODE) ................................269
TEST REGISTER 804H: (WRITE IN I/O TEST MODE) ................................270
TEST REGISTER 805H: (WRITE IN I/O TEST MODE) ................................271
TEST REGISTER 801H: (READ IN I/O TEST MODE)..................................272
TEST REGISTER 802H: (READ IN I/O TEST MODE)..................................273
TEST REGISTER 803H: (READ IN I/O TEST MODE)..................................274
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
xiv
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
LIST OF FIGURES
FIGURE 1 - POINTER INTERPRETATION STATE DIAGRAM.......................44
FIGURE 2 - POINTER GENERATION STATE DIAGRAM..............................49
FIGURE 3 - SONET STS-3 CARRYING VT1.5 WITHIN STS-1...................278
FIGURE 4 - SDH STM-1 CARRYING TU12 WITHIN VC3/AU3 ...................278
FIGURE 5 - SDH STM-1 CARRYING TU12 WITHIN TUG3/AU4.................279
FIGURE 6 - SDH STM-1 CARRYING TU3 WITHIN TUG3 ..........................280
FIGURE 7 - SDH STM-1 CARRYING MIX OF TU11, TU12, TU3
WITHIN TUG3/AU4 .......................................................................................280
FIGURE 8 - BOUNDARY SCAN ARCHITECTURE .....................................281
FIGURE 9 - TAP CONTROLLER FINITE STATE MACHINE........................283
FIGURE 10- INPUT OBSERVATION CELL (INPUT, CLOCK INPUT)...........290
FIGURE 11- OUTPUT CELL (OUTPUT, CLOCK OUTPUT,
OUTPUT ENABLE).......................................................................................291
FIGURE 12- BIDIRECTIONAL CELL (IO_CELL) .........................................292
FIGURE 13- I/O CELL (I/O WITH OE PAIR).................................................292
FIGURE 14- INPUT BUS TIMING - SIMPLE STS-1/AU3 CASE ..................293
FIGURE 15- INPUT BUS TIMING - COMPLEX STS-1 / AU3 CASE ............294
FIGURE 16- INPUT BUS TIMING - AU4 CASE............................................295
FIGURE 17- OUTPUT BUS TIMING - LOCKED STS-1 SPES / AU3
VCS CASE 296
FIGURE 18- OUTPUT BUS TIMING - FLOATING STS-1 SPES /
AU3 VCS CASE ............................................................................................297
FIGURE 19- OUTPUT BUS TIMING - LOCKED AU4 VC CASE ..................299
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
xv
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
FIGURE 20- OUTPUT BUS TIMING - FLOATING AU4 VC CASE................300
FIGURE 21- BYTE INTERFACE, BY-PASSED MODE
FUNCTIONAL TIMING..................................................................................301
FIGURE 22- NIBBLE INTERFACE, BY-PASSED MODE
FUNCTIONAL TIMING..................................................................................302
FIGURE 23- TRIBUTARY PATH OVERHEAD SERIALIZATION
FUNCTIONAL TIMING..................................................................................304
FIGURE 24- RECEIVE ALARM PORT FUNCTIONAL TIMING....................306
FIGURE 25- NIBBLE INTERFACE MODE INPUT/OUTPUT
FUNCTIONAL TIMING..................................................................................308
FIGURE 26- SONET/SDH TRIBUTARY CROSS-CONNECT
APPLICATION ..............................................................................................309
FIGURE 27- MICROPROCESSOR INTERFACE READ TIMING
(INTEL MODE) .............................................................................................315
FIGURE 28- MICROPROCESSOR INTERFACE READ TIMING
(MOTOROLA MODE)....................................................................................316
FIGURE 29- MICROPROCESSOR INTERFACE WRITE TIMING
(INTEL MODE) .............................................................................................319
FIGURE 30- MICROPROCESSOR INTERFACE WRITE TIMING
(MOTOROLA MODE)....................................................................................320
FIGURE 31- INPUT TIMING.........................................................................323
FIGURE 32- STREAM OUTPUT TIMING .....................................................326
FIGURE 33- PATH OVERHEAD OUTPUT TIMING ......................................327
FIGURE 34- JTAG PORT INTERFACE TIMING ...........................................329
FIGURE 35- METRIC PLASTIC QUAD FLATPACK - MQFP (BODY
28X28X3.49MM) 160 PIN MQFP - (R SUFFIX)............................................331
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
xvi
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
LIST OF TABLES
TABLE 1
- PATH SIGNAL LABEL MISMATCH STATE.................................53
TABLE 2
- TEST MODE REGISTER MEMORY MAP ...............................261
TABLE 3
- INSTRUCTION REGISTER .....................................................274
TABLE 4
- BOUNDARY SCAN PIN ORDER .............................................286
TABLE 5
- TUPP-PLUS ABSOLUTE MAXIMUM RATINGS ......................310
TABLE 6
- TUPP-PLUS D.C. CHARACTERISTICS...................................311
TABLE 7 - MICROPROCESSOR INTERFACE READ ACCESS
(FIGURE 27, FIGURE 28) ............................................................................314
TABLE 8 - MICROPROCESSOR INTERFACE WRITE ACCESS
(FIGURE 29, FIGURE 30) ............................................................................318
TABLE 9
- TUPP-PLUS INPUT (FIGURE 31) ...........................................322
TABLE 10 - TUPP-PLUS STREAM OUTPUT (FIGURE 32) .......................325
TABLE 11 - TUPP-PLUS PATH OVERHEAD OUTPUT (FIGURE
33)
327
TABLE 12 - JTAG PORT INTERFACE (FIGURE 34)...................................328
TABLE 13 - TUPP-PLUS ORDERING INFORMATION ...............................330
TABLE 14 - TUPP-PLUS THERMAL INFORMATION..................................330
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
xvii
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
xviii
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
1
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
FEATURES
•
Configurable, multi-channel, payload processor for aligning SONET virtual
tributaries (VTs) or SDH tributary units (TUs) in an STS-3 or STM-1 byte
serial data stream.
•
Transfers all incoming tributaries in the three STS-1 synchronous payload
envelopes of an STS-3 byte serial stream to the three STS-1 synchronous
payload envelopes of an outgoing STS-3 byte serial stream.
•
Transfers all incoming tributaries in the single AU4 or three AU3 administrative
units of an STM-1 byte serial stream to the single AU4 or three AU3
administrative units of an outgoing STM-1 byte serial stream.
•
Compensates for pleisiochronous relationships between incoming and
outgoing higher level (STS-1, AU4, AU3) payload frame rates through
processing of the lower level (VT6, VT3, VT2, VT1.5, TU3, TU2, TU12, or
TU11) tributary pointers.
•
Configurable to process any legal mix of tributaries such as VT1.5, VT2, VT3,
VT6, TU11, TU12, TU2, or TU3. Each VT group or TUG2 can be configured
to carry one of four tributary types. TUG2s can be multiplexed into VC3s or
TUG3s. Each TUG3 can also be configured to carry a single TU3.
•
Independently configurable for AU3 or AU4 frame format on incoming and
outgoing interfaces.
•
Configurable to process 16-byte or 64-byte format tributary path trace
messages (tributary trail trace identifiers).
•
Optionally frames to the H4 byte in the path overhead to determine tributary
multiframe boundaries. Inserts internally generated H4 bytes with leading
logic 1 bits into the outgoing administrative units.
•
Extracts and serializes the entire tributary path overhead for each tributary
into lower speed serial streams.
•
Extracts tributary size (SS) bits for each tributary into internal registers.
•
Detects loss of pointer (LOP) and re-acquisition for each tributary and
optionally generates interrupts.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
1
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
•
Detects tributary path alarm indication signal (AIS) and return to normal state
for each tributary and optionally generates interrupts.
•
Detects tributary elastic store underflow and overflow errors and optionally
generates interrupts.
•
Extracts tributary path trace message (trail trace identifier) for each tributary
into internal buffers.
•
Provides individual tributary path trace message buffer that holds the
expected message and detects tributary path trace mismatch (trail trace
identifier mismatch) alarms (TIM) and return to matched state for each
tributary and optionally generates interrupts.
•
Detects tributary path trace unstable (trail trace identifier unstable) alarms
(TIU) and return to stable state for each tributary and optionally generates
interrupts.
•
Extracts tributary path signal label for each tributary into internal registers and
detects change of tributary path signal label events (COPSL) for each
tributary and optionally generates interrupts.
•
Provides individual tributary path signal label register that hold the expected
label and detects tributary path signal label mismatch alarms (PSLM) and
return to matched state for each tributary and optionally generates interrupts.
•
Detects tributary path signal label unstable alarms (PSLU) and return to
stable state for each tributary and optionally generates interrupts.
•
Detects tributary unequipped defect (UNEQ) and tributary path defect
indication (PDI-V).
•
Detects assertion and removal of tributary extended remote defect indications
(RDI) for each tributary and optionally generates interrupts.
•
Calculates and compares the tributary path BIP-2 error detection code for
each tributary and configurable to accumulate the BIP-2 errors, on block or bit
basis, in internal registers.
•
Calculates and compares the TU3 path BIP-8 error detection code for each
TU3 stream and accumulates the BIP-8 errors, on block or bit basis, in
internal registers.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
2
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
•
Accumulates TU3 tributary far end block errors (FEBE) on a bit or a block
basis, in internal registers.
•
Allows insertion of all-zeros or all-ones tributary idle code with unequipped
indication and valid pointer into any tributary under software control. Idle
tributaries are identified by an output signal.
•
Identifies outgoing tributaries that are in AIS state by an output signal. Allows
software to force the AIS insertion on a per tributary basis.
•
Inserts valid H4 byte and all-zeros fixed stuff bytes on the outgoing stream.
Remaining path overhead bytes (J1, B3, C2, G1, F2, Z3, Z4, and Z5) can be
configured to be set to all-zeros or to reflect the value of the corresponding
POH bytes in the incoming stream.
•
Inserts valid pointers, and all-zeros transport overhead bytes on the outgoing
stream with valid "TeleCombus" control signals when configured to operate in
locked mode.
•
Supports in-band error reporting by updating the FEBE, RDI and auxiliary
RDI bits in the V5 byte (G1 in TU3) with the status of the incoming stream.
•
Provides low maximum tributary processing delay of 33 µs for VT1.5, 25 µs
for VT2, 17 µs for VT3, and 9 µs for VT6 streams.
•
Verifies parity on the IC1J1 and ISPE signals and on the incoming data
stream and generates parity on the outgoing data stream.
•
May be used for multiframe synchronization or ring closure at the head-end
node of a SONET/SDH ring.
•
Operates in conjunction with the PM5344 SPTX SONET/SDH Path
Terminating Transceiver to align tributaries such that they can be switched by
the PM5371 TUDX SONET/SDH Tributary Unit Cross-Connect. Provides
backwards compatibility with the PM5361 TUPP SONET/SDH Tributary Unit
Payload Processor.
•
Independently configurable incoming and outgoing interfaces that operate in
byte interface mode from a single 19.44 MHz clock or in nibble interface
mode from a single 38.88 MHz clock.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
3
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
•
Provides a generic 8-bit microprocessor bus interface for configuration,
control, and status monitoring.
•
Provides a standard 5 signal IEEE P1149.1 JTAG test port for boundary scan
test purposes.
•
Low power, +5 Volt, CMOS technology, TTL compatible inputs and outputs.
•
160 pin plastic quad flat pack (PQFP) package
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
4
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
2
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
APPLICATIONS
•
SONET/SDH Wideband Cross-Connect
•
SONET/SDH Add-Drop Multiplexer
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
5
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
3
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
REFERENCES
1. American National Standard for Telecommunications - Digital Hierarchy Optical Interface Rates and Formats Specification, ANSI T1.105-1991.
2. American National Standard for Telecommunications - Digital Hierarchy Optical Interface Rates and Formats Specification - Supplement, ANSI
T1.105a-1991.
3. Committee T1 Contribution, "Draft of T1.105 - SONET Rates and Formats",
T1X1.5/94-033R2-1994.
4. Committee T1 Contribution, "Payload Defect Indication (PDI): triggers, Switch
Priorities, Timing and Proposed Text", T1X1.5/94-135R1, 1994.
5. Committee T1 Contribution, "Proposed ITU-T Contribution on Enhanced Path
RDI for SDH", T1X1.5/94-117, 1994.
6. ITU, Recommendation G.708 - "Network Node Interface For The
Synchronous Digital Hierarchy", 1993.
7. ITU, Recommendation G.709 - "Synchronous Multiplexing Structure", 1993.
8. ITU, Recommendation G.782 - "Types and general characteristics of
synchronous digital hierarchy (SDH) equipment", 1990.
9. ITU, Recommendation G.783 - "Characteristics of synchronous digital
hierarchy (SDH) equipment functional blocks", 1990.
10. Bell Communications Research - SONET Transport Systems: Common
Generic Criteria, TR-TSY-000253, Issue 2, December 1991.
11. Bell Communications Research - SONET Transport Systems: Common
Generic Criteria, GR-253-CORE, Issue 1, December 1994.
12. Bell Communications Research - SONET Add-Drop Multiplex Equipment
(SONET ADM) Generic Criteria, TR-NWT-000496, Issue 3, May 1992.
13. Bell Communications Research - SONET Dual-Fed Unidirectional Path
Switched Ring (UPSR) Equipment Generic Criteria, GR-1400-CORE, Issue 1,
March 1994.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
6
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
14. European Telecommunications Standards Institute, Transmission and
Multiplexing (TM); Generic Functional Requirements for SDH Transmission
Equipment, Part 1, Generic Process and Performance, prETS 300 417-1-1,
June 1995.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
7
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
4
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
DESCRIPTION
The PM5362 TUPP-PLUS SONET/SDH Tributary Unit Payload Processor /
Performance Monitor is a monolithic integrated circuit that implements a
configurable, multi-channel, payload processor that aligns and monitors
performance of SONET virtual tributaries (VTs) or SDH tributary units (TUs.).
When configured for SONET compatible operation, the TUPP-PLUS transfers all
tributaries in the three STS-1 synchronous payload envelopes of an incoming
STS-3 byte serial stream to the three STS-1 synchronous payload envelopes of
an outgoing STS-3 byte serial stream. Similarly, when configured for SDH
compatible operation, the TUPP-PLUS transfers all tributaries in the single AU4
or three AU3 administrative units of an incoming STM-1 byte serial stream to a
single AU4 or three AU3 administrative units of an outgoing STM-1 byte serial
stream. The TUPP-PLUS compensates for pleisiochronous relationships
between incoming and outgoing higher level (STS-1, AU4, AU3) synchronous
payload envelope frame rates through processing of the lower level (VT6, VT3,
VT2, VT1.5, TU3, TU2, TU12, TU11) tributary pointers.
The TUPP-PLUS is configurable to process any legal mix of tributaries. Each VT
group can be configured to carry any one of the four tributary types (VT1.5, VT2,
VT3, or VT6) and each TUG2 can be configured to carry any one of three
tributary types (TU11, TU12, or TU2). TUG2s can be multiplexed into a VC3 or a
TUG3. Alternatively, each TUG3 can be configured to carry a TU3.
The TUPP-PLUS operates in conjunction with the PM5344 SONET/SDH Path
Terminating Transceiver to align tributaries such that they can be switched by the
PM5371 TUDX SONET/SDH Tributary Unit Cross-Connect.
The TUPP-PLUS provides useful maintenance functions. They include, for each
tributary, detection of loss of pointer, detection of AIS alarm, detection of tributary
path signal label mismatch and unstable alarms, detection of tributary path trace
mismatch and unstable alarms. Optionally, interrupts can be generated due to
the assertion and removal of any of the above alarm conditions. The
TUPP-PLUS counts received tributary path BIP-2 (BIP-8 for TU3) errors on a
block or bit basis and counts FEBE indications. The TUPP-PLUS also allows
insertion of tributary path AIS as a consequence of any of the above alarm
conditions. In addition, the TUPP-PLUS may insert tributary idle (unequipped)
into any tributary. Incoming tributary path trace messages and path signal labels
are stored in a set of microprocessor accessible registers. The TUPP-PLUS can
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
8
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
also insert inverted new data flag fields that can be used to diagnose
downstream pointer processing elements.
No auxiliary high speed clocks are required as the TUPP-PLUS operates from
either a single 19.44 MHz or a single 38.88 MHz line rate clock. The
TUPP-PLUS is configured, controlled and monitored via a generic 8-bit
microprocessor bus interface.
The TUPP-PLUS is implemented in low power, +5 Volt, CMOS technology. It has
TTL compatible inputs and outputs and is packaged in a 160 pin HPPQFP
package.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
9
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
PIN DIAGRAM
PIN 160
VSST
VSST
VSST
A[9]
A[10]
VDDI
VDDODC
SCLK
VSSODC
VSSI
VSSOAC
GSCLK[0]
VDDOAC
NSCLK
OBMODE
IBMODE
LOM[1]
VDDI
VSSI
LC1J1V1
LPL
POHEN[1]
VSSODC
VDDODC
OTV5
POH[1]
OTPL
POHFP[1]
OPL
VDDI
VDDOAC
VSSOAC
VSSI
OC1J1
POHCK
OTMF
RAD
VSST
VSST
VSST
The TUPP-PLUS is packaged in an 160 pin PQFP package having a body size of
28 mm by 28 mm and a pin pitch of 0.65 mm. Pins added since the PM5361TUPP are underlined.
PIN 121
PIN 1
PIN 120
VSST
VSST
VSST
A[0]
A[1]
A[2]
A[3]
A[4]
A[5]
A[6]
A[7]
A[8]
CSB
MBEB
D[0]
D[1]
D[2]
D[3]
VDDODC
VDDI
VSSI
VSSODC
D[4]
D[5]
D[6]
D[7]
VDDOAC
INTB
VSSOAC
VSSODC
RSTB
VDDODC
ALE
A[11]/TRS
RDB_E
NC
WRB_RWB
VSST
VSST
VSST
VSST
VSST
VSST
VDDODC
VSSODC
IDLE
AIS
VDDOAC
VSSOAC
POHEN[2]
OD[0]
POH[2]
OD[1]
POHFP[2]
OD[2]
TPOH
OD[3]
NC
VDDODC
VDDI
VSSI
VSSODC
NC
OD[4]
NC
OD[5]
NC
OD[6]
NC
OD[7]
LOM[2]
ODP
NC
VDDOAC
VSSOAC
COUT
NC
VSST
VSST
VSST
PM5362
TUPP-PLUS
PIN 40
PIN 81
PIN 41
PIN 80
VSST
VSST
VSST
IC1J1
TCK
VDDI
TDI
IPL
TDO
VSSI
TRSTB
ITMF
TMS
ID[0]
NC
ID[1]
NC
ID[2]
NC
ID[3]
NC
ID[4]
LOM[3]
ID[5]
GSCLK[1]
ID[6]
POHFP[3]
ID[7]
VDDOAC
IDP
VDDODC
VDDI
VSSOAC
VSSI
VSSODC
POH[3]
POHEN[3]
VSST
VSST
VSST
5
ISSUE 6
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
10
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
6
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
BLOCK DIAGRAM
TCK
TMS
TDI
TRSTB
TDO
JTAG
Controller
SCLK
NSCLK
IBMODE
OBMODE
GSCLK[1:0]
Tributary
Payload
Processor
(VTPP)
IC1J1
IPL
ITMF
IDP
ID[7:0]
Input
Demux
Tributary
Payload
Processor
(VTPP)
Tributary
Payload
Processor
(VTPP)
Tributary
Path Overhead
Processor
(RTOP)
OTMF
OC1J1
OPL
ODP
OTPL
OTV5
OD[7:0]
Tributary
Trace Buffer
(RTTB)
Tributary
Path Overhead
Processor
(RTOP)
Output
Mux
Tributary
Trace Buffer
(RTTB)
Tributary
Path Overhead
Processor
(RTOP)
AIS
IDLE
COUT
TPOH
LC1J1V1
LPL
POH[3:1]
POHFP[3:1]
POHEN[3:1]
POHCK
RAD
LOM[3:1]
Tributary
Trace Buffer
(RTTB)
MBEB
RSTB
CSB
RDB
WRB
ALE
A[11:0]
Microprocessor
Interface
INTB
D[7:0]
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
11
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
7
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
PIN DESCRIPTION
Pin Name
Type
Pin
No.
Function
SCLK/
Input
153
The system clock (SCLK) provides timing for
TUPP-PLUS internal operations. SCLK is a
19.44 MHz, nominally 50% duty cycle, clock.
When either incoming interface is in nibble mode
(IBMODE set low) or the outgoing interface is in
nibble mode (OBMODE set low), SCLK must be
connected to GSCLK[0] externally.
In incoming byte interface mode (IBMODE set
high), IC1J1, IPL, ITMF, IDP, ID[7:0], OTMF,
OC1J1 and OPL are sampled on the rising edge
of SCLK. In outgoing byte interface mode
(OBMODE set high), ODP, OTPL, OTV5,
OD[7:0], AIS, IDLE, TPOH, LC1J1V1, LPL, and
LOM[3:1] are updated on the rising edge of
SCLK.
VCLK
The test vector clock (VCLK) signal is used
during TUPP-PLUS production testing to verify
manufacture.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
12
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
NSCLK
Input
147
The nibble interface mode system clock
(NSCLK) provides timing for TUPP-PLUS
internal operations in incoming or outgoing
nibble interface mode (IBMODE or OBMODE
set low). NSCLK is a 38.88 MHz, nominally 50%
duty cycle, clock.
In incoming nibble interface mode (IBMODE set
low), IC1J1, IPL, ITMF, IDP, ID[3:0] are sampled
on the rising edge of NSCLK. In outgoing nibble
interface mode (OBMODE set low), OTMF,
OC1J1 and OPL are sampled on the rising edge
of NSCLK, and ODP, OTPL, OTV5, OD[7:0],
AIS, IDLE, TPOH, LC1J1V1, LPL, and LOM[3:1]
are updated on the rising edge of NSCLK.
When the incoming and the outgoing interfaces
are in byte mode (IBMODE and OBMODE both
set high), NSCLK may be left unconnected.
NSCLK has an integral pull-up resistor.
IBMODE
Input
145
The incoming byte interface mode signal
(IBMODE) configures the incoming interface
mode of the TUPP-PLUS. When IBMODE is set
low, nibble interface mode is selected. SCLK
must be connected to GSCLK[0]. IC1J1, IPL,
ITMF, IDP, ID[3:0] are sampled on the rising
edge of NSCLK. When IBMODE is set high,
byte interface mode is selected. IC1J1, IPL,
ITMF, IDP, ID[7:0] are sampled on the rising
edge of SCLK. IBMODE has an integral pull-up
resister.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
13
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
OBMODE
Input
146
The outgoing byte interface mode signal
(OBMODE) configures the outgoing interface
mode of the TUPP-PLUS. When OBMODE is
set low, nibble interface mode is selected. SCLK
must be connected to GSCLK[0]. OTMF, OC1J1
and OPL are sampled on the rising edge of
NSCLK. ODP, OTPL, OTV5, OD[3:0], AIS, IDLE,
LC1J1V1, LPL, and LOM[3:1] are updated on
the rising edge of NSCLK. When OBMODE is
set high, byte interface mode is selected. OTMF,
OC1J1 and OPL are sampled on the rising edge
of SCLK. ODP, OTPL, OTV5, OD[7:0], AIS,
IDLE, LC1J1V1, LPL, and LOM[3:1] are updated
on the rising edge of SCLK. OBMODE has an
integral pull-up resister.
GSCLK[1]
Output
65
The generated system clock (GSCLK[1:0])
signals provide timing for the TUPP-PLUS when
nibble mode is selected at the incoming or
outgoing interface (IBMODE or OBMODE set
low). GSCLK[1:0] are a divide by two of NSCLK.
GSCLK[0] must only be connected to SCLK
externally when IBMODE or OBMODE is set
low. GSCLK[1] is a exact replica of GSCLK[0]
and can be used to supply timing to external
devices that are operating in byte mode.
GSCLK[1:0] are updated on the rising edge of
NSCLK.
GSCLK[0]
149
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
14
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
IC1J1
Input
44
The input C1/J1 frame pulse (IC1J1) identifies
the transport envelope and synchronous
payload envelope frame boundaries on the
incoming stream.
In incoming byte interface mode (IBMODE set
high), IC1J1 is set high while IPL is low to mark
the first C1 byte of the transport envelope frame
on the ID[7:0] bus. IC1J1 is set high while IPL is
high to mark each J1 byte of the synchronous
payload envelope(s) on the ID[7:0] bus. IC1J1
must be present at every occurrence of the first
C1 and all J1 bytes. The TUPP-PLUS will ignore
a pulse on IC1J1 at the byte position of the V1
byte of the first tributary of each VC3 or the top
byte of the first fixed stuff column of each TUG3.
IC1J1 is sampled on the rising edge of SCLK.
In incoming nibble interface mode (IBMODE set
low), IC1J1 is set high while IPL is low to mark
the more significant nibble of the first C1 byte of
the transport envelope frame on the ID[3:0] bus.
IC1J1 is set high while IPL is high to mark the
more significant nibble of each J1 byte of the
synchronous payload envelope(s) on the ID[3:0]
bus. IC1J1 must be present at every occurrence
of the first C1 and all J1 bytes. The TUPP-PLUS
will ignore a pulse on IC1J1 at the byte position
of the V1 byte of the first tributary of each VC3
or the top byte of the first fixed stuff column of
each TUG3. IC1J1 must be set low during the
less significant nibble timeslots. IC1J1 is
sampled on the rising edge of NSCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
15
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
IPL
Input
48
The active high incoming payload active (IPL)
signal identifies the bytes within the transport
envelope frame on the incoming stream that
carry the VC3 or VC4 virtual containers, or the
STS-1 synchronous payload envelopes.
In incoming byte interface mode (IBMODE set
high), IPL must be brought high to mark each
payload byte on ID[7:0]. IPL is sampled on the
rising edge of SCLK.
In incoming nibble interface mode (IBMODE set
low), IPL must be brought high to mark the more
significant nibble of each payload byte on
ID[3:0]. IPL is ignored during the less significant
nibble timeslots. IPL is sampled on the rising
edge of NSCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
16
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
ITMF
Input
52
The active high incoming tributary multiframe
(ITMF) signal identifies the first frame of the
tributary multiframe for each STS-1 synchronous
payload envelope, AU3, or AU4 administrative
unit. ITMF is enabled by the setting the ITMFEN
register bit high. When ITMFEN bit is low, the
path overhead H4 byte is used to determine
tributary multiframe boundaries. ITMF is
selectable to pulse high during the third byte
after J1 of the first tributary or during the H4
byte which indicates that the next frame is the
first frame of the tributary multiframe. Selection
between marking each H4 or the third byte after
each J1 is controlled by the ITMFH4 register bit.
Pulses on ITMF are only effective during the H4
or third byte after each J1 byte positions, as
appropriate. ITMF is ignored at other byte
positions.
In incoming byte interface mode (IBMODE set
high), ITMF is sampled on the rising edge of
SCLK.
In incoming nibble interface mode (IBMODE set
low), ITMF marks the more significant nibble of
H4 or the third byte after J1, as appropriate. It is
ignored at the less significant nibble timeslots.
ITMF is sampled on the rising edge of NSCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
17
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
IDP
Input
70
The incoming data parity (IDP) signal carries the
parity of the incoming signals.
In incoming byte interface mode (IBMODE set
high), the parity calculation encompasses the
ID[7:0] bus and optionally the IC1J1 and the IPL
signals. IC1J1 and IPL can be included in the
parity calculation by setting the INCC1J1 and
INCPL register bits high, respectively. Odd
parity is selected by setting the IOP register bit
high, and even parity is selected by setting the
IOP bit low. IDP is sampled on the rising edge
of SCLK.
In incoming nibble interface mode (IBMODE set
low), The parity calculation encompasses the
ID[3:0] bus and optionally the IC1J1 and the IPL
signals. IC1J1 and IPL can be included in the
parity calculation by setting the INCC1J1 and
INCPL register bits high, respectively. Odd
parity is selected by setting the IOP register bit
high, and even parity is selected by setting the
IOP bit low. IDP is sampled on the rising edge
of NSCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
18
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
ID[0]
Input
54
The incoming data bus (ID[7:0]) carries
SONET/SDH frame data in byte serial format.
ID[1]
56
ID[2]
58
ID[3]
60
ID[4]
62
ID[5]
64
ID[6]
66
ID[7]
68
In incoming byte interface mode (IBMODE set
high), ID[7] is the most significant bit,
corresponding to bit 1 of each serial word, the
bit transmitted first. ID[0] is the least significant
bit, corresponding to bit 8 of each serial word,
the last bit transmitted. The ID[7:0] bus is
sampled on the rising edge of SCLK.
In incoming nibble interface mode (IBMODE set
low), ID[3] is the most significant bit of each
nibble, corresponding to bit 1 or bit 5 of each
serial word, the bit transmitted first and fifth,
respectively. ID[0] is the least significant bit of
each nibble, corresponding to bit 4 or bit 8 of
each serial word, the fourth or last bit
transmitted, respectively. ID[7:4] is ignored. The
ID[3:0] bus is sampled on the rising edge of
NSCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
19
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
OC1J1
Input
127
The outgoing composite frame pulse (OC1J1) marks
the transport frame and synchronous payload
envelope frame boundaries on the outgoing stream.
In outgoing byte interface mode (OBMODE set high),
and the OJ1EN register bit is set low, OC1J1 pulses
high to mark the first C1 byte of the transport
envelope frame on the OD[7:0] bus. The OPL input
must be held low. The position of the J1 byte(s) is
implicit and fixed to the bytes immediately following
the last C1 byte. When the OJ1EN register bit is set
high, the OC1J1 signal pulses high while OPL is low
to mark the first C1 byte of the transport frame on
the OD[7:0] bus and pulses high while OPL is high to
mark each of the J1 bytes of the synchronous
payload envelope(s) on the OD[7:0] bus. OC1J1
must be present at every occurrence of the first C1
byte and all J1 bytes. A V1 pulse added to the
OC1J1 input will be ignored by the TUPP-PLUS.
OC1J1 is sampled on the rising edge of SCLK.
In outgoing nibble interface mode (OBMODE set
low), and the OJ1EN register bit is set low, OC1J1
pulses high to mark the more significant nibble of the
first C1 byte of the transport envelope frame on the
OD[3:0] bus. The OPL input must be held low. The
position of the J1 byte(s) is implicit and fixed to the
bytes immediately following the last C1 byte. When
the OJ1EN register bit is set high, the OC1J1 signal
pulses high while OPL is low to mark the more
significant nibble of the first C1 byte of the transport
frame on the OD[3:0] bus and pulses high while OPL
is high to mark each of the J1 bytes of the
synchronous payload envelope(s) on the OD[3:0]
bus. OC1J1 must be present at every occurrence of
the first C1 byte and all J1 bytes. A V1 pulse added
to the OC1J1 input will be ignored by the TUPPPLUS. OC1J1 must be set low during the less
significant nibble timeslots. OC1J1 is sampled on
the rising edge of NSCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
20
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
OTMF
Input
125
The active high outgoing tributary multiframe
(OTMF) signal identifies the first frame of the
tributary multiframe for each AU3, or AU4
administrative unit, or STS-1 synchronous
payload envelope. OTMF is selectable to pulse
high during the third byte after J1 of the first
tributary or during the H4 byte of the path
overhead which indicates that the next frame is
the first frame of the tributary multiframe.
Selection between marking the third byte after
each J1 or H4 bytes is controlled by the
OTMFH4 bit. Pulses on OTMF are only effective
during the H4 or third byte after each J1 byte
positions, as appropriate. OTMF is ignored at
other byte positions.
In outgoing byte interface mode (OBMODE set
high), OTMF is sampled on the rising edge of
SCLK.
In outgoing nibble interface mode (OBMODE set
low), OTMF is ignored at the less significant
nibble timeslots. OTMF is sampled on the rising
edge of NSCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
21
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
COUT
Output
85
The controlled output signal (COUT) is a
software programmable output that is controlled
by the COUTx register bit associated with each
tributary.
In outgoing byte interface mode (OBMODE set
high), COUT is synchronized to the OD[7:0] bus.
In floating mode, COUT contains valid data only
for bytes in the VC3 or VC4 virtual container(s),
or the STS-1 synchronous payload envelopes.
Its contents should be ignored for bytes in the
transport overhead. In locked mode, COUT is
set low for transport overhead bytes. COUT is
updated on the rising edge of SCLK.
In outgoing nibble interface mode (OBMODE set
low), COUT is synchronized to the OD[3:0] bus.
In floating mode, COUT contains valid data only
for bytes in the VC3 or VC4 virtual container(s),
or the STS-1 synchronous payload envelopes.
Its contents should be ignored for bytes in the
transport overhead. In locked mode, COUT is
set low for transport overhead bytes. COUT is
updated on the rising edge of NSCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
22
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
OPL
Input
132
The active high outgoing payload active (OPL) signal
identifies the bytes within the transport envelope frame on
the OD[7:0] bus that carry the VC3 or VC4 virtual
container(s), and the STS-1 synchronous payload
envelopes.
In outgoing byte interface mode (OBMODE set high), and
floating mode is enabled, OPL must be set high to mark
each payload byte. OD[7:0], OTPL, OTV5, AIS and IDLE
contain valid data only for bytes in the VC3 or VC4 virtual
container(s), or the STS-1 synchronous payload
envelopes. Their contents should be ignored for bytes in
the transport overhead as indicated by a low level on the
OPL input. In locked mode, the outgoing virtual container
(synchronous payload envelope) is locked with the J1 byte
immediately following the C1 byte and OPL should be held
low. During transport overhead byte locations on the
outgoing stream, OTPL, OTV5, AIS and IDLE are set low.
OD[7:0] is set to a valid pointer with offset of 522 and allzeros for other transport overhead bytes. OPL is sampled
on the rising edge of SCLK.
In outgoing nibble interface mode (OBMODE set low), and
floating mode is enabled, OPL must be set high to mark
the more significant nibble of each payload byte. OPL is
ignored during the less significant nibble. OD[3:0], OTPL,
OTV5, AIS and IDLE contain valid data only for bytes in
the VC3 or VC4 virtual container(s), or the STS-1
synchronous payload envelopes. Their contents should be
ignored for bytes in the transport overhead as indicated by
a low level on the OPL input. In locked mode, the outgoing
virtual container (synchronous payload envelope) is locked
with the J1 byte immediately following the C1 byte and
OPL should be held low. During transport overhead byte
locations on the outgoing stream, OTPL, OTV5, AIS and
IDLE are set low. OD[3:0] is set to a valid pointer with
offset of 522 and all-zeros for other transport overhead
bytes. OPL is ignored during the less significant nibble
timeslots. OPL is sampled on the rising edge of NSCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
23
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
OD[0]
Output
110
The outgoing data bus (OD[7:0]) carries
SONET/SDH frame data in byte serial format.
OD[1]
108
OD[2]
106
OD[3]
104
OD[4]
97
OD[5]
95
OD[6]
93
OD[7]
91
In outgoing byte interface mode (OBMODE set
high), OD[7] is the most significant bit,
corresponding to bit 1 of each serial word, the
bit transmitted first. OD[0] is the least significant
bit, corresponding to bit 8 of each serial word,
the last bit transmitted. In floating mode,
OD[7:0] contains valid data only for bytes in the
VC3 or VC4 virtual container(s), or the STS-1
synchronous payload envelopes. Its contents
should be ignored for bytes in the transport
overhead. In locked mode, OD[7:0] is set to allzeros at transport overhead bytes, except for a
valid pointer with offset 522 at H1, H2 bytes.
The OD[7:0] bus is updated on the rising edge
of SCLK.
In outgoing nibble interface mode (OBMODE set
low), OD[3] is the most significant bit of each
nibble, corresponding to bit 1 or bit 5 of each
serial word, the bit transmitted first or fifth,
respectively. OD[0] is the least significant bit,
corresponding to bit 4 or bit 8 of each serial
word, the fourth or last bit transmitted,
respectively. OD[7:4] are set low. In floating
mode, OD[3:0] contains valid data only for bytes
in the VC3 or VC4 virtual container(s), or the
STS-1 synchronous payload envelopes. Its
contents should be ignored for bytes in the
transport overhead. In locked mode, OD[3:0] is
set to all-zeros at transport overhead bytes,
except for a valid pointer with offset 522 at H1,
H2 bytes. The OD[7:0] bus is updated on the
rising edge of NSCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
24
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
ODP
Output
89
The outgoing data parity (ODP) signal carries
the parity of the outgoing data stream, OD[7:0].
Odd parity is selected by setting the OOP
register bit high, and even parity is selected by
setting the OOP bit low. ODP is updated on the
rising of SCLK in outgoing byte interface mode
(OBMODE set high) and on the rising edge of
NSCLK in outgoing nibble interface mode
(OBMODE set low).
OTPL
Output
134
The outgoing tributary payload active (OTPL)
signal marks the bytes carrying the tributary
payload.
In outgoing byte interface mode (OBMODE set
high), OTPL is set high to mark each tributary
payload byte on the OD[7:0] bus. In floating
mode, OTPL contains valid data only for bytes in
the VC3 or VC4 virtual container(s), or the
STS-1 synchronous payload envelopes. Its
contents should be ignored for bytes in the
transport overhead. In locked mode, OTPL is
set low for transport overhead. OTPL is updated
on the rising edge of SCLK.
In outgoing nibble interface mode (OBMODE set
low), OTPL is set high to mark each tributary
payload byte on the OD[3:0] bus. In floating
mode, OTPL contains valid data only for bytes in
the VC3 or VC4 virtual container(s), or the
STS-1 synchronous payload envelopes. Its
contents should be ignored for bytes in the
transport overhead. In locked mode, OTPL is
set low for transport overhead. OTPL is updated
on the rising edge of NSCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
25
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
OTV5
Output
136
The outgoing tributary V5 byte (OTV5) signal
marks the various tributary V5 bytes.
In outgoing byte interface mode (OBMODE set
high), OTV5 is set high to mark each tributary
V5 byte on the OD[7:0] bus. When the outgoing
tributary is a TU3, OTV5 marks the J1 byte of
the TU3. In floating mode, OTV5 contains valid
data only for bytes in the VC3 or VC4 virtual
container(s), or the STS-1 synchronous payload
envelopes. Its contents should be ignored for
bytes in the transport overhead. In locked
mode, OTV5 is set low for transport overhead
bytes. OTV5 is updated on the rising edge of
SCLK.
In outgoing nibble interface mode (OBMODE set
low), OTV5 is set high to mark each tributary V5
byte on the OD[3:0] bus. When the outgoing
tributary is a TU3, OTV5 marks the J1 byte of
the TU3. In floating mode, OTV5 contains valid
data only for bytes in the VC3 or VC4 virtual
container(s), or the STS-1 synchronous payload
envelopes. Its contents should be ignored for
bytes in the transport overhead. In locked
mode, OTV5 is set low for transport overhead
bytes. OTV5 is updated on the rising edge of
NSCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
26
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
AIS
Output
114
The tributary alarm indication signal output (AIS)
marks tributaries on the outgoing stream that
are in AIS state.
In outgoing byte interface mode (OBMODE set
high), AIS is set high when AIS is inserted in the
associated tributary on the OD[7:0] and is set
low when the AIS is not inserted. In floating
mode, AIS contains valid data only for bytes in
the VC3 or VC4 virtual container(s), or the
STS-1 synchronous payload envelopes. Its
value should be ignored for bytes in the
transport overhead. In locked mode, AIS is set
low for transport overhead bytes. AIS is updated
on the rising edge of SCLK.
In outgoing nibble interface mode (OBMODE set
low), AIS is set high when AIS is inserted in the
associated tributary on the OD[3:0] and is set
low when the AIS is not inserted. In floating
mode, AIS contains valid data only for bytes in
the VC3 or VC4 virtual container(s), or the
STS-1 synchronous payload envelopes. Its
value should be ignored for bytes in the
transport overhead. In locked mode, AIS is set
low for transport overhead bytes. AIS is updated
on the rising edge of NSCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
27
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
IDLE
Output
115
The tributary idle indication signal output (IDLE)
marks tributaries on the outgoing stream that
are in idle state.
In outgoing byte interface mode (OBMODE set
high), IDLE is set high when idle code is
inserted in the associated tributary on the
OD[7:0] and is set low when the idle code is not
inserted. In floating mode, IDLE contains valid
data only for bytes in the VC3 or VC4 virtual
container(s), or the STS-1 synchronous payload
envelopes. Its value should be ignored for bytes
in the transport overhead. In locked mode, IDLE
is set low for transport overhead bytes. IDLE is
updated on the rising edge of SCLK.
In outgoing nibble interface mode (OBMODE set
low), IDLE is set high when idle code is inserted
in the associated tributary on the OD[3:0] and is
set low when the idle code is not inserted. In
floating mode, IDLE contains valid data only for
bytes in the VC3 or VC4 virtual container(s), or
the STS-1 synchronous payload envelopes. Its
value should be ignored for bytes in the
transport overhead. In locked mode, IDLE is set
low for transport overhead bytes. IDLE is
updated on the rising edge of NSCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
28
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
TPOH
Output
105
The outgoing tributary path overhead byte
(OTV5) signal marks the tributary path overhead
bytes in the outgoing stream. For streams in
TU3 mode, the J1, B3,C2, G1, F2, H4, Z3, Z4
and Z5 bytes are marked. For streams out of
TU3 mode, V5, J2, Z6 an Z7 bytes are marked.
In outgoing byte interface mode (OBMODE set
high), TPOH is set high to mark each tributary
path overhead byte on the OD[7:0] bus. In
floating mode, TPOH contains valid data only for
bytes in the VC3 or VC4 virtual container(s), or
the STS-1 synchronous payload envelopes. Its
contents should be ignored for bytes in the
transport overhead. In locked mode, TPOH is
set low for transport overhead bytes. TPOH is
updated on the rising edge of SCLK.
In outgoing nibble interface mode (OBMODE set
low), TPOH is set high to mark each tributary
path overhead byte on the OD[3:0] bus. In
floating mode, TPOH contains valid data only for
bytes in the VC3 or VC4 virtual container(s), or
the STS-1 synchronous payload envelopes. Its
contents should be ignored for bytes in the
transport overhead. In locked mode, TPOH is
set low for transport overhead bytes. TPOH is
updated on the rising edge of NSCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
29
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
LOM[3]
Output
63
The loss of multiframe signals (LOM[3:1])
reports the tributary multiframe synchronization
status. LOM is set low when a correct sequence
on the H4 byte has been detected for four
frames. LOM is set high if a correct four frame
sequence is not detected in 1 millisecond.
LOM[3], LOM[2] and LOM[1] report the
synchronization status of STS-1 #1, #2 and #3,
respectively. In AU4 mode, LOM[3], LOM[2] and
LOM[1] report the synchronization status of
TUG3 #1, #2 and #3, respectively. LOM[3:1] are
updated on the rising edge of SCLK.
LOM[2]
90
LOM[1]
144
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
30
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
LC1J1V1
Output
141
The locked mode composite frame pulse
(LC1J1V1) marks the transport, synchronous
payload envelope and tributary multiframe frame
boundaries on the outgoing stream. LC1J1V1 is
only active in locked mode (OJ1EN register bit
set low). LC1J1V1 is held low in floating mode
(OJ1EN set high).
In outgoing byte interface mode (OBMODE set
high), and locked mode is enabled (OJ1EN set
low), LC1J1V1 pulses high to mark the first C1
byte of the transport envelope frame on the
OD[7:0] bus. It also pulses high to mark the J1
byte(s) which is (are) register selectable to be
implicitly fixed to immediately follow the C1 bytes
or the H3 bytes. Optionally, LC1J1V1 also
marks the third byte after J1 of the first tributary
in each STS-1 (TUG3) stream when the LV1EN
register bit is set high. LC1J1V1 is updated on
the rising edge of SCLK.
In outgoing nibble interface mode (OBMODE set
low), and locked mode is enabled (OJ1EN set
low), LC1J1V1 pulses high to mark the more
significant nibble of the first C1 byte of the
transport envelope frame on the OD[3:0] bus. It
also pulses high to mark the more significant
nibble of the J1 byte(s) which is (are) register
selectable to be implicitly fixed to immediately
follow the C1 bytes or the H3 bytes. Optionally,
LC1J1V1 also marks the more significant nibble
of the third byte after J1 of the first tributary in
each STS-1 (TUG3) stream when the LV1EN
register bit is set high. LC1J1V1 is updated on
the rising edge of NSCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
31
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
LPL
Output
140
The locked mode payload active signal (LPL)
identifies synchronous payload envelope bytes
on the outgoing stream. LPL is only active in
locked mode (OJ1EN register bit set low). LPL
is held low in floating mode (OJ1EN set high). If
locked mode is enabled (OJ1EN set low), LPL is
set high to mark synchronous payload envelop
bytes and set low to mark transport overhead
bytes. LPL is updated on the rising edge of
SCLK in outgoing byte interface mode
(OBMODE set high) or on the rising edge of
NSCLK in outgoing nibble interface mode
(OBMODE set low).
POHCK
Output
126
The tributary path overhead clock signal
(POHCK) provides timing to sample the
extracted tributary path overhead stream and
the receive alarm port. POHCK is nominally
9.72 MHz clock signals. The POH[3:1],
POHEN[3:1], POHFP[3:1] and RAD outputs are
updated on the falling edge of POHCK.
POH[3]
Output
76
The tributary path overhead signals (POH[3:1])
contains the tributary path overhead bytes (V5,
J2, Z6 and Z7) extracted from the ID[7:0] bus.
POH[3], POH[2] and POH[1] contain the
tributary path overhead bytes from STS-1 #1, #2
and #3, respectively. In AU4 mode, POH[3],
POH[2] and POH[1] contain the tributary path
overhead bytes from TUG3 #1, #2 and #3,
respectively. All four tributary overhead bytes of
each tributary is shifted out once per payload
frame. The corresponding POHEN signal is set
high to identify overhead bytes that are
presented for the first time. Each POH signal is
updated on the falling edge of POHCK.
POH[2]
109
POH[1]
135
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
32
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
POHFP[3]
Output
67
The tributary path overhead frame pulse signals
(POHFP[3:1]) may be used to locate the
individual path overhead bits of each tributary
for the corresponding STS-1 (TUG3) stream.
Each POHFP signal is set high to mark bit 1 (the
most significant bit) of the V5 byte of the first
tributary. POHFP[3], POHFP[2] and POHFP[1]
identify frame boundaries of the tributary path
overhead bytes from STS-1 #1, #2 and #3,
respectively. In AU4 mode, POHFP[3],
POHFP[2] and POHFP[1] identify frame
boundaries of TUG3 #1, #2 and #3, respectively.
Each POHFP signal is updated on the falling
edge of POHCK.
POHFP[2]
107
POHFP[1]
133
POHEN[3]
Output
77
POHEN[2]
111
POHEN[1]
139
RAD
Output
124
The tributary path overhead enable signals
(POHEN[3:1]) may be used to identify tributary
path overhead bytes that are being presented
on the corresponding POH stream for the first
time. Each POHEN signal is set high when a
fresh overhead byte is available on the
corresponding POH stream. POHEN is set low
when the tributary path overhead byte available
on the corresponding POH stream has already
been shifted out in a previous frame.
POHEN[3], POHEN[2] and POHEN[1] identify
the status of tributary path overhead bytes from
STS-1 #1, #2 and #3, respectively. In AU4
mode, POHFP[3], POHFP[2] and POHFP[1]
identify the status of tributary path overhead
bytes from TUG3 #1, #2 and #3, respectively.
Each POHEN signal is updated on the falling
edge of POHCK.
The receive alarm port (RAD) contains the
tributary path BIP error count, the RDI status
and the PDI status of each tributary in the
ID[7:0] bus. RAD is updated on the falling edge
of POHCK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
33
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
MBEB
Input
14
The active low Motorola bus enable (MBEB)
signal configures the TUPP-PLUS for Motorola
bus mode where the RDB/E signal functions as
E, and the WRB/RWB signal functions as RWB.
When MBEB is high, the TUPP-PLUS is
configured for Intel bus mode where the RDB/E
signal functions as RDB. The MBEB input has
an integral pull up resistor.
CSB
Input
13
The active low chip select (CSB) signal is low
during TUPP-PLUS register accesses. If CSB is
not required (i.e., register accesses are
controlled by using the RDB/E and WRB/RWB
signals only), CSB must be connected to an
inverted version of RSTB.
RDB/
Input
35
The active low read enable (RDB) signal is low
during TUPP-PLUS register read accesses while
in Intel bus mode. The TUPP-PLUS drives the
D[7:0] bus with the contents of the addressed
register while RDB and CSB are low.
E
The active high external access (E) signal is
high during TUPP-PLUS register access while in
Motorola bus mode.
WRB/
RWB
Input
37
The active low write strobe (WRB) signal is low
during a TUPP-PLUS register write accesses
while in Intel bus mode. The D[7:0] bus contents
are clocked into the addressed register on the
rising WRB edge while CSB is low.
The read/write select (RWB) signal selects
between TUPP-PLUS register read and write
accesses while in Motorola bus mode. The
TUPP-PLUS drives the D[7:0] bus with the
contents of the addressed register while CSB is
low and RWB and E are high. The D[7:0] bus
contents are clocked into the addressed register
on the falling E edge while CSB and RWB are
low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
34
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
D[0]
I/O
15
The bidirectional data bus D[7:0] is used during
TUPP-PLUS register read and write accesses.
D[1]
16
D[2]
17
D[3]
18
D[4]
23
D[5]
24
D[6]
25
D[7]
26
A[0]
Input
4
The address bus A[11:0] selects specific
registers during TUPP-PLUS register accesses.
A[1]
5
A[2]
6
A[3]
7
A[4]
8
A[5]
9
A[6]
10
A[7]
11
A[8]
12
A[9]
157
A[10]
156
A[11]/TRS
34
The test register select (TRS) signal selects
between normal and test mode register
accesses. TRS is high during test mode register
accesses, and is low during normal mode
register accesses.
31
The active low reset (RSTB) signal provides an
asynchronous TUPP-PLUS reset. RSTB is a
Schmitt triggered input with an integral pull up
resistor.
RSTB
Input
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
35
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
ALE
Input
33
The address latch enable (ALE) is active high
and latches the address bus A[7:0] when low.
When ALE is high, the internal address latches
are transparent. It allows the TUPP-PLUS to
interface to a multiplexed address/data bus.
ALE has an integral pull up resistor.
INTB
OD
28
The active low interrupt (INTB) signal goes low
when a TUPP-PLUS interrupt source is active.
INTB returns high when the interrupt is
acknowledged via an appropriate register
access. INTB is an open drain output.
Output
TCK
Input
45
The test clock (TCK) signal provides timing for
test operations that can be carried out using the
IEEE P1149.1 test access port. TCK has an
integral pull up resistor.
TMS
Input
53
The test mode select (TMS) signal controls the
test operations that can be carried out using the
IEEE P1149.1 test access port. TMS is sampled
on the rising edge of TCK. TMS has an integral
pull up resistor.
TDI
Input
47
The test data input (TDI) signal carries test data
into the device via the IEEE P1149.1 test access
port. TDI is sampled on the rising edge of TCK.
TDI has an integral pull up resistor.
TDO
Tristate
49
The test data output (TDO) signal carries test
data out of the device via the IEEE P1149.1 test
access port. TDO is updated on the falling edge
of TCK. TDO is a tristate output that is always
tristated except when scanning of data is in
progress.
TRSTB
Input
51
The active low test reset (TRSTB) signal
provides an asynchronous test access port
reset. TRSTB is a Schmitt triggered input with
an integral pull up resistor. TRSTB must be
asserted during the power up sequence.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
36
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
VDDI1
Power
20
The core power (VDDI1 - VDDI7) pins should be
connected to a well decoupled +5 V DC in
common with VDDOAC and VDDODC.
VDDI2
46
VDDI3
72
VDDI4
101
VDDI5
131
VDDI6
143
VDDI7
155
VSSI1
Ground
21
VSSI2
50
VSSI3
74
VSSI4
100
VSSI5
128
VSSI6
142
VSSI7
151
VDDOAC1
Power
27
VDDOAC2
69
VDDOAC3
87
VDDOAC4
113
VDDOAC5
130
VDDOAC6
148
VSSOAC1
Ground
29
VSSOAC2
73
VSSOAC3
86
VSSOAC4
112
VSSOAC5
129
VSSOAC6
150
The core ground (VSSI1 - VSSI7) pins should be
connected to GND in common with VSSOAC
and VSSODC.
The pad ring switching power (VDDOAC1 VDDOAC6) pins should be connected to a well
decoupled +5 V DC in common with VDDI and
VDDODC.
The pad ring ground (VSSOAC1 - VSSOAC6)
pins should be connected to GND in common
with VSSI and VSSODC
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
37
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
VDDODC1
Power
19
The pad ring static power (VDDODC1 VDDODC7) pins should be connected to a well
decoupled +5 V DC in common with VDDI and
VDDOAC.
VDDODC2
32
VDDODC3
71
VDDODC4
102
VDDODC5
117
VDDODC6
137
VDDODC7
154
VSSODC1
Ground
22
VSSODC2
30
VSSODC3
75
VSSODC4
99
VSSODC5
116
VSSODC6
138
VSSODC7
152
The pad ring ground (VSSODC1 - VSSODC7)
pins should be connected to GND in common
with VSSI and VSSOAC.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
38
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Pin Name
Type
Pin
No.
Function
VSST1
Ground
1
The thermal ground (VSST1 - VSST24) pins
should be connected to GND in common with
VSSI and VSSOAC.
VSST2
2
VSST3
3
VSST4
38
VSST5
39
VSST6
40
VSST7
41
VSST8
42
VSST9
43
VSST10
78
VSST11
79
VSST12
80
VSST13
81
VSST14
82
VSST15
83
VSST16
118
VSST17
119
VSST18
120
VSST19
121
VSST20
122
VSST21
123
VSST22
158
VSST23
159
VSST24
160
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
39
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Notes on Pin Description:
1. All TUPP-PLUS inputs and bidirectionals present minimum capacitive loading
and operate at TTL logic levels.
2. All TUPP-PLUS digital outputs and bidirectionals have 4 mA drive capability,
except the INTB open drain output, the D[7:0] bidirectionals, the POHCK
output and the GSCLK[1] output have 8 mA drive capability.
3. The VSSOAC ground pins are not internally connected to the VSSODC nor
the VSSI ground pins. Failure to connect these pins externally may cause
malfunction or damage the TUPP-PLUS. The VSSODC and the VSSI ground
pins are internally connected.
4. The VDDOAC power pins are not internally connected to the VDDODC nor
the VDDI power pins. Failure to connect these pins externally may cause
malfunction or damage the TUPP-PLUS. The VDDODC and the VDDI power
pins are internally connected.
5. Pin numbers that are underlined are additions to the TUPP-PLUS that were
no-connects in the TUPP (PM5361).
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
40
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
8
FUNCTIONAL DESCRIPTION
8.1
Input Bus Demultiplexer
The input bus demultiplexer captures data sampled on the ID[7:0] bus and
distributes this data to the three tributary payload processors within the
TUPP-PLUS.
The input bus demultiplexer also provides timing signals for the other blocks
within the TUPP-PLUS. Frame alignment signals for the incoming data stream,
IC1J1, ITMF, and IPL, are sampled, buffered and distributed to the tributary
payload processors (VTPPs). In order to have synchronous operation of the
VTPPs with a single clock, the incoming data and control signals may be delayed
by up to two system clock cycles before distribution to the VTPPs. The delay is
used to align the incoming data with the outgoing data at each VTPP. The
amount of delay is adjusted such that the separation of the incoming STS/AU
frame and the outgoing frame at each VTPP appears to be in multiples of three
SCLK or six NSCLK periods.
When configured for AU4 mode, the input bus demultiplexer provides the
necessary timing coordination between the three tributary payload processors.
The single J1 byte marker input on IC1J1 is retimed and distributed to each of
the three tributary payload processors. The tributary multiframe detected by
VTPP #1 is distributed to the two other VTPPs, as VTPP #1 is the only one
receiving a valid H4 byte.
8.2
Output Bus Multiplexer
The output bus multiplexer gathers payload data from the three tributary payload
processors within the TUPP-PLUS and multiplexes this data onto the OD[7:0]
bus. It also multiplexes signals from each tributary payload processor that mark
tributary SPEs and tributary V5 bytes onto the shared OTPL and OTV5 signals.
The extracted tributary path overhead serial signals (POH[3:1], POHFP[3:1],
POHEN[3:1], POHCK[3:1] and RAD) are buffered by the output bus multiplexer
block.
The output bus multiplexer also provides timing signals for other blocks within the
TUPP-PLUS. Frame alignment signals for the outgoing data stream, OC1J1,
OPL and OTMF, are sampled, buffered and distributed to the tributary payload
processors (VTPPs), the tributary path overhead processors (RTOPs) and the
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
41
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
tributary trace buffers (RTTBs). The output bus multiplexer contains a four frame
counter that will flywheel in the absence of an active OTMF input, internally
generating tributary multiframe timing for the outgoing data stream. When
configured for locked output mode, i.e. when OJ1EN is low, the output bus
multiplexer will internally generate J1 and SPE timing for the outgoing data
stream that corresponds to the J1 bytes following the C1 bytes and no pointer
justifications at the STS-1 (AU3) or AU4 level. The locked transport and payload
frame boundaries are reported on the LC1J1V1 and LPL outputs. This timing
drives the outputs of the three VTPPs, RTOPs and RTTBs, substituting for the
function otherwise provided by the OC1J1 and OPL inputs.
When configured for AU4 mode, the output bus multiplexer provides the
necessary timing coordination between the three tributary payload processors.
This consists of deriving VC4 framing from the single J1 byte marker input on
OC1J1 and distributing this to each VTPP, RTOP and RTTB blocks.
8.3
Tributary Payload Processor
Each tributary payload processor (VTPP) processes the tributaries within an
STS-1, AU3, or TUG3. Each VTPP can be configured to process any legal mix of
VT1.5s, VT2s, VT3s, or VT6s that can be carried in an STS-1 or any legal mix of
TU11s, TU12s, TU2s, or TU3s, that can be carried in an AU3 or TUG3. The
number of tributaries managed by each VTPP ranges from 1 (when configured to
process a single TU3) to 28 (when configured to process all VT1.5s or
equivalently all TU11s).
8.3.1 Clock Generator
The clock generator derives various clocks from the 19.44 MHz system clock and
distributes them to other blocks within the tributary payload processor. The
overall design is totally synchronous, with processing occurring at a 6.48 MHz
rate in each tributary payload processor.
8.3.2 Incoming Timing Generator
The incoming timing generator identifies the incoming tributary being processed
at any given point in time. Based on the configuration of the VTPP (it can
process various mixes of tributary types), the incoming timing generator extracts
the STS-1 SPE, VC3, or a single TUG3 from a VC4, and identifies the bytes
within these envelopes that correspond to various types of overhead and those
that carry specific tributaries to be processed. The H4 byte is identified for the
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
42
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
incoming multiframe detector so that it can determine the incoming tributary
multiframe boundaries. The identification of specific tributaries allows the pointer
interpreter to be time-sliced across the mix of tributaries present in the incoming
data stream. The identification of the V1-V3 bytes of VTs, or TUs (or H1-H3 bytes
in the case of TU3s) allows the pointer interpreter to function.
8.3.3 Incoming Multiframe Detector
The multiframe alignment sequence in the path overhead H4 byte is monitored
for the bit patterns of 00, 01, 10, 11 in the two least significant bits. If an
unexpected value is detected, the primary multiframe will be kept, and a second
multiframe process will, in parallel, check for a phase shift. The primary process
will enter out of multiframe state (OOM). A new multiframe alignment is chosen,
and OOM state is exited when four consecutive correct multiframe patterns are
detected. Loss of multiframe (LOM) is declared after residing in the OOM state
at the ninth H4 byte without re-alignment. In counting to nine, the out of
sequence H4 byte that triggered the transition to the OOM state is counted as
the first. A new multiframe alignment is chosen, and LOM state is exited when
four consecutive correct multiframe patterns are detected. Changes in
multiframe alignments are detected and reported.
8.3.4 Pointer Interpreter
The pointer interpreter is a time-sliced state machine that can process up to 28
independent tributaries. The state vector is saved in RAM as directed by the
incoming timing generator. The pointer interpreter processes the incoming
tributary pointers such that all bytes within the tributary synchronous payload
envelope can be identified and written into the unique payload first-in first-out
buffer for the tributary in question. A marker that tags the V5 byte (or J1 byte in
the case of a TU3) is passed through the payload buffer. The incoming timing
generator directs the pointer interpreter to the correct payload buffer for the
tributary being processed.
The pointer interpreter processes the incoming pointers (V1/V2 or H1/H2 in TU3
mode) as specified in the references. The pointer value is used to determine the
location of the tributary path overhead byte (V5 or J1 in TU3) in the incoming
TUG3 or STS-1 (AU3) stream. The algorithm can be modeled by a finite state
machine. Within the pointer interpretation algorithm three states are defined (as
shown in Figure 1):
NORM_state (NORM)
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
43
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
AIS_state (AIS)
LOP_state (LOP)
The transition between states will be consecutive events (indications), e.g., three
consecutive AIS indications to go from the NORM_state to the AIS_state. The
kind and number of consecutive indications activating a transition is chosen such
that the behaviour is stable and insensitive to low BER. The only transition on a
single event is the one from the AIS_state to the NORM_state after receiving a
NDF enabled with a valid pointer value. It should be noted that, since the
algorithm only contains transitions based on consecutive indications, this implies
that, for example, non-consecutively received invalid indications do not activate
the transitions to the LOP_state.
Figure 1
- Pointer Interpretation State Diagram
3 x eq_new_point
inc_ind /
dec_ind
NDF_enable
NORM
3x
le
int
_po
F_e
eq_
new
t
le
ND
oin
ab
3x
d
8x
_p
nab
nt
poi
ew
en
inv_
_n
F_
_in
AIS
8x
eq
ND
3x
3 x AIS_ind
LOP
AIS
8 x inv_point
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
44
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
The following events (indications) are defined
norm_point :
disabled NDF + ss + offset value equal to active offset
NDF_enable:
enabled NDF + ss + offset value in range for the configured
tributary type
AIS_ind:
H1 = 'hFF, H2 = 'hFF
inc_ind:
disabled NDF + ss + majority of I bits inverted + no majority
of D bits inverted + previous NDF_enable, inc_ind or
dec_ind more than 3 frames ago
dec_ind:
disabled NDF + ss + majority of D bits inverted + no majority
of I bits inverted + previous NDF_enable, inc_ind or dec_ind
more than 3 frames ago
inv_point:
not any of above (i.e., not norm_point, and not NDF_enable,
and not AIS_ind, and not inc_ind and not dec_ind)
new_point:
disabled_NDF + ss + offset value in range for the configured
tributary type but not equal to active offset
inc_req:
disabled NDF + ss + majority of I bits inverted + no majority
of D bits inverted
dec_req:
disabled NDF + ss + majority of D bits inverted + no majority
of I bits inverted
Notes:
1. Active offset is defined as the accepted current phase of the SPE (VC) in the
NORM_state and is undefined in the other states.
2. Enabled NDF is defined as the following bit patterns:
1001, 0001, 1101, 1011, 1000.
3. Disabled NDF is defined as the following bit patterns:
0110, 1110, 0010, 0100, 0111.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
45
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
4. The remaining six NDF codes (0000, 0011, 0101, 1010, 1100, 1111) result in
an inv_point indication.
5. The legal range of pointer values for the five supported tributary types are:
VT1.5 :
0 .. 103
VT2 :
0 .. 139
VT3 :
0 .. 211
VT6 :
0 .. 427
TU3 :
0 .. 764
6. The requirement for previous NDF_enable, inc_ind or dec_ind be more than 3
frames ago may be optionally disabled.
7. New_point is also an inv_point.
8. The requirement for 3 consecutive AIS indications may be optionally disabled.
The transitions indicated in the state diagram are defined as follows:
inc_ind/dec_ind: offset adjustment (increment or decrement indication)
3 x eq_new_point:
three consecutive equal new_point indications
NDF_enable:
single NDF_enable indication
3 x AIS_ind:
three consecutive AIS indications
8 x inv_point:
eight consecutive inv_point indications
8 x NDF_enable eight consecutive NDF_enable indications
Notes:
1. The transitions from NORM_state to NORM_state do not represent state
changes but imply offset changes.
2. 3 x eq_new_point takes precedence over other events.
3. All three offset values received in 3 x eq_new_point must be identical.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
46
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
4. "consecutive event counters" are reset to zero on a change of state.
The pointer interpreter block detects loss of pointer (LOP) in the incoming
tributaries. LOP is declared on entry to the LOP_state as a result of eight
consecutive invalid pointers or eight consecutive NDF enabled indications. LOP
is removed when the same valid pointer with normal NDF is detected for three
consecutive frames. Incoming tributary path AIS (pointer bytes set to all ones)
does not cause entry into the LOP state.
The pointer interpreter block also detects tributary path AIS in the incoming
tributaries. PAIS is declared on entry to the AIS_state after three consecutive
AIS indications. PAIS is removed when the same valid pointer with normal NDF
is detected for three consecutive frames or when a valid pointer with NDF
enabled is detected.
8.3.5 Payload Buffer
The payload buffer is a bank FIFO buffers. It is synchronous in operation and is
based on a time-sliced RAM. The three 19.44 MHz clock cycles in each 6.48
MHz period are shared between the read and write operations. The pointer
interpreter writes tributary payload data and the V5 (or TU3 J1) tag into the
payload buffer. A 16 byte FIFO buffer is provided for each of the (up to 28)
tributaries. Address information is also passed through the payload buffer to
allow FIFO fill status to be determined by the pointer generator.
8.3.6 Outgoing Timing Generator
The outgoing timing generator identifies the outgoing tributary byte being
processed. Based on the configuration of the VTPP, the outgoing timing
generator effectively constructs the STS-1 SPE, VC3, or VC4, and identifies the
bytes within these envelopes that correspond to various types of overhead and
bytes that carry specific tributaries. The identification of specific tributaries allows
the pointer generator to be time-sliced across the mix of tributaries to be sourced
in the outgoing data stream. The identification of the V1-V3 bytes of VTs, or TUs
(H1-H3 bytes of TU3s) allows the pointer generator to function.
The sequence of H4 bytes is generated by each tributary payload processor and
inserted into the outgoing administrative units. The six most significant bits of H4
are set to logic 1. The sequence of the remaining two H4 bits is determined by
the OTMF input.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
47
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
8.3.7 Pointer Generator
The pointer generator block generates the tributary pointers (V1/V2 or H1/H2 in
TU3 mode) as specified in the references. The pointer value is used to
determine the location of the tributary path overhead byte (V5 or J1 in TU3
mode) on the outgoing stream. The algorithm can be modeled by a finite state
machine. Within the pointer generator algorithm, five states are defined (as
shown in Figure 2):
NORM_state (NORM)
AIS_state (AIS)
NDF_state (NDF)
INC_state (INC)
DEC_state (DEC)
The transition from the NORM to the INC, DEC, and NDF states are initiated by
events in the payload buffer block. The transition to/from the AIS state are
controlled by the pointer interpreter block. The transitions from INC, DEC, and
NDF states to the NORM state occur autonomously with the generation of
special pointer patterns.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
48
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Figure 2
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- Pointer Generation State Diagram
PI_AIS
DEC
INC
ES
c_i
rT
de
we
nd
_lo
inc
ES
_u
pp
d
erT
_in
norm_point
NORM
ND
F_
PI_AIS
en
;le
OP
ab
_d
PI
_L
FO
PI
t
_A
on
IS
isc
PI_NORM
AIS
NDF
PI_AIS
AIS_ind
The following events, indicated in the state diagram (Figure 2), are defined:
ES_lowerT:
ES filling is below the lower threshold + previous
inc_ind,dec_ind or NDF_enable more than three frames ago.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
49
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
ES_upperT:
ES filling is above the upper threshold + previous inc_ind,
dec_ind or NDF_enable more than three frames ago.
FO_discont:
frame offset discontinuity
PI_AIS:
PI in AIS state
PI_LOP:
PI in LOP state
PI_NORM:
PI in NORM state
Notes
1. A frame offset discontinuity occurs if an incoming NDF enabled is received, or
if an elastic store overflow/underflow occurred.
2. Transition to AIS state due to PI_LOP event may be optionally disabled.
The autonomous transitions indicated in the state diagram are defined as follows:
inc_ind:
transmit the pointer with NDF disabled and inverted I bits,
transmit a stuff byte in the byte after H3, increment active
offset.
dec_ind:
transmit the pointer with NDF disabled and inverted D bits,
transmit a data byte in the H3 byte, decrement active offset.
NDF_enable:
accept new offset as active offset, transmit the pointer with
NDF enabled and new offset.
norm_point:
transmit the pointer with NDF disabled and active offset.
AIS_ind:
active offset is undefined, transmit an all-1's pointer and
payload.
Notes:
1. Active offset is defined as the phase of the SPE (VC).
2. Enabled NDF is defined as the bit pattern 1001.
3. Disabled NDF is defined as the bit pattern 0110.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
50
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
The pointer generator is a time-sliced state machine that can process up to 28
independent tributaries. The state vector is saved in RAM at the address
associated with the current tributary. The pointer generator fills the outgoing
tributary synchronous payload envelopes with bytes read from the associated
FIFO in the payload buffer for the current tributary. The pointer generator creates
pointers in the V1-V3 bytes (or H1-H3 bytes in the case of TU3s) of the outgoing
data stream. The marker that tags the V5 byte (or J1 byte in the case of a TU3)
that is passed through the payload buffer is used to align the pointer. The
outgoing timing generator directs the pointer generator to the FIFO in the
payload buffer that is associated with the tributary being processed. The pointer
generator monitors the fill levels of the payload buffers and inserts outgoing
pointer justifications as necessary to avoid FIFO spillage. Normally, the pointer
generator has a FIFO dead band of two bytes. The dead band can be collapse
to one so that any incoming pointer justifications will be reflected by a
corresponding outgoing justification with no attenuation. Signals are output by
the pointer generator that identify outgoing V5 bytes (or J1 bytes in the case of a
TU3) and the tributary synchronous payload envelopes. These simplify the
design of mappers downstream of the TUPP-PLUS. On a per tributary basis,
tributary path AIS and tributary idle (unequipped) can be inserted as controlled
by microprocessor accessible registers. The idle code is selectable globally for
the entire VC3 or TUG3 to be all-zeros or all-ones. It is also possible to force an
inverted new data flag on individual tributaries for the purpose of diagnosing
downstream pointer processors. Tributary path AIS is automatically inserted into
outgoing tributaries if the pointer interpreter detects tributary path AIS on the
corresponding incoming tributary.
8.4
Tributary Path Overhead Processor
Each tributary path overhead processor (RTOP) monitors the outgoing stream of
an associated tributary payload processor (VTPP) and processes the tributaries
within an STS-1, AU3, or TUG3. Each RTOP can be configured to process any
legal mix of VT1.5s, VT2s, VT3s, or VT6s that can be carried in an STS-1 or any
legal mix of TU11s, TU12s, TU2s, or TU3s, that can be carried in an AU3 or
TUG3. The number of tributaries managed by each RTOP ranges from 1 (when
configured to process a single TU3) to 28 (when configured to process all VT1.5s
or all TU11s).
The RTOP provides tributary performance monitoring of incoming tributaries. Bit
interleaved parity of the incoming tributaries is computed and compared with the
BIP-2 code encoded in the V5 byte of the tributary. Errors between the computed
and received values are accumulated. RTOP also accumulates far end block
error codes. Incoming path signal label is debounced and compared with the
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
51
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
provisioned value. Path signal label unstable, path signal label mismatch and
change of path signal label event are identified.
8.4.1 Clock Generator
The clock generator derives various clocks from the 19.44 MHz system clock and
distributes them to other blocks within the tributary payload processor. The
overall design is totally synchronous, with processing occurring at a 6.48 MHz
rate in each tributary path overhead processor.
8.4.2 Timing Generator
The timing generator identifies the incoming tributary being processed at any
given point in time. Based on the configuration of the RTOP (it can process
various mixes of tributary types), the incoming timing generator extracts the STS1 SPE, VC3, or a single TUG3 from a VC4, and identifies the bytes within these
envelopes that correspond to various types of overhead and those that carry
specific tributaries to be processed. The identification of specific tributaries
allows the error monitor and extract blocks to be time-sliced across the mix of
tributaries present in the incoming data stream.
8.4.3 Error Monitor
The error monitor block is a time-sliced state machine. It relies on the timing
generator block to identify the tributary being processed. The error monitor block
contains a set of 12-bit counters that are used to accumulate tributary path BIP-2
errors, and a set of 11-bit counters to accumulate far end block errors (FEBE).
The contents of the counters may be transferred to a holding RAM, and the
counters reset under microprocessor control.
Tributary path BIP-2 errors are detected by comparing the tributary path BIP-2
bits in the V5 byte extracted from the current multiframe, to the BIP-2 value
computed for the previous multiframe. BIP-2 errors may be accumulated on a
block or nibble basis as controlled by software configurable registers. Far end
block errors (FEBEs) are detected by extracting the FEBE bit from the tributary
path overhead byte (V5).
Tributary path remote defect indication (RDI) and remote failure indication (RFI)
are detected by extracting bit 8 and bit 4 respectively of the tributary path
overhead byte (V5). The RDI is recognized when bit 8 of the V5 byte is set high
for five or ten consecutive multiframes while RFI is recognized when bit 4 of V5 is
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
52
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
set high for five or ten consecutive frames. In TU3 mode, RDI is recognized
when bit 5 of the G1 byte is set high for five or ten consecutive frames. Bit 5 of
the G1 byte is similarly processed for the status of the auxiliary RDI state. The
RDI and RFI bits, and similarly bits 4 and 5 of a TU3 stream, may be treated as a
two-bit code word. A code change is only recognized when the code is
unchanged for five or ten frames.
The tributary path signal label (PSL) found in the tributary path overhead byte
(V5) is processed. (C2 in TU3 mode). An incoming PSL is accepted when it is
received unchanged for five consecutive multiframes. The accepted PSL is
compared with the associated provisioned value. The PSL match/mismatch state
is determined by the following:
Table 1
- Path Signal Label Mismatch State
Expected PSL
Accepted PSL
PSLM State
000
000
Match
000
001
Mismatch
000
PDI Code
Mismatch
000
XXX ≠ 000, 001, PDI Code
Mismatch
001
000
Mismatch
001
001
Match
001
PDI Code
Match
001
XXX ≠ 000, 001, PDI Code
Match
PDI Code
000
Mismatch
PDI Code
001
Match
PDI Code
PDI Code
Match
PDI Code
XXX ≠ 000, 001, PDI Code
Mismatch
XXX ≠ 000, 001,
PDI Code
000
Mismatch
XXX ≠ 000, 001,
PDI Code
001
Match
XXX ≠ 000, 001,
PDI Code
XXX
Match
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
53
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Expected PSL
Accepted PSL
PSLM State
XXX ≠ 000, 001,
PDI Code
YYY
Mismatch
Each time an incoming PSL differs from the one in the previous multiframe, the
PSL unstable counter is incremented. Thus, a single bit error in the PSL in a
sequence of constant PSL values will cause the counter to increment twice, once
on the errored PSL and again on the first error-free PSL. The incoming PSL is
considered unstable when the counter reaches five. The counter is cleared when
the same PSL is received for five consecutive multiframes.
8.4.4 In-band Error Report
The in-band error report block optionally modifies the G1 byte of outgoing TU3
streams or the V5 byte of outgoing non-TU3 streams to report the number of
detected BIP errors and tributary path alarms. In-band error reporting is enabled
by the IBER regisiter bits in the RTOP In-band Error Reporting Configuration
registers.
When in-band error reporting is enabled for TU3 streams, bits 1 to 4 of the G1
byte is set to reflect the count of the number of BIP-8 errors detected in the
previous frame. Bit 5 is reports the RDI status. It is set high when the tributary
path alarms named in the Tributry Remote Defect Indication Control registers is
detected and the corresponding enable register bits is also set high. Similarly, bit
6 reports the auxiliary RDI status. It is set high when the tributary path alarms
named in the Tributry Auxiliary Remote Defect Indication Control registers is
detected and the corresponding enable register bits is also set high. Bits 7 and 8
are unmodified.
When in-band error reporting is enabled for non-TU3 streams, bit 3 of the V5
byte is set high when a BIP-2 error is detected in the previous multiframe. Bit 4 is
reports the RDI status. It is set high when the tributary path alarms named in the
Tributry Remote Defect Indication Control registers is detected and the
corresponding enable register bits is also set high. Similarly, bit 8 reports the
auxiliary RDI status. It is set high when the tributary path alarms named in the
Tributry Auxiliary Remote Defect Indication Control registers is detected and the
corresponding enable register bits is also set high. Bits 1, 2, 5, 6 and 7 are
unmodified.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
54
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
8.4.5 Extract
The extract block uses timing information from the timing generator block to
extract, serialize and output the tributary path overhead bytes (V5, J2, Z6, Z7) of
all the processed tributaries on the POH output. The POHFP output is provided
to identify the most significant bit of the V5 byte of the first tributary on the POH
output. All four tributary path overhead bytes are shifted out within each payload
frame period. Therefore, each byte is shifted out more than once. The POHEN
output is used to identify fresh overhead bytes. POHEN is set high when the
tributary path overhead byte is shifted out for the first time. POHEN is set low
when the overhead byte is merely repeated. The tributary path overhead clock,
POHCK is nominally a 9.72 MHz clock.
8.5
Tributary Trace Buffer
Each tributary trace buffer (RTTB) monitors the outgoing stream of an associated
tributary payload processor (VTPP) and processes the tributaries within an STS1, AU3, or TUG3. Each RTTB can be configured to process any legal mix of
VT1.5s, VT2s, VT3s, or VT6s that can be carried in an STS-1 or any legal mix of
TU11s, TU12s, TU2s, or TU3s, that can be carried in an AU3 or TUG3. The
number of tributaries managed by each RTTB ranges from 1 (when configured to
process a single TU3) to 28 (when configured to process all VT1.5s or all
TU11s).
The RTTB extracts the tributary path trace message contained in the J2 byte (J1
byte in TU3) to a set of internal buffers. The buffers are microprocessor
accessible to allow system software to examine the messages. Another set of
buffers is provided for system software to download the expected message. The
RTTB compares the received message with the provisioned message and
reports on the state of match. The RTTB also monitors for unstable incoming
tributary path trace messages.
8.5.1 Clock Generator
The clock generator derives various clocks from the 19.44 MHz system clock and
distributes them to other blocks within the tributary trace buffer. The overall
design is totally synchronous, with processing occurring at a 6.48 MHz rate in
each tributary trace buffer.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
55
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
8.5.2 Timing Generator
The timing generator identifies the incoming tributary being processed at any
given point in time. Based on the configuration of the RTTB (it can process
various mixes of tributary types), the incoming timing generator extracts the STS1 SPE, VC3, or a single TUG3 from a VC4, and identifies the bytes within these
envelopes that correspond to various types of overhead and those that carry
specific tributaries to be processed. The identification of specific tributaries
allows the alarm monitor and extract blocks to be time-sliced across the mix of
tributaries present in the incoming data stream.
8.5.3 Extract
The extract block is a time-sliced state machine. It uses timing information from
the timing generator block to extract the tributary path trace message bytes (J2)
from all the processed tributaries in the incoming stream. Each tributary in the
incoming stream is allocated an individual receive buffer in the buffer block. The
length of the message and, consequently, the depth of the corresponding buffer
are register programmable to be 16 or 64 bytes. Bytes in the message may be
written to the corresponding buffer in a circular fashion or optionally be
synchronized to the framing pattern embedded in the message. For a 16 byte
message, the first byte is identified by a logic one in the most significant bit. For
a 64 byte message, the last two bytes are set to the ASCII characters of
carriage-return (0DH) and linefeed (0AH).
8.5.4 Alarm Monitor
The alarm monitor block is a time-sliced state machine. It relies on the timing
generator block to identify the tributary being processed. The alarm monitor
block accesses an individual capture and expected buffers in the buffer block for
each tributary in the incoming stream. It also monitors the received message for
consistency. When the identical message is received three or five times, as
controlled by the PER5 register bit, the message is accepted. This accepted
message is then compared with the expected message provision in the buffer
block. If the accepted message differs from the expected message, the trail trace
identifier mismatch (TIM) alarm is raised. TIM alarm is negated if the accepted
and expected messages match. An accepted message that contains all-zero
bytes is treated specially. If the expected messages is not also all-zeros, the TIM
alarm is not affected upon accepting of an all-zero message. If the expected
message is all-zeros, accepting an all-zeros message would negate TIM.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
56
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
The alarm monitor block also monitors the incoming messages for stability. Two
algorithms are provided. In the first algorithm, each time the current incoming
message differs from the previous message, the corresponding unstable counter
is incremented by one. Thus, a single bit error in a message of a sequence of
constant messages will cause the counter to increment twice, once on the
corrupted message, and again on the first error free message. A trail trace
identifier unstable (TIU) alarm is raised when the counter exceeds the register
programmable threshold. The counter is cleared and TIU negated when a set of
identical messages is received and becomes the accepted message. In the
second algorithm, when the current incoming message differs from the previous
message, the corresponding counter starts incrementing once per message. A
trail trace identifier unstable (TIU) alarm is raised when the counter exceeds the
register programmable threshold. The counter is cleared and TIU negated when
a set of identical messages is received and becomes the accepted message.
8.5.5 Buffer
The buffer block contains two pages of memory, one page for capturing the
receive tributary path trace messages and the other for storing the expected
messages. Each tributary in the incoming stream is allocated a range of
addresses using high order interleaving keyed on the tributary group number and
the tributary number within the group. At the J2 byte (J1 byte in TU3 mode) of
each tributary, the receive and expected pages are read. The data from the
incoming stream, the receive page and the expected page are supplied to the
alarm monitor block for determination of trace identifier mismatch (TIM) and trace
identifier unstable (TIU) alarms. At the end of the cycle, the incoming data is
written to the receive page. The buffer block also contains an arbiter to allow
access to the receive and expected pages by the microprocessor when neither
the extract nor alarm monitor block requires access.
8.6
JTAG Test Access Port
The JTAG Test Access Port block provides JTAG support for boundary scan. The
standard JTAG EXTEST, SAMPLE, BYPASS, IDCODE and STCTEST
instructions are supported. The TUPP-PLUS identification code is 053620CD
hexadecimal.
8.7
Microprocessor Interface
The microprocessor interface block provides normal and test mode registers, and
the logic required to connect to the microprocessor interface. The normal mode
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
57
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
registers are required for normal operation, and test mode registers are used to
enhance the testability of the TUPP-PLUS. Tributary based normal mode
registers are arranged in order of transmission; TU #1 in TUG2 #1 of STS-1 #1 is
the first tributary transmitted, while TU #4 in TUG2 #7 of STS-1 #3 is the last.
The register set is accessed as follows:
8.8
Register Memory Map
Address
Register
00H
TUPP-PLUS Master Incoming Configuration
01H
TUPP-PLUS Master Outgoing Configuration
02H
Input Signal Activity Monitor, Accumulation Trigger
03H
TUPP-PLUS Master Reset and Identity
04H
VTPP #1 Configuration
05H
VTPP #2 Configuration
06H
VTPP #3 Configuration
07H
Tributary Payload Processor and LOM Interrupt Enable
08H
Tributary Payload Processor Interrupt and LOM Status
09H
Parity Error and LOM Interrupt
0AH
RTOP and RTTB Interrupt Enable
0BH
RTOP and RTTB Interrupt Status
0CH
RTOP #1 Configuration
0DH
RTOP #2 Configuration
0EH
RTOP #3 Configuration
0FH
Reserved
10H
Tributary Alarm AIS Control
11H
Tributary Remote Defect Indication Control
12H
Tributary Auxiliary Remote Defect Indication Control
13H
Tributary Path Defect Indication Control
14H-1FH
Reserved
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
58
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Address
Register
20H
VTPP #1, TU3 or TU #1 in TUG2 #1, Configuration and
Status
21H
VTPP #1, TU #1 in TUG2 #2, Configuration and Status
22H
VTPP #1, TU #1 in TUG2 #3, Configuration and Status
23H
VTPP #1, TU #1 in TUG2 #4, Configuration and Status
24H
VTPP #1, TU #1 in TUG2 #5, Configuration and Status
25H
VTPP #1, TU #1 in TUG2 #6, Configuration and Status
26H
VTPP #1, TU #1 in TUG2 #7, Configuration and Status
27H
VTPP #1, TU3 or TU #1 in TUG2 #1 to TUG2 #7, LOP
Interrupt
28H-2EH
VTPP #1, TU #2 in TUG2 #1 to TUG2 #7, Configuration
and Status
2FH
VTPP #1, TU #2 in TUG2 #1 to TUG2 #7, LOP Interrupt
30H-36H
VTPP #1, TU #3 in TUG2 #1 to TUG2 #7, Configuration
and Status
37H
VTPP #1, TU #3 in TUG2 #1 to TUG2 #7, LOP Interrupt
38H-3EH
VTPP #1, TU #4 in TUG2 #1 to TUG2 #7, Configuration
and Status
3FH
VTPP #1, TU #4 in TUG2 #1 to TUG2 #7, LOP Interrupt
40H-5FH
VTPP #2 Configuration and Status, and LOP Interrupt
Registers
60H-7FH
VTPP #3 Configuration and Status, and LOP Interrupt
Registers
80H-9FH
Reserved
A0H
VTPP #1, TU3, or TU #1 in TUG2 #1, Alarm Status
A1H
VTPP #1, TU #1 in TUG2 #2, Alarm Status
A2H
VTPP #1, TU #1 in TUG2 #3, Alarm Status
A3H
VTPP #1, TU #1 in TUG2 #4, Alarm Status
A4H
VTPP #1, TU #1 in TUG2 #5, Alarm Status
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
59
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Address
Register
A5H
VTPP #1, TU #1 in TUG2 #6, Alarm Status
A6H
VTPP #1, TU #1 in TUG2 #7, Alarm Status
A7H
VTPP #1, TU3 or TU #1 in TUG2 #1 to TUG2 #7, AIS
Interrupt
A8H-AEH
VTPP #1, TU #2 in TUG2 #1 to TUG2 #7, Alarm Status
AFH
VTPP #1, TU #2 in TUG2 #1 to TUG2 #7, AIS Interrupt
B0H-B6H
VTPP #1, TU #3 in TUG2 #1 to TUG2 #7, Alarm Status
B7H
VTPP #1, TU #3 in TUG2 #1 to TUG2 #7, AIS Interrupt
B8H-BEH
VTPP #1, TU #4 in TUG2 #1 to TUG2 #7, Alarm Status
BFH
VTPP #1, TU #4 in TUG2 #1 to TUG2 #7, AIS Interrupt
C0H-DFH
VTPP #2 Alarm Status, and AIS Interrupt Registers
E0H-FFH
VTPP #3 Alarm Status, and AIS Interrupt Registers
100H
RTOP #1, TU3 or TU #1 in TUG2 #1, Configuration
101H
RTOP #1, TU3 or TU #1 in TUG2 #1, Config. and Alarm
Status
102H
RTOP #1, TU3 or TU #1 in TUG2 #1, Expected Path Signal
Label
103H
RTOP #1, TU3 or TU #1 in TUG2 #1, Accepted Path Signal
Label
104H
RTOP #1, TU3 or TU #1 in TUG2 #1, BIP Count LSB
105H
RTOP #1, TU3 or TU #1 in TUG2 #1, BIP Count MSB
106H
RTOP #1, TU3 or TU #1 in TUG2 #1, FEBE Count LSB
107H
RTOP #1, TU3 or TU #1 in TUG2 #1, FEBE Count MSB
108H-10FH
RTOP #1, TU #1 in TUG2 #2, Configuration and Status
Registers
110H-117H
RTOP #1, TU #1 in TUG2 #3, Configuration and Status
Registers
118H-11FH
RTOP #1, TU #1 in TUG2 #4, Configuration and Status
Registers
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
60
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Address
Register
120H-127H
RTOP #1, TU #1 in TUG2 #5, Configuration and Status
Registers
128H-12FH
RTOP #1, TU #1 in TUG2 #6, Configuration and Status
Registers
130H-137H
RTOP #1, TU #1 in TUG2 #7, Configuration and Status
Registers
138H
RTOP #1, TU3 or TU #1 in TUG2 #1 to TUG2 #7, COPSL
Interrupt
139H
RTOP #1, TU3 or TU #1 in TUG2 #1 to TUG2 #7, PSLM
Interrupt
13AH
RTOP #1, TU3 or TU #1 in TUG2 #1 to TUG2 #7, PSLU
Interrupt
13BH
RTOP #1, TU3 or TU #1 in TUG2 #1 to TUG2 #7, RDI
Interrupt
13CH
RTOP #1, TU3 or TU #1 in TUG2 #1 to TUG2 #7, RFI
Interrupt
13DH
RTOP #1, TU #1 In Band Error Reporting Configuration
13EH
RTOP #1, TU #1 Controllable Output Configuration
13FH
Reserved
140H-147H
RTOP #1, TU #2 in TUG2 #1, Configuration and Status
Registers
148H-14FH
RTOP #1, TU #2 in TUG2 #2, Configuration and Status
Registers
150H-157H
RTOP #1, TU #2 in TUG2 #3, Configuration and Status
Registers
158H-15FH
RTOP #1, TU #2 in TUG2 #4, Configuration and Status
Registers
160H-167H
RTOP #1, TU #2 in TUG2 #5, Configuration and Status
Registers
168H-16FH
RTOP #1, TU #2 in TUG2 #6, Configuration and Status
Registers
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
61
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Address
Register
170H-177H
RTOP #1, TU #2 in TUG2 #7, Configuration and Status
Registers
178H
RTOP #1, TU #2 in TUG2 #1 to TUG2 #7, COPSL Interrupt
179H
RTOP #1, TU #2 in TUG2 #1 to TUG2 #7, PSLM Interrupt
17AH
RTOP #1, TU #2 in TUG2 #1 to TUG2 #7, PSLU Interrupt
17BH
RTOP #1, TU #2 in TUG2 #1 to TUG2 #7, RDI Interrupt
17CH
RTOP #1, TU #2 in TUG2 #1 to TUG2 #7, RFI Interrupt
17DH
RTOP #1, TU #2 In Band Error Reporting Configuration
17EH
RTOP #1, TU #2 Configurable Output Control
17FH
Reserved
180H-187H
RTOP #1, TU #3 in TUG2 #1, Configuration and Status
Registers
188H-18FH
RTOP #1, TU #3 in TUG2 #2, Configuration and Status
Registers
190H-197H
RTOP #1, TU #3 in TUG2 #3, Configuration and Status
Registers
198H-19FH
RTOP #1, TU #3 in TUG2 #4, Configuration and Status
Registers
1A0H-1A7H
RTOP #1, TU #3 in TUG2 #5, Configuration and Status
Registers
1A8H-1AFH
RTOP #1, TU #3 in TUG2 #6, Configuration and Status
Registers
1B0H-1B7H
RTOP #1, TU #3 in TUG2 #7, Configuration and Status
Registers
1B8H
RTOP #1, TU #3 in TUG2 #1 to TUG2 #7, COPSL Interrupt
1B9H
RTOP #1, TU #3 in TUG2 #1 to TUG2 #7, PSLM Interrupt
1BAH
RTOP #1, TU #3 in TUG2 #1 to TUG2 #7, PSLU Interrupt
1BBH
RTOP #1, TU #3 in TUG2 #1 to TUG2 #7, RDI Interrupt
1BCH
RTOP #1, TU #3 in TUG2 #1 to TUG2 #7, RFI Interrupt
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
62
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Address
Register
1BDH
RTOP #1, TU #3 In Band Error Reporting Configuration
1BEH
RTOP #1, TU #3 Configurable Output Control
1BFH
Reserved
1C0H-1C7H
RTOP #1, TU #4 in TUG2 #1, Configuration and Status
Registers
1C8H-1CFH
RTOP #1, TU #4 in TUG2 #2, Configuration and Status
Registers
1D0H-1D7H
RTOP #1, TU #4 in TUG2 #3, Configuration and Status
Registers
1D8H-1DFH
RTOP #1, TU #4 in TUG2 #4, Configuration and Status
Registers
1E0H-1E7H
RTOP #1, TU #4 in TUG2 #5, Configuration and Status
Registers
1E8H-1EFH
RTOP #1, TU #4 in TUG2 #6, Configuration and Status
Registers
1F0H-1F7H
RTOP #1, TU #4 in TUG2 #7, Configuration and Status
Registers
1F8H
RTOP #1, TU #4 in TUG2 #1 to TUG2 #7, COPSL Interrupt
1F9H
RTOP #1, TU #4 in TUG2 #1 to TUG2 #7, PSLM Interrupt
1FAH
RTOP #1, TU #4 in TUG2 #1 to TUG2 #7, PSLU Interrupt
1FBH
RTOP #1, TU #4 in TUG2 #1 to TUG2 #7, RDI Interrupt
1FCH
RTOP #1, TU #4 in TUG2 #1 to TUG2 #7, RFI Interrupt
1FDH
RTOP #1, TU #4 In Band Error Reporting Configuration
1FEH
RTOP #1, TU #4 Configurable Output Control
1FFH
RTOP #1 Status
200H-2FFH
RTOP #2 Registers
300H-3FFH
RTOP #3 Registers
400H
RTTB #1, TU3 or TU #1 in TUG2 #1 Configuration and
Status
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
63
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Address
Register
401H
RTTB #1, TU #1 in TUG2 #2 Configuration and Status
402H
RTTB #1, TU #1 in TUG2 #3 Configuration and Status
403H
RTTB #1, TU #1 in TUG2 #4 Configuration and Status
404H
RTTB #1, TU #1 in TUG2 #5 Configuration and Status
405H
RTTB #1, TU #1 in TUG2 #6 Configuration and Status
406H
RTTB #1, TU #1 in TUG2 #7 Configuration and Status
407H
Reserved
408H-40EH
RTTB #1, TU #2 in TUG2 #1 to TUG2 #7, Configuration and
Status
40FH
Reserved
410H-416H
RTTB #1, TU #3 in TUG2 #1 to TUG2 #7, Configuration and
Status
417H
Reserved
418H-41EH
RTTB #1, TU #4 in TUG2 #1 to TUG2 #7, Configuration and
Status
41FH
Reserved
420H
RTTB #1, TU3 or TU #1 in TUG2 #1 to TUG2 #7, TIM
Interrupt
421H
RTTB #1, TU #2 in TUG2 #1 to TUG2 #7, TIM Interrupt
422H
RTTB #1, TU #3 in TUG2 #1 to TUG2 #7, TIM Interrupt
423H
RTTB #1, TU #4 in TUG2 #1 to TUG2 #7, TIM Interrupt
424H
RTTB #1, TU3 or TU #1 in TUG2 #1 to TUG2 #7, TIU
Interrupt
425H
RTTB #1, TU #2 in TUG2 #1 to TUG2 #7, TIU Interrupt
426H
RTTB #1, TU #3 in TUG2 #1 to TUG2 #7, TIU Interrupt
427H
RTTB #1, TU #4 in TUG2 #1 to TUG2 #7, TIU Interrupt
428H
RTTB #1, TIU Threshold
429H
RTTB #1, Indirect Tributary Select
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
64
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Address
Register
42AH
RTTB #1, Indirect Buffer Address
42BH
RTTB #1, Indirect Data
42CH-43FH
Reserved
440H-47FH
RTTB #2 Registers
480H-4BFH
RTTB #3 Registers
4C0H-7FFH
Reserved
800H
Master Test
801H-FFFH
Reserved for Test
For all register accesses, CSB must be low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
65
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
9
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
NORMAL MODE REGISTER DESCRIPTION
Normal mode registers are used to configure and monitor the operation of the
TUPP-PLUS. Normal mode registers (as opposed to test mode registers) are
selected when A[11] is low.
Notes on Normal Mode Register Bits:
1. Writing values into unused register bits has no effect. However, to ensure
software compatibility with future, feature-enhanced versions of the product,
unused register bits must be written with logic 0. Reading back unused bits
can produce either a logic 1 or a logic 0; hence unused register bits should be
masked off by software when read.
2. All configuration bits that can be written into can also be read back. This
allows the processor controlling the TUPP-PLUS to determine the
programming state of the block.
3. Writable normal mode register bits are cleared to logic 0 upon reset unless
otherwise noted.
4. Writing into read-only normal mode register bit locations does not affect
TUPP-PLUS operation unless otherwise noted.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
66
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
9.1
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Master Registers
Register 00H: Master Incoming Configuration
Bit
Type
Function
Default
Bit 7
R/W
IPE
0
Bit 6
R/W
LOPAIS
0
Bit 5
R/W
INCIPL
0
Bit 4
R/W
INCIC1J1
0
Bit 3
R/W
IOP
0
Bit 2
R/W
ITMFH4
0
Bit 1
R/W
ITMFEN
0
Bit 0
R/W
ICONCAT
0
This register configures the TUPP-PLUS functionality that are related to the
incoming data stream.
ICONCAT:
When set high, the ICONCAT bit configures the incoming section of the
TUPP-PLUS to operate in AU4 mode. When the ICONCAT bit is set low, the
incoming section operates in AU3 mode (or equivalently, STS-1 mode).
ITMFEN:
When set high, the ITMFEN bit enables the TUPP-PLUS to use the ITMF
input signal to locate tributary multiframe boundaries. The H4 bytes in the
incoming data stream are ignored. When ITMFEN is set low, the H4 bytes
are used to locate the boundaries, and the ITMF signal is ignored.
ITMFH4:
The ITMFH4 bit selects the location of the ITMF in the tributary multiframe.
When ITMFH4 is set high, ITMF is pulsed high to mark the H4 byte which
indicates that the next AU3/4 or STS-1 frame is the first frame of the tributary
multiframe. When ITMFH4 is set low, ITMF marks the third byte after J1.
ITMFH4 is ignored if ITMF is disabled by setting the ITMFEN bit low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
67
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
IOP:
The IOP bit controls the expected parity on the incoming parity signal IDP.
When IOP is set high, the parity of the parity signal set, together with IDP is
expected to be odd. When IOP is set low, the expected parity is even.
Membership of the parity signal set always includes ID[7:0], and may include
input signals IC1J1 and IPL as controlled by the INCIC1J1 and INCIPL bits,
respectively.
INCIC1J1:
The INCIC1J1 bit controls whether the IC1J1 input signal participates in the
incoming parity calculations. When INCIC1J1 is set high, the parity signal set
includes the IC1J1 input. When INCIC1J1 is set low, parity is calculated
without regard to the state of IC1J1. Selection of odd or even parity is
controlled by the IOP bit.
INCIPL:
The INCIPL bit controls the whether the IPL input signal participates in the
incoming parity calculations. When INCIPL is set high, the parity signal set
includes the IPL input. When INCIPL is set low, parity is calculated without
regard to the state of IPL. Selection of odd or even parity is controlled by the
IOP bit.
LOPAIS:
The LOPAIS bit is an active high AIS insertion enable. When LOPAIS is set
high, AIS is automatically generated on the outgoing data stream for all
tributaries that are in loss of pointer state. When LOPAIS is set low, the
generation of AIS on the outgoing data stream is inhibited. This bit is logically
OR'ed with the bit of the same name in Tributary Alarm AIS Control register.
IPE:
The IPE bit is an active high interrupt enable. When IPE is set high, the
occurrence of a parity error on the incoming parity signal set will cause an
interrupt to be asserted on the interrupt (INTB) output. When IPE is set low,
incoming parity errors will not cause an interrupt.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
68
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 01H: Master Outgoing Configuration
Bit
Type
Function
Default
Bit 7
R/W
LOCK0
0
Unused
X
Bit 6
Bit 5
R/W
POHPT
0
Bit 4
R/W
LV1EN
0
Bit 3
R/W
OOP
0
Bit 2
R/W
OTMFH4
0
Bit 1
R/W
OJ1EN
0
Bit 0
R/W
OCONCAT
0
This register configures the TUPP-PLUS functionality that are related to the
outgoing data stream.
OCONCAT:
When set high, the OCONCAT bit configures the outgoing section of the
TUPP-PLUS to operate in AU4 mode. When the OCONCAT bit is set low, the
outgoing section operates in AU3 mode (or equivalently, STS-1 mode).
OJ1EN:
The OJ1EN bit selects the operation of the outgoing data stream to be in
floating or locked mode. When OJ1EN is set high, TUPP-PLUS output bus to
operate in floating mode where the OC1J1 signal marks the first C1 byte and
the J1 bytes in the outgoing data stream, OD[7:0]. The OPL input is used to
distinguish between bytes in the transport overhead and the payload
envelope, and consequently C1 and J1. Only one J1 byte, and one VC or
concatenated SPE, are expected to be marked when configured for AU4
mode (OCONCAT set high). Outputs LC1J1V1 and LPL are held low in
floating mode.
When the OJ1EN bit is low, the TUPP-PLUS output bus operates in locked
mode where the OC1J1 signal marks the first C1 byte only in the outgoing
data stream, OD[7:0]. In this mode, the OPL input must be logic zero for the
C1 byte. The TUPP-PLUS defaults to fixed output timing where the J1 bytes
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
69
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
of the STS-1, AU3 or AU4 synchronous payload envelopes can be controlled
by the LOCK0 bit to immediately follow the C1 bytes or the H3 bytes.
In either floating or locked mode, the OTMF input is used to establish the
transmit tributary multiframe boundaries on the outgoing data stream OD[7:0].
OTMFH4:
The OTMFH4 bit selects the location of the OTMF in the tributary multiframe.
When OTMFH4 is set high, OTMF is pulsed high to mark the H4 byte which
indicates that the next AU3/4 or STS-1 frame is the first frame of the tributary
multiframe. When OTMFH4 is set low, OTMF marks the third byte after J1.
OOP:
The OOP bit controls the parity placed on the outgoing parity signal ODP.
When OOP is set low, the parity of outgoing data stream OD[7:0], together
with ODP is even. When OOP is set high, the parity is odd.
LV1EN:
The LV1EN bit controls the identification of the third byte after J1 in the V1
frame in locked mode (OJ1EN set low). When LV1EN is set low, the LC1J1V1
output only indicates the C1 and J1 bytes. The third byte after J1 is not
indicated. When LV1EN is set high, the LC1J1V1 output indicates the C1, J1
and the third byte after J1. LV1EN is ignored in floating mode (OJ1EN set
high).
POHPT:
The POHPT bit controls the data of the path overhead column on the
outgoing STS-1 (AU3, AU4) streams. When POHPT is set low, the outgoing
POH columns (except the H4 byte) are set to all-zeros. When POHPT is set
high, the POH column (except the H4 byte) of the incoming stream is
transferred to the outgoing stream. A two frame elastic store buffer is
provided to absorb phase variations between the incoming and outgoing
frames.
LOCK0:
The LOCK0 bit controls the payload offset of the outgoing data stream in
locked mode (OJ1EN set low). When LOCK0 is set high, the J1 byte in the
outgoing data stream is forced to the byte immediately following the H3 bytes
(pointer offset zero). When LOCK0 is set low, the J1 byte is force to the byte
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
70
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
immediately following the C1 bytes (pointer offset 522). LOCK0 is ignored in
floating mode (OJ1EN set high).
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
71
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 02H: Input Signal Activity Monitor, Accumulation Trigger
Bit
Type
Function
Default
Bit 7
R
OTMFA
X
Bit 6
R
OPLA
X
Bit 5
R
OC1J1A
X
Bit 4
R
IDA
X
Bit 3
R
ITMFA
X
Bit 2
R
IPLA
X
Bit 1
R
IC1J1A
X
Bit 0
R
SCLKA
X
This register provides activity monitoring on major TUPP-PLUS inputs. When a
monitored input makes a low to high transition, the corresponding register bit is
set high. The bit will remain high until this register is read, at which point, all the
bits in this register are cleared. A lack of transitions is indicated by the
corresponding register bit reading low. This register should be read periodically
to detect for stuck at conditions.
Writing to this register delimits the accumulation intervals in the RTOP
accumulation registers. Counts accumulated in those registers are transferred to
holding registers where they can be read. The counters themselves are then
cleared to begin accumulating events for a new accumulation interval. To prevent
loss of data, accumulation intervals must be 0.5 second or shorter. The bits in
this register are not affected by write accesses.
SCLKA:
The SCLK active (SCLKA) bit monitors for low to high transitions on the SCLK
input. SCLKA is set high on a rising edge of SCLK, and is set low when this
register is read.
IC1J1A:
The IC1J1 active (IC1J1A) bit monitors for low to high transitions on the IC1J1
input. IC1J1A is set high on a rising edge of IC1J1, and is set low when this
register is read.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
72
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
IPLA:
The IPL active (IPLA) bit monitors for low to high transitions on the IPL input.
IPLA is set high on a rising edge of IPL, and is set low when this register is
read.
ITMFA:
The ITMF active (ITMFA) bit monitors for low to high transitions on the ITMF
input. ITMFA is set high on a rising edge of ITMF, and is set low when this
register is read.
IDA:
The ID bus active (IDA) bit monitors for low to high transitions on the ID[7:0]
inputs. IDA is set high when rising edges have been observed on all the
signals on the ID[7:0] bus, and is set low when this register is read.
OC1J1A:
The OC1J1 active (OC1J1A) bit monitors for low to high transitions on the
OC1J1 input. OC1J1A is set high on a rising edge of OC1J1, and is set low
when this register is read.
OPLA:
The OPL active (OPLA) bit monitors for low to high transitions on the OPL
input. OPLA is set high on a rising edge of OPL, and is set low when this
register is read.
OTMFA:
The OTMF active (OTMFA) bit monitors for low to high transitions on the
OTMF input. OTMFA is set high on a rising edge of OTMF, and is set low
when this register is read.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
73
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 03H: Master Reset and Identity
Bit
Type
Function
Default
Bit 7
R/W
RESET
0
Bit 6
R
TYPE
1
Bit 5
R
ID[5]
0
Bit 4
R
ID[4]
0
Bit 3
R
ID[3]
0
Bit 2
R
ID[2]
0
Bit 1
R
ID[1]
0
Bit 0
R
ID[0]
1
This register allows the revision of the TUPP-PLUS to be read by software
permitting graceful migration to support for newer, feature enhanced versions of
the TUPP-PLUS, should revision of the TUPP-PLUS occur. It also provides
software reset capability.
ID[5:0]:
The ID bits can be read to provide a binary TUPP-PLUS revision number.
TYPE:
The TYPE bit can be read to distinguish between the TUPP-PLUS and the
TUPP devices. The TYPE bit is set high in the TUPP-PLUS and set low in the
TUPP device.
RESET:
The RESET bit allows the TUPP-PLUS to be reset under software control. If
the RESET bit is a logic 1, the entire TUPP-PLUS is held in reset. This bit is
not self-clearing. Therefore, a logic 0 must be written to bring the
TUPP-PLUS out of reset. Holding the TUPP-PLUS in a reset state places it
into a low power, stand-by mode. A hardware reset clears the RESET bit,
thus negating the software reset. Otherwise the effect of a software reset is
equivalent to that of a hardware reset.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
74
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 04H: VTPP #1 Configuration
Bit
Type
Function
Default
Bit 7
R/W
TUGEN
0
Bit 6
R/W
SOS
0
Bit 5
R/W
MONIS
0
Bit 4
R/W
ICODE
0
Bit 3
R/W
NOFILT
0
Bit 2
R/W
TU3
0
Bit 1
R/W
ITUG3
0
Bit 0
R/W
OTUG3
0
This register is used to enable the processing of STS-1 #1 (TUG3 #1) and
configure the major operational modes of VTPP #1.
OTUG3:
When set high, the OTUG3 bit configures the tributary payload processor to
process a TU3 or TUG2s that have been mapped into a TUG3 in the outgoing
data stream. When low, the tributary payload processor defaults to
processing TUG2s that have been mapped into a VC3, or equivalently, VT
groups that have been mapped into an STS-1.
ITUG3:
When set high, the ITUG3 bit configures the tributary payload processor to
process a TU3 or TUG2s that have been mapped into a TUG3 in the incoming
data stream. When low, the tributary payload processor defaults to
processing TUG2s that have been mapped into a VC3, or equivalently, VT
groups that have been mapped into an STS-1.
TU3:
When set high, the TU3 bit configures the tributary payload processor to
process a single TU3 that has been mapped into a TUG3. The programming
of the ITUG3 and OTUG3 bits are ignored. Both the incoming and outgoing
streams are affected simultaneously by the TU3 bit. When in TU3 mode,
registers 20H and 27H reflect TU3 status and configuration, all other registers
relating to TUG2s and the tributaries within TUG2s are disabled; data written
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
75
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
is ignored, data read is invalid. When not in TU3 mode, register 20H reflects
status and configuration of TUG2 #1, TU #1 and register 27H reflect LOP
interrupt status of TU #1 in all seven TUG #2s. When changing the value of
the TU3 bit, tributary processing must be disabled (TUGEN must have a value
of logic zero).
NOFILT:
The NOFILT bit controls the processing of incoming tributary pointers. When
a logic 0 is written to this location, illegal variations from normal tributary
pointer value (i.e. changes which do not correspond to pointer justification
events, and are not accompanied by a new data flag) are ignored unless a
consistent new value is received three times consecutively. When a logic 1 is
written to this location, variations take effect immediately and are passed
through the payload buffer unfiltered.
ICODE:
The ICODE bit controls the value inserted into tributary bytes when idle
insertion is enabled. When a logic 0 is written to this location, the idle code is
chosen to be all zeros. Setting ICODE to 1 sets the idle code to all ones. Idle
insertion only affects the tributary payload bytes which are overwritten with
the selected idle pattern. The outgoing pointer remains a function of the
incoming pointer and the relative multiframe alignment of the incoming and
outgoing streams. ICODE has no effect on pointer processing. In TU3 mode,
ICODE must be set to 0 for the C2 byte to indicate unequipped.
MONIS:
The MONIS bit controls the source of pointer justification interrupts. When
MONIS is set high, the incoming stream is monitored for tributary pointer
justification events. When MONIS is set low, the outgoing stream is
monitored for pointer justification events. Interrupts can be optionally
generated upon a pointer justification event in the monitored stream.
SOS:
The SOS bit controls the spacing between consecutive pointer justification
events on the incoming stream. When SOS is set high, the definition of
inc_ind and dec_ind indications includes the requirement that active offset
changes have occurred at least three frames ago. When SOS is set low,
pointer justification indications in the incoming stream are followed without
regard to the proximity of previous active offset change.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
76
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
TUGEN:
When set high, the TUGEN bit enables the processing of tributaries in
STS-1 #1 (TUG3 #1). When TUGEN is low, VTPP #1, RTOP #1 and RTTB #1
are held in a low power, reset state. The data in STS-1 #1 (TUG3 #1) is retransmitted unchanged on the outgoing data stream. The amount of delay
from the incoming to the outgoing data stream is a function of the separation
between the IC1J1 and OC1J1 inputs. See the bypass functional timing
diagram for details. When TUGEN is toggled low, the VTTP #1, RTOP #1,
and RTTB #1 registers with addresses 0x20H and higher are reset to their
default states.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
77
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 05H: VTPP #2 Configuration
Bit
Type
Function
Default
Bit 7
R/W
TUGEN
0
Bit 6
R/W
SOS
0
Bit 5
R/W
MONIS
0
Bit 4
R/W
ICODE
0
Bit 3
R/W
NOFILT
0
Bit 2
R/W
TU3
0
Bit 1
R/W
ITUG3
0
Bit 0
R/W
OTUG3
0
This register is used to enable the processing of STS-1 #2 (TUG3 #2) and
configure the major operational modes of VTPP #2.
OTUG3:
When set high, the OTUG3 bit configures the tributary payload processor to
process a TU3 or TUG2s that have been mapped into a TUG3 in the outgoing
data stream. When low, the tributary payload processor defaults to
processing TUG2s that have been mapped into a VC3, or equivalently, VT
groups that have been mapped into an STS-1.
ITUG3:
When set high, the ITUG3 bit configures the tributary payload processor to
process a TU3 or TUG2s that have been mapped into a TUG3 in the incoming
data stream. When low, the tributary payload processor defaults to
processing TUG2s that have been mapped into a VC3, or equivalently, VT
groups that have been mapped into an STS-1.
TU3:
When set high, the TU3 bit configures the tributary payload processor to
process a single TU3 that has been mapped into a TUG3. The programming
of the ITUG3 and OTUG3 bits are ignored. Both the incoming and outgoing
streams are affected simultaneously by the TU3 bit. When in TU3 mode,
registers 40H and 47H reflect TU3 status and configuration, all other registers
relating to TUG2s and the tributaries within TUG2s are disabled; data written
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
78
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
is ignored, and read data is invalid. When not in TU3 mode, register 40H
reflects status and configuration of TUG2 #1, TU #1 and register 47H reflect
LOP interrupt status of TU #1 in all seven TUG #2s. When changing the
value of the TU3 bit, tributary processing must be disabled (TUGEN must
have a value of logic zero).
NOFILT:
The NOFILT bit controls the processing of incoming tributary pointers. When
a logic 0 is written to this location, illegal variations from normal tributary
pointer value (i.e. changes which do not correspond to pointer justification
events, and are not accompanied by a new data flag) are ignored unless a
consistent new value is received three times consecutively. When a logic 1 is
written to this location, variations take effect immediately and are passed
through the payload buffer unfiltered.
ICODE:
The ICODE bit controls the value inserted into tributary bytes when idle
insertion is enabled. When a logic 0 is written to this location, the idle code is
chosen to be all zeros. Setting ICODE to 1 sets the idle code to all ones. Idle
insertion only affects the tributary payload bytes which are overwritten with
the selected idle pattern. The outgoing pointer remains a function of the
incoming pointer and the relative multiframe alignment of the incoming and
outgoing streams. ICODE has no effect on pointer processing. In TU3 mode,
ICODE must be set to 0 for the C2 byte to indicate unequipped.
MONIS:
The MONIS bit controls the source of pointer justification interrupts. When
MONIS is set high, the incoming stream is monitored for tributary pointer
justification events. When MONIS is set low, the outgoing stream is
monitored for pointer justification events. Interrupts can be optionally
generated upon a pointer justification event in the monitored stream.
SOS:
The SOS bit controls the spacing between consecutive pointer justification
events on the incoming stream. When SOS is set high, the definition of
inc_ind and dec_ind indications includes the requirement that active offset
changes have occurred at least three frames ago. When SOS is set low,
pointer justification indications in the incoming stream are followed without
regard to the proximity of previous active offset change.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
79
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
TUGEN:
When set high, the TUGEN bit enables the processing of tributaries in
STS-1 #2 (TUG3 #2). When TUGEN is low, VTPP #2, RTOP #2 and RTTB #2
are held in a low power, reset state. The data in STS-1 #2 (TUG3 #2) is retransmitted unchanged on the outgoing data stream. The amount of delay
from the incoming to the outgoing data stream is a function of the separation
between the IC1J1 and OC1J1 inputs. See the bypass functional timing
diagram for details. When TUGEN is toggled low, the VTTP #2, RTOP #2,
and RTTB #2 registers with addresses 0x40H and higher are reset to their
default states.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
80
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 06H: VTPP #3 Configuration
Bit
Type
Function
Default
Bit 7
R/W
TUGEN
0
Bit 6
R/W
SOS
0
Bit 5
R/W
MONIS
0
Bit 4
R/W
ICODE
0
Bit 3
R/W
NOFILT
0
Bit 2
R/W
TU3
0
Bit 1
R/W
ITUG3
0
Bit 0
R/W
OTUG3
0
This register is used to enable the processing of STS-1 #3 (TUG3 #3) and
configure the major operational modes of VTPP #1.
OTUG3:
When set high, the OTUG3 bit configures the tributary payload processor to
process a TU3 or TUG2s that have been mapped into a TUG3 in the outgoing
data stream. When low, the tributary payload processor defaults to
processing TUG2s that have been mapped into a VC3, or equivalently, VT
groups that have been mapped into an STS-1.
ITUG3:
When set high, the ITUG3 bit configures the tributary payload processor to
process a TU3 or TUG2s that have been mapped into a TUG3 in the incoming
data stream. When low, the tributary payload processor defaults to
processing TUG2s that have been mapped into a VC3, or equivalently, VT
groups that have been mapped into an STS-1.
TU3:
When set high, the TU3 bit configures the tributary payload processor to
process a single TU3 that has been mapped into a TUG3. The programming
of the ITUG3 and OTUG3 bits are ignored. Both the incoming and outgoing
streams are affected simultaneously by the TU3 bit. When in TU3 mode,
registers 60H and 67H reflect TU3 status and configuration, all other registers
relating to TUG2s and the tributaries within TUG2s are disabled; data written
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
81
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
is ignored and read data is invalid. When not in TU3 mode, register 60H
reflects status and configuration of TUG2 #1, TU #1 and register 67H reflect
LOP interrupt status of TU #1 in all seven TUG #2s. When changing the
value of the TU3 bit, tributary processing must be disabled (TUGEN must
have a value of logic zero).
NOFILT:
The NOFILT bit controls the processing of incoming tributary pointers. When
a logic 0 is written to this location, illegal variations from normal tributary
pointer value (i.e. changes which do not correspond to pointer justification
events, and are not accompanied by a new data flag) are ignored unless a
consistent new value is received three times consecutively. When a logic 1 is
written to this location, variations take effect immediately and are passed
through the payload buffer unfiltered.
ICODE:
The ICODE bit controls the value inserted into tributary bytes when idle
insertion is enabled. When a logic 0 is written to this location, the idle code is
chosen to be all zeros. Setting ICODE to 1 sets the idle code to all ones. Idle
insertion only affects the tributary payload bytes which are overwritten with
the selected idle pattern. The outgoing pointer remains a function of the
incoming pointer and the relative multiframe alignment of the incoming and
outgoing streams. ICODE has no effect on pointer processing. In TU3 mode,
ICODE must be set to 0 for the C2 byte to indicate unequipped.
MONIS:
The MONIS bit controls the source of pointer justification interrupts. When
MONIS is set high, the incoming stream is monitored for tributary pointer
justification events. When MONIS is set low, the outgoing stream is
monitored for pointer justification events. Interrupts can be optionally
generated upon a pointer justification event in the monitored stream.
SOS:
The SOS bit controls the spacing between consecutive pointer justification
events on the incoming stream. When SOS is set high, the definition of
inc_ind and dec_ind indications includes the requirement that active offset
changes have occurred at least three frames ago. When SOS is set low,
pointer justification indications in the incoming stream are followed without
regard to the proximity of previous active offset change.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
82
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
TUGEN:
When set high, the TUGEN bit enables the processing of tributaries in
STS-1 #3 (TUG3 #3). When TUGEN is low, VTPP #3, RTOP #3 and RTTB #3
are held in a low power, reset state. The data in STS-1 #3 (TUG3 #3) is retransmitted unchanged on the outgoing data stream. The amount of delay
from the incoming to the outgoing data stream is a function of the separation
between the IC1J1 and OC1J1 inputs. See the bypass functional timing
diagram for details. When TUGEN is toggled low, the VTTP #3, RTOP #3,
and RTTB #3 registers with addresses 0x60H and higher are reset to their
default states.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
83
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 07H: Tributary Payload Processor and LOM Interrupt Enable
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
R/W
LOM3E
0
Bit 4
R/W
LOM2E
0
Bit 3
R/W
LOM1E
0
Bit 2
R/W
VTPP3E
0
Bit 1
R/W
VTPP2E
0
Bit 0
R/W
VTPP1E
0
This register provides interrupt enable of the three H4 byte framers and of the
three tributary payload processors in the TUPP-PLUS.
VTPP1E:
VTPP1E is the interrupt enable bit for tributary payload processor #1 in the
TUPP-PLUS. Interrupts enabled at tributary processor #1 but masked by
VTPP1E will still be reported by the VTPP1I bit, although the interrupt output
will not be activated. Interrupts disabled at tributary payload processor #1 will
not be reported by the VTPP1I bit.
VTPP2E:
VTPP2E is the interrupt enable bit for tributary processor #2 in the
TUPP-PLUS. Interrupts enabled at tributary payload processor #2 but
masked by VTPP2E will still be reported by the VTPP2I bit, although the
interrupt output will not be activated. Interrupts disabled at tributary payload
processor #2 will not be reported by the VTPP2I bit.
VTPP3E:
VTPP3E is the interrupt enable bit for tributary payload processor #3 in the
TUPP-PLUS. Interrupts enabled at tributary processor #3 but masked by
VTPP3E will still be reported by the VTPP3I bit, although the interrupt output
will not be activated. Interrupts disabled at tributary payload processor #3 will
not be reported by the VTPP3I bit.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
84
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
LOM1E:
The LOM1E bit is an interrupt enable bit for the H4 framer out of frame
interrupt in tributary payload processor #1. When LOM1E is set high, a
change in the framer out of frame status will cause an interrupt to be
generated on the INTB output. Interrupts are masked when LOME is set low.
LOM2E:
The LOM2E bit is an interrupt enable bit for the H4 framer out of frame
interrupt in tributary payload processor #2. When LOM2E is set high, a
change in the framer out of frame status will cause an interrupt to be
generated on the INTB output. Interrupts are masked when LOME is set low.
When ICONCAT is set to logic 1 this interrupt enable bit should be set to logic
0. In the AU4 mode the multiframe alignment is determined by the H4 byte
framer in tributary payload processor #1.
LOM3E:
The LOM3E bit is an interrupt enable bit for the H4 framer out of frame
interrupt in tributary payload processor #3. When LOM3E is set high, a
change in the framer out of frame status will cause an interrupt to be
generated on the INTB output. Interrupts are masked when LOME is set low.
When ICONCAT is set to logic 1 this interrupt enable bit should be set to logic
0. In the AU4 mode the multiframe alignment is determined by the H4 byte
framer in tributary payload processor #1.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
85
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 08H: Tributary Payload Processor Interrupt and LOM Status
Bit
Type
Function
Default
ZBit 7
Unused
X
Bit 6
Unused
X
Bit 5
R
LOM3V
0
Bit 4
R
LOM2V
0
Bit 3
R
LOM1V
0
Bit 2
R
VTPP3I
0
Bit 1
R
VTPP2I
0
Bit 0
R
VTPP1I
0
This register provides interrupt status of the three H4 byte framers and of the
three tributary payload processors in the TUPP-PLUS.
VTPP1I:
VTPP1I identifies tributary payload processor #1 as the source of a pending
interrupt. It is necessary to read the various interrupt status registers in
tributary payload processor #1 to determine the event causing the interrupt
and to clear the interrupt. Interrupts disabled at tributary payload processor
#1 will not be reported by the VTPP1I bit.
VTPP2I:
VTPP2I identifies tributary payload processor #2 as the source of a pending
interrupt. It is necessary to read the various interrupt status registers in
tributary payload processor #2 to determine the event causing the interrupt
and to clear the interrupt. Interrupts disabled at tributary payload processor
#2 will not be reported by the VTPP2I bit.
VTPP3I:
VTPP1I identifies tributary payload processor #3 as the source of a pending
interrupt. It is necessary to read the various interrupt status registers in
tributary payload processor #3 to determine the event causing the interrupt
and to clear the interrupt. Interrupts disabled at tributary payload processor
#3 will not be reported by the VTPP3I bit.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
86
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
LOM1V:
The LOM1V bit indicates the status of the H4 byte framer in tributary payload
processor #1. LOM1V is set high when the H4 framer is in loss of multiframe
state and is set low when it re-acquires multiframe alignment.
LOM2V:
The LOM2V bit indicates the status of the H4 byte framer in tributary payload
processor #2. LOM2V is set high when the H4 framer is in loss of multiframe
state and is set low when it re-acquires multiframe alignment. When
ICONCAT is set to logic 1 this status bit should be ignored since the
multiframe alignment is determined by the H4 byte framer in tributary payload
processor #1.
LOM3V:
The LOM3V bit indicates the status of the H4 byte framer in tributary payload
processor #3. LOM3V is set high when the H4 framer is in loss of multiframe
state and is set low when it re-acquires multiframe alignment. When
ICONCAT is set to logic 1 this status bit should be ignored since the
multiframe alignment is determined by the H4 byte framer in tributary payload
processor #1.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
87
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 09H: Parity Error and LOM Interrupt
Bit
Type
Function
Default
R
IPI
0
Unused
X
Bit 7
Bit 6
Bit 5
R
LOM3I
0
Bit 4
R
LOM2I
0
Bit 3
R
LOM1I
0
Bit 2
R/W
Reserve3
1
Bit 1
R/W
Reserve2
1
Bit 0
R/W
Reserve1
1
This register provides interrupt status of the H4 byte framers in the three tributary
payload processor and of the input parity checker in the TUPP-PLUS.
Reserved[3:1]:
The Reserved[3:1] bits must be set high for the correct operation of the
TUPP-PLUS.
LOM1I:
The LOM1I bit indicates a change of status in the H4 byte framer. Interrupts
are generated when the H4 framer in tributary payload processor #1 enters
loss of multiframe state and when it re-acquires multiframe alignment. The
LOM1I bit is set high on entry and exit to the loss of multiframe state and is
cleared immediately following a read of this register, which also
acknowledges and clears the interrupt. The LOMI bit remains valid when
interrupts are not enabled (LOM1E set low) and may be polled to detect out
of frame events.
LOM2I:
The LOM2I bit indicates a change of status in the H4 byte framer. Interrupts
are generated when the H4 framer in tributary payload processor #2 enters
loss of multiframe state and when it re-acquires multiframe alignment. The
LOM2I bit is set high on entry and exit to the loss of multiframe state and is
cleared immediately following a read of this register, which also
acknowledges and clears the interrupt. The LOM2I bit remains valid when
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
88
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
interrupts are not enabled (LOM2E set low) and may be polled to detect out
of frame events.
LOM3I:
The LOM3I bit indicates a change of status in the H4 byte framer. Interrupts
are generated when the H4 framer in tributary payload processor #3 enters
loss of multiframe state and when it re-acquires multiframe alignment. The
LOM3I bit is set high on entry and exit to the loss of multiframe state and is
cleared immediately following a read of this register, which also
acknowledges and clears the interrupt. The LOM3I bit remains valid when
interrupts are not enabled (LOM3E set low) and may be polled to detect out
of frame events.
IPI:
The incoming parity error interrupt bit (IPI) is set high when a parity error is
detected on the incoming parity signal set. If the IPE bit in the master
incoming configuration register is set high, the interrupt output (INTB) is
activated. When this register is read, IPI (and the corresponding interrupt) is
cleared.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
89
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 0AH: Tributary Path Overhead Processor and Tributary trace Buffer
Interrupt Enable
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
R/W
RTTB3E
0
Bit 4
R/W
RTTB2E
0
Bit 3
R/W
RTTB1E
0
Bit 2
R/W
RTOP3E
0
Bit 1
R/W
RTOP2E
0
Bit 0
R/W
RTOP1E
0
This register provides interrupt enable of the three tributary path overhead
processors and of the three tributary trace buffers in the TUPP-PLUS.
RTOP1E:
RTOP1E is the interrupt enable bit for tributary path overhead processor #1 in
the TUPP-PLUS. Interrupts enabled at tributary path overhead processor #1
but masked by RTOP1E will still be reported by the RTOP1I bit, although the
interrupt output will not be activated. Interrupts disabled at tributary path
overhead processor #1 will not be reported by the RTOP1I bit.
RTOP2E:
RTOP2E is the interrupt enable bit for tributary path overhead processor #2 in
the TUPP-PLUS. Interrupts enabled at tributary path overhead processor #2
but masked by RTOP2E will still be reported by the RTOP2I bit, although the
interrupt output will not be activated. Interrupts disabled at tributary path
overhead processor #2 will not be reported by the RTOP2I bit.
RTOP3E:
RTOP3E is the interrupt enable bit for tributary path overhead processor #3 in
the TUPP-PLUS. Interrupts enabled at tributary path overhead processor #3
but masked by RTOP3E will still be reported by the RTOP3I bit, although the
interrupt output will not be activated. Interrupts disabled at tributary path
overhead processor #3 will not be reported by the RTOP3I bit.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
90
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
RTTB1E:
RTTB1E is the interrupt enable bit for tributary trace buffer #1 in the
TUPP-PLUS. Interrupts enabled at tributary trace buffer #1 but masked by
RTTB1E will still be reported by the RTTB1I bit, although the interrupt output
will not be activated. Interrupts disabled at tributary trace buffer #1 will not be
reported by the RTTB1I bit.
RTTB2E:
RTTB2E is the interrupt enable bit for tributary trace buffer #2 in the
TUPP-PLUS. Interrupts enabled at tributary trace buffer #2 but masked by
RTTB2E will still be reported by the RTTB2I bit, although the interrupt output
will not be activated. Interrupts disabled at tributary trace buffer #2 will not be
reported by the RTTB2I bit.
RTTB3E:
RTTB3E is the interrupt enable bit for tributary trace buffer #3 in the
TUPP-PLUS. Interrupts enabled at tributary trace buffer #3 but masked by
RTTB3E will still be reported by the RTTB3I bit, although the interrupt output
will not be activated. Interrupts disabled at tributary trace buffer #3 will not be
reported by the RTTB3I bit.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
91
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 0BH: Tributary Path Overhead Processor and Tributary Trace Buffer
Interrupt Status
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
R
RTTB3I
0
Bit 4
R
RTTB2I
0
Bit 3
R
RTTB1I
0
Bit 2
R
RTOP3I
0
Bit 1
R
RTOP2I
0
Bit 0
R
RTOP1I
0
This register provides interrupt status of the three tributary path overhead
processor and of the three tributary trace buffers in the TUPP-PLUS.
RTOP1I:
RTOP1I identifies tributary path overhead processor #1 as the source of a
pending interrupt. It is necessary to read the various interrupt status registers
in tributary path overhead processor #1 to determine the event causing the
interrupt and to clear the interrupt. Interrupts disabled at tributary path
overhead processor #1 will not be reported by the RTOP1I bit.
RTOP2I:
RTOP2I identifies tributary path overhead processor #2 as the source of a
pending interrupt. It is necessary to read the various interrupt status registers
in tributary path overhead processor #2 to determine the event causing the
interrupt and to clear the interrupt. Interrupts disabled at tributary path
overhead processor #2 will not be reported by the RTOP2I bit.
RTOP3I:
RTOP1I identifies tributary path overhead processor #3 as the source of a
pending interrupt. It is necessary to read the various interrupt status registers
in tributary path overhead processor #3 to determine the event causing the
interrupt and to clear the interrupt. Interrupts disabled at tributary path
overhead processor #3 will not be reported by the RTOP3I bit.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
92
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
RTTB1I:
RTTB1I identifies tributary trace buffer #1 as the source of a pending
interrupt. It is necessary to read the various interrupt status registers in
tributary trace buffer #1 to determine the event causing the interrupt and to
clear the interrupt. Interrupts disabled at tributary trace buffer #1 will not be
reported by the RTTB1I bit.
RTTB2I:
RTTB2I identifies tributary trace buffer #2 as the source of a pending
interrupt. It is necessary to read the various interrupt status registers in
tributary trace buffer #2 to determine the event causing the interrupt and to
clear the interrupt. Interrupts disabled at tributary trace buffer #2 will not be
reported by the RTTB2I bit.
RTTB3I:
RTTB1I identifies tributary trace buffer #3 as the source of a pending
interrupt. It is necessary to read the various interrupt status registers in
tributary trace buffer #3 to determine the event causing the interrupt and to
clear the interrupt. Interrupts disabled at tributary trace buffer #3 will not be
reported by the RTTB3I bit.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
93
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 0CH: RTOP #1 and RTTB #1 Configuration
Bit
Type
Function
Default
Bit 7
R/W
ALGO2
0
Bit 6
R/W
PER5
0
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
R/W
RDI10
0
Bit 2
R/W
PDI[2]
1
Bit 1
R/W
PDI[1]
1
Bit 0
R/W
PDI[0]
0
This register configures the operation of RTOP #1 and RTTB #1.
PDI[2:0]:
The PDI[2:0] bits specifies the code used to convey tributary path defect
indication (PDI-V) in the V5 byte (out of TU3 mode) or the C2 byte (in TU3
mode). For TU3 payloads, the PDI[2] bit is sign extended to form the byte
value used for the PDI-V detection.
RDI10:
The RDI10 bit controls the number of times the tributary path RDI, RFI or the
extended RDI code is filtered before being accepted. When RDI10 is set
high, the RDI bit, the RFI bit or the extended RDI code is filtered for ten
occurrences. When RDI10 is set low, the RDI bit, the RFI bit or the extended
RDI code is filtered for five occurrences.
PER5:
The PER5 bit controls the number of identical tributary path trace messages
needed for the message to become accepted. When PER5 is set high, a
messages is accepted when it is received unchanged five times. When PER5
is set low, the message is accepted after three identical repetitions.
ALGO2:
The ALGO2 bit controls the algorithm used to detect trail trace identifier
unstable alarms. When ALGO2 is set high, a counter starts on the first
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
94
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
dissimilar identifier and cleared to zero when the same identifier is received
enough times to be accepted. TIU is declared when the count exceeds the
programmable TIU threshold. When ALGO2 is set low, the counter
increments on each dissimilar identifier and is cleared to zero when the same
identifier is received enough times to be accepted. TIU is declared when the
count exceeds the programmable TIU threshold.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
95
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 0DH: RTOP #2 and RTTB #2 Configuration
Bit
Type
Function
Default
Bit 7
R/W
ALGO2
0
Bit 6
R/W
PER5
0
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
R/W
RDI10
0
Bit 2
R/W
PDI[2]
1
Bit 1
R/W
PDI[1]
1
Bit 0
R/W
PDI[0]
0
This register configures the operation of RTOP #2 and RTTB #2.
PDI[2:0]:
The PDI[2:0] bits specifies the code used to convey tributary path defect
indication (PDI-V) in the V5 byte (for non-TU3 payloads) or the C2 byte (for
TU3 payloads). For TU3 payloads, the PDI[2] bit is sign extended to form the
byte value used for the PDI-V detection.
RDI10:
The RDI10 bit controls the number of times the tributary path RDI, RFI or the
extended RDI code is filtered before being accepted. When RDI10 is set
high, the RDI bit, the RFI bit or the extended RDI code is filtered for ten
occurrences. When RDI10 is set low, the RDI bit, the RFI bit or the extended
RDI code is filtered for five occurrences.
PER5:
The PER5 bit controls the number of identical tributary path trace messages
needed for the message to become accepted. When PER5 is set high, a
messages is accepted when it is received unchanged five times. When PER5
is set low, the message is accepted after three identical repetitions.
ALGO2:
The ALGO2 bit controls the algorithm used to detect trail trace identifier
unstable alarms. When ALGO2 is set high, a counter starts on the first
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
96
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
dissimilar identifier and cleared to zero when the same identifier is received
enough times to be accepted. TIU is declared when the count exceeds the
programmable TIU threshold. When ALGO2 is set low, the counter
increments on each dissimilar identifier and is cleared to zero when the same
identifier is received enough times to be accepted. TIU is declared when the
count exceeds the programmable TIU threshold.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
97
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 0EH: RTOP #3 and RTTB #3 Configuration
Bit
Type
Function
Default
Bit 7
R/W
ALGO2
0
Bit 6
R/W
PER5
0
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
R/W
RDI10
0
Bit 2
R/W
PDI[2]
1
Bit 1
R/W
PDI[1]
1
Bit 0
R/W
PDI[0]
0
This register configures the operation of RTOP #3 and RTTB #3.
PDI[2:0]:
The PDI[2:0] bits specifies the code used to convey tributary path defect
indication (PDI-V) in the V5 byte (for non-TU3 payloads) or the C2 byte (for
TU3 payloads). For TU3 payloads, the PDI[2] bit is sign extended to form the
byte value used for the PDI-V detection.
RDI10:
The RDI10 bit controls the number of times the tributary path RDI, RFI or the
extended RDI code is filtered before being accepted. When RDI10 is set
high, the RDI bit, the RFI bit or the extended RDI code is filtered for ten
occurrences. When RDI10 is set low, the RDI bit, the RFI bit or the extended
RDI code is filtered for five occurrences.
PER5:
The PER5 bit controls the number of identical tributary path trace messages
needed for the message to become accepted. When PER5 is set high, a
messages is accepted when it is received unchanged five times. When PER5
is set low, the message is accepted after three identical repetitions.
ALGO2:
The ALGO2 bit controls the algorithm used to detect trail trace identifier
unstable alarms. When ALGO2 is set high, a counter starts on the first
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
98
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
dissimilar identifier and cleared to zero when the same identifier is received
enough times to be accepted. TIU is declared when the count exceeds the
programmable TIU threshold. When ALGO2 is set low, the counter
increments on each dissimilar identifier and is cleared to zero when the same
identifier is received enough times to be accepted. TIU is declared when the
count exceeds the programmable TIU threshold.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
99
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 10H: Tributary Alarm AIS Control
Bit
Type
Function
Default
Bit 7
R/W
LOMAIS
0
Bit 6
R/W
LOPAIS
0
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
R/W
PSLMAIS
0
Bit 2
R/W
PSLUAIS
0
Bit 1
R/W
TIMAIS
0
Bit 0
R/W
TIUAIS
0
This register controls the insertion of tributary path AIS as a result of tributary
path signal label alarms, tributary trace identifier alarms and tributary multiframe
alarms.
TIUAIS:
The TIUAIS bit is an active high AIS insertion enable. When TIUAIS is set
high, AIS is automatically generated on the outgoing data stream for all
tributaries that are in trace identifier unstable state. When TIUAIS is set low,
the generation of AIS on the outgoing data stream is inhibited. The negation
of AIS occurs at tributary multiframe boundaries.
TIMAIS:
The TIMAIS bit is an active high AIS insertion enable. When TIMAIS is set
high, AIS is automatically generated on the outgoing data stream for all
tributaries that are in trace identifier mismatch state. When TIMAIS is set low,
the generation of AIS on the outgoing data stream is inhibited. The negation
of AIS occurs at tributary multiframe boundaries.
PSLUAIS:
The PSLUAIS bit is an active high AIS insertion enable. When PSLUAIS is
set high, AIS is automatically generated on the outgoing data stream for all
tributaries that are in path signal label unstable state. When PSLUAIS is set
low, the generation of AIS on the outgoing data stream is inhibited. The
negation of AIS occurs at tributary multiframe boundaries.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
100
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
PSLMAIS:
The PSLMAIS bit is an active high AIS insertion enable. When PSLMAIS is
set high, AIS is automatically generated on the outgoing data stream for all
tributaries that are in path signal label mismatch state. When PSLMAIS is set
low, the generation of AIS on the outgoing data stream is inhibited. The
negation of AIS occurs at tributary multiframe boundaries.
LOPAIS:
The LOPAIS bit is an active high AIS insertion enable. When LOPAIS is set
high, AIS is automatically generated on the outgoing data stream for all
tributaries that are in loss of pointer state. When LOPAIS is set low, the
generation of AIS on the outgoing data stream is inhibited. The negation of
AIS occurs at tributary multiframe boundaries. This bit is logically OR'ed with
the bit of the same name in TUPP-PLUS Master Incoming Configuration
register.
LOMAIS:
The LOMAIS bit is an active high AIS insertion enable. When LOMAIS is set
high, AIS is automatically generated on the outgoing data stream for all
tributaries that are in loss of tributary multiframe state. When LOMAIS is set
low, the generation of AIS on the outgoing data stream is inhibited. LOMAIS
has no effect on TU3 streams.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
101
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 11H: Tributary Remote Defect Indication Control
Bit
Type
Function
Default
Bit 7
R/W
LOMRDI
0
Bit 6
R/W
LOPRDI
0
Bit 5
R/W
AISRDI
0
Bit 4
R/W
UNEQRDI
0
Bit 3
R/W
PSLMRDI
0
Bit 2
R/W
PSLURDI
0
Bit 1
R/W
TIMRDI
0
Bit 0
R/W
TIURDI
0
This register controls the insertion of tributary path RDI on the receive alarm port
(RAD) and optionally on the V5 byte (G1 in TU3 mode) as a result of tributary
pointer alarms, tributary path signal label alarms, tributary trace identifier alarms
and tributary multiframe alarms.
TIURDI:
The TIURDI bit is an active high RDI insertion enable. When TIURDI is set
high, RDI is reported on RAD and optionally in the V5 byte (G1 byte in TU3
mode) of the outgoing data stream for all tributaries that are in trace identifier
unstable state. When TIURDI is set low, reporting of RDI due to TIU is
inhibited.
TIMRDI:
The TIMRDI bit is an active high RDI insertion enable. When TIMRDI is set
high, RDI is reported on RAD and optionally in the V5 byte (G1 byte in TU3
mode) of the outgoing data stream for all tributaries that are in trace identifier
mismatch state. When TIURDI is set low, reporting of RDI due to TIM is
inhibited.
PSLURDI:
The PSLURDI bit is an active high RDI insertion enable. When PSLURDI is
set high, RDI is reported on RAD and optionally in the V5 byte (G1 byte in
TU3 mode) of the outgoing data stream for all tributaries that are in path
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
102
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
signal label unstable state. When PSLURDI is set low, reporting of RDI due
to PSLU is inhibited.
PSLMRDI:
The PSLMRDI bit is an active high RDI insertion enable. When PSLMRDI is
set high, RDI is reported on RAD and optionally in the V5 byte (G1 byte in
TU3 mode) of the outgoing data stream for all tributaries that are in path
signal label mismatch state. When PSLMRDI is set low, reporting of RDI due
to PSLM is inhibited.
UNEQRDI:
The UNEQRDI bit is an active high RDI insertion enable. When UNEQRDI is
set high, RDI is reported on RAD and optionally in the V5 byte (G1 byte in
TU3 mode) of the outgoing data stream for all tributaries that are in
unequipped state. When UNEQRDI is set low, reporting of RDI due to UNEQ
is inhibited.
AISRDI:
The AISRDI bit is an active high RDI insertion enable. When AISRDI is set
high, RDI is reported on RAD and optionally the V5 byte (G1 byte in TU3
mode) of the outgoing data stream for all tributaries that are in incoming AIS
state. When AISRDI is set low, reporting of RDI due to AIS is inhibited.
LOPRDI:
The LOPRDI bit is an active high RDI insertion enable. When LOPRDI is set
high, RDI is reported on RAD and optionally the V5 byte (G1 byte in TU3
mode) of the outgoing data stream for all tributaries that are in loss of pointer
state. When LOPRDI is set low, reporting of RDI due to LOP is inhibited.
LOMRDI:
The LOMRDI bit is an active high RDI insertion enable. When LOMRDI is set
high, RDI is reported on RAD and optionally in the V5 byte (G1 byte in TU3
mode) of the outgoing data stream for all tributaries that are in loss of
multiframe state. When LOMRDI is set low, reporting of RDI due to LOM is
inhibited.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
103
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 12H: Tributary Auxiliary Remote Defect Indication Control
Bit
Type
Function
Default
Bit 7
R/W
NOLOMARDI
1
Bit 6
R/W
NOLOPARDI
1
Bit 5
R/W
NOAISARDI
1
Bit 4
R/W
UNEQARDI
0
Bit 3
R/W
PSLMARDI
0
Bit 2
R/W
PSLUARDI
0
Bit 1
R/W
TIMARDI
0
Bit 0
R/W
TIUARDI
0
This register controls the insertion of tributary path auxiliary RDI on the receive
alarm port (RAD) and optionally on the V5 byte (G1 in TU3 mode) as a result of
tributary pointer alarms, tributary path signal label alarms, tributary trace
identifier alarms and tributary multiframe alarms.
TIUARDI:
The TIUARDI bit is an active high auxiliary RDI insertion enable. When
TIUARDI is set high, ARDI is reported on RAD and optionally in the V5 byte
(G1 byte in TU3 mode) of the outgoing data stream for all tributaries that are
in trace identifier unstable state. When TIURDI is set low, reporting of
auxiliary RDI due to TIM is inhibited.
TIMARDI:
The TIMARDI bit is an active high auxiliary RDI insertion enable. When
TIMARDI is set high, ARDI is reported on RAD and optionally in the V5 byte
(G1 byte in TU3 mode) of the outgoing data stream for all tributaries that are
in trace identifier mismatch state. When TIUARDI is set low, reporting of
auxiliary RDI due to TIM is inhibited.
PSLUARDI:
The PSLUARDI bit is an active high auxiliary RDI insertion enable. When
PSLUARDI is set high, ARDI is reported on RAD and optionally in the V5 byte
(G1 byte in TU3 mode) of the outgoing data stream for all tributaries that are
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
104
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
in path signal label unstable state. When PSLUARDI is set low, reporting of
auxiliary RDI due to PSLU is inhibited.
PSLMARDI:
The PSLMARDI bit is an active high auxiliary RDI insertion enable. When
PSLMARDI is set high, ARDI is reported on RAD and optionally in the V5
byte (G1 byte in TU3 mode) of the outgoing data stream for all tributaries that
are in path signal label mismatch state. When PSLMARDI is set low,
reporting of auxiliary RDI due to PSLM is inhibited.
UNEQARDI:
The UNEQARDI bit is an active high auxiliary RDI insertion enable. When
UNEQARDI is set high, ARDI is reported on RAD and optionally in the V5
byte (G1 byte in TU3 mode) of the outgoing data stream for all tributaries that
are in unequipped state. When UNEQARDI is set low, the reporting of
auxiliary RDI due to UNEQ is inhibited.
NOLOPARDI:
The NOLOPARDI bit is an active high auxiliary RDI insertion disable. When
NOLOPARDI is set high, ARDI is not reported on RAD nor in the V5 byte (G1
byte in TU3 mode) of the outgoing data stream for all tributaries that are in
loss of pointer state. NOLOPARDI has precedence over TIUARDI, TIMARDI,
PSLUARDI and PSLMARDI. When NOLOPARDI is set low, reporting of RDI
is according to TIUARDI, TIMARDI, PSLUARDI and PSLMARDI and the
associated alarm states.
NOAISARDI:
The NOAISARDI bit is an active high auxiliary RDI insertion disable. When
NOAISARDI is set high, auxiliary RDI is not reported on RAD nor in the V5
byte (G1 byte in TU3 mode) of the outgoing data stream for all tributaries that
are in incoming AIS state. NOAISARDI has precedence over TIUARDI,
TIMARDI, PSLUARDI and PSLMARDI. When NOAISARDI is set low,
reporting of RDI is according to TIUARDI, TIMARDI, PSLUARDI and
PSLMARDI and the associated alarm states.
NOLOMARDI:
The NOLOMARDI bit is an active high auxiliary RDI insertion disable. When
NOLOMARDI is set high, ARDI is not reported on RAD nor in the V5 byte (G1
byte in TU3 mode) of the outgoing data stream for all tributaries that are in
loss of multiframe state. When NOLOMARDI is set low, reporting of RDI is
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
105
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
according to TIUARDI, TIMARDI, PSLUARDI and PSLMARDI and the
associated alarm states.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
106
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 13H: Tributary PDI Control
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R/W
LOPPDI
0
Bit 5
R/W
AISPDI
0
Bit 4
R/W
UNEQPDI
0
Bit 3
R/W
PDIVPDI
0
Bit 2
Unused
X
Bit 1
Unused
X
Bit 0
Unused
X
This register controls the insertion of tributary path defect indications (PDI) on
the receive alarm port (RAD) as a result of tributary pointer alarms, tributary
unequipped alarms, and tributary path defect indication alarms.
PDIVPDI:
The PDIVPDI bit is an active high path PDI insertion enable. When PDIVPDI
is set high, PDI-P is reported on RAD when tributary path defect indication
(nominally 'b110) is detected in the tributary path signal label of the
associated incoming tributary. When PDIVPDI is set low, reporting of path
PDI due to PDI-V is inhibited.
UNEQPDI:
The UNEQPDI bit is an active high path PDI insertion enable. When
UNEQPDI is set high, PDI-P is reported on RAD when tributary unequipped
indication ('b000) is detected in the tributary path signal label of the
associated incoming tributary. When UNEQPDI is set low, reporting of path
PDI due to UNEQ is inhibited.
AISPDI:
The AISPDI bit is an active high path PDI insertion enable. When AISPDI is
set high, PDI-P is reported on RAD when the associated incoming tributary is
in AIS state. When AISPDI is set low, reporting of path PDI due to AIS is
inhibited.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
107
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
LOPPDI:
The LOPPDI bit is an active high path PDI insertion enable. When LOPPDI is
set high, PDI-P is reported on RAD when the associated incoming tributary is
in loss of pointer state. When LOPPDI is set low, reporting of path PDI due to
LOP is inhibited.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
108
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
9.2
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
VTPP #1, VTPP #2 and VTPP #3 Registers
Register 20H, 40H, 60H: VTPP, TU3 or TU #1 in TUG2 #1, Configuration and
Status
Bit
Type
Function
Default
Bit 7
R/W
CONFIG[1]
1
Bit 6
R/W
CONFIG[0]
1
Bit 5
R/W
PF
0
Bit 4
R
LOPV
X
Bit 3
R/W
ALARME
0
Bit 2
R/W
DLOP
0
Bit 1
R/W
IIDLE
0
Bit 0
R/W
IPAIS
0
In TU3 mode (TU3 bit in VTPP Configuration register set high), this register
reports the status and configures operational modes of the TU3 mapped into a
TUG3 handled by the VTPP. Out of TU3 mode, this register reports the status
and configures the operational modes of TU #1 in TUG2 #1.
IPAIS:
The IPAIS bit enables the insertion of path AIS for tributary TU #1 in TUG2 #1
or TU3 depending on whether the VTPP is in TU3 mode. Tributary path AIS is
inserted by forcing all ones into all tributary bytes. The IPAIS bit has no effect
when IIDLE is set high.
IIDLE:
The IIDLE bit enables the insertion of path idle for tributary TU #1 in TUG2 #1
or TU3 depending on whether the VTPP is in TU3 mode. When IIDLE is set
high, tributary payload bytes, except V5 is replaced by the idle code. The V5
byte is always set to all-zero to yield correct BIP-2 and to indicate tributary
unequipped. The outgoing pointer is computed from the incoming pointer
value and the relative frame offsets as per normal. The idle code is
selectable to be all zeros or all ones as controlled by the ICODE bit. In order
for the C2 byte to be labeled unequipped, the ICODE bit must be set low in
TU3 mode. The IIDLE bit has precedence over the IPAIS bit.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
109
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
DLOP:
The DLOP bit allows downstream pointer processing elements to be
diagnosed. When DLOP is set high, the new data flag (NDF) field of the
outgoing payload pointer in tributary TU #1 in TUG2 #1 or TU3 depending on
whether the VTPP is in TU3 mode, is inverted to cause downstream pointer
processing elements to enter a loss of pointer state. Insertion of an inverted
new data flag can occur in concert with the insertion of a normal idle
(unequipped) indication as directed by the IIDLE bit. The DLOP bit has no
effect when the IPAIS bit is set high.
ALARME:
The ALARME bit enables loss of pointer and path AIS interrupts for tributary
TU #1 in TUG2 #1 or TU3 depending on whether the VTPP is in TU3 mode.
When ALARME is set high, an interrupt is generated upon entry to and exit
from the LOP and AIS state of the pointer interpreter state diagram.
Interrupts due to AIS and LOP status change are masked when ALARME is
set low.
LOPV:
The LOPV bit indicates the loss of pointer status of tributary TU #1 in TUG2
#1 or TU3 depending on whether the VTPP is in TU3 mode.
PF:
The PF bit enables pointer follower mode for tributary TU #1 in TUG2 #1 or
TU3 depending on whether the VTPP is in TU3 mode. In pointer follower
mode, the tributary FIFO dead-zone is collapsed so that any variation in FIFO
depth will result in an outgoing pointer justification event. Any TU pointer
justification event on the corresponding incoming tributary, or an AU pointer
justification event affecting this tributary will cause an outgoing pointer
justification event.
CONFIG[1:0]:
The CONFIG[1:0] bits specify the tributary configuration of tributary group
TUG2 #1. The CONFIG[1:0] bits have no effect in TU3 mode. The
configuration specified by the CONFIG[1:0] bits are selected as follows:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
110
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
CONFIG[1]
CONFIG[0]
Configuration
Active TU (VT)
0
0
TU2 (VT6)
#1
0
1
VT3
#1, #2
1
0
TU12 (VT2)
#1, #2, #3
1
1
TU11 (VT1.5)
#1, #2, #3, #4
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
111
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 21H-26H, 41H-46H, 61H-66H: VTPP, TU #1 in TUG2 #2 to TUG2 #7,
Configuration and Status
Bit
Type
Function
Default
Bit 7
R/W
CONFIG[1]
1
Bit 6
R/W
CONFIG[0]
1
Bit 5
R/W
PF
0
Bit 4
R
LOPV
X
Bit 3
R/W
ALARME
0
Bit 2
R/W
DLOP
0
Bit 1
R/W
IIDLE
0
Bit 0
R/W
IPAIS
0
This set of registers reports the status and configures the operational modes of
TU #1 in TUG2 #2 to TUG2 #7. These registers have no effect in TU3 mode.
IPAIS:
The IPAIS bit enables the insertion of path AIS for tributary TU #1 in the
corresponding TUG2. Tributary path AIS is inserted by forcing all ones into all
tributary bytes. The IPAIS bit has no effect when IIDLE is set high.
IIDLE:
The IIDLE bit enables the insertion of path idle for tributary TU #1 in the
corresponding TUG2 . When IIDLE is set high, tributary payload bytes,
except V5 is replaced by the idle code. The V5 byte is always set to all-zero
to yield correct BIP-2 and to indicate tributary unequipped. The outgoing
pointer is computed from the incoming pointer value and the relative frame
offsets as per normal. The idle code is selectable to be all zeros or all ones
as controlled by the ICODE bit. In order for the C2 byte to be labeled
unequipped, the ICODE bit must be set low in TU3 mode. The IIDLE bit has
precedence over the IPAIS bit.
DLOP:
The DLOP bit allows downstream pointer processing elements to be
diagnosed. When DLOP is set high, the new data flag (NDF) field of the
outgoing payload pointer in tributary TU #1 in the corresponding TUG2 is
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
112
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
inverted to cause downstream pointer processing elements to enter a loss of
pointer state. Insertion of an inverted new data flag can occur in concert with
the insertion of a normal idle (unequipped) indication as directed by the IIDLE
bit. The DLOP bit has no effect when the IPAIS bit is set high.
ALARME:
The ALARME bit enables loss of pointer and path AIS interrupts for tributary
TU #1 in the corresponding TUG2. When ALARME is set high, an interrupt is
generated upon entry to and exit from the LOP and AIS state of the pointer
interpreter state diagram. Interrupts due to AIS and LOP status change are
masked when ALARME is set low.
LOPV:
The LOPV bit indicates the loss of pointer status of tributary TU #1 in the
corresponding TUG2.
PF:
The PF bit enables pointer follower mode for tributary TU #1 in the
corresponding TUG2. In pointer follower mode, the tributary FIFO dead-zone
is collapsed so that any variation in FIFO depth will result in an outgoing
pointer justification event. Any TU pointer justification event on the
corresponding incoming tributary, or an AU pointer justification event affecting
this tributary will cause an outgoing pointer justification event.
CONFIG[1:0]:
The CONFIG[1:0] bits specify the tributary configuration of the TUG2 tributary
group. The CONFIG[1:0] bits have no effect in TU3 mode. The configuration
specified by the CONFIG[1:0] bits are selected as follows:
CONFIG[1]
CONFIG[0]
Configuration
Active TU (VT)
0
0
TU2 (VT6)
#1
0
1
VT3
#1, #2
1
0
TU12 (VT2)
#1, #2, #3
1
1
TU11 (VT1.5)
#1, #2, #3, #4
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
113
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 27H, 47H, 67H: VTPP, TU3 or TU #1 in TUG2 #1 to TUG2 #7, LOP
Interrupt
Bit
Type
Function
Default
Bit 7
R/W
Reserved
0
Bit 6
R
LOP7I
0
Bit 5
R
LOP6I
0
Bit 4
R
LOP5I
0
Bit 3
R
LOP4I
0
Bit 2
R
LOP3I
0
Bit 1
R
LOP2I
0
Bit 0
R
LOP1I
0
This register is used to identify and acknowledge loss of pointer interrupts for the
tributaries TU #1 in TUG2 #1 to TUG2 #7. It is also used to identify and
acknowledge TU3 loss of pointer interrupts.
LOP1I:
The LOP1I bit identifies the source of loss of pointer interrupts. In TU3 mode,
the LOP1I bit reports and acknowledges LOP interrupt of the TU3 pointer.
Out of TU3 mode, the LOP1I bit reports and acknowledges LOP interrupt of
TU #1 in TUG2 #1. Interrupts are generated upon loss of pointer and upon
re-acquisition. LOP1I is set high when the corresponding loss of pointer
event occurs and are cleared immediately following a read of this register,
which also acknowledges and clears the interrupt. LOP1I remains valid when
interrupts are not enabled (ALARME set low) and may be polled to detect
loss of pointer events.
LOP2I-LOP7I:
The LOP2I to LOP7I bits identify the source of loss of pointer interrupts. In
TU3 mode, these bits are unused and will return a logic 0 when read. Out of
TU3 mode, the LOP2I to LOP7I bits report and acknowledge LOP interrupt of
TU #1 in TUG2 #2 to TUG2 #7, respectively. Interrupts are generated upon
loss of pointer and upon re-acquisition. An LOP xI bit is set high when a loss
of pointer event on the associated tributary (TU #1 in TUG2 #x) occurs and
are cleared immediately following a read of this register, which also
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
114
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
acknowledges and clears the interrupt. LOPxI remains valid when interrupts
are not enabled (ALARME set low) and may be polled to detect loss of
pointer events.
Reserved:
The Reserved bit must be written with a logic 0 for proper operation of the
TUPP-PLUS.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
115
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 28H-2EH, 48H-4EH, 68H-6EH: VTPP, TU #2 in TUG2 #1 to TUG2 #7,
Configuration and Status
Bit
Type
Function
Default
Bit 7
R
CONFIG[1]
1
Bit 6
R
CONFIG[0]
1
Bit 5
R/W
PF
0
Bit 4
R
LOPV
X
Bit 3
R/W
ALARME
0
Bit 2
R/W
DLOP
0
Bit 1
R/W
IIDLE
0
Bit 0
R/W
IPAIS
0
This set of registers reports the status and configures the operational modes of
TU #2 in TUG2 #1 to TUG2 #7. These registers have no effect in TU3 mode.
When the corresponding TUG2 tributary group is configured to TU2 (VT6) mode,
the associated register in this set has no effect.
IPAIS:
The IPAIS bit enables the insertion of path AIS for tributary TU #2 in the
corresponding TUG2. Tributary path AIS is inserted by forcing all ones into all
tributary bytes. The IPAIS bit has no effect when IIDLE is set high.
IIDLE:
The IIDLE bit enables the insertion of path idle for tributary TU #2 in the
corresponding TUG2. When IIDLE is set high, tributary payload bytes, except
V5 is replaced by the idle code. The V5 byte is always set to all-zero to yield
correct BIP-2 and to indicate tributary unequipped. The outgoing pointer is
computed from the incoming pointer value and the relative frame offsets as
per normal. The idle code is selectable to be all zeros or all ones as
controlled by the ICODE bit. In order for the C2 byte to be labeled
unequipped, the ICODE bit must be set low in TU3 mode. The IIDLE bit has
precedence over the IPAIS bit.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
116
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
DLOP:
The DLOP bit allows downstream pointer processing elements to be
diagnosed. When DLOP is set high, the new data flag (NDF) field of the
outgoing payload pointer in tributary TU #2 in the corresponding TUG2 is
inverted, causing downstream pointer processing elements to enter a loss of
pointer state. Insertion of an inverted new data flag can occur in concert with
the insertion of a normal idle (unequipped) indication as directed by the IIDLE
bit. The DLOP bit has no effect when the IPAIS bit is set high.
ALARME:
The ALARME bit enables loss of pointer and path AIS interrupts for tributary
TU #2 in the corresponding TUG2. When ALARME is set high, an interrupt is
generated upon entry to and exit from the LOP and AIS state of the pointer
interpreter state diagram. Interrupts due to AIS and LOP status change are
masked when ALARME is set low.
LOPV:
The LOPV bit indicates the loss of pointer status of tributary TU #2 in the
corresponding TUG2.
PF:
The PF bit enables pointer follower mode for tributary TU #2 in the
corresponding TUG2. In pointer follower mode, the tributary FIFO dead-zone
is collapsed so that any variation in FIFO depth will result in an outgoing
pointer justification event. Any TU pointer justification event on the
corresponding incoming tributary, or an AU pointer justification event affecting
this tributary will cause an outgoing pointer justification event.
CONFIG[1:0]:
The CONFIG[1:0] bits are read-only and reflect the values written into the
corresponding register of TU #1. The configuration specified by the
CONFIG[1:0] bits are selected as follows:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
117
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
CONFIG[1]
CONFIG[0]
Configuration
Active TU (VT)
0
0
TU2 (VT6)
#1
0
1
VT3
#1, #2
1
0
TU12 (VT2)
#1, #2, #3
1
1
TU11 (VT1.5)
#1, #2, #3, #4
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
118
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 2FH, 4FH, 6FH: VTPP, TU #2 in TUG2 #1 to TUG2 #7, LOP Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
LOP7I
0
Bit 5
R
LOP6I
0
Bit 4
R
LOP5I
0
Bit 3
R
LOP4I
0
Bit 2
R
LOP3I
0
Bit 1
R
LOP2I
0
Bit 0
R
LOP1I
0
This register is used to identify and acknowledge loss of pointer interrupts for the
tributaries TU #3 in TUG2 #1 to TUG2 #7.
LOP1I-LOP7I:
The LOP1I to LOP7I bits identify the source of loss of pointer interrupts. In
TU3 mode, these bits are unused and will return a logic 0 when read. When
the corresponding TUG2 tributary group is configured for TU2 (VT6) mode,
the associated LOPxI bit is unused and will return a logic 0 when read. When
operational, the LOP1I to LOP7I bits report and acknowledge LOP interrupts
of TU #2 in TUG2 #1 to TUG2 #7, respectively. Interrupts are generated upon
loss of pointer and upon re-acquisition. An LOP xI bit is set high when a loss
of pointer event on the associated tributary occurs and are cleared
immediately following a read of this register, which also acknowledges and
clears the interrupt. LOPxI remains valid when interrupts are not enabled
(ALARME set low) and may be polled to detect loss of pointer events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
119
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 30H-36H, 50H-56H, 70H-76H: VTPP, TU #3 in TUG2 #1 to TUG2 #7,
Configuration and Status
Bit
Type
Function
Default
Bit 7
R
CONFIG[1]
1
Bit 6
R
CONFIG[0]
1
Bit 5
R/W
PF
0
Bit 4
R
LOPV
X
Bit 3
R/W
ALARME
0
Bit 2
R/W
DLOP
0
Bit 1
R/W
IIDLE
0
Bit 0
R/W
IPAIS
0
This set of registers reports the status and configures the operational modes of
TU #3 in TUG2 #1 to TUG2 #7. These registers have no effect in TU3 mode.
When the corresponding TUG2 tributary group is configured to TU2 (VT6) or VT3
mode, the associated register in this set has no effect.
IPAIS:
The IPAIS bit enables the insertion of path AIS for tributary TU #3 in the
corresponding TUG2. Tributary path AIS is inserted by forcing all ones into all
tributary bytes. The IPAIS bit has no effect when IIDLE is set high.
IIDLE:
The IIDLE bit enables the insertion of path idle for tributary TU #3 in the
corresponding TUG2. When IIDLE is set high, tributary payload bytes, except
V5 is replaced by the idle code. The V5 byte is always set to all-zero to yield
correct BIP-2 and to indicate tributary unequipped. The outgoing pointer is
computed from the incoming pointer value and the relative frame offsets as
per normal. The idle code is selectable to be all zeros or all ones as
controlled by the ICODE bit. In order for the C2 byte to be labeled
unequipped, the ICODE bit must be set low in TU3 mode. The IIDLE bit has
precedence over the IPAIS bit.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
120
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
DLOP:
The DLOP bit allows downstream pointer processing elements to be
diagnosed. When DLOP is set high, the new data flag (NDF) field of the
outgoing payload pointer in tributary TU #3 in the corresponding TUG2 is
inverted, causing downstream pointer processing elements to enter a loss of
pointer state. Insertion of an inverted new data flag can occur in concert with
the insertion of a normal idle (unequipped) indication as directed by the IIDLE
bit. The DLOP bit has no effect when the IPAIS bit is set high.
ALARME:
The ALARME bit enables loss of pointer and path AIS interrupts for tributary
TU #3 in the corresponding TUG2. When ALARME is set high, an interrupt is
generated upon entry to and exit from the LOP and AIS state of the pointer
interpreter state diagram. Interrupts due to AIS and LOP status change are
masked when ALARME is set low.
LOPV:
The LOPV bit indicates the loss of pointer status of tributary TU #3 in the
corresponding TUG2.
PF:
The PF bit enables pointer follower mode for tributary TU #3 in the
corresponding TUG2. In pointer follower mode, the tributary FIFO dead-zone
is collapsed so that any variation in FIFO depth will result in an outgoing
pointer justification event. Any TU pointer justification event on the
corresponding incoming tributary, or an AU pointer justification event affecting
this tributary will cause an outgoing pointer justification event.
CONFIG[1:0]:
The CONFIG[1:0] bits are read-only and reflect the values written into the
corresponding register of TU #1. The configuration specified by the
CONFIG[1:0] bits are selected as follows:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
121
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
CONFIG[1]
CONFIG[0]
Configuration
Active TU (VT)
0
0
TU2 (VT6)
#1
0
1
VT3
#1, #2
1
0
TU12 (VT2)
#1, #2, #3
1
1
TU11 (VT1.5)
#1, #2, #3, #4
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
122
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 37H, 57H, 77H: VTPP, TU #3 in TUG2 #1 to TUG2 #7, LOP Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
LOP7I
0
Bit 5
R
LOP6I
0
Bit 4
R
LOP5I
0
Bit 3
R
LOP4I
0
Bit 2
R
LOP3I
0
Bit 1
R
LOP2I
0
Bit 0
R
LOP1I
0
This register is used to identify and acknowledge loss of pointer interrupts for the
tributaries TU #2 in TUG2 #1 to TUG2 #7.
LOP1I-LOP7I:
The LOP1I to LOP7I bits identify the source of loss of pointer interrupts. In
TU3 mode, these bits are unused and will return a logic 0 when read. When
the corresponding TUG2 tributary group is configured for TU2 (VT6) or VT3
mode, the associated LOPxI bit is unused and will return a logic 0 when read.
When operational, the LOP1I to LOP7I bits report and acknowledge LOP
interrupts of TU #3 in TUG2 #1 to TUG2 #7, respectively. Interrupts are
generated upon loss of pointer and upon re-acquisition. An LOP xI bit is set
high when a loss of pointer event on the associated tributary occurs and are
cleared immediately following a read of this register, which also
acknowledges and clears the interrupt. LOPxI remains valid when interrupts
are not enabled (ALARME set low) and may be polled to detect loss of
pointer events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
123
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 38H-3EH, 58H-5EH, 78H-7EH: VTPP, TU #4 in TUG2 #1 to TUG2 #7,
Configuration and Status
Bit
Type
Function
Default
Bit 7
R
CONFIG[1]
1
Bit 6
R
CONFIG[0]
1
Bit 5
R/W
PF
0
Bit 4
R
LOPV
X
Bit 3
R/W
ALARME
0
Bit 2
R/W
DLOP
0
Bit 1
R/W
IIDLE
0
Bit 0
R/W
IPAIS
0
This set of registers reports the status and configures the operational modes of
TU #4 in TUG2 #1 to TUG2 #7. These registers have no effect in TU3 mode.
When the corresponding TUG2 tributary group is configured to TU2 (VT6), VT3
or, TU12 (VT2) mode, the associated register in this set has no effect.
IPAIS:
The IPAIS bit enables the insertion of path AIS for tributary TU #4 in the
corresponding TUG2. Tributary path AIS is inserted by forcing all ones into all
tributary bytes. The IPAIS bit has no effect when IIDLE is set high.
IIDLE:
The IIDLE bit enables the insertion of path idle for tributary TU #4 in the
corresponding TUG2. When IIDLE is set high, tributary payload bytes, except
V5 is replaced by the idle code. The V5 byte is always set to all-zero to yield
correct BIP-2 and to indicate tributary unequipped. The outgoing pointer is
computed from the incoming pointer value and the relative frame offsets as
per normal. The idle code is selectable to be all zeros or all ones as
controlled by the ICODE bit. In order for the C2 byte to be labeled
unequipped, the ICODE bit must be set low in TU3 mode. The IIDLE bit has
precedence over the IPAIS bit.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
124
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
DLOP:
The DLOP bit allows downstream pointer processing elements to be
diagnosed. When DLOP is set high, the new data flag (NDF) field of the
outgoing payload pointer in tributary TU #4 in the corresponding TUG2 is
inverted, causing downstream pointer processing elements to enter a loss of
pointer state. Insertion of an inverted new data flag can occur in concert with
the insertion of a normal idle (unequipped) indication as directed by the IIDLE
bit. The DLOP bit has no effect when the IPAIS bit is set high.
ALARME:
The ALARME bit enables loss of pointer and path AIS interrupts for tributary
TU #4 in the corresponding TUG2. When ALARME is set high, an interrupt is
generated upon entry to and exit from the LOP and AIS state of the pointer
interpreter state diagram. Interrupts due to AIS and LOP status change are
masked when ALARME is set low.
LOPV:
The LOPV bit indicates the loss of pointer status of tributary TU #4 in the
corresponding TUG2.
PF:
The PF bit enables pointer follower mode for tributary TU #4 in the
corresponding TUG2. In pointer follower mode, the tributary FIFO dead-zone
is collapsed so that any variation is FIFO depth will result in an outgoing
pointer justification event. Any TU pointer justification event on the
corresponding incoming tributary, or an AU pointer justification event affecting
this tributary will cause an outgoing pointer justification event.
CONFIG[1:0]:
The CONFIG[1:0] bits are read-only and reflect the values written into the
corresponding register of TU #1. The configuration specified by the
CONFIG[1:0] bits are selected as follows:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
125
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
CONFIG[1]
CONFIG[0]
Configuration
Active TU (VT)
0
0
TU2 (VT6)
#1
0
1
VT3
#1, #2
1
0
TU12 (VT2)
#1, #2, #3
1
1
TU11 (VT1.5)
#1, #2, #3, #4
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
126
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 3FH, 5FH, 7FH: VTPP, TU #4 in TUG2 #1 to TUG2 #7, LOP Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
LOP7I
0
Bit 5
R
LOP6I
0
Bit 4
R
LOP5I
0
Bit 3
R
LOP4I
0
Bit 2
R
LOP3I
0
Bit 1
R
LOP2I
0
Bit 0
R
LOP1I
0
This register is used to identify and acknowledge loss of pointer interrupts for the
tributaries TU #4 in TUG2 #1 to TUG2 #7.
LOP1I-LOP7I:
The LOP1I to LOP7I bits identify the source of loss of pointer interrupts. In
TU3 mode, these bits are unused and will return a logic 0 when read. When
the corresponding TUG2 tributary group is configured for TU2 (VT6), VT3, or
TU12 (VT2) mode, the associated LOPxI bit is unused and will return a logic
0 when read. When operational, the LOP1I to LOP7I bits report and
acknowledge LOP interrupt of TU #4 in TUG2 #1 to TUG2 #7, respectively.
Interrupts are generated upon loss of pointer and upon re-acquisition. An
LOPxI bit is set high when a loss of pointer event on the associated tributary
occurs and are cleared immediately following a read of this register, which
also acknowledges and clears the interrupt. LOP xI remains valid when
interrupts are not enabled (ALARME set low) and may be polled to detect
loss of pointer events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
127
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register A0H, C0H, E0H: VTPP, TU3 or TU #1 in TUG2 #1, Alarm Status
Bit
Type
Function
Default
Bit 7
R
SS[1]
X
Bit 6
R
SS[0]
X
Bit 5
R
NJEI
X
Bit 4
R
PJEI
X
Bit 3
R
ESEI
X
Bit 2
R/W
PEE
0
Bit 1
R
AISV
X
Bit 0
R/W
RELAYAIS
0
In TU3 mode (TU3 bit in VTPP Configuration register set high), this register
reports the alarm status of the TU3 mapped into a TUG3 handled by the VTPP.
Out of TU3 mode, this register reports the alarm status of TU #1 in TUG2 #1.
RELAYAIS:
The RELAYAIS bit controls the number of consecutive AIS_ind indications
required to enter the AIS state for tributary TU #1 in TUG2 #1 or TU3
depending on whether the VTPP is in TU3 mode. When RELAYAIS is set
high, AIS is declared upon receipt of a single AIS_ind indication. When
RELAYAIS is set low, AIS is declared after 3 consecutive AIS_ind indications.
AISV:
The AISV bit indicates the tributary path AIS status of tributary TU #1 in
TUG2 #1 or TU3 depending on whether the VTPP is in TU3 mode.
PEE:
The PEE bit enables pointer event interrupts for tributary TU #1 in TUG2 #1 or
TU3 depending on whether the VTPP is in TU3 mode. When PEE is set high,
an interrupt is generated upon detection of FIFO underflows and overflows,
upon detection of incoming pointer justification events when the MONIS bit is
set high and upon detection of outgoing pointer justification events when the
MONIS bit is set low. Interrupts due to elastic store errors and pointer
justification events are masked when PEE is set low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
128
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
ESEI:
The ESEI bit reports and acknowledges the status of elastic store error
interrupts for tributary TU #1 in TUG2 #1 or TU3 depending on whether the
VTPP is in TU3 mode. Interrupts are generated upon FIFO underflows and
overflows. ESEI is set high when an elastic store error occurs and is cleared
immediately following a read of this register, which also acknowledges and
clears the interrupt. ESEI remains valid when interrupts are not enabled
(PEE set low) and may be polled to detect elastic store error events.
PJEI:
The PJEI bit reports and acknowledges the status of the positive pointer
justification event interrupts for tributary TU #1 in TUG2 #1 or TU3 depending
on whether the VTPP is in TU3 mode. When the MONIS bit is set high,
interrupts are generated upon reception of a positive pointer justification
event in the incoming stream. When the MONIS bit is set low, interrupts are
generated upon generation of a positive pointer justification event in the
outgoing stream. PJEI is set high when a positive pointer justification event
occurs in the monitored stream and is cleared immediately following a read of
this register, which also acknowledges and clears the interrupt. PJEI remains
valid when interrupts are not enabled (PEE set low) and may be polled to
detect positive pointer justification events.
NJEI:
The NJEI bit reports and acknowledges the status of the negative pointer
justification event interrupts for tributary TU #1 in TUG2 #1 or TU3 depending
on whether the VTPP is in TU3 mode. When the MONIS bit is set high,
interrupts are generated upon reception of a negative pointer justification
event in the incoming stream. When the MONIS bit is set low, interrupts are
generated upon generation of a negative pointer justification event in the
outgoing stream. NJEI is set high when a negative pointer justification event
occurs in the monitored stream and is cleared immediately following a read of
this register, which also acknowledges and clears the interrupt. NJEI remains
valid when interrupts are not enabled (PEE set low) and may be polled to
detect negative pointer justification events.
SS[1:0]:
The SS[1:0] bits reports the value of the size bits in the V1 byte of tributary
TU #1 in TUG2 #1 or the H1 byte of tributary TU3 depending on whether the
VTPP is in TU3 mode. The SS[1:0] bits are not filtered and must be software
de-bounced.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
129
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register A1H-A6H, C1H-C6H, E1H-E6H: VTPP, TU #1 in TUG2 #2 to TUG2 #7,
Alarm Status
Bit
Type
Function
Default
Bit 7
R
SS[1]
X
Bit 6
R
SS[0]
X
Bit 5
R
NJEI
X
Bit 4
R
PJEI
X
Bit 3
R
ESEI
X
Bit 2
R/W
PEE
0
Bit 1
R
AISV
X
Bit 0
R/W
RELAYAIS
0
This set of registers reports the alarm status of TU #1 in TUG2 #2 to TUG2 #7.
These registers have no effect in TU3 mode.
RELAYAIS:
The RELAYAIS bit controls the number of consecutive AIS_ind indications
required to enter the AIS state for tributary TU #1 in the corresponding TUG2.
When RELAYAIS is set high, AIS is declared upon receipt of a single AIS_ind
indication. When RELAYAIS is set low, AIS is declared after 3 consecutive
AIS_ind indications.
AISV:
The AISV bit indicates the tributary path AIS status of tributary TU #1 in the
corresponding TUG2.
PEE:
The PEE bit enables pointer event interrupts for tributary TU #1 in the
corresponding TUG2. When PEE is set high, an interrupt is generated upon
detection of FIFO underflows and overflows, upon detection of incoming
pointer justification events when the MONIS bit is set high and upon detection
of outgoing pointer justification events when the MONIS bit is set low.
Interrupts due to elastic store errors and pointer justification events are
masked when PEE is set low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
130
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
ESEI:
The ESEI bit reports and acknowledges the status of elastic store error
interrupts for tributary TU #1 in the corresponding TUG2. Interrupts are
generated upon FIFO underflows and overflows. ESEI is set high when an
elastic store error occurs and is cleared immediately following a read of this
register, which also acknowledges and clears the interrupt. ESEI remains
valid when interrupts are not enabled (PEE set low) and may be polled to
detect elastic store error events.
PJEI:
The PJEI bit reports and acknowledges the status of the positive pointer
justification event interrupts for tributary TU #1 in the corresponding TUG2.
When the MONIS bit is set high, interrupts are generated upon reception of a
positive pointer justification event in the incoming stream. When the MONIS
bit is set low, interrupts are generated upon generation of a positive pointer
justification event in the outgoing stream. PJEI is set high when a positive
pointer justification event occurs in the monitored stream and is cleared
immediately following a read of this register, which also acknowledges and
clears the interrupt. PJEI remains valid when interrupts are not enabled (PEE
set low) and may be polled to detect positive pointer justification events.
NJEI:
The NJEI bit reports and acknowledges the status of the negative pointer
justification event interrupts for tributary TU #1 in the corresponding TUG2.
When the MONIS bit is set high, interrupts are generated upon reception of a
negative pointer justification event in the incoming stream. When the MONIS
bit is set low, interrupts are generated upon generation of a negative pointer
justification event in the outgoing stream. NJEI is set high when a negative
pointer justification event occurs in the monitored stream and is cleared
immediately following a read of this register, which also acknowledges and
clears the interrupt. NJEI remains valid when interrupts are not enabled (PEE
set low) and may be polled to detect negative pointer justification events.
SS[1:0]:
The SS[1:0] bits reports the value of the size bits in the V1 byte of tributary
TU #1 in the corresponding TUG2. The SS[1:0] bits are not filtered and must
be software de-bounced.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
131
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register A7H, C7H, E7H: VTPP, TU3 or TU #1 in TUG2 #1 to TUG2 #7, AIS
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
AIS7I
0
Bit 5
R
AIS6I
0
Bit 4
R
AIS5I
0
Bit 3
R
AIS4I
0
Bit 2
R
AIS3I
0
Bit 1
R
AIS2I
0
Bit 0
R
AIS1I
0
This register is used to identify and acknowledge alarm indication signal
interrupts for the tributaries TU #1 in TUG2 #1 to TUG2 #7. It is also used to
identify and acknowledge TU3 AIS interrupts.
AIS1I:
The AIS1I bit identifies the source of tributary path AIS interrupts. In TU3
mode, the AIS1I bit reports and acknowledges AIS interrupt of the TU3
stream. Out of TU3 mode, the AIS1I bit reports and acknowledges AIS
interrupt of TU #1 in TUG2 #1. Interrupts are generated upon detection and
removal of tributary path AIS alarm. AIS1I is set high when the
corresponding tributary path AIS event occurs and are cleared immediately
following a read of this register, which also acknowledges and clears the
interrupt. AIS1I remains valid when interrupts are not enabled (ALARME set
low) and may be polled to detect tributary path AIS events.
AIS2I-AIS7I:
The AIS2I to AIS7I bits identify the source of tributary path AIS interrupts. In
TU3 mode, these bits are unused and will return a logic 0 when read. Out of
TU3 mode, the AIS2I to AIS7I bits report and acknowledge AIS interrupt of
TU #1 in TUG2 #2 to TUG2 #7, respectively. Interrupts are generated upon
detection and removal of tributary path AIS. An AIS xI bit is set high when a
tributary path AIS event on the associated tributary (TU #1 in TUG2 #x)
occurs and are cleared immediately following a read of this register, which
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
132
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
also acknowledges and clears the interrupt. AISxI remains valid when
interrupts are not enabled (ALARME set low) and may be polled to detect
tributary path AIS events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
133
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register A8H-AEH, C8H-CEH, E8H-EEH: VTPP, TU #2 in TUG2 #1 to TUG2 #7,
Alarm Status
Bit
Type
Function
Default
Bit 7
R
SS[1]
X
Bit 6
R
SS[0]
X
Bit 5
R
NJEI
X
Bit 4
R
PJEI
X
Bit 3
R
ESEI
X
Bit 2
R/W
PEE
0
Bit 1
R
AISV
X
Bit 0
R/W
RELAYAIS
0
This set of registers reports the alarm status of TU #2 in TUG2 #1 to TUG2 #7.
These registers have no effect in TU3 mode. When the corresponding TUG2
tributary group is configured to TU2 (VT6) mode, the associated register in this
set has no effect.
RELAYAIS:
The RELAYAIS bit controls the number of consecutive AIS_ind indications
required to enter the AIS state for tributary TU #2 in the corresponding TUG2.
When RELAYAIS is set high, AIS is declared upon receipt of a single AIS_ind
indication. When RELAYAIS is set low, AIS is declared after 3 consecutive
AIS_ind indications.
AISV:
The AISV bit indicates the tributary path AIS status of tributary TU #2 in the
corresponding TUG2.
PEE:
The PEE bit enables pointer event interrupts for tributary TU #2 in the
corresponding TUG2. When PEE is set high, an interrupt is generated upon
detection of FIFO underflows and overflows, upon detection of incoming
pointer justification events when the MONIS bit is set high and upon detection
of outgoing pointer justification events when the MONIS bit is set low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
134
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Interrupts due to elastic store errors and pointer justification events are
masked when PEE is set low.
ESEI:
The ESEI bit reports and acknowledges the status of elastic store error
interrupts for tributary TU #2 in the corresponding TUG2. Interrupts are
generated upon FIFO underflows and overflows. ESEI is set high when an
elastic store error occurs and is cleared immediately following a read of this
register, which also acknowledges and clears the interrupt. ESEI remains
valid when interrupts are not enabled (PEE set low) and may be polled to
detect elastic store error events.
PJEI:
The PJEI bit reports and acknowledges the status of the positive pointer
justification event interrupts for tributary TU #2 in the corresponding TUG2.
When the MONIS bit is set high, interrupts are generated upon reception of a
positive pointer justification event in the incoming stream. When the MONIS
bit is set low, interrupts are generated upon generation of a positive pointer
justification event in the outgoing stream. PJEI is set high when a positive
pointer justification event occurs in the monitored stream and is cleared
immediately following a read of this register, which also acknowledges and
clears the interrupt. PJEI remains valid when interrupts are not enabled (PEE
set low) and may be polled to detect positive pointer justification events.
NJEI:
The NJEI bit reports and acknowledges the status of the negative pointer
justification event interrupts for tributary TU #2 in the corresponding TUG2.
When the MONIS bit is set high, interrupts are generated upon reception of a
negative pointer justification event in the incoming stream. When the MONIS
bit is set low, interrupts are generated upon generation of a negative pointer
justification event in the outgoing stream. NJEI is set high when a negative
pointer justification event occurs in the monitored stream and is cleared
immediately following a read of this register, which also acknowledges and
clears the interrupt. NJEI remains valid when interrupts are not enabled (PEE
set low) and may be polled to detect negative pointer justification events.
SS[1:0]:
The SS[1:0] bits reports the value of the size bits in the V1 byte of tributary
TU #2 in the corresponding TUG2. The SS[1:0] bits are not filtered and must
be software de-bounced.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
135
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register AFH, CFH, EFH: VTPP, TU #2 in TUG2 #1 to TUG2 #7 AIS Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
AIS7I
0
Bit 5
R
AIS6I
0
Bit 4
R
AIS5I
0
Bit 3
R
AIS4I
0
Bit 2
R
AIS3I
0
Bit 1
R
AIS2I
0
Bit 0
R
AIS1I
0
This register is used to identify and acknowledge tributary path AIS interrupts for
the tributaries TU #2 in TUG2 #1 to TUG2 #7.
AIS1I-AIS7I:
The AIS1I to AIS7I bits identify the source of tributary path AIS interrupts. In
TU3 mode, these bits are unused and will return a logic 0 when read. When
the corresponding TUG2 tributary group is configured for TU2 (VT6) mode,
the associated AISxI bit is unused and will return a logic 0 when read. When
operational, the AIS1I to AIS7I bits report and acknowledge AIS interrupt of
TU #2 in TUG2 #1 to TUG2 #7, respectively. Interrupts are generated upon
detection and removal of tributary path AIS alarm. An AIS xI bit is set high
when a tributary path AIS event on the associated tributary occurs and are
cleared immediately following a read of this register, which also
acknowledges and clears the interrupt. AIS xI remains valid when interrupts
are not enabled (ALARME set low) and may be polled to detect tributary path
AIS events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
136
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register B0H-B6H, D0H-D6H, F0H-F6H: VTPP, TU #3 in TUG2 #1 to TUG2 #7,
Alarm Status
Bit
Type
Function
Default
Bit 7
R
SS[1]
X
Bit 6
R
SS[0]
X
Bit 5
R
NJEI
X
Bit 4
R
PJEI
X
Bit 3
R
ESEI
X
Bit 2
R/W
PEE
0
Bit 1
R
AISV
X
Bit 0
R/W
RELAYAIS
0
This set of registers reports the status and configures the operational modes of
TU #3 in TUG2 #1 to TUG2 #7. These registers have no effect in TU3 mode.
When the corresponding TUG2 tributary group is configured to TU2 (VT6) or VT3
mode, the associated register in this set has no effect.
RELAYAIS:
The RELAYAIS bit controls the number of consecutive AIS_ind indications
required to enter the AIS state for tributary TU #3 in the corresponding TUG2.
When RELAYAIS is set high, AIS is declared upon receipt of a single AIS_ind
indication. When RELAYAIS is set low, AIS is declared after 3 consecutive
AIS_ind indications.
AISV:
The AISV bit indicates the tributary path AIS status of tributary TU #3 in the
corresponding TUG2.
PEE:
The PEE bit enables pointer event interrupts for tributary TU #3 in the
corresponding TUG2. When PEE is set high, an interrupt is generated upon
detection of FIFO underflows and overflows, upon detection of incoming
pointer justification events when the MONIS bit is set high and upon detection
of outgoing pointer justification events when the MONIS bit is set low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
137
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Interrupts due to elastic store errors and pointer justification events are
masked when PEE is set low.
ESEI:
The ESEI bit reports and acknowledges the status of elastic store error
interrupts for tributary TU #3 in the corresponding TUG2. Interrupts are
generated upon FIFO underflows and overflows. ESEI is set high when an
elastic store error occurs and is cleared immediately following a read of this
register, which also acknowledges and clears the interrupt. ESEI remains
valid when interrupts are not enabled (PEE set low) and may be polled to
detect elastic store error events.
PJEI:
The PJEI bit reports and acknowledges the status of the positive pointer
justification event interrupts for tributary TU #3 in the corresponding TUG2.
When the MONIS bit is set high, interrupts are generated upon reception of a
positive pointer justification event in the incoming stream. When the MONIS
bit is set low, interrupts are generated upon generation of a positive pointer
justification event in the outgoing stream. PJEI is set high when a positive
pointer justification event occurs in the monitored stream and is cleared
immediately following a read of this register, which also acknowledges and
clears the interrupt. PJEI remains valid when interrupts are not enabled (PEE
set low) and may be polled to detect positive pointer justification events.
NJEI:
The NJEI bit reports and acknowledges the status of the negative pointer
justification event interrupts for tributary TU #3 in the corresponding TUG2.
When the MONIS bit is set high, interrupts are generated upon reception of a
negative pointer justification event in the incoming stream. When the MONIS
bit is set low, interrupts are generated upon generation of a negative pointer
justification event in the outgoing stream. NJEI is set high when a negative
pointer justification event occurs in the monitored stream and is cleared
immediately following a read of this register, which also acknowledges and
clears the interrupt. NJEI remains valid when interrupts are not enabled (PEE
set low) and may be polled to detect negative pointer justification events.
SS[1:0]:
The SS[1:0] bits reports the value of the size bits in the V1 byte of tributary
TU #3 in the corresponding TUG2. The SS[1:0] bits are not filtered and must
be software de-bounced.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
138
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register B7H, D7H, F7H: VTPP, TU #3 in TUG2 #1 to TUG2 #7, AIS Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
AIS7I
0
Bit 5
R
AIS6I
0
Bit 4
R
AIS5I
0
Bit 3
R
AIS4I
0
Bit 2
R
AIS3I
0
Bit 1
R
AIS2I
0
Bit 0
R
AIS1I
0
This register is used to identify and acknowledge tributary path AIS interrupts for
the tributaries TU #3 in TUG2 #1 to TUG2 #7.
AIS1I-AIS7I:
The AIS1I to AIS7I bits identify the source of tributary path AIS interrupts. In
TU3 mode, these bits are unused and will return a logic 0 when read. When
the corresponding TUG2 tributary group is configured for TU2 (VT6) or VT3
mode, the associated AISxI bit is unused and will return a logic 0 when read.
When operational, the AIS1I to AIS7I bits report and acknowledge AIS
interrupt of TU #3 in TUG2 #1 to TUG2 #7, respectively. Interrupts are
generated upon detection and removal of tributary path AIS alarm. An AIS xI
bit is set high when a tributary path AIS event on the associated tributary
occurs and are cleared immediately following a read of this register, which
also acknowledges and clears the interrupt. AIS xI remains valid when
interrupts are not enabled (ALARME set low) and may be polled to detect
tributary path AIS events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
139
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register B8H-BEH, D8H-DEH, F8H-FEH: VTPP, TU #4 in TUG2 #1 to TUG2 #7,
Alarm Status
Bit
Type
Function
Default
Bit 7
R
SS[1]
X
Bit 6
R
SS[0]
X
Bit 5
R
NJEI
X
Bit 4
R
PJEI
X
Bit 3
R
ESEI
X
Bit 2
R/W
PEE
0
Bit 1
R
AISV
X
Bit 0
R/W
RELAYAIS
0
This set of registers reports the alarm status of TU #4 in TUG2 #1 to TUG2 #7.
These registers have no effect in TU3 mode. When the corresponding TUG2
tributary group is configured to TU2 (VT6), VT3 or TU12 (VT2) mode, the
associated register in this set has no effect.
RELAYAIS:
The RELAYAIS bit controls the number of consecutive AIS_ind indications
required to enter the AIS state for tributary TU #4 in the corresponding TUG2.
When RELAYAIS is set high, AIS is declared upon receipt of a single AIS_ind
indication. When RELAYAIS is set low, AIS is declared after 3 consecutive
AIS_ind indications.
AISV:
The AISV bit indicates the tributary path AIS status of tributary TU #4 in the
corresponding TUG2.
PEE:
The PEE bit enables pointer event interrupts for tributary TU #4 in the
corresponding TUG2. When PEE is set high, an interrupt is generated upon
detection of FIFO underflows and overflows, upon detection of incoming
pointer justification events when the MONIS bit is set high and upon detection
of outgoing pointer justification events when the MONIS bit is set low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
140
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Interrupts due to elastic store errors and pointer justification events are
masked when PEE is set low.
ESEI:
The ESEI bit reports and acknowledges the status of elastic store error
interrupts for tributary TU #4 in the corresponding TUG2. Interrupts are
generated upon FIFO underflows and overflows. ESEI is set high when an
elastic store error occurs and is cleared immediately following a read of this
register, which also acknowledges and clears the interrupt. ESEI remains
valid when interrupts are not enabled (PEE set low) and may be polled to
detect elastic store error events.
PJEI:
The PJEI bit reports and acknowledges the status of the positive pointer
justification event interrupts for tributary TU #4 in the corresponding TUG2.
When the MONIS bit is set high, interrupts are generated upon reception of a
positive pointer justification event in the incoming stream. When the MONIS
bit is set low, interrupts are generated upon generation of a positive pointer
justification event in the outgoing stream. PJEI is set high when a positive
pointer justification event occurs in the monitored stream and is cleared
immediately following a read of this register, which also acknowledges and
clears the interrupt. PJEI remains valid when interrupts are not enabled (PEE
set low) and may be polled to detect positive pointer justification events.
NJEI:
The NJEI bit reports and acknowledges the status of the negative pointer
justification event interrupts for tributary TU #4 in the corresponding TUG2.
When the MONIS bit is set high, interrupts are generated upon reception of a
negative pointer justification event in the incoming stream. When the MONIS
bit is set low, interrupts are generated upon generation of a negative pointer
justification event in the outgoing stream. NJEI is set high when a negative
pointer justification event occurs in the monitored stream and is cleared
immediately following a read of this register, which also acknowledges and
clears the interrupt. NJEI remains valid when interrupts are not enabled (PEE
set low) and may be polled to detect negative pointer justification events.
SS[1:0]:
The SS[1:0] bits reports the value of the size bits in the V1 byte of tributary
TU #4 in the corresponding TUG2. The SS[1:0] bits are not filtered and must
be software de-bounced.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
141
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register BFH, DFH, FFH: VTPP, TU #4 in TUG2 #1 to TUG2 #7, AIS Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
AIS7I
0
Bit 5
R
AIS6I
0
Bit 4
R
AIS5I
0
Bit 3
R
AIS4I
0
Bit 2
R
AIS3I
0
Bit 1
R
AIS2I
0
Bit 0
R
AIS1I
0
This register is used to identify and acknowledge tributary path AIS interrupts for
the tributaries TU #4 in TUG2 #1 to TUG2 #7.
AIS1I-AIS7I:
The AIS1I to AIS7I bits identify the source of tributary path AIS interrupts. In
TU3 mode, these bits are unused and will return a logic 0 when read. When
the corresponding TUG2 tributary group is configured for TU2 (VT6), VT3 or
TU12 (VT2) mode, the associated AISxI bit is unused and will return a logic 0
when read. When operational, the AIS1I to AIS7I bits report and
acknowledge AIS interrupt of TU #4 in TUG2 #1 to TUG2 #7, respectively.
Interrupts are generated upon detection and removal of tributary path AIS
alarm. An AISxI bit is set high when a tributary path AIS event on the
associated tributary occurs and are cleared immediately following a read of
this register, which also acknowledges and clears the interrupt. AIS xI
remains valid when interrupts are not enabled (ALARME set low) and may be
polled to detect tributary path AIS events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
142
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
9.3
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
RTOP #1, RTOP #2 and RTOP #3 Registers
Register 100H, 200H, 300H: RTOP, TU3 or TU #1 in TUG2 #1, Configuration
Bit
Type
Function
Default
Bit 7
R/W
CONFIG[1]
1
Bit 6
R/W
CONFIG[0]
1
Bit 5
R/W
BLKBIP
0
Bit 4
R/W
PSLUE
0
Bit 3
R/W
PSLME
0
Bit 2
R/W
COPSLE
0
Bit 1
R/W
RFIE
0
Bit 0
R/W
RDIE
0
In TU3 mode (TU3 bit in VTPP Configuration register set high), this register
reports the status and configures operational modes of the TU3 mapped into a
TUG3 handled by the RTOP. Out of TU3 mode, this register reports the status
and configures the operational modes of TU #1 in TUG2 #1.
RDIE:
The RDIE bit enables the remote defect indication interrupt for tributary TU #1
in TUG2 #1 or TU3 depending on whether the RTOP is in TU3 mode. When
RDIE is set high, an interrupt is generated upon changes of RDI status.
Interrupts due to RDI status change are masked when RDIE is set low. The
RDI status is derived from bit 8 of the V5 byte when RDIZ7EN is set low and
from bits 5 to 7 of the Z7 byte when RDIZ7EN is set high.
RFIE:
The RFIE bit enables the remote failure indication interrupt for tributary TU #1
in TUG2 #1 or TU3 depending on whether the RTOP is in TU3 mode. When
RDIZ7EN is set low, an interrupt is generated upon assertion and negation
events of the RFIV bit when RFIE is set high. Interrupts due to RFIV status
change are masked when RFIE is set low. When RDIZ7EN is set high, RFIE
is ignored. The RFIE bit is not used when the RTOP is in TU3 mode is
enabled.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
143
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
COPSLE:
The COPSLE bit enables the change of tributary path signal label interrupt for
tributary TU #1 in TUG2 #1 or TU3. When COPSLE is set high, an interrupt is
generated when the accepted path signal label changes. Interrupts due to
change of PSL are masked when COPSLE is set low.
PSLME:
The PSLME bit enables the tributary path signal label mismatch interrupt for
tributary TU #1 in TUG2 #1 or TU3. When PSLME is set high, an interrupt is
generated when the accepted path signal label changes from mismatching
the provisioned PSL to matching the provisioned value, or vice versa.
Interrupts due to PSL mismatch status change are masked when PSLME is
set low.
PSLUE:
The PSLUE bit enables the tributary path signal label unstable interrupt for
tributary TU #1 in TUG2 #1 or TU3. When PSLUE is set high, an interrupt is
generated when the received path signal label becomes unstable or returns
to stable. Interrupts due to PSL unstable status change are masked when
PSLUE is set low.
BLKBIP:
The BLKBIP bit controls the accumulation of tributary BIP-2 errors for the
tributary TU #1 in TUG2 #1 or the TU3 mapped into a TUG3. When BLKBIP
is set high, BIP-2 errors are counted on a block basis; the BIP error count is
incremented by one when one or both of the BIP-2 bits are in error. When
BLKBIP is set low, BIP-2 two errors are counted on a nibble basis; the BIP
error count is incremented once for each BIP-2 bit that is in error.
CONFIG[1:0]:
The CONFIG[1:0] bits specify the tributary configuration of tributary group
TUG2 #1. The CONFIG[1:0] bits have no effect in TU3 mode. The
configuration specified by the CONFIG[1:0] bits are selected as follows:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
144
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
CONFIG[1]
CONFIG[0]
Configuration
Active TU (VT)
0
0
TU2 (VT6)
#1
0
1
VT3
#1, #2
1
0
TU12 (VT2)
#1, #2, #3
1
1
TU11 (VT1.5)
#1, #2, #3, #4
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
145
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 101H, 201H, 301H: RTOP, TU3 or TU #1 in TUG2 #1, Configuration
and Alarm Status
Bit
Type
Function
Default
Bit 7
R/W
RDIZ7EN
0
Bit 6
R/W
TUPTE
0
Bit 5
R/W
PDIVEN
0
Bit 4
R
PSLUV
X
Bit 3
R
PSLMV
X
Bit 2
R
ERDIV[2]
X
Bit 1
R
ERDIV[1]/RFIV
X
Bit 0
R
ERDIV[0]/RDIV
X
In TU3 mode, this register reports the alarm status of the TU3 mapped into a
TUG3. Out of TU3 mode, this register reports alarm status and configures TU #1
in TUG2 #1.
RDIV:
The RDIV bit indicates the remote defect indication status of tributary TU #1
in TUG2 #1 or the TU3 mapped in a TUG3 when RDIZ7EN is low. Out of TU3
mode, RDIV is set high when the RDI bit in the V5 byte is set high for five or
ten consecutive multiframes as determined by the RDI10 bit in the RTOP and
RTTB Configuration registers (addresses 0CH, 0DH, and 0EH). RDIV is set
low when the RDI bit is set low for five or ten consecutive multiframes as
determined by the RDI10 bit.
In TU3 mode, RDIV is set high when the RDI bit in the G1 byte is set high for
five or ten consecutive frames as determined by the RDI10 bit. RDIV is set
low when the RDI bit is set low for five or ten consecutive frames as
determined by the RDI10 bit.
RFIV:
The RFIV bit indicates the remote failure indication status of tributary TU #1 in
TUG2 #1 when RDIZ7EN is set low. RFIV is set high when the RFI bit in the
V5 byte is set high for five or ten consecutive multiframes as determined by
the RDI10 bit in the RTOP and RTTB Configuration registers (addresses
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
146
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
0CH, 0DH, and 0EH). RFIV is set low when the RFI bit is set low for five or
ten consecutive multiframes as determined by the RDI10 bit. RFIV is not
used when TU3 mode is enabled.
ERDIV[2:0]:
The ERDIV[2:0] bits indicates the extended remote defect indication status of
tributary TU #1 in TUG2 #1 or the TU3 mapped in a TUG3 when RDIZ7EN is
set high. The ERDIV[2:0] bits are set to a new code when the same code in
the extended RDI bits of the Z7 byte or the G1 byte is seen for five or ten
consecutive multiframes (frames in TU3 mode) as determined by the RDI10
bit in the RTOP and RTTB Configuration registers (addresses 0CH, 0DH, and
0EH).
PSLMV:
The PSLMV bit indicates the path signal mismatch status of tributary TU #1 in
TUG2 #1 or TU3. PSLMV is set high when the accepted PSL differs from the
provisioned value. PSLMV is set low when the accepted PSL has the same
value as the provisioned one.
PSLUV:
The PSLUV bit indicates the path signal unstable status of tributary TU #1 in
TUG2 #1 or TU3. The PSL unstable counter is incremented if the PSL of the
current multiframe differs from that in the previous multiframe. The counter is
cleared to zero when the same PSL is received for five consecutive
multiframes. The tributary PSL unstable alarm is asserted and PSLUV set
high when the unstable counter reaches five. The PSL unstable alarm is
negated and PSLUV set low when the unstable counter is cleared.
PDIVEN
The PDIVEN bit controls the insertion of tributary path defect indication for
tributary TU #1 in TUG2 #1 or TU3 in the receive alarm port (RAD). When
PDIVEN is set high, PDI-V is asserted regardless of the state of the path
signal label. When PDIVEN is set low, PDI-V is asserted if the incoming path
signal label matches the PDI code in the PDI[2:0] bit of the corresponding
RTOP Configuration register.
TUPTE:
The TUPTE bit determines the alarm conditions under which AIS is inserted
for tributary TU #1 in TUG2 #1 or TU3 mapped in TUG3. TUPTE is set high if
tributary TU #1 or the TU3 is to be terminated in the network element
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
147
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
containing this TUPP-PLUS device. In this case, tributary AIS is automatically
inserted based on the contents of the global Tributary Alarm AIS Control
register (address 10H). TUPTE is set low if tributary TU #1 or the TU3 is part
of the through traffic in the network element containing this TUPP-PLUS
device. In this case, tributary AIS is only inserted when a loss of pointer
(LOP) or a loss of multiframe (LOM) alarm is detected (as determined by the
global Tributary Alarm AIS Control register).
RDIZ7EN:
Out of TU3 mode, the RDIZ7EN indicates which tributary path overhead byte
is used for controlling the ERDI[2:0] or RDI/RFI bits. When RDIZ7EN is set
low, the RDI and RFI bits in the V5 byte are used to control the RDIV and
RFIV register bits. When RDIZ7EN is set high, the three bit extended RDI
code in the Z7 byte is used to control the ERDIV[2:0] register bits.
In TU3 mode, the RDIZ7EN bit is used to control whether RDI or enhanced
RDI is reported. When RDIZ7EN is set low, the RDI bit in the G1 byte is used
to control the RDIV register bit. When RDIZ7EN is set high, the three bit
extended RDI code in the G1 byte is used to control the ERDIV[2:0] register
bits.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
148
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 102H, 202H, 302H: RTOP, TU3 or TU #1 in TUG2 #1, Expected Path
Signal Label
Bit
Type
Function
Default
Bit 7
R/W
EPSL[7]
0
Bit 6
R/W
EPSL[6]
0
Bit 5
R/W
EPSL[5]
0
Bit 4
R/W
EPSL[4]
0
Bit 3
R/W
EPSL[3]
0
Bit 2
R/W
EPSL[2]
0
Bit 1
R/W
EPSL[1]
0
Bit 0
R/W
EPSL[0]
0
In TU3 mode (TU3 bit in VTPP Configuration register set high), this register
configures the expected path signal label of the TU3 mapped into a TUG3
handled by the RTOP. Out of TU3 mode, this register configures the expected
path signal label of TU #1 in TUG2 #1.
EPSL[7:0]:
In TU3 mode, the EPSL[7:0] bits specifies the expected path signal label of
the TU3 stream. Out of TU3 mode, EPSL[2:0] specifies the expected path
signal label of tributary TU #1 in TUG2 #1. The expected PSL is compared
with the accepted PSL to determine the PSLM state.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
149
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 103H, 203H, 303H: RTOP, TU3 or TU #1 in TUG2 #1, Accepted Path
Signal Label
Bit
Type
Function
Default
Bit 7
R/W
APSL[7]
0
Bit 6
R/W
APSL[6]
0
Bit 5
R/W
APSL[5]
0
Bit 4
R/W
APSL[4]
0
Bit 3
R/W
APSL[3]
0
Bit 2
R/W
APSL[2]
0
Bit 1
R/W
APSL[1]
0
Bit 0
R/W
APSL[0]
0
In TU3 mode (TU3 bit in VTPP Configuration register set high), this register
reports the accepted path signal label of the TU3 mapped into a TUG3 handled
by the RTOP. Out of TU3 mode, this register reports the accepted path signal
label of TU #1 in TUG2 #1.
APSL[7:0]:
In TU3 mode, the APSL[7:0] bits reports the accepted path signal label of the
TU3 stream. Out of TU3 mode, APSL[2:0] specifies the accepted path signal
label of tributary TU #1 in TUG2 #1. The expected PSL is compared with the
accepted PSL to determine the PSLM state.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
150
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 104H, 204H, 304H: RTOP, TU3 or TU #1 in TUG2 #1, BIP-2/BIP-8
Error Count LSB
Bit
Type
Function
Default
Bit 7
R
BIP[7]
X
Bit 6
R
BIP[6]
X
Bit 5
R
BIP[5]
X
Bit 4
R
BIP[4]
X
Bit 3
R
BIP[3]
X
Bit 2
R
BIP[2]
X
Bit 1
R
BIP[1]
X
Bit 0
R
BIP[0]
X
Register 105H, 205H, 305H: RTOP, TU3 or TU #1 in TUG2 #1, BIP-2/BIP-8
Error Count MSB
Bit
Type
Function
Default
Bit 7
R
BIP[15]
X
Bit 6
R
BIP[14]
X
Bit 5
R
BIP[13]
X
Bit 4
R
BIP[12]
X
Bit 3
R
BIP[11]
X
Bit 2
R
BIP[10]
X
Bit 1
R
BIP[9]
X
Bit 0
R
BIP[8]
X
In TU3 mode (TU3 bit in VTPP Configuration register set high), these registers
report the number of block interleave parity (BIP-8) errors detected in the TU3
mapped into a TUG3 handled by the RTOP. Out of TU3 mode, this register
reports the number of block interleave parity (BIP-2) errors detected in TU #1 in
TUG2 #1. These registers do not saturate.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
151
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
BIP[15:0]:
The BIP[15:0] bits reports the number of tributary path bit-interleaved parity
errors that have been detected since the last time the BIP-2/BIP-8 registers
were polled. The BIP-2/BIP-8 registers are polled by writing to the Input
Signal Activity, Accumulate Trigger register. The write access transfers the
internally accumulated error count to the BIP-2/BIP-8 registers within 10 µs
and simultaneously resets the internal counter to begin a new cycle of error
accumulation. BIP-2/BIP-8 errors may be accumulated on a nibble/bit basis
or block basis as controlled by the BLKBIP register bit. In TU3 mode, all
BIP[15:0] are valid. Out of TU3 mode, only BIP[10:0] are valid, BIP[15:11] are
held low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
152
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 106H, 206H, 306H: RTOP, TU3 or TU #1 in TUG2 #1, FEBE Error
Count LSB
Bit
Type
Function
Default
Bit 7
R
FEBE[7]
X
Bit 6
R
FEBE[6]
X
Bit 5
R
FEBE[5]
X
Bit 4
R
FEBE[4]
X
Bit 3
R
FEBE[3]
X
Bit 2
R
FEBE[2]
X
Bit 1
R
FEBE[1]
X
Bit 0
R
FEBE[0]
X
Register 107H, 207H, 307H: RTOP, TU3 or TU #1 in TUG2 #1, FEBE Error
Count MSB
Bit
Type
Function
Default
Bit 7
R
FEBE[15]
X
Bit 6
R
FEBE[14]
X
Bit 5
R
FEBE[13]
X
Bit 4
R
FEBE[12]
X
Bit 3
R
FEBE[11]
X
Bit 2
R
FEBE[10]
X
Bit 1
R
FEBE[9]
X
Bit 0
R
FEBE[8]
X
In TU3 mode (TU3 bit in VTPP Configuration register set high), these registers
report the number of far end block errors (FEBE) detected in the TU3 mapped
into a TUG3 handled by the RTOP. Out of TU3 mode, this register reports the
number of far end block errors (FEBE) detected in TU #1 in TUG2 #1.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
153
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
FEBE[15:0]:
The FEBE[15:0] bits reports the number of tributary path far end block errors
that have been detected since the last time the FEBE registers were polled.
The FEBE registers are polled by writing to the Input Signal Activity,
Accumulate Trigger register. The write access transfers the internally
accumulated error counts to the FEBE registers within 10 µs and
simultaneously resets the internal counter to begin a new cycle of error
accumulation.In TU3 mode, all FEBE[15:0] are valid. Out of TU3 mode, only
FEBE[10:0] are valid, FEBE[15:11] are held low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
154
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 108H, 110H, 118H, 120H, 128H, 130H:
Register 208H, 210H, 218H, 220H, 228H, 230H:
Register 308H, 310H, 318H, 320H, 328H, 330H:
RTOP, TU #1 in TUG2 #2 to TUG2 #7, Configuration
Bit
Type
Function
Default
Bit 7
R/W
CONFIG[1]
1
Bit 6
R/W
CONFIG[0]
1
Bit 5
R/W
BLKBIP
0
Bit 4
R/W
PSLUE
0
Bit 3
R/W
PSLME
0
Bit 2
R/W
COPSLE
0
Bit 1
R/W
RFIE
0
Bit 0
R/W
RDIE
0
This set of registers configures the operational modes of TU #1 in TUG2 #2 to
TUG2 #7. These registers have no effect in TU3 mode.
RDIE:
The RDIE bit enables the remote defect indication interrupt for tributary TU #1
in the corresponding TUG2. When RDIE is set high, an interrupt is generated
upon changes of RDI status. Interrupts due to RDI status change are
masked when RDIE is set low. The RDI status is derived from bit 8 of the V5
byte when RDIZ7EN is set low and from bits 5 to 7 of the Z7 byte when
RDIZ7EN is set high.
RFIE:
The RFIE bit enables the remote failure indication interrupt for tributary TU #1
in the correspondiing TUG2. When RDIZ7EN is set low, an interrupt is
generated upon assertion and negation events of the RFIV bit when RFIE is
set high. Interrupts due to RFIV status change are masked when RFIE is set
low. When RDIZ7EN is set high, RFIE is ignored. The RFIE bit is not used
when the RTOP is in TU3 mode is enabled.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
155
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
COPSLE:
The COPSLE bit enables the change of tributary path signal label interrupt for
tributary TU #1 in the corresponding TUG2. When COPSLE is set high, an
interrupt is generated when the accepted path signal label changes.
Interrupts due to change of PSL are masked when COPSLE is set low.
PSLME:
The PSLME bit enables the tributary path signal label mismatch interrupt for
tributary TU #1 in the corresponding TUG2. When PSLME is set high, an
interrupt is generated when the accepted path signal label changes from
mismatching the provisioned PSL to matching the provisioned value, or vice
versa. Interrupts due to PSL mismatch status change are masked when
PSLME is set low.
PSLUE:
The PSLUE bit enables the tributary path signal label unstable interrupt for
tributary TU #1 in the corresponding TUG2. When PSLUE is set high, an
interrupt is generated when the received path signal label becomes unstable
or returns to stable. Interrupts due to PSL unstable status change are
masked when PSLUE is set low.
BLKBIP:
The BLKBIP bit controls the accumulation of tributary BIP-2 errors for the
tributary TU #1 in the corresponding TUG2. When BLKBIP is set high, BIP-2
errors are counted on a block basis; the BIP error count is incremented by
one when one or both of the BIP-2 bits are in error. When BLKBIP is set low,
the BIP error count is incremented once for each BIP-2 bit that is in error.
CONFIG[1:0]:
The CONFIG[1:0] bits specify the tributary configuration of the corresponding
TUG2. The configuration specified by the CONFIG[1:0] bits are selected as
follows:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
156
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
CONFIG[1]
CONFIG[0]
Configuration
Active TU (VT)
0
0
TU2 (VT6)
#1
0
1
VT3
#1, #2
1
0
TU12 (VT2)
#1, #2, #3
1
1
TU11 (VT1.5)
#1, #2, #3, #4
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
157
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 109H, 111H, 119H, 121H, 129H, 131H:
Register 209H, 211H, 219H, 221H, 229H, 231H:
Register 309H, 311H, 319H, 321H, 329H, 331H:
RTOP, TU #1 in TUG2 #2 to TUG2 #7, Configuration and Alarm Status
Bit
Type
Function
Default
Bit 7
R/W
RDIZ7EN
0
Bit 6
R/W
TUPTE
0
Bit 5
R/W
PDIVEN
0
Bit 4
R
PSLUV
X
Bit 3
R
PSLMV
X
Bit 2
R/W
ERDIV[2]
0
Bit 1
R
ERDIV[1]/RFIV
X
Bit 0
R
ERDIV[0]/RDIV
X
This set of registers reports alarm status and configures TU #1 in TUG2 #2 to
TUG2 #7. These registers have no effect in TU3 mode.
RDIV:
The RDIV bit indicates the remote defect indication status of tributary TU #1
in the corresponding TUG2 when RDIZ7EN is low. RDIV is set high when the
RDI bit in the V5 byte is set high for five or ten consecutive multiframes as
determined by the RDI10 bit in the RTOP and RTTB Configuration registers
(addresses 0CH, 0DH, and 0EH). RDIV is set low when the RDI bit is set low
for five or ten consecutive multiframes as determined by the RDI10 bit
RFIV:
The RFIV bit indicates the remote failure indication status of tributary TU #1 in
the corresponding TUG2 when RDIZ7EN is set low. RFIV is set high when
the RFI bit in the V5 byte is set high for five or ten consecutive multiframes as
determined by the RDI10 bit in the RTOP and RTTB Configuration registers
(addresses 0CH, 0DH, and 0EH). RFIV is set low when the RFI bit is set low
for five or ten consecutive multiframes as determined by the RDI10 bit.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
158
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
ERDIV[2:0]:
The ERDIV[2:0] bits indicates the extended remote defect indication status of
tributary TU #1 in the corresponding TUG2 when RDIZ7EN is set high. The
ERDIV[2:0] bits are set to a new code when the same code in the extended
RDI bits of the Z7 byte is seen for five or ten consecutive multiframes as
determined by the RDI10 bit in the RTOP and RTTB Configuration registers
(addresses 0CH, 0DH, and 0EH).
PSLMV:
The PSLMV bit indicates the path signal mismatch status of tributary TU #1 in
the corresponding TUG2. PSLMV is set high when the accepted PSL differs
from the provisioned value. PSLMV is set low when the accepted PSL has
the same value as the provisioned one.
PSLUV:
The PSLUV bit indicates the path signal unstable status of tributary TU #1 in
the corresponding TUG2. The PSL unstable counter is incremented if the
PSL of the current multiframe differs form that in the previous multiframe. The
counter is cleared to zero when the same PSL is received for five consecutive
multiframes. The tributary PSL unstable alarm is asserted and PSLUV set
high when the unstable counter reaches five. The PSL unstable alarm is
negated and PSLUV set low when the unstable counter is cleared.
PDIVEN:
The PDIVEN bit modifies the payload defect indication status PDIV of
tributary TU #1 in the corresponding TUG2 . The PDIV output is set high
when the PSL in the V5 byte is set to the bit pattern specified by the
PDICODE[2:0] register bits for five consecutive multiframes. The PDIV
output is set low when the PSL is set to any other bit pattern for five
consecutive multiframes. When PDIVEN is set high, the PDIV output is
permanently set high independent of the tributary's defect status until the
PDIVEN is set low.
TUPTE:
The TUPTE bit determines the alarm conditions under which AIS is inserted
for tributary TU #1 in the corresponding TUG2. TUPTE is set high if tributary
TU #1 is to be terminated in the network element containing this TUPP-PLUS
device. In this case, tributary AIS is automatically inserted based on the
contents of the global Tributary Alarm AIS Control register (address 10H).
TUPTE is set low if tributary TU #1 is part of the through traffic in the network
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
159
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
element containing this TUPP-PLUS device. In this case, tributary AIS is only
inserted when a loss of pointer (LOP) or a loss of multiframe (LOM) alarm is
detected (as determined by the global Tributary Alarm AIS Control register).
RDIZ7EN:
The RDIZ7EN indicates which tributary path overhead byte is used for
controlling the ERDI[2:0] or RDI/RFI bits of tributary TU #1 in the
corresponding TUG2 . When RDIZ7EN is set low, the RDI and RFI bits in the
V5 byte are used to control the RDIV and RFIV register bits. When RDIZ7EN
is set high, the three bit extended RDI code in the Z7 byte is used to control
the ERDIV[2:0] register bits.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
160
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 10AH, 112H, 11AH, 122H, 12AH, 132H:
Register 20AH, 212H, 21AH, 222H, 22AH, 232H:
Register 30AH, 312H, 31AH, 322H, 32AH, 332H:
RTOP, TU #1 in TUG2 #2 to TUG2 #7, Expected Path Signal Label
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
Unused
X
Bit 2
R/W
EPSL[2]
0
Bit 1
R/W
EPSL[1]
0
Bit 0
R/W
EPSL[0]
0
This set of registers configures the expected path signal label of TU #1 in TUG2
#2 to TUG2 #7. These registers have no effect in TU3 mode.
EPSL[2:0]:
The EPSL[2:0] bits specifies the expected path signal label of tributary TU #1
in the corresponding TUG2. The expected PSL is compared with the
accepted PSL to determine the PSLM state.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
161
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 10BH, 113H, 11BH, 123H, 12BH, 133H:
Register 20BH, 213H, 21BH, 223H, 22BH, 233H:
Register 30BH, 313H, 31BH, 323H, 32BH, 333H:
RTOP, TU #1 in TUG2 #2 to TUG2 #7, Accepted Path Signal Label
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
Unused
X
Bit 2
R
APSL[2]
0
Bit 1
R
APSL[1]
0
Bit 0
R
APSL[0]
0
This set of registers reports the accepted path signal label of TU #1 in TUG2 #2
to TUG2 #7. These registers have no effect in TU3 mode.
APSL[2:0]:
The APSL[2:0] bits reports the accepted path signal label of tributary TU #1 in
the corresponding TUG2. An incoming PSL is accepted when the same value
is received for five consecutive multiframes.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
162
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 10CH, 114H, 11CH, 124H, 12CH, 134H:
Register 20CH, 214H, 21CH, 224H, 22CH, 234H:
Register 30CH, 314H, 31CH, 324H, 32CH, 334H:
RTOP, TU #1 in TUG2 #2 to TUG2 #7, BIP-2 Error Count LSB
Bit
Type
Function
Default
Bit 7
R
BIP[7]
X
Bit 6
R
BIP[6]
X
Bit 5
R
BIP[5]
X
Bit 4
R
BIP[4]
X
Bit 3
R
BIP[3]
X
Bit 2
R
BIP[2]
X
Bit 1
R
BIP[1]
X
Bit 0
R
BIP[0]
X
Register 10DH, 115H, 11DH, 125H, 12DH, 135H:
Register 20DH, 215H, 21DH, 225H, 22DH, 235H:
Register 30DH, 315H, 31DH, 325H, 32DH, 335H:
RTOP, TU #1 in TUG2 #2 to TUG2 #7, BIP-2 Error Count MSB
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
Unused
X
Bit 2
R
BIP[10]
X
Bit 1
R
BIP[9]
X
Bit 0
R
BIP[8]
X
These sets of registers report the number of block interleave parity (BIP-2) errors
detected in TU #1 in TUG2 #2 to TUG2 #7 in the previous accumulation interval.
These registers have no effect in TU3 mode. These registers do not saturate.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
163
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
BIP[10:0]:
The BIP[10:0] bits reports the number of tributary path bit-interleaved parity
errors that have been detected since the last time the BIP-2 registers were
polled. The BIP-2 registers are polled by writing to any of the Input Signal
Activity Monitor, Accumulate Trigger register. The write access transfers the
internally accumulated error count to the BIP-2 registers within 10 µs and
simultaneously resets the internal counter to begin a new cycle of error
accumulation. BIP-2 errors may be accumulated on a nibble basis or block
basis as controlled by the BLKBIP register bit.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
164
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 10EH, 116H, 11EH, 126H, 12EH, 136H:
Register 20EH, 216H, 21EH, 226H, 22EH, 236H:
Register 30EH, 316H, 31EH, 326H, 32EH, 336H:
TU #1 in TUG2 #2 to TUG2 #7, FEBE Error Count LSB
Bit
Type
Function
Default
Bit 7
R
FEBE[7]
X
Bit 6
R
FEBE[6]
X
Bit 5
R
FEBE[5]
X
Bit 4
R
FEBE[4]
X
Bit 3
R
FEBE[3]
X
Bit 2
R
FEBE[2]
X
Bit 1
R
FEBE[1]
X
Bit 0
R
FEBE[0]
X
Register 10FH, 117H, 11FH, 127H, 12FH, 137H:
Register 20FH, 217H, 21FH, 227H, 22FH, 237H:
Register 30FH, 317H, 31FH, 327H, 32FH, 337H:
TU #1 in TUG2 #2 to TUG2 #7, FEBE Error Count MSB
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
Unused
X
Bit 2
R
FEBE[10]
X
Bit 1
R
FEBE[9]
X
Bit 0
R
FEBE[8]
X
These registers reports the number of far end block errors (FEBE) detected in
TU #1 in TUG2 #2 to TUG2 #7 in the previous accumulation interval. These
registers have no effect in TU3 mode.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
165
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
FEBE[10:0]:
The FEBE[10:0] bits reports the number of tributary path far end block errors
that have been detected since the last time the FEBE registers were polled.
The FEBE registers are polled by applying by writing to the Input Signal
Activity Monitor, Accumulate Trigger register. The write access transfers the
internally accumulated error count to the FEBE registers within 10 µs and
simultaneously resets the internal counter to begin a new cycle of error
accumulation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
166
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 138H, 238H, 338H: RTOP, TU3 or TU #1 in TUG2 #1 to TUG2 #7,
COPSL Interrupt
Bit
Type
Function
Default
Bit 7
R/W
Reserved
0
Bit 6
R
COPSL7I
0
Bit 5
R
COPSL6I
0
Bit 4
R
COPSL5I
0
Bit 3
R
COPSL4I
0
Bit 2
R
COPSL3I
0
Bit 1
R
COPSL2I
0
Bit 0
R
COPSL1I
0
This register is used to identify and acknowledge change of path signal label
interrupts for the tributaries TU #1 in TUG2 #1 to TUG2 #7. It is also used to
identify and acknowledge TU3 change of path signal label interrupts.
COPSL1I:
The COPSL1I bit identifies the source of change of path signal label
interrupts. In TU3 mode, the COPSL1I bit reports and acknowledges COPSL
interrupts of the TU3 stream. Out of TU3 mode, the COPSL1I bit reports and
acknowledges COPSL interrupt of TU #1 in TUG2 #1. Interrupts are
generated when the accepted PSL changes. The COPSL1I bit is set high
when a change of PSL event occurs and are cleared immediately following a
read of this register, which also acknowledges and clears the interrupt.
COPSL1I remains valid when interrupts are not enabled (COPSLE set low)
and may be polled to detect change of path signal label events.
COPSL2I-COPSL7I:
The COPSL2I to COPSL7I bits identify the source of change of path signal
label interrupts. In TU3 mode, these bits are unused and will return a logic 0
when read. Out of TU3 mode, COPSL2I to COPSL7I bits report and
acknowledge COPSL interrupt of TU #1 in TUG2 #2 to TUG2 #7, respectively.
Interrupts are generated when the accepted PSL changes. An COPSL xI bit
is set high when a change of PSL event on the associated tributary (TU #1 in
TUG2 #x) occurs and are cleared immediately following a read of this
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
167
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
register, which also acknowledges and clears the interrupt. COPSLxI remains
valid when interrupts are not enabled (COPSLE set low) and may be polled to
detect change of path signal label events.
Reserved:
The Reserved bit must be written with a logic 0 for proper operation of the
TUPP-PLUS.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
168
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 139H, 239H, 339H: RTOP, TU3 or TU #1 in TUG2 #1 to TUG2 #7,
PSLM Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
PSLM7I
0
Bit 5
R
PSLM6I
0
Bit 4
R
PSLM5I
0
Bit 3
R
PSLM4I
0
Bit 2
R
PSLM3I
0
Bit 1
R
PSLM2I
0
Bit 0
R
PSLM1I
0
This register is used to identify and acknowledge path signal label mismatch
interrupts for the tributaries TU #1 in TUG2 #1 to TUG2 #7. It is also used to
identify and acknowledge TU3 path signal label mismatch interrupts.
PSLM1I:
The PSLM1I bit identifies the source of path signal label mismatch interrupts.
In TU3 mode, the PSLM1I bit reports and acknowledges PSLM interrupts of
the TU3 stream. Out of TU3 mode, the PSLM1I bit reports and acknowledges
PSLM interrupt of TU #1 in TUG2 #1. Interrupts are generated when the
accepted PSL becomes matched to the expected PSL or becomes
mismatched to the expected PSL. The PSLM1I bit is set high when a change
of in the PSL matched state occurs and are cleared immediately following a
read of this register, which also acknowledges and clears the interrupt.
PSLM1I remains valid when interrupts are not enabled (PSLME set low) and
may be polled to detect path signal label match/mismatch events.
PSLM1I-PSLM7I:
The PSLM1I to PSLM7I bits identify the source of path signal label mismatch
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. Out of TU3 mode, PSLM2I to PSLM7I bits report and acknowledge
PSLM interrupt of TU #1 in TUG2 #2 to TUG2 #7, respectively. Interrupts are
generated when the accepted PSL becomes matched to the expected PSL or
becomes mismatched to the expected PSL. An PSLM xI bit is set high when
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
169
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
a change of PSL matched state on the associated tributary (TU #1 in
TUG2 #x) occurs and are cleared immediately following a read of this
register, which also acknowledges and clears the interrupt. PSLMxI remains
valid when interrupts are not enabled (PSLME set low) and may be polled to
detect path signal label match/mismatch events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
170
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 13AH, 23AH, 33AH: RTOP, TU3 or TU #1 in TUG2 #1 to TUG2 #7,
PSLU Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
PSLU7I
0
Bit 5
R
PSLU6I
0
Bit 4
R
PSLU5I
0
Bit 3
R
PSLU4I
0
Bit 2
R
PSLU3I
0
Bit 1
R
PSLU2I
0
Bit 0
R
PSLU1I
0
This register is used to identify and acknowledge path signal label unstable
interrupts for the tributaries TU #1 in TUG2 #1 to TUG2 #7. It is also used to
identify and acknowledge TU3 path signal label unstable interrupts.
PSLU1I:
The PSLU1I bit identifies the source of path signal label unstable interrupts.
In TU3 mode, the PSLU1I bit reports and acknowledges PSLU interrupts of
the TU3 stream. Out of TU3 mode, the PSLU1I bit reports and acknowledges
PSLU interrupt of TU #1 in TUG2 #1. Interrupts are generated when the
received PSL becomes unstable or returns to stable. The PSLU1I bit is set
high when a change of in the PSL unstable state occurs and are cleared
immediately following a read of this register, which also acknowledges and
clears the interrupt. PSLU1I remains valid when interrupts are not enabled
(PSLUE set low) and may be polled to detect path signal label stable/unstable
events.
PSLU2I-PSLU7I:
The PSLU2I to PSLU7I bits identify the source of path signal label mismatch
interrupts. PSLU2I to PSLU7I bits report and acknowledge PSLU interrupt of
TU #1 in TUG2 #2 to TUG2 #7, respectively. Interrupts are generated when
the received PSL becomes unstable or returns to stable. An PSLU xI bit is set
high when a change of PSL unstable state on the associated tributary (TU #1
in TUG2 #x) occurs and are cleared immediately following a read of this
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
171
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
register, which also acknowledges and clears the interrupt. PSLUxI remains
valid when interrupts are not enabled (PSLUE set low) and may be polled to
detect path signal label stable/unstable events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
172
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 13BH, 23BH, 33BH: RTOP, TU3 or TU #1 in TUG2 #1 to TUG2 #7, RDI
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
RDI7I
0
Bit 5
R
RDI6I
0
Bit 4
R
RDI5I
0
Bit 3
R
RDI4I
0
Bit 2
R
RDI3I
0
Bit 1
R
RDI2I
0
Bit 0
R
RDI1I
0
This register is used to identify and acknowledge remote defect indication
interrupts for the tributaries TU #1 in TUG2 #1 to TUG2 #7. It is also used to
identify and acknowledge TU3 remote defect indication interrupts.
RDI1I:
The RDI1I bit identify the source of remote defect indication interrupts. In
TU3 mode, the RDI1I bit reports and acknowledges RDI interrupt of the TU3
stream. Out of TU3 mode, the RDI1I bit reports and acknowledges RDI
interrupt of TU #1 in TUG2 #1. Interrupts are generated when the received
RDI state changes. The RDI1I bit is set high when a change of RDI state
event occurs and are cleared immediately following a read of this register,
which also acknowledges and clears the interrupt. RDI1I remains valid when
interrupts are not enabled (RDIE set low) and may be polled to detect change
of remote defect indication events.
RDI2I-RDI7I:
The RDI2I to RDI7I bits identify the source of remote defect indication
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. Out of TU3 mode, the RDI2I to RDI7I bits report and acknowledge RDI
interrupt of TU #1 in TUG2 #2 to TUG2 #7, respectively. Interrupts are
generated when the received RDI state changes. An RDIxI bit is set high
when a change of RDI state on the associated tributary (TU #1 in TUG2 #x)
occurs and are cleared immediately following a read of this register, which
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
173
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
also acknowledges and clears the interrupt. RDIxI remains valid when
interrupts are not enabled (RDIE set low) and may be polled to detect change
of remote defect indication events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
174
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 13CH, 23CH, 33CH: RTOP, TU3 Auxiliary RDI Interrupt or TU #1 in
TUG2 #1 to TUG2 #7 RFI Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
RFI7I
0
Bit 5
R
RFI6I
0
Bit 4
R
RFI5I
0
Bit 3
R
RFI4I
0
Bit 2
R
RFI3I
0
Bit 1
R
RFI2I
0
Bit 0
R
RFI1I
0
This register is used to identify and acknowledge remote failure indication
interrupts for the tributaries TU #1 in TUG2 #1 to TUG2 #7. It is also used to
identify and acknowledge TU3 auxiliary remote defect indication interrupts.
RFI1I:
The RFI1I bit identify the source of remote defect indication interrupts. In TU3
mode, the RFI1I bit reports and acknowledges auxiliary RDI interrupt of the
TU3 stream. Out of TU3 mode, the RFI1I bit reports and acknowledges RFI
interrupt of TU #1 in TUG2 #1. Interrupts are generated when the received
RFI state changes. The RFI1I bit is set high when a change of RDI state
event occurs and are cleared immediately following a read of this register,
which also acknowledges and clears the interrupt. RFI1I remains valid when
interrupts are not enabled (RFIE set low) and may be polled to detect change
of remote defect indication events.
RFI2I-RFI7I:
The RFI2I to RFI7I bits identify the source of remote failure indication
interrupts. RFI1I to RFI7I bits report and acknowledge RFI interrupt of TU #1
in TUG2 #2 to TUG2 #7, respectively. Interrupts are generated when the
received RFI state changes. An RFIxI bit is set high when a change of RFI
state on the associated tributary (TU #1 in TUG2 #x) occurs and are cleared
immediately following a read of this register, which also acknowledges and
clears the interrupt. RFIxI remains valid when interrupts are not enabled
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
175
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
(RFIE set low) and may be polled to detect change of remote failure
indication events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
176
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 13DH, 23DH, 33DH: RTOP, TU3 or TU #1 in TUG2 #1 to TUG2 #7, In
Band Error Reporting Configuration
Bit
Type
Bit 7
Function
Default
Unused
x
Bit 6
R/W
IBER7
0
Bit 5
R/W
IBER6
0
Bit 4
R/W
IBER5
0
Bit 3
R/W
IBER4
0
Bit 2
R/W
IBER3
0
Bit 1
R/W
IBER2
0
Bit 0
R/W
IBER1
0
This register enables the inband error reporting mode of the tributaries TU #1 in
TUG2 #1 to TUG2 #7 and the IBER mode of the TU3 mode.
IBER1:
The IBER1 bit controls in band error reporting for tributary TU #1 in TUG2 #1
or TU3 in a TUG3. In TU3 mode, setting the IBER1 high causes in band error
reporting information to be inserted in the G1 byte of the TU3. In non-TU3
modes, setting the IBER1 bit high causes in band error reporting information
to be inserted in the V5 byte of tributary TU #1 of TUG2 #1. When the IBER1
bit is low, in band error reporting is disabled and the V5 byte of tributary
TU #1 of TUG2 #1 or the G1 byte of the TU3 is not modified.
IBER1-IBER7:
The IBER1 to IBER7 bits control in band error reporting for tributary TU #1 in
TUG2 #2 to TUG2 #7, respectively. Setting an IBERx bit high causes in band
error reporting information to be inserted in the V5 byte of tributary TU #1 of
the corresponding TUG2. When an IBER x bit is low, in band error reporting is
disabled and the V5 byte of tributary TU #1 of the corresponding TUG2 is not
modified.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
177
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 13EH, 23EH, 33EH: RTOP, TU3 or TU #1 in TUG2 #1 to TUG2 #7,
Controllable Output Configuration
Bit
Type
Bit 7
Function
Default
Unused
x
Bit 6
R/W
COUT7
0
Bit 5
R/W
COUT6
0
Bit 4
R/W
COUT5
0
Bit 3
R/W
COUT4
0
Bit 2
R/W
COUT3
0
Bit 1
R/W
COUT2
0
Bit 0
R/W
COUT1
0
This register controls the configurable output (COUT) output for the tributaries
TU #1 in TUG2 #1 to TUG2 #7and COUT output for the TU3 mode.
COUT1:
The COUT1 bit controls the COUT output for tributary TU #1 in TUG2 #1 or
TU3 in a TUG3. In TU3 mode, setting the COUT1 high will cause the COUT
output to be set high when the incoming data stream is part of the TU3 in a
TUG3. In non-TU3 modes, setting the COUT1 high will cause the COUT
output to be high when the incoming data stream is part of tributary TU #1 in
TUG2 #1. When COUT1 is set low, the COUT output will be low when the
incoming data stream is part of tributary TU #1 in TUG2 #1 or a TU3 in a
TUG3.
COUT2-COUT7:
The COUT2 to COUT7 bits control the COUT output for tributary TU #1 in
TUG2 #2 to TUG2 #7, respectively. Setting a COUTx bit high will force the
COUT output to be high when the incoming data stream is part of tributary
TU #1 of the corresponding TUG2. When an COUTx bit is low, the COUT
output will be low when the incoming data stream is part of tributary TU #1 of
the corresponding TUG2.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
178
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 140H, 148H, 150H, 158H, 160H, 168H, 170H:
Register 240H, 248H, 250H, 258H, 260H, 268H, 270H:
Register 340H, 348H, 350H, 358H, 360H, 368H, 370H:
RTOP, TU #2 in TUG2 #1 to TUG2 #7, Configuration
Bit
Type
Function
Default
Bit 7
R
CONFIG[1]
1
Bit 6
R
CONFIG[0]
1
Bit 5
R/W
BLKBIP
0
Bit 4
R/W
PSLUE
0
Bit 3
R/W
PSLME
0
Bit 2
R/W
COPSLE
0
Bit 1
R/W
RFIE
0
Bit 0
R/W
RDIE
0
This set of registers configures the operational modes of TU #2 in TUG2 #1 to
TUG2 #7. These registers have no effect in TU3 mode. When the corresponding
TUG2 tributary group is configured to TU2 (VT6) mode, the associated register in
this set has no effect.
RDIE:
The RDIE bit enables the remote defect indication interrupt for tributary TU #1
in the corresponding TUG2. When RDIE is set high, an interrupt is generated
upon changes of RDI status. Interrupts due to RDI status change are
masked when RDIE is set low. The RDI status is derived from bit 8 of the V5
byte when RDIZ7EN is set low and from bits 5 to 7 of the Z7 byte when
RDIZ7EN is set high.
RFIE:
The RFIE bit enables the remote failure indication interrupt for tributary TU #1
in the corresponding TUG2. When RDIZ7EN is set low, an interrupt is
generated upon assertion and negation events of the RFIV bit when RFIE is
set high. Interrupts due to RFIV status change are masked when RFIE is set
low. When RDIZ7EN is set high, RFIE is ignored. The RFIE bit is not used
when the RTOP is in TU3 mode is enabled.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
179
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
COPSLE:
The COPSLE bit enables the change of tributary path signal label interrupt for
tributary TU #2 in the corresponding TUG2. When COPSLE is set high, an
interrupt is generated when the accepted path signal label changes.
Interrupts due to change of PSL are masked when COPSLE is set low.
PSLME:
The PSLME bit enables the tributary path signal label mismatch interrupt for
tributary TU #2 in the corresponding TUG2. When PSLME is set high, an
interrupt is generated when the accepted path signal label changes from
mismatching the provisioned PSL to matching the provisioned value, or vice
versa. Interrupts due to PSL mismatch status change are masked when
PSLME is set low.
PSLUE:
The PSLUE bit enables the tributary path signal label unstable interrupt for
tributary TU #2 in the corresponding TUG2. When PSLUE is set high, an
interrupt is generated when the received path signal label becomes unstable
or returns to stable. Interrupts due to PSL unstable status change are
masked when PSLUE is set low.
BLKBIP:
The BLKBIP bit controls the accumulation of tributary BIP-2 errors for the
tributary TU #2 in the corresponding TUG2. When BLKBIP is set high, BIP-2
errors are counted on a block basis; the BIP error count is incremented by
one when one or both of the BIP-2 bits are in error. When BLKBIP is set low,
the BIP error count is incremented once for each BIP-2 bit that is in error.
CONFIG[1:0]:
The CONFIG[1:0] bits specify the tributary configuration of the corresponding
TUG2. The configuration specified by the CONFIG[1:0] bits are selected as
follows:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
180
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
CONFIG[1]
CONFIG[0]
Configuration
Active TU (VT)
0
0
TU2 (VT6)
#1
0
1
VT3
#1, #2
1
0
TU12 (VT2)
#1, #2, #3
1
1
TU11 (VT1.5)
#1, #2, #3, #4
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
181
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 141H, 149H, 151H, 159H, 161H, 169H, 171H:
Register 241H, 249H, 251H, 259H, 261H, 269H, 271H:
Register 341H, 349H, 351H, 359H, 361H, 369H, 371H:
RTOP, TU #2 in TUG2 #1 to TUG2 #7, Configuration and Alarm Status
Bit
Type
Function
Default
Bit 7
R/W
RDIZ7EN
0
Bit 6
R/W
TUPTE
0
Bit 5
R/W
PDIVEN
0
Bit 4
R
PSLUV
X
Bit 3
R
PSLMV
X
Bit 2
R
ERDIV[2]
X
Bit 1
R
ERDIV[1]/RFIV
X
Bit 0
R
ERDIV[0]/RDIV
X
This set of registers reports alarm status and configures TU #2 in TUG2 #1 to
TUG2 #7. These registers have no effect in TU3 mode. When the corresponding
TUG2 tributary group is configured to TU2 (VT6) mode, the associated register in
this set has no effect.
RDIV:
The RDIV bit indicates the remote defect indication status of tributary TU #2
in the corresponding TUG2 when RDIZ7EN is low. RDIV is set high when the
RDI bit in the V5 byte is set high for five or ten consecutive multiframes as
determined by the RDI10 bit in the RTOP and RTTB Configuration registers
(addresses 0CH, 0DH, and 0EH). RDIV is set low when the RDI bit is set low
for five or ten consecutive multiframes as determined by the RDI10 bit
RFIV:
The RFIV bit indicates the remote failure indication status of tributary TU #2 in
the corresponding TUG2 when RDIZ7EN is set low. RFIV is set high when
the RFI bit in the V5 byte is set high for five or ten consecutive multiframes as
determined by the RDI10 bit in the RTOP and RTTB Configuration registers
(addresses 0CH, 0DH, and 0EH). RFIV is set low when the RFI bit is set low
for five or ten consecutive multiframes as determined by the RDI10 bit.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
182
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
ERDIV[2:0]:
The ERDIV[2:0] bits indicates the extended remote defect indication status of
tributary TU #2 in the corresponding TUG2 when RDIZ7EN is set high. The
ERDIV[2:0] bits are set to a new code when the same code in the extended
RDI bits of the Z7 byte is seen for five or ten consecutive multiframes as
determined by the RDI10 bit in the RTOP and RTTB Configuration registers
(addresses 0CH, 0DH, and 0EH).
PSLMV:
The PSLMV bit indicates the path signal mismatch status of tributary TU #2 in
the corresponding TUG2. PSLMV is set high when the accepted PSL differs
from the provisioned value. PSLMV is set low when the accepted PSL has
the same value as the provisioned one.
PSLUV:
The PSLUV bit indicates the path signal unstable status of tributary TU #2 in
the corresponding TUG2. The PSL unstable counter is incremented if the
PSL of the current multiframe differs form that in the previous multiframe. The
counter is cleared to zero when the same PSL is received for five consecutive
multiframes. The tributary PSL unstable alarm is asserted and PSLUV set
high when the unstable counter reaches five. The PSL unstable alarm is
negated and PSLUV set low when the unstable counter is cleared.
PDIVEN:
The PDIVEN bit modifies the payload defect indication status PDIV of
tributary TU #2 in the corresponding TUG2 . The PDIV output is set high
when the PSL in the V5 byte is set to the bit pattern specified by the
PDICODE[2:0] input for five consecutive multiframes. The PDIV output is set
low when the PSL is set to any other bit pattern for five consecutive
multiframes. When PDIVEN is set high, the PDIV output is permanently set
high independent of the tributary's defect status until the PDIVEN is set low.
TUPTE:
The TUPTE bit determines the alarm conditions under which AIS is inserted
for tributary TU #2 in the corresponding TUG2. TUPTE is set high if tributary
TU #2 is to be terminated in the network element containing this TUPP-PLUS
device. In this case, tributary AIS is automatically inserted based on the
contents of the global Tributary Alarm AIS Control register (address 10H).
TUPTE is set low if tributary TU #2 is part of the through traffic in the network
element containing this TUPP-PLUS device. In this case, tributary AIS is only
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
183
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
inserted when a loss of pointer (LOP) or a loss of multiframe (LOM) alarm is
detected (as determined by the global Tributary Alarm AIS Control register).
RDIZ7EN:
The RDIZ7EN indicates which tributary path overhead byte is used for
controlling the ERDI[2:0] or RDI/RFI bits of tributary TU #2 in the
corresponding TUG2 . When RDIZ7EN is set low, the RDI and RFI bits in the
V5 byte are used to control the RDIV and RFIV register bits. When RDIZ7EN
is set high, the three bit extended RDI code in the Z7 byte is used to control
the ERDIV[2:0] register bits.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
184
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 142H, 14AH, 152H, 15AH, 162H, 16AH, 172H:
Register 242H, 24AH, 252H, 25AH, 262H, 26AH, 272H:
Register 342H, 34AH, 352H, 35AH, 362H, 36AH, 372H:
RTOP, TU #2 in TUG2 #1 to TUG2 #7, Expected Path Signal Label
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
Unused
X
Bit 2
R/W
EPSL[2]
0
Bit 1
R/W
EPSL[1]
0
Bit 0
R/W
EPSL[0]
0
This set of registers configures the expected path signal label of TU #2 in TUG2
#1 to TUG2 #7. These registers have no effect in TU3 mode. When the
corresponding TUG2 tributary group is configured to TU2 (VT6) mode, the
associated register in this set has no effect.
EPSL[2:0]:
The EPSL[2:0] bits specifies the expected path signal label of tributary TU #2
in the corresponding TUG2. The expected PSL is compared with the
accepted PSL to determine the PSLM state.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
185
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 143H, 14BH, 153H, 15BH, 163H, 16BH, 173H:
Register 243H, 24BH, 253H, 25BH, 263H, 26BH, 273H:
Register 343H, 34BH, 353H, 35BH, 363H, 36BH, 373H:
RTOP, TU #2 in TUG2 #1 to TUG2 #7, Accepted Path Signal Label
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
Unused
X
Bit 2
R
APSL[2]
0
Bit 1
R
APSL[1]
0
Bit 0
R
APSL[0]
0
This set of registers reports the accepted path signal label of TU #2 in TUG2 #1
to TUG2 #7. These registers have no effect in TU3 mode. When the
corresponding TUG2 tributary group is configured to TU2 (VT6) mode, the
associated register in this set has no effect.
APSL[2:0]:
The APSL[2:0] bits reports the accepted path signal label of tributary TU #2 in
TUG2 #1 to TUG2 #7. An incoming PSL is accepted when the same value is
received for five consecutive multiframes.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
186
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 144H, 14CH, 154H, 15CH, 164H, 16CH, 174H:
Register 244H, 24CH, 254H, 25CH, 264H, 26CH, 274H:
Register 344H, 34CH, 354H, 35CH, 364H, 36CH, 374H:
RTOP, TU #2 in TUG2 #1 to TUG2 #7, BIP-2 Error Count LSB
Bit
Type
Function
Default
Bit 7
R
BIP[7]
X
Bit 6
R
BIP[6]
X
Bit 5
R
BIP[5]
X
Bit 4
R
BIP[4]
X
Bit 3
R
BIP[3]
X
Bit 2
R
BIP[2]
X
Bit 1
R
BIP[1]
X
Bit 0
R
BIP[0]
X
Register 145H, 14DH, 155H, 15DH, 165H, 16DH, 175H:
Register 245H, 24DH, 255H, 25DH, 265H, 26DH, 275H:
Register 345H, 34DH, 355H, 35DH, 365H, 36DH, 375H:
RTOP, TU #2 in TUG2 #1 to TUG2 #7, BIP-2 Error Count MSB
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
Unused
X
Bit 2
R
BIP[10]
X
Bit 1
R
BIP[9]
X
Bit 0
R
BIP[8]
X
These registers reports the number of block interleave parity (BIP-2) errors
detected in TU #2 in TUG2 #1 to TUG2 #7 in the previous accumulation interval.
These registers contain invalid data in TU3 mode. When the corresponding
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
187
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
TUG2 tributary group is configured to TU2 (VT6) mode, the data in associated
registers are invalid. These registers do not saturate.
BIP[10:0]:
The BIP[10:0] bits reports the number of tributary path bit-interleaved parity
errors that have been detected since the last time the BIP-2 registers were
polled. The BIP-2 registers are polled by writing to the Input Signal Activity
Monitor, Accumulate Trigger register. The write access transfers the internally
accumulated error count to the BIP-2 registers within 10 µs and resets the
internal counter simultaneously to begin a new cycle of error accumulation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
188
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 146H, 14EH, 156H, 15EH, 166H, 16EH, 176H:
Register 246H, 24EH, 256H, 25EH, 266H, 26EH, 276H:
Register 346H, 34EH, 356H, 35EH, 366H, 36EH, 376H:
RTOP, TU #2 in TUG2 #1 to TUG2 #7, FEBE Error Count LSB
Bit
Type
Function
Default
Bit 7
R
FEBE[7]
X
Bit 6
R
FEBE[6]
X
Bit 5
R
FEBE[5]
X
Bit 4
R
FEBE[4]
X
Bit 3
R
FEBE[3]
X
Bit 2
R
FEBE[2]
X
Bit 1
R
FEBE[1]
X
Bit 0
R
FEBE[0]
X
Register 147H, 14FH, 157H, 15FH, 167H, 16FH, 177H:
Register 247H, 24FH, 257H, 25FH, 267H, 26FH, 277H:
Register 347H, 34FH, 357H, 35FH, 367H, 36FH, 377H:
RTOP, TU #2 in TUG2 #1 to TUG2 #7, FEBE Error Count MSB
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
Unused
X
Bit 2
R
FEBE[10]
X
Bit 1
R
FEBE[9]
X
Bit 0
R
FEBE[8]
X
These registers reports the number of far end block errors (FEBE) detected in TU
#2 in TUG2 #1 to TUG2 #7 in the previous accumulation interval. These registers
contain invalid data in TU3 mode. When the corresponding TUG2 tributary group
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
189
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
is configured to TU2 (VT6) mode, the associated registers in this set contain
invalid data.
FEBE[10:0]:
The FEBE[10:0] bits reports the number of tributary path far end block errors
that have been detected since the last time the FEBE registers were polled.
The FEBE registers are polled by writing to the Input Signal Activity Monitor,
Accumulate Trigger registers. The write access transfers the internally
accumulated error count to the FEBE registers within 10 µs and resets the
internal counter simultaneoulsy to begin a new cycle of error accumulation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
190
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 178H, 278H, 378H: RTOP, TU #2 in TUG2 #1 to TUG2 #7, COPSL
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
COPSL7I
0
Bit 5
R
COPSL6I
0
Bit 4
R
COPSL5I
0
Bit 3
R
COPSL4I
0
Bit 2
R
COPSL3I
0
Bit 1
R
COPSL2I
0
Bit 0
R
COPSL1I
0
This register is used to identify and acknowledge change of path signal label
interrupts for the tributaries TU #2 in TUG2 #1 to TUG2 #7.
COPSL1I-COPSL7I:
The COPSL1I to COPSL7I bits identify the source of change of path signal
label interrupts. In TU3 mode, these bits are unused and will return a logic 0
when read. When the corresponding TUG2 tributary group is configured for
TU2 (VT6) mode, the associated COPSLxI bit is unused and will return a
logic 0 when read. When operational, the COPSL1I to COPSL7I bits report
and acknowledge COPSL interrupt of TU #2 in TUG2 #1 to TUG2 #7,
respectively. Interrupts are generated when the accepted PSL changes. An
COPSLxI bit is set high when a change of PSL event on the associated
tributary (TU #2 in TUG2 #x) occurs and are cleared immediately following a
read of this register, which also acknowledges and clears the interrupt.
COPSLxI remains valid when interrupts are not enabled (COPSLE set low)
and may be polled to detect change of path signal label events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
191
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 179H, 279H, 379H: RTOP, TU #2 in TUG2 #1 to TUG2 #7, PSLM
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
PSLM7I
0
Bit 5
R
PSLM6I
0
Bit 4
R
PSLM5I
0
Bit 3
R
PSLM4I
0
Bit 2
R
PSLM3I
0
Bit 1
R
PSLM2I
0
Bit 0
R
PSLM1I
0
This register is used to identify and acknowledge path signal label mismatch
interrupts for the tributaries TU #2 in TUG2 #1 to TUG2 #7.
PSLM1I-PSLM7I:
The PSLM1I to PSLM7I bits identify the source of path signal label mismatch
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6) mode, the associated PSLMxI bit is unused and will return a logic 0
when read. When operational, the PSLM1I to PSLM7I bits report and
acknowledge PSLM interrupt of TU #2 in TUG2 #1 to TUG2 #7, respectively.
Interrupts are generated when the accepted PSL becomes matched to the
expected PSL or becomes mismatched to the expected PSL. An PSLM xI bit
is set high when a change of PSL matched state on the associated tributary
(TU #2 in TUG2 #x) occurs and are cleared immediately following a read of
this register, which also acknowledges and clears the interrupt. PSLM xI
remains valid when interrupts are not enabled (PSLME set low) and may be
polled to detect path signal label match/mismatch events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
192
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 17AH, 27AH, 37AH: RTOP, TU #2 in TUG2 #1 to TUG2 #7, PSLU
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
PSLU7I
0
Bit 5
R
PSLU6I
0
Bit 4
R
PSLU5I
0
Bit 3
R
PSLU4I
0
Bit 2
R
PSLU3I
0
Bit 1
R
PSLU2I
0
Bit 0
R
PSLU1I
0
This register is used to identify and acknowledge path signal label unstable
interrupts for the tributaries TU #2 in TUG2 #1 to TUG2 #7.
PSLU1I-PSLU7I:
The PSLU1I to PSLU7I bits identify the source of path signal label mismatch
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6) mode, the associated PSLUxI bit is unused and will return a logic 0
when read. When operational, the PSLU1I to PSLU7I bits report and
acknowledge PSLU interrupt of TU #2 in TUG2 #1 to TUG2 #7, respectively.
Interrupts are generated when the received PSL becomes unstable or returns
to stable. An PSLUxI bit is set high when a change of PSL unstable state on
the associated tributary (TU #2 in TUG2 #x) occurs and are cleared
immediately following a read of this register, which also acknowledges and
clears the interrupt. PSLUxI remains valid when interrupts are not enabled
(PSLUE set low) and may be polled to detect path signal label stable/unstable
events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
193
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 17BH, 27BH, 37BH: RTOP, TU #2 in TUG2 #1 to TUG2 #7, RDI
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
RDI7I
0
Bit 5
R
RDI6I
0
Bit 4
R
RDI5I
0
Bit 3
R
RDI4I
0
Bit 2
R
RDI3I
0
Bit 1
R
RDI2I
0
Bit 0
R
RDI1I
0
This register is used to identify and acknowledge remote defect indication
interrupts for the tributaries TU #2 in TUG2 #1 to TUG2 #7.
RDI1I-RDI7I:
The RDI1I to RDI7I bits identify the source of remote defect indication
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6) mode, the associated RDIxI bit is unused and will return a logic 0 when
read. When operational, the RDI1I to RDI7I bits report and acknowledge RDI
interrupt of TU #2 in TUG2 #1 to TUG2 #7, respectively. Interrupts are
generated when the received RDI state changes. An RDIxI bit is set high
when a change of RDI state on the associated tributary (TU #2 in TUG2 #x)
occurs and are cleared immediately following a read of this register, which
also acknowledges and clears the interrupt. RDIxI remains valid when
interrupts are not enabled (RDIE set low) and may be polled to detect change
of remote defect indication events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
194
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 17CH, 27CH, 37CH: RTOP, TU #2 in TUG2 #1 to TUG2 #7, RFI
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
RFI7I
0
Bit 5
R
RFI6I
0
Bit 4
R
RFI5I
0
Bit 3
R
RFI4I
0
Bit 2
R
RFI3I
0
Bit 1
R
RFI2I
0
Bit 0
R
RFI1I
0
This register is used to identify and acknowledge remote failure indication
interrupts for the tributaries TU #2 in TUG2 #1 to TUG2 #7.
RFI1I-RFI7I:
The RFI1I to RFI7I bits identify the source of remote failure indication
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6) mode, the associated RFIxI bit is unused and will return a logic 0 when
read. When operational, the RFI1I to RFI7I bits report and acknowledge RFI
interrupt of TU #2 in TUG2 #1 to TUG2 #7, respectively. Interrupts are
generated when the received RFI state changes. An RFIxI bit is set high
when a change of RFI state on the associated tributary (TU #2 in TUG2 #x)
occurs and are cleared immediately following a read of this register, which
also acknowledges and clears the interrupt. RFIxI remains valid when
interrupts are not enabled (RFIE set low) and may be polled to detect change
of remote failure indication events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
195
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 17DH, 27DH, 37DH: RTOP, TU #2 in TUG2 #1 to TUG2 #7, In Band
Error Reporting Configuration
Bit
Type
Bit 7
Function
Default
Unused
x
Bit 6
R/W
IBER7
0
Bit 5
R/W
IBER6
0
Bit 4
R/W
IBER5
0
Bit 3
R/W
IBER4
0
Bit 2
R/W
IBER3
0
Bit 1
R/W
IBER2
0
Bit 0
R/W
IBER1
0
This register enables the inband error reporting mode for the tributaries TU #2 in
TUG2 #1 to TUG2 #7.
IBER1-IBER7:
The IBER1 to IBER7 bits control in band error reporting for tributary TU #2 in
TUG2 #1 to TUG2 #7, respectively. Setting an IBERx bit high causes in band
error reporting information to be inserted in the V5 byte of tributary TU #2 of
the corresponding TUG2. When an IBER x bit is low, in band error reporting is
disabled and the V5 byte of tributary TU #2 of the corresponding TUG2 is not
modified.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
196
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 17EH, 27EH, 37EH: TU #2 in TUG2 #1 to TUG2 #7, Controllable
Output Configuration
Bit
Type
Bit 7
Function
Default
Unused
x
Bit 6
R/W
COUT7
0
Bit 5
R/W
COUT6
0
Bit 4
R/W
COUT5
0
Bit 3
R/W
COUT4
0
Bit 2
R/W
COUT3
0
Bit 1
R/W
COUT2
0
Bit 0
R/W
COUT1
0
This register controls the COUT output for the tributaries TU #2 in TUG2 #1 to
TUG2 #7.
COUT1-COUT7:
The COUT1 to COUT7 bits control the COUT output for tributary TU #2 in
TUG2 #1 to TUG2 #7, respectively. Setting a COUTx bit high will force the
COUT output to be high when the incoming data stream is part of tributary
TU #2 of the corresponding TUG2. When an COUTx bit is low, the COUT
output will be low when the incoming data stream is part of tributary TU #2 of
the corresponding TUG2.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
197
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 180H, 188H, 190H, 198H, 1A0H, 1A8H, 1B0H:
Register 280H, 288H, 290H, 298H, 2A0H, 2A8H, 2B0H:
Register 380H, 388H, 390H, 398H, 3A0H, 3A8H, 3B0H:
RTOP, TU #3 in TUG2 #1 to TUG2 #7, Configuration
Bit
Type
Function
Default
Bit 7
R
CONFIG[1]
1
Bit 6
R
CONFIG[0]
1
Bit 5
R/W
BLKBIP
0
Bit 4
R/W
PSLUE
0
Bit 3
R/W
PSLME
0
Bit 2
R/W
COPSLE
0
Bit 1
R/W
RFIE
0
Bit 0
R/W
RDIE
0
This set of registers configures the operational modes of TU #3 in TUG2 #1 to
TUG2 #7. These registers have no effect in TU3 mode. When the corresponding
TUG2 tributary group is configured to TU2 (VT6) or VT3 mode, the associated
register in this set has no effect.
RDIE:
The RDIE bit enables the remote defect indication interrupt for tributary TU #1
in the corresponding TUG2. When RDIE is set high, an interrupt is generated
upon changes of RDI status. Interrupts due to RDI status change are
masked when RDIE is set low. The RDI status is derived from bit 8 of the V5
byte when RDIZ7EN is set low and from bits 5 to 7 of the Z7 byte when
RDIZ7EN is set high.
RFIE:
The RFIE bit enables the remote failure indication interrupt for tributary TU #1
in the corresponding TUG2. When RDIZ7EN is set low, an interrupt is
generated upon assertion and negation events of the RFIV bit when RFIE is
set high. Interrupts due to RFIV status change are masked when RFIE is set
low. When RDIZ7EN is set high, RFIE is ignored. The RFIE bit is not used
when the RTOP is in TU3 mode is enabled.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
198
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
COPSLE:
The COPSLE bit enables the change of tributary path signal label interrupt for
tributary TU #3 in the corresponding TUG2. When COPSLE is set high, an
interrupt is generated when the accepted path signal label changes.
Interrupts due to change of PSL are masked when COPSLE is set low.
PSLME:
The PSLME bit enables the tributary path signal label mismatch interrupt for
tributary TU #3 in the corresponding TUG2. When PSLME is set high, an
interrupt is generated when the accepted path signal label changes from
mismatching the provisioned PSL to matching the provisioned value, or vice
versa. Interrupts due to PSL mismatch status change are masked when
PSLME is set low.
PSLUE:
The PSLUE bit enables the tributary path signal label unstable interrupt for
tributary TU #3 in the corresponding TUG2. When PSLUE is set high, an
interrupt is generated when the received path signal label becomes unstable
or returns to stable. Interrupts due to PSL unstable status change are
masked when PSLUE is set low.
BLKBIP:
The BLKBIP bit controls the accumulation of tributary BIP-2 errors for the
tributary TU #3 in the corresponding TUG2. When BLKBIP is set high, BIP-2
errors are counted on a block basis; the BIP error count is incremented by
one when one or both of the BIP-2 bits are in error. When BLKBIP is set low,
the BIP error count is incremented once for each BIP-2 bit that is in error.
CONFIG[1:0]:
The CONFIG[1:0] bits specify the tributary configuration of the corresponding
TUG2. The configuration specified by the CONFIG[1:0] bits are selected as
follows:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
199
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
CONFIG[1]
CONFIG[0]
Configuration
Active TU (VT)
0
0
TU2 (VT6)
#1
0
1
VT3
#1, #2
1
0
TU12 (VT2)
#1, #2, #3
1
1
TU11 (VT1.5)
#1, #2, #3, #4
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
200
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 181H, 189H, 191H, 199H, 1A1H, 1A9H, 1B1H:
Register 281H, 289H, 291H, 299H, 2A1H, 2A9H, 2B1H:
Register 381H, 389H, 391H, 399H, 3A1H, 3A9H, 3B1H:
RTOP, TU #3 in TUG2 #1 to TUG2 #7, Configuration and Alarm Status
Bit
Type
Function
Default
Bit 7
R/W
RDIZ7EN
0
Bit 6
R/W
TUPTE
0
Bit 5
R/W
PDIVEN
0
Bit 4
R
PSLUV
X
Bit 3
R
PSLMV
X
Bit 2
R
ERDIV[2]
X
Bit 1
R
ERDIV[1]/RFIV
X
Bit 0
R
ERDIV[0]/RDIV
X
This set of registers reports alarm status and configures TU #3 in TUG2 #1 to
TUG2 #7. These registers have no effect in TU3 mode. When the corresponding
TUG2 tributary group is configured to TU2 (VT6) or VT3 mode, the associated
register in this set has no effect.
RDIV:
The RDIV bit indicates the remote defect indication status of tributary TU #3
in the corresponding TUG2 when RDIZ7EN is low. RDIV is set high when the
RDI bit in the V5 byte is set high for five or ten consecutive multiframes as
determined by the RDI10 bit in the RTOP and RTTB Configuration registers
(addresses 0CH, 0DH, and 0EH). RDIV is set low when the RDI bit is set low
for five or ten consecutive multiframes as determined by the RDI10 bit
RFIV:
The RFIV bit indicates the remote failure indication status of tributary TU #3 in
the corresponding TUG2 when RDIZ7EN is set low. RFIV is set high when
the RFI bit in the V5 byte is set high for five or ten consecutive multiframes as
determined by the RDI10 bit in the RTOP and RTTB Configuration registers
(addresses 0CH, 0DH, and 0EH). RFIV is set low when the RFI bit is set low
for five or ten consecutive multiframes as determined by the RDI10 bit.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
201
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
ERDIV[2:0]:
The ERDIV[2:0] bits indicates the extended remote defect indication status of
tributary TU #3 in the corresponding TUG2 when RDIZ7EN is set high. The
ERDIV[2:0] bits are set to a new code when the same code in the extended
RDI bits of the Z7 byte is seen for five or ten consecutive multiframes as
determined by the RDI10 bit in the RTOP and RTTB Configuration registers
(addresses 0CH, 0DH, and 0EH).
PSLMV:
The PSLMV bit indicates the path signal mismatch status of tributary TU #3 in
the corresponding TUG2. PSLMV is set high when the accepted PSL differs
from the provisioned value. PSLMV is set low when the accepted PSL has
the same value as the provisioned one.
PSLUV:
The PSLUV bit indicates the path signal unstable status of tributary TU #3 in
the corresponding TUG2. The PSL unstable counter is incremented if the
PSL of the current multiframe differs form that in the previous multiframe. The
counter is cleared to zero when the same PSL is received for five consecutive
multiframes. The tributary PSL unstable alarm is asserted and PSLUV set
high when the unstable counter reaches five. The PSL unstable alarm is
negated and PSLUV set low when the unstable counter is cleared.
PDIVEN:
The PDIVEN bit modifies the payload defect indication status PDIV of
tributary TU #3 in the corresponding TUG2 . The PDIV output is set high
when the PSL in the V5 byte is set to the bit pattern specified by the
PDICODE[2:0] input for five consecutive multiframes. The PDIV output is set
low when the PSL is set to any other bit pattern for five consecutive
multiframes. When PDIVEN is set high, the PDIV output is permanently set
high independent of the tributary's defect status until the PDIVEN is set low.
TUPTE:
The TUPTE bit determines the alarm conditions under which AIS is inserted
for tributary TU #3 in the corresponding TUG2. TUPTE is set high if tributary
TU #3 is to be terminated in the network element containing this TUPP-PLUS
device. In this case, tributary AIS is automatically inserted based on the
contents of the global Tributary Alarm AIS Control register (address 10H).
TUPTE is set low if tributary TU #3 is part of the through traffic in the network
element containing this TUPP-PLUS device. In this case, tributary AIS is only
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
202
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
inserted when a loss of pointer (LOP) or a loss of multiframe (LOM) alarm is
detected (as determined by the global Tributary Alarm AIS Control register).
RDIZ7EN:
The RDIZ7EN indicates which tributary path overhead byte is used for
controlling the ERDI[2:0] or RDI/RFI bits of tributary TU #3 in the
corresponding TUG2 . When RDIZ7EN is set low, the RDI and RFI bits in the
V5 byte are used to control the RDIV and RFIV register bits. When RDIZ7EN
is set high, the three bit extended RDI code in the Z7 byte is used to control
the ERDIV[2:0] register bits.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
203
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 182H, 18AH, 192H, 19AH, 1A2H, 1AAH, 1B2H:
Register 282H, 28AH, 292H, 29AH, 2A2H, 2AAH, 2B2H:
Register 382H, 38AH, 392H, 39AH, 3A2H, 3AAH, 3B2H:
RTOP, TU #3 in TUG2 #1 to TUG2 #7, Expected Path Signal Label
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
Unused
X
Bit 2
R/W
EPSL[2]
0
Bit 1
R/W
EPSL[1]
0
Bit 0
R/W
EPSL[0]
0
This set of registers configures the expected the path signal label of TU #3 in
TUG2 #1 to TUG2 #7. These registers have no effect in TU3 mode. When the
corresponding TUG2 tributary group is configured to TU2 (VT6) or VT3 mode, the
associated register in this set has no effect.
EPSL[2:0]:
The EPSL[2:0] bits specifies the expected path signal label of tributary TU #3
in the corresponding TUG2. The expected PSL is compared with the
accepted PSL to determine the PSLM state.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
204
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 183H, 18BH, 193H, 19BH, 1A3H, 1ABH, 1B3H:
Register 283H, 28BH, 293H, 29BH, 2A3H, 2ABH, 2B3H:
Register 383H, 38BH, 393H, 39BH, 3A3H, 3ABH, 3B3H:
RTOP, TU #3 in TUG2 #1 to TUG2 #7, Accepted Path Signal Label
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
Unused
X
Bit 2
R
APSL[2]
0
Bit 1
R
APSL[1]
0
Bit 0
R
APSL[0]
0
This set of registers reports the accepted the path signal label of TU #3 in TUG2
#1 to TUG2 #7. These registers have no effect in TU3 mode. When the
corresponding TUG2 tributary group is configured to TU2 (VT6) or VT3 mode, the
associated register in this set has no effect.
APSL[2:0]:
The APSL[2:0] bits reports the accepted path signal label of tributary TU #3 in
the corresponding TUG2. An incoming PSL is accepted when the same value
is received for five consecutive multiframes.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
205
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 184H, 18CH, 194H, 19CH, 1A4H, 1ACH, 1B4H:
Register 284H, 28CH, 294H, 29CH, 2A4H, 2ACH, 2B4H:
Register 384H, 38CH, 394H, 39CH, 3A4H, 3ACH, 3B4H:
RTOP, TU #3 in TUG2 #1 to TUG2 #7, BIP-2 Error Count LSB
Bit
Type
Function
Default
Bit 7
R
BIP[7]
X
Bit 6
R
BIP[6]
X
Bit 5
R
BIP[5]
X
Bit 4
R
BIP[4]
X
Bit 3
R
BIP[3]
X
Bit 2
R
BIP[2]
X
Bit 1
R
BIP[1]
X
Bit 0
R
BIP[0]
X
Register 185H, 18DH, 195H, 19DH, 1A5H, 1ADH, 1B5H:
Register 285H, 28DH, 295H, 29DH, 2A5H, 2ADH, 2B5H:
Register 385H, 38DH, 395H, 39DH, 3A5H, 3ADH, 3B5H:
RTOP, TU #3 in TUG2 #1 to TUG2 #7, BIP-2 Error Count MSB
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
Unused
X
Bit 2
R
BIP[10]
X
Bit 1
R
BIP[9]
X
Bit 0
R
BIP[8]
X
These registers reports the number of block interleave parity (BIP-2) errors
detected in TU #3 in TUG2 #1 to TUG2 #7 in the previous accumulation interval.
These registers contain invalid data in TU3 mode. When the corresponding
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
206
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
TUG2 tributary group is configured to TU2 (VT6) or VT3 mode, the data in the
associated registers are invalid. These registers do not saturate.
BIP[10:0]:
The BIP[10:0] bits reports the number of tributary path bit-interleaved parity
errors that have been detected since the last time the BIP-2 registers were
polled. The BIP-2 registers are polled by writing to the Input Signal Activity
Monitor, Accumulate Trigger register. The write access transfers the internally
accumulated error count to the BIP-2 registers within 10 µs and resets the
internal counter simultaneously to begin a new cycle of error accumulation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
207
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 186H, 18EH, 196H, 19EH, 1A6H, 1AEH, 1B6H:
Register 286H, 28EH, 296H, 29EH, 2A6H, 2AEH, 2B6H:
Register 386H, 38EH, 396H, 39EH, 3A6H, 3AEH, 3B6H:
TU #3 in TUG2 #1 to TUG2 #7, FEBE Error Count LSB
Bit
Type
Function
Default
Bit 7
R
FEBE[7]
X
Bit 6
R
FEBE[6]
X
Bit 5
R
FEBE[5]
X
Bit 4
R
FEBE[4]
X
Bit 3
R
FEBE[3]
X
Bit 2
R
FEBE[2]
X
Bit 1
R
FEBE[1]
X
Bit 0
R
FEBE[0]
X
Register 187H, 18FH, 197H, 19FH, 1A7H, 1AFH, 1B7H:
Register 287H, 28FH, 297H, 29FH, 2A7H, 2AFH, 2B7H:
Register 387H, 38FH, 397H, 39FH, 3A7H, 3AFH, 3B7H:
RTOP, TU #3 in TUG2 #1 to TUG2 #7, FEBE Error Count MSB
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
Unused
X
Bit 2
R
FEBE[10]
X
Bit 1
R
FEBE[9]
X
Bit 0
R
FEBE[8]
X
These registers reports the number of far end block errors (FEBE) detected in TU
#3 in TUG2 #1 to TUG2 #7 in the previous accumulation interval. These registers
contain invaild data in TU3 mode. When the corresponding TUG2 tributary group
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
208
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
is configured to TU2 (VT6) or VT3 mode, the associated registers in this set
contain invalid data.
FEBE[10:0]:
The FEBE[10:0] bits reports the number of tributary path far end block errors
that have been detected since the last time the FEBE registers were polled.
The FEBE registers are polled by writing to the Input Signal Activity Monitor,
Accumulate Trigger register. The write access transfers the internally
accumulated error count to the FEBE registers within 10 µs and resets the
internal counter simultaneously to begin a new cycle of error accumulation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
209
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1B8H, 2B8H, 3B8H: RTOP, TU #3 in TUG2 #1 to TUG2 #7, COPSL
Interrupt
Bit
Type
Bit 7
Function
Default
Reserved
X
Bit 6
R
COPSL7I
0
Bit 5
R
COPSL6I
0
Bit 4
R
COPSL5I
0
Bit 3
R
COPSL4I
0
Bit 2
R
COPSL3I
0
Bit 1
R
COPSL2I
0
Bit 0
R
COPSL1I
0
This register is used to identify and acknowledge change of path signal label
interrupts for the tributaries TU #3 in TUG2 #1 TO TUG2 #7.
COPSL1I-COPSL7I:
The COPSL1I to COPSL7I bits identify the source of change of path signal
label interrupts. In TU3 mode, these bits are unused and will return a logic 0
when read. When the corresponding TUG2 tributary group is configured for
TU2 (VT6) or VT3 mode, the associated COPSLxI bit is unused and will
return a logic 0 when read. When operational, the COPSL1I to COPSL7I bits
report and acknowledge COPSL interrupt of TU #3 in TUG2 #1 to TUG2 #7,
respectively. Interrupts are generated when the accepted PSL changes. An
COPSLxI bit is set high when a change of PSL event on the associated
tributary (TU #3 in TUG2 #x) occurs and are cleared immediately following a
read of this register, which also acknowledges and clears the interrupt.
COPSLxI remains valid when interrupts are not enabled (COPSLE set low)
and may be polled to detect change of path signal label events.
Reserved:
The Reserved bits must be written with a logic 0 for proper operation of the
TUPP-PLUS.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
210
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1B9H, 2B9H, 3B9H: RTOP, TU #3 in TUG2 #1 to TUG2 #7, PSLM
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
PSLM7I
0
Bit 5
R
PSLM6I
0
Bit 4
R
PSLM5I
0
Bit 3
R
PSLM4I
0
Bit 2
R
PSLM3I
0
Bit 1
R
PSLM2I
0
Bit 0
R
PSLM1I
0
This register is used to identify and acknowledge path signal label mismatch
interrupts for the tributaries TU #3 in TUG2 #1 TO TUG2 #7.
PSLM1I-PSLM7I:
The PSLM1I to PSLM7I bits identify the source of path signal label mismatch
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6) or VT3 mode, the associated PSLMxI bit is unused and will return a
logic 0 when read. When operational, the PSLM1I to PSLM7I bits report and
acknowledge PSLM interrupt of TU #3 in TUG2 #1 to TUG2 #7, respectively.
Interrupts are generated when the accepted PSL becomes matched to the
expected PSL or becomes mismatched to the expected PSL. An PSLM xI bit
is set high when a change of PSL matched state on the associated tributary
(TU #3 in TUG2 #x) occurs and are cleared immediately following a read of
this register, which also acknowledges and clears the interrupt. PSLM xI
remains valid when interrupts are not enabled (PSLME set low) and may be
polled to detect path signal label match/mismatch events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
211
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1BAH, 2BAH, 3BAH: RTOP, TU #3 in TUG2 #1 to TUG2 #7, PSLU
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
PSLU7I
0
Bit 5
R
PSLU6I
0
Bit 4
R
PSLU5I
0
Bit 3
R
PSLU4I
0
Bit 2
R
PSLU3I
0
Bit 1
R
PSLU2I
0
Bit 0
R
PSLU1I
0
This register is used to identify and acknowledge path signal label unstable
interrupts for the tributaries TU #3 in TUG2 #1 TO TUG2 #7.
PSLU1I-PSLU7I:
The PSLU1I to PSLU7I bits identify the source of path signal label mismatch
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6) or VT3 mode, the associated PSLUxI bit is unused and will return a
logic 0 when read. When operational, the PSLU1I to PSLU7I bits report and
acknowledge PSLU interrupt of TU #3 in TUG2 #1 to TUG2 #7, respectively.
Interrupts are generated when the received PSL becomes unstable or returns
to stable. An PSLUxI bit is set high when a change of PSL unstable state on
the associated tributary (TU #3 in TUG2 #x) occurs and are cleared
immediately following a read of this register, which also acknowledges and
clears the interrupt. PSLUxI remains valid when interrupts are not enabled
(PSLUE set low) and may be polled to detect path signal label stable/unstable
events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
212
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1BBH, 2BBH, 3BBH: RTOP, TU #3 in TUG2 #1 to TUG2 #7, RDI
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
RDI7I
0
Bit 5
R
RDI6I
0
Bit 4
R
RDI5I
0
Bit 3
R
RDI4I
0
Bit 2
R
RDI3I
0
Bit 1
R
RDI2I
0
Bit 0
R
RDI1I
0
This register is used to identify and acknowledge remote defect indication
interrupts for the tributaries TU #3 in TUG2 #1 TO TUG2 #7.
RDI1I-RDI7I:
The RDI1I to RDI7I bits identify the source of remote defect indication
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6) or VT3 mode, the associated RDIxI bit is unused and will return a logic
0 when read. When operational, the RDI1I to RDI7I bits report and
acknowledge RDI interrupt of TU #3 in TUG2 #1 to TUG2 #7, respectively.
Interrupts are generated when the received RDI state changes. An RDIxI bit
is set high when a change of RDI state on the associated tributary (TU #3 in
TUG2 #x) occurs and are cleared immediately following a read of this
register, which also acknowledges and clears the interrupt. RDIxI remains
valid when interrupts are not enabled (RDIE set low) and may be polled to
detect change of remote defect indication events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
213
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1BCH, 2BCH, 3BCH: RTOP, TU #3 in TUG2 #1 to TUG2 #7, RFI
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
RFI7I
0
Bit 5
R
RFI6I
0
Bit 4
R
RFI5I
0
Bit 3
R
RFI4I
0
Bit 2
R
RFI3I
0
Bit 1
R
RFI2I
0
Bit 0
R
RFI1I
0
This register is used to identify and acknowledge remote failure indication
interrupts for the tributaries TU #3 in TUG2 #1 TO TUG2 #7.
RFI1I-RFI7I:
The RFI1I to RFI7I bits identify the source of remote failure indication
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6) or VT3 mode, the associated RFIxI bit is unused and will return a logic
0 when read. When operational, the RFI1I to RFI7I bits report and
acknowledge RFI interrupt of TU #3 in TUG2 #1 to TUG2 #7, respectively.
Interrupts are generated when the received RFI state changes. An RFIxI bit
is set high when a change of RFI state on the associated tributary (TU #3 in
TUG2 #x) occurs and are cleared immediately following a read of this
register, which also acknowledges and clears the interrupt. RFIxI remains
valid when interrupts are not enabled (RFIE set low) and may be polled to
detect change of remote failure indication events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
214
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1BDH, 2BDH, 3BDH: RTOP, TU #3 in TUG2 #1 to TUG2 #7, In Band
Error Reporting Configuration
Bit
Type
Bit 7
Function
Default
Unused
x
Bit 6
R/W
IBER7
0
Bit 5
R/W
IBER6
0
Bit 4
R/W
IBER5
0
Bit 3
R/W
IBER4
0
Bit 2
R/W
IBER3
0
Bit 1
R/W
IBER2
0
Bit 0
R/W
IBER1
0
This register enables the inband error reporting mode for the tributaries TU #3 in
TUG2 #1 to TUG2 #7.
IBER1-IBER7:
The IBER1 to IBER7 bits control in band error reporting for tributary TU #3 in
TUG2 #1 to TUG2 #7, respectively. Setting an IBERx bit high causes in band
error reporting information to be inserted in the V5 byte of tributary TU #3 of
the corresponding TUG2. When an IBER x bit is low, in band error reporting is
disabled and the V5 byte of tributary TU #3 of the corresponding TUG2 is not
modified.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
215
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1BEH, 2BEH, 3BEH: RTOP, TU #3 in TUG2 #1 to TUG2 #7,
Controllable Output Configuration
Bit
Type
Bit 7
Function
Default
Unused
x
Bit 6
R/W
COUT7
0
Bit 5
R/W
COUT6
0
Bit 4
R/W
COUT5
0
Bit 3
R/W
COUT4
0
Bit 2
R/W
COUT3
0
Bit 1
R/W
COUT2
0
Bit 0
R/W
COUT1
0
This register controls the COUT output for the tributaries TU #3 in TUG2 #1 to
TUG2 #7.
COUT1-COUT7:
The COUT1 to COUT7 bits control the COUT output for tributary TU #3 in
TUG2 #1 to TUG2 #7, respectively. Setting a COUTx bit high will force the
COUT output to be high when the incoming data stream is part of tributary
TU #3 of the corresponding TUG2. When an COUTx bit is low, the COUT
output will be low when the incoming data stream is part of tributary TU #3 of
the corresponding TUG2.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
216
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1C0H, 1C8H, 1D0H, 1D8H, 1E0H, 1E8H, 1F0H:
Register 2C0H, 2C8H, 2D0H, 2D8H, 2E0H, 2E8H, 2F0H:
Register 3C0H, 3C8H, 3D0H, 3D8H, 3E0H, 3E8H, 3F0H:
RTOP, TU #4 in TUG2 #1 to TUG2 #7, Configuration
Bit
Type
Function
Default
Bit 7
R
CONFIG[1]
1
Bit 6
R
CONFIG[0]
1
Bit 5
R/W
BLKBIP
0
Bit 4
R/W
PSLUE
0
Bit 3
R/W
PSLME
0
Bit 2
R/W
COPSLE
0
Bit 1
R/W
RFIE
0
Bit 0
R/W
RDIE
0
This set of registers configures the operational modes of TU #4 in TUG2 #1 to
TUG2 #7. These registers have no effect in TU3 mode. When the corresponding
TUG2 tributary group is configured to TU2 (VT6), VT3 or TU12 (VT2) mode, the
associated register in this set has no effect.
RDIE:
The RDIE bit enables the remote defect indication interrupt for tributary TU #4
in the corresponding TUG2. When RDIZ7EN is set low, an interrupt is
generated upon assertion and negation events of the RDIV bit when RDIE is
set high. Interrupts due to RDIV status change are masked when RDIE is set
low.
When RDIZ7EN is set high, an interrupt is generated upon assertion or
negation events of the ERDIV[2:0] bits when RDIE is set high. Interrupts due
to ERDIV[2:0] status change are masked when RDIE is set low.
COPSLE:
The COPSLE bit enables the change of tributary path signal label interrupt for
tributary TU #4 in the corresponding TUG2. When COPSLE is set high, an
interrupt is generated when the accepted path signal label changes.
Interrupts due to change of PSL are masked when COPSLE is set low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
217
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
PSLME:
The PSLME bit enables the tributary path signal label mismatch interrupt for
tributary TU #4 in the corresponding TUG2. When PSLME is set high, an
interrupt is generated when the accepted path signal label changes from
mismatching the provisioned PSL to matching the provisioned value, or vice
versa. Interrupts due to PSL mismatch status change are masked when
PSLME is set low.
PSLUE:
The PSLUE bit enables the tributary path signal label unstable interrupt for
tributary TU #4 in the corresponding TUG2. When PSLUE is set high, an
interrupt is generated when the received path signal label becomes unstable
or returns to stable. Interrupts due to PSL unstable status change are
masked when PSLUE is set low.
BLKBIP:
The BLKBIP bit controls the accumulation of tributary BIP-2 errors for the
tributary TU #4 in the corresponding TUG2. When BLKBIP is set high, BIP-2
errors are counted on a block basis; the BIP error count is incremented by
one when one or both of the BIP-2 bits are in error. When BLKBIP is set low,
the BIP error count is incremented once for each BIP-2 bit that is in error.
CONFIG[1:0]:
The CONFIG[1:0] bits specify the tributary configuration of the corresponding
TUG2. The configuration specified by the CONFIG[1:0] bits are selected as
follows:
CONFIG[1]
CONFIG[0]
Configuration
Active TU (VT)
0
0
TU2 (VT6)
#1
0
1
VT3
#1, #2
1
0
TU12 (VT2)
#1, #2, #3
1
1
TU11 (VT1.5)
#1, #2, #3, #4
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
218
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1C1H, 1C9H, 1D1H, 1D9H, 1E1H, 1E9H, 1F1H:
Register 2C1H, 2C9H, 2D1H, 2D9H, 2E1H, 2E9H, 2F1H:
Register 3C1H, 3C9H, 3D1H, 3D9H, 3E1H, 3E9H, 3F1H:
RTOP, TU #4 in TUG2 #1 to TUG2 #7, Configuration and Alarm Status
Bit
Type
Function
Default
Bit 7
R/W
RDIZ7EN
0
Bit 6
R/W
TUPTE
0
Bit 5
R/W
PDIVEN
0
Bit 4
R
PSLUV
X
Bit 3
R
PSLMV
X
Bit 2
R
ERDIV[2]
X
Bit 1
R
ERDIV[1]/RFIV
X
Bit 0
R
ERDIV[0]/RDIV
X
This set of registers configures and reports the alarm status of TU #4 in TUG2 #1
to TUG2 #7. These registers have no effect in TU3 mode. When the
corresponding TUG2 tributary group is configured to TU2 (VT6), VT3 or TU12
(VT2) mode, the associated register in this set has no effect.
RDIV:
The RDIV bit indicates the remote defect indication status of tributary TU #4
in the corresponding TUG2 when RDIZ7EN is low. RDIV is set high when the
RDI bit in the V5 byte is set high for five or ten consecutive multiframes as
determined by the RDI10 bit in the RTOP and RTTB Configuration registers
(addresses 0CH, 0DH, and 0EH). RDIV is set low when the RDI bit is set low
for five or ten consecutive multiframes as determined by the RDI10 bit
RFIV:
The RFIV bit indicates the remote failure indication status of tributary TU #4 in
the corresponding TUG2 when RDIZ7EN is set low. RFIV is set high when
the RFI bit in the V5 byte is set high for five or ten consecutive multiframes as
determined by the RDI10 bit in the RTOP and RTTB Configuration registers
(addresses 0CH, 0DH, and 0EH). RFIV is set low when the RFI bit is set low
for five or ten consecutive multiframes as determined by the RDI10 bit.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
219
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
ERDIV[2:0]:
The ERDIV[2:0] bits indicates the extended remote defect indication status of
tributary TU #4 in the corresponding TUG2 when RDIZ7EN is set high. The
ERDIV[2:0] bits are set to a new code when the same code in the extended
RDI bits of the Z7 byte is seen for five or ten consecutive multiframes as
determined by the RDI10 bit in the RTOP and RTTB Configuration registers
(addresses 0CH, 0DH, and 0EH).
PSLMV:
The PSLMV bit indicates the path signal mismatch status of tributary TU #4 in
the corresponding TUG2. PSLMV is set high when the accepted PSL differs
from the provisioned value. PSLMV is set low when the accepted PSL has
the same value as the provisioned one.
PSLUV:
The PSLUV bit indicates the path signal unstable status of tributary TU #4 in
the corresponding TUG2. The PSL unstable counter is incremented if the
PSL of the current multiframe differs form that in the previous multiframe. The
counter is cleared to zero when the same PSL is received for five consecutive
multiframes. The tributary PSL unstable alarm is asserted and PSLUV set
high when the unstable counter reaches five. The PSL unstable alarm is
negated and PSLUV set low when the unstable counter is cleared.
PDIVEN:
The PDIVEN bit modifies the payload defect indication status PDIV of
tributary TU #4 in the corresponding TUG2 . The PDIV output is set high
when the PSL in the V5 byte is set to the bit pattern specified by the
PDICODE[2:0] input for five consecutive multiframes. The PDIV output is set
low when the PSL is set to any other bit pattern for five consecutive
multiframes. When PDIVEN is set high, the PDIV output is permanently set
high independent of the tributary's defect status until the PDIVEN is set low.
TUPTE:
The TUPTE bit determines the alarm conditions under which AIS is inserted
for tributary TU #4 in the corresponding TUG2. TUPTE is set high if tributary
TU #4 is to be terminated in the network element containing this TUPP-PLUS
device. In this case, tributary AIS is automatically inserted based on the
contents of the global Tributary Alarm AIS Control register (address 10H).
TUPTE is set low if tributary TU #4 is part of the through traffic in the network
element containing this TUPP-PLUS device. In this case, tributary AIS is only
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
220
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
inserted when a loss of pointer (LOP) or a loss of multiframe (LOM) alarm is
detected (as determined by the global Tributary Alarm AIS Control register).
RDIZ7EN:
The RDIZ7EN indicates which tributary path overhead byte is used for
controlling the ERDI[2:0] or RDI/RFI bits of tributary TU #4 in the
corresponding TUG2 . When RDIZ7EN is set low, the RDI and RFI bits in the
V5 byte are used to control the RDIV and RFIV register bits. When RDIZ7EN
is set high, the three bit extended RDI code in the Z7 byte is used to control
the ERDIV[2:0] register bits.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
221
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1C2H, 1CAH, 1D2H, 1DAH, 1E2H, 1EAH, 1F2H:
Register 2C2H, 2CAH, 2D2H, 2DAH, 2E2H, 2EAH, 2F2H:
Register 3C2H, 3CAH, 3D2H, 3DAH, 3E2H, 3EAH, 3F2H:
RTOP, TU #4 in TUG2 #1 to TUG2 #7, Expected Path Signal Label
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
Unused
X
Bit 2
R/W
EPSL[2]
0
Bit 1
R/W
EPSL[1]
0
Bit 0
R/W
EPSL[0]
0
This set of registers configures the expected path signal label of TU #4 in TUG2
#1 to TUG2 #7. These registers have no effect in TU3 mode. When the
corresponding TUG2 tributary group is configured to TU2 (VT6), VT3 or TU12
(VT2) mode, the associated register in this set has no effect.
EPSL[2:0]:
The EPSL[2:0] bits specifies the expected path signal label of tributary TU #4
in the corresponding TUG2. The expected PSL is compared with the
accepted PSL to determine the PSLM state.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
222
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1C3H, 1CBH, 1D3H, 1DBH, 1E3H, 1EBH, 1F3H:
Register 2C3H, 2CBH, 2D3H, 2DBH, 2E3H, 2EBH, 2F3H:
Register 3C3H, 3CBH, 3D3H, 3DBH, 3E3H, 3EBH, 3F3H:
RTOP, TU #4 in TUG2 #1 to TUG2 #7, Path Signal Label
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
Unused
X
Bit 2
R
APSL[2]
0
Bit 1
R
APSL[1]
0
Bit 0
R
APSL[0]
0
This set of register reports the accepted path signal label of TU #4 in TUG2 #1 to
TUG2 #7. These registers have no effect in TU3 mode. When the corresponding
TUG2 tributary group is configured to TU2 (VT6), VT3 or TU12 (VT2) mode, the
associated register in this set has no effect.
APSL[2:0]:
The APSL[2:0] bits reports the accepted path signal label of tributary TU #4 in
the corresponding TUG2. An incoming PSL is accepted when the same value
is received for five consecutive multiframes.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
223
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1C4H, 1CCH, 1D4H, 1DCH, 1E4H, 1ECH, 1F4H:
Register 2C4H, 2CCH, 2D4H, 2DCH, 2E4H, 2ECH, 2F4H:
Register 3C4H, 3CCH, 3D4H, 3DCH, 3E4H, 3ECH, 3F4H:
RTOP, TU #4 in TUG2 #1 to TUG2 #7, BIP-2 Error Count LSB
Bit
Type
Function
Default
Bit 7
R
BIP[7]
X
Bit 6
R
BIP[6]
X
Bit 5
R
BIP[5]
X
Bit 4
R
BIP[4]
X
Bit 3
R
BIP[3]
X
Bit 2
R
BIP[2]
X
Bit 1
R
BIP[1]
X
Bit 0
R
BIP[0]
X
Register 1C5H, 1CDH, 1D5H, 1DDH, 1E5H, 1EDH, 1F5H:
Register 2C5H, 2CDH, 2D5H, 2DDH, 2E5H, 2EDH, 2F5H:
Register 3C5H, 3CDH, 3D5H, 3DDH, 3E5H, 3EDH, 3F5H:
RTOP, TU #4 in TUG2 #1 to TUG2 #7, BIP-2 Error Count MSB
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
Unused
X
Bit 2
R
BIP[10]
X
Bit 1
R
BIP[9]
X
Bit 0
R
BIP[8]
X
These registers reports the number of block interleave parity (BIP-2) errors
detected in TU #4 in TUG2 #1 to TUG2 #7 in the previous accumulation interval.
These registers contain invalid data in TU3 mode. When the corresponding
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
224
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
TUG2 tributary group is configured to TU2 (VT6), VT3 or TU12 (VT2) mode, the
associated registers in this set contain invalid data. These registers do not
saturate.
BIP[10:0]:
The BIP[10:0] bits reports the number of tributary path bit-interleaved parity
errors that have been detected since the last time the BIP-2 registers were
polled. The BIP-2 registers are polled by writing to the Input Signal Activity
Monitor, Accumulate Trigger register. The write access transfers the internally
accumulated error count to the BIP-2 registers within 10 µs and resets the
internal counter simultaneously to begin a new cycle of error accumulation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
225
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1C6H, 1CEH, 1D6H, 1DEH, 1E6H, 1EEH, 1F6H:
Register 2C6H, 2CEH, 2D6H, 2DEH, 2E6H, 2EEH, 2F6H:
Register 3C6H, 3CEH, 3D6H, 3DEH, 3E6H, 3EEH, 3F6H:
RTOP, TU #4 in TUG2 #1 to TUG2 #7, FEBE Error Count LSB
Bit
Type
Function
Default
Bit 7
R
FEBE[7]
X
Bit 6
R
FEBE[6]
X
Bit 5
R
FEBE[5]
X
Bit 4
R
FEBE[4]
X
Bit 3
R
FEBE[3]
X
Bit 2
R
FEBE[2]
X
Bit 1
R
FEBE[1]
X
Bit 0
R
FEBE[0]
X
Register 1C7H, 1CFH, 1D7H, 1DFH, 1E7H, 1EFH, 1F7H:
Register 2C7H, 2CFH, 2D7H, 2DFH, 2E7H, 2EFH, 2F7H:
Register 3C7H, 3CFH, 3D7H, 3DFH, 3E7H, 3EFH, 3F7H:
RTOP, TU #4 in TUG2 #1 to TUG2 #7, FEBE Error Count MSB
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
Unused
X
Bit 2
R
FEBE[10]
X
Bit 1
R
FEBE[9]
X
Bit 0
R
FEBE[8]
X
These registers reports the number of far end block errors (FEBE) detected in TU
#4 in TUG2 #1 to TUG2 #7 in the previous accumulation interval. These registers
contain invalid data in TU3 mode. When the corresponding TUG2 tributary group
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
226
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
is configured to TU2 (VT6), VT3 or TU12 (VT2) mode, the associated registers in
this set contain invalid data.
FEBE[10:0]:
The FEBE[10:0] bits reports the number of tributary path far end block errors
that have been detected since the last time the FEBE registers were polled.
The FEBE registers are polled by writing to the Input Signal Activity Monitor,
Accumulate Trigger register. The write access transfers the internally
accumulated error count to the FEBE registers within 10 µs and resets the
internal counter simultaneoulsly to begin a new cycle of error accumulation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
227
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1F8H, 2F8H, 3F8H: RTOP, TU #4 in TUG2 #1 to TUG2 #7, COPSL
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
0
Bit 6
R
COPSL7I
0
Bit 5
R
COPSL6I
0
Bit 4
R
COPSL5I
0
Bit 3
R
COPSL4I
0
Bit 2
R
COPSL3I
0
Bit 1
R
COPSL2I
0
Bit 0
R
COPSL1I
0
This register is used to identify and acknowledge change of path signal label
interrupts for the tributaries TU #4 in TUG2 #1 TO TUG2 #7.
COPSL1I-COPSL7I:
The COPSL1I to COPSL7I bits identify the source of change of path signal
label interrupts. In TU3 mode, these bits are unused and will return a logic 0
when read. When the corresponding TUG2 tributary group is configured for
TU2 (VT6), VT3 or TU12 (VT2) mode, the associated COPSL xI bit is unused
and will return a logic 0 when read. When operational, the COPSL1I to
COPSL7I bits report and acknowledge COPSL interrupt of TU #4 in TUG2 #1
to TUG2 #7, respectively. Interrupts are generated when the accepted PSL
changes. An COPSLxI bit is set high when a change of PSL event on the
associated tributary (TU #4 in TUG2 #x) occurs and are cleared immediately
following a read of this register, which also acknowledges and clears the
interrupt. COPSLxI remains valid when interrupts are not enabled (COPSLE
set low) and may be polled to detect change of path signal label events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
228
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1F9H, 2F9H, 3F9H: RTOP, TU #4 in TUG2 #1 to TUG2 #7, PSLM
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
PSLM7I
0
Bit 5
R
PSLM6I
0
Bit 4
R
PSLM5I
0
Bit 3
R
PSLM4I
0
Bit 2
R
PSLM3I
0
Bit 1
R
PSLM2I
0
Bit 0
R
PSLM1I
0
This register is used to identify and acknowledge path signal label mismatch
interrupts for the tributaries TU #4 in TUG2 #1 TO TUG2 #7.
PSLM1I-PSLM7I:
The PSLM1I to PSLM7I bits identify the source of path signal label mismatch
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6), VT3 or TU12 (VT2) mode, the associated PSLM xI bit is unused and
will return a logic 0 when read. When operational, the PSLM1I to PSLM7I bits
report and acknowledge PSLM interrupt of TU #4 in TUG2 #1 to TUG2 #7,
respectively. Interrupts are generated when the accepted PSL becomes
matched to the expected PSL or becomes mismatched to the expected PSL.
An PSLMxI bit is set high when a change of PSL matched state on the
associated tributary (TU #4 in TUG2 #x) occurs and are cleared immediately
following a read of this register, which also acknowledges and clears the
interrupt. PSLMxI remains valid when interrupts are not enabled (PSLME set
low) and may be polled to detect path signal label match/mismatch events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
229
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1FAH, 2FAH, 3FAH: RTOP, TU #4 in TUG2 #1 to TUG2 #7, PSLU
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
PSLU7I
0
Bit 5
R
PSLU6I
0
Bit 4
R
PSLU5I
0
Bit 3
R
PSLU4I
0
Bit 2
R
PSLU3I
0
Bit 1
R
PSLU2I
0
Bit 0
R
PSLU1I
0
This register is used to identify and acknowledge path signal label unstable
interrupts for the tributaries TU #4 in TUG2 #1 TO TUG2 #7.
PSLU1I-PSLU7I:
The PSLU1I to PSLU7I bits identify the source of path signal label mismatch
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6), VT3 or TU12 (VT2) mode, the associated PSLU xI bit is unused and will
return a logic 0 when read. When operational, the PSLU1I to PSLU7I bits
report and acknowledge PSLU interrupt of TU #4 in TUG2 #1 to TUG2 #7,
respectively. Interrupts are generated when the received PSL becomes
unstable or returns to stable. An PSLUxI bit is set high when a change of
PSL unstable state on the associated tributary (TU #4 in TUG2 #x) occurs
and are cleared immediately following a read of this register, which also
acknowledges and clears the interrupt. PSLU xI remains valid when interrupts
are not enabled (PSLUE set low) and may be polled to detect path signal
label stable/unstable events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
230
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1FBH, 2FBH, 3FBH: RTOP, TU #4 in TUG2 #1 to TUG2 #7, RDI
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
RDI7I
0
Bit 5
R
RDI6I
0
Bit 4
R
RDI5I
0
Bit 3
R
RDI4I
0
Bit 2
R
RDI3I
0
Bit 1
R
RDI2I
0
Bit 0
R
RDI1I
0
This register is used to identify and acknowledge remote defect indication
interrupts for the tributaries TU #4 in TUG2 #1 TO TUG2 #7.
RDI1I-RDI7I:
The RDI1I to RDI7I bits identify the source of remote defect indication
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6), VT3 or TU12 (VT2) mode, the associated RDIxI bit is unused and will
return a logic 0 when read. When operational, the RDI1I to RDI7I bits report
and acknowledge RDI interrupt of TU #4 in TUG2 #1 to TUG2 #7,
respectively. Interrupts are generated when the received RDI state changes.
An RDIxI bit is set high when a change of RDI state on the associated
tributary (TU #4 in TUG2 #x) occurs and are cleared immediately following a
read of this register, which also acknowledges and clears the interrupt. RDIxI
remains valid when interrupts are not enabled (RDIE set low) and may be
polled to detect change of remote defect indication events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
231
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1FCH, 2FCH, 3FCH: RTOP, TU #4 in TUG2 #1 to TUG2 #7, RFI
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
RFI7I
0
Bit 5
R
RFI6I
0
Bit 4
R
RFI5I
0
Bit 3
R
RFI4I
0
Bit 2
R
RFI3I
0
Bit 1
R
RFI2I
0
Bit 0
R
RFI1I
0
This register is used to identify and acknowledge remote failure indication
interrupts for the tributaries TU #4 in TUG2 #1 TO TUG2 #7.
RFI1I-RFI7I:
The RFI1I to RFI7I bits identify the source of remote failure indication
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6), VT3 or TU12 (VT2) mode, the associated RFIxI bit is unused and will
return a logic 0 when read. When operational, the RFI1I to RFI7I bits report
and acknowledge RFI interrupt of TU #4 in TUG2 #1 to TUG2 #7, respectively.
Interrupts are generated when the received RFI state changes. An RFIxI bit
is set high when a change of RFI state on the associated tributary (TU #4 in
TUG2 #x) occurs and are cleared immediately following a read of this
register, which also acknowledges and clears the interrupt. RFIxI remains
valid when interrupts are not enabled (RFIE set low) and may be polled to
detect change of remote failure indication events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
232
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1FDH, 2FDH, 3FDH: RTOP, TU #4 in TUG2 #1 to TUG2 #7, In Band
Error Reporting Configuration
Bit
Type
Bit 7
Function
Default
Unused
x
Bit 6
R/W
IBER7
0
Bit 5
R/W
IBER6
0
Bit 4
R/W
IBER5
0
Bit 3
R/W
IBER4
0
Bit 2
R/W
IBER3
0
Bit 1
R/W
IBER2
0
Bit 0
R/W
IBER1
0
This register enables the inband error reporting mode for the tributaries TU #4 in
TUG2 #1 to TUG2 #7.
IBER1-IBER7:
The IBER1 to IBER7 bits control in band error reporting for tributary TU #4 in
TUG2 #1 to TUG2 #7, respectively. Setting an IBERx bit high causes in band
error reporting information to be inserted in the V5 byte of tributary TU #4 of
the corresponding TUG2. When an IBER x bit is low, in band error reporting is
disabled and the V5 byte of tributary TU #4 of the corresponding TUG2 is not
modified.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
233
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1FEH, 2FEH, 3FEH: RTOP, TU #4 in TUG2 #1 to TUG2 #7,
Controllable Output Configuration
Bit
Type
Bit 7
Function
Default
Unused
x
Bit 6
R/W
COUT7
0
Bit 5
R/W
COUT6
0
Bit 4
R/W
COUT5
0
Bit 3
R/W
COUT4
0
Bit 2
R/W
COUT3
0
Bit 1
R/W
COUT2
0
Bit 0
R/W
COUT1
0
This register controls the COUT output for the tributaries TU #4 in TUG2 #1 to
TUG2 #7.
COUT1-COUT7:
The COUT1 to COUT7 bits control the COUT output for tributary TU #4 in
TUG2 #1 to TUG2 #7, respectively. Setting a COUTx bit high will force the
COUT output to be high when the incoming data stream is part of tributary
TU #4 of the corresponding TUG2. When an COUTx bit is low, the COUT
output will be low when the incoming data stream is part of tributary TU #4 of
the corresponding TUG2.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
234
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 1FFH, 2FFH, 3FFH: RTOP Status
Bit
Type
Function
Default
Bit 7
R/W
Reserved
0
Bit 6
R/W
Reserved
0
Bit 5
Unused
X
Bit 4
Unused
X
Bit 3
Unused
X
Bit 2
Unused
X
Bit 1
R/W
BLKFEBE
0
Bit 0
R
BUSY
X
This register configures and reports the status of the various internal operations
inside RTOP.
BUSY:
The BUSY bit indicates the status of the transfer of BIP and FEBE counts
from the counters to the holding registers. BUSY is set high on the rising
edge of the LCLK input or on a write access to any of the BIP or FEBE
counters. BUSY is set low when all the counters values have been
transferred to holding registers. The elapsed time shall be less than 10 µs.
BLKFEBE:
The block FEBE accumulation control bit selects between counting of FEBEs
in the incoming TU3 stream on a block or bit basis. When BLKFEBE is set
high, FEBE count codes in the range of 1 to 8 are accumulated on a block
basis as a single FEBE event. All other codes are counted zero events.
When BLKFEBE is set low, FEBE count codes in the range of 1 to 8 are
accumulated on a bit basis as a up to 8 FEBE events. All other codes are
counted zero events.
Reserved:
The Reserved bits must be written with a logic 0 for proper operation of the
TUPP-PLUS.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
235
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
9.4
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
RTTB #1, RTTB #2 and RTTB #3 Registers
Register 400H, 440H, 480H: RTTB, TU3 or TU #1 in TUG2 #1, Configuration
and Status
Bit
Type
Function
Default
Bit 7
R/W
CONFIG[1]
1
Bit 6
R/W
CONFIG[0]
1
Bit 5
R/W
NOSYNC
0
Bit 4
R/W
LEN16
0
Bit 3
R
TIMV
X
Bit 2
R/W
TIME
0
Bit 1
R
TIUV
X
Bit 0
R/W
TIUE
0
In TU3 mode (TU3 bit in VTPP Configuration register set high), this register
reports the status and configures operational modes of the TU3 mapped into a
TUG3 handled by the RTTB. Out of TU3 mode, this register reports the status
and configures the operational modes of TU #1 in TUG2 #1.
TIUE:
The TIUE bit enables trail trace identifier unstable interrupts for tributary
TU #1 in TUG2 #1 or TU3 When TIUE is set high, an interrupt is generated
upon detection of an unstable identifier and upon return to a stable identifier.
Interrupts due to TIU status change are masked when TIUE is set low.
TIUV:
The TIUV bit indicates the trail trace identifier unstable status of tributary
TU #1 in TUG2 #1 or TU3.
TIME:
The TIME bit enables trail trace identifier mismatch interrupts for tributary
TU #1 in TUG2 #1 or TU3. When TIME is set high, an interrupt is generated
upon detection of a mismatched identifier and upon return to a matched
identifier. Interrupts due to TIM status change are masked when TIME is set
low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
236
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
TIMV:
The TIUV bit indicates the trail trace identifier mismatch status of tributary
TU #1 in TUG2 #1 or TU3.
LEN16:
The path trace message length bit (LEN16) selects the length of the path
trace message to be 16 bytes or 64 bytes for tributary TU #1 in TUG2 #1 or
TU3. When LEN16 is set high, the message length is set to 16 bytes. When
LEN16 is set low, the message length is set to 64 bytes.
NOSYNC:
The path trace message synchronization disable bit (NOSYNC) disables the
synchronized writing of the path trace message into the trace buffer based on
the contents of the message for tributary TU #1 in TUG2 #1 or TU3. When
LEN16 is set high and NOSYNC is set low, the receive path trace message
byte with its most significant bit set to logic one will be written to the first
location in the buffer. When LEN16 is set low, and NOSYNC is also set low,
the byte after the carriage return/linefeed (CR/LF) sequence will be written to
the first location in the buffer. When NOSYNC is set high, synchronization is
disabled, and the path trace message buffer behaves as a circular buffer.
CONFIG[1:0]:
The CONFIG[1:0] bits specify the tributary configuration of tributary group
TUG2 #1. The CONFIG[1:0] bits have no effect in TU3 mode. The
configuration specified by the CONFIG[1:0] bits are selected as follows:
CONFIG[1]
CONFIG[0]
Configuration
Active TU (VT)
0
0
TU2 (VT6)
#1
0
1
VT3
#1, #2
1
0
TU12 (VT2)
#1, #2, #3
1
1
TU11 (VT1.5)
#1, #2, #3, #4
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
237
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 401H-406H, 441H-446H, 481H-486H: RTTB, TU #1 in TUG2 #2 to
TUG2 #7, Configuration and Status
Bit
Type
Function
Default
Bit 7
R/W
CONFIG[1]
1
Bit 6
R/W
CONFIG[0]
1
Bit 5
R/W
NOSYNC
0
Bit 4
R/W
LEN16
0
Bit 3
R
TIMV
X
Bit 2
R/W
TIME
0
Bit 1
R
TIUV
X
Bit 0
R/W
TIUE
0
This set of registers reports the status and configures the operational modes of
TU #1 in TUG2 #2 to TUG2 #7. These registers have no effect in TU3 mode.
TIUE:
The TIUE bit enables trail trace identifier unstable interrupts for tributary
TU #1 in the corresponding TUG2. When TIUE is set high, an interrupt is
generated upon detection of an unstable identifier and upon return to a stable
identifier. Interrupts due to TIU status change are masked when TIUE is set
low.
TIUV:
The TIUV bit indicates the trail trace identifier unstable status of tributary
TU #1 in the corresponding TUG2.
TIME:
The TIME bit enables trail trace identifier mismatch interrupts for tributary
TU #1 in the corresponding TUG2. When TIME is set high, an interrupt is
generated upon detection of a mismatched identifier and upon return to a
matched identifier. Interrupts due to TIM status change are masked when
TIME is set low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
238
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
TIMV:
The TIMV bit indicates the trail trace identifier mismatch status of tributary
TU #1 in the corresponding TUG2.
LEN16:
The path trace message length bit (LEN16) selects the length of the path
trace message to be 16 bytes or 64 bytes for tributary TU #1 in the
corresponding TUG2. When LEN16 is set high, the message length is set to
16 bytes. When LEN16 is set low, the message length is set to 64 bytes.
NOSYNC:
The path trace message synchronization disable bit (NOSYNC) disables the
synchronized writing of the path trace message into the trace buffer based on
the contents of the message for tributary TU #1 in the corresponding TUG2.
When LEN16 is set high and NOSYNC is set low, the receive path trace
message byte with its most significant bit set to logic one will be written to the
first location in the buffer. When LEN16 is set low, and NOSYNC is also set
low, the byte after the carriage return/linefeed (CR/LF) sequence will be
written to the first location in the buffer. When NOSYNC is set high,
synchronization is disabled, and the path trace message buffer behaves as a
circular buffer.
CONFIG[1:0]:
The CONFIG[1:0] bits specify the tributary configuration of the corresponding
tributary group TUG2. The configuration specified by the CONFIG[1:0] bits
are selected as follows:
CONFIG[1]
CONFIG[0]
Configuration
Active TU (VT)
0
0
TU2 (VT6)
#1
0
1
VT3
#1, #2
1
0
TU12 (VT2)
#1, #2, #3
1
1
TU11 (VT1.5)
#1, #2, #3, #4
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
239
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 408H-40EH, 448H-44EH, 488H-48EH: RTTB, TU #2 in TUG2 #1 to
TUG2 #7, Configuration and Status
Bit
Type
Function
Default
Bit 7
R
CONFIG[1]
1
Bit 6
R
CONFIG[0]
1
Bit 5
R/W
NOSYNC
0
Bit 4
R/W
LEN16
0
Bit 3
R
TIMV
X
Bit 2
R/W
TIME
0
Bit 1
R
TIUV
X
Bit 0
R/W
TIUE
0
This set of registers reports the status and configures the operational modes of
TU #2 in TUG2 #1 to TUG2 #7. These registers have no effect in TU3 mode.
When the corresponding TUG2 tributary group is configured to TU2 (VT6) mode,
the associated register in this set has no effect.
TIUE:
The TIUE bit enables trail trace identifier unstable interrupts for tributary
TU #2 in the corresponding TUG2. When TIUE is set high, an interrupt is
generated upon detection of an unstable identifier and upon return to a stable
identifier. Interrupts due to TIU status change are masked when TIUE is set
low.
TIUV:
The TIUV bit indicates the trail trace identifier unstable status of tributary
TU #2 in the corresponding TUG2.
TIME:
The TIME bit enables trail trace identifier mismatch interrupts for tributary
TU #2 in the corresponding TUG2. When TIME is set high, an interrupt is
generated upon detection of a mismatched identifier and upon return to a
matched identifier. Interrupts due to TIM status change are masked when
TIME is set low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
240
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
TIMV:
The TIMV bit indicates the trail trace identifier mismatch status of tributary
TU #2 in the corresponding TUG2.
LEN16:
The path trace message length bit (LEN16) selects the length of the path
trace message to be 16 bytes or 64 bytes for tributary TU #2 in the
corresponding TUG2. When LEN16 is set high, the message length is set to
16 bytes. When LEN16 is set low, the message length is set to 64 bytes.
NOSYNC:
The path trace message synchronization disable bit (NOSYNC) disables the
synchronized writing of the path trace message into the trace buffer based on
the contents of the message for tributary TU #2 in the corresponding TUG2.
When LEN16 is set high and NOSYNC is set low, the receive path trace
message byte with its most significant bit set to logic one will be written to the
first location in the buffer. When LEN16 is set low, and NOSYNC is also set
low, the byte after the carriage return/linefeed (CR/LF) sequence will be
written to the first location in the buffer. When NOSYNC is set high,
synchronization is disabled, and the path trace message buffer behaves as a
circular buffer.
CONFIG[1:0]:
The CONFIG[1:0] bits specify the tributary configuration of the corresponding
tributary group TUG2. The configuration specified by the CONFIG[1:0] bits
are selected as follows:
CONFIG[1]
CONFIG[0]
Configuration
Active TU (VT)
0
0
TU2 (VT6)
#1
0
1
VT3
#1, #2
1
0
TU12 (VT2)
#1, #2, #3
1
1
TU11 (VT1.5)
#1, #2, #3, #4
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
241
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 410H-416H, 450H-456H, 490H-496H: RTTB, TU #3 in TUG2 #1 to
TUG2 #7, Configuration and Status
Bit
Type
Function
Default
Bit 7
R
CONFIG[1]
1
Bit 6
R
CONFIG[0]
1
Bit 5
R/W
NOSYNC
0
Bit 4
R/W
LEN16
0
Bit 3
R
TIMV
X
Bit 2
R/W
TIME
0
Bit 1
R
TIUV
X
Bit 0
R/W
TIUE
0
This set of registers reports the status and configures the operational modes of
TU #3 in TUG2 #1 to TUG2 #7. These registers have no effect in TU3 mode.
When the corresponding TUG2 tributary group is configured to TU2 (VT6) or VT3
mode, the associated register in this set has no effect.
TIUE:
The TIUE bit enables trail trace identifier unstable interrupts for tributary
TU #3 in the corresponding TUG2. When TIUE is set high, an interrupt is
generated upon detection of an unstable identifier and upon return to a stable
identifier. Interrupts due to TIU status change are masked when TIUE is set
low.
TIUV:
The TIUV bit indicates the trail trace identifier unstable status of tributary
TU #3 in the corresponding TUG2.
TIME:
The TIME bit enables trail trace identifier mismatch interrupts for tributary
TU #3 in the corresponding TUG2. When TIME is set high, an interrupt is
generated upon detection of a mismatched identifier and upon return to a
matched identifier. Interrupts due to TIM status change are masked when
TIME is set low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
242
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
TIMV:
The TIMV bit indicates the trail trace identifier mismatch status of tributary
TU #3 in the corresponding TUG2.
LEN16:
The path trace message length bit (LEN16) selects the length of the path
trace message to be 16 bytes or 64 bytes for tributary TU #3 in the
corresponding TUG2. When LEN16 is set high, the message length is set to
16 bytes. When LEN16 is set low, the message length is set to 64 bytes.
NOSYNC:
The path trace message synchronization disable bit (NOSYNC) disables the
synchronized writing of the path trace message into the trace buffer based on
the contents of the message for tributary TU #3 in the corresponding TUG2.
When LEN16 is set high and NOSYNC is set low, the receive path trace
message byte with its most significant bit set to logic one will be written to the
first location in the buffer. When LEN16 is set low, and NOSYNC is also set
low, the byte after the carriage return/linefeed (CR/LF) sequence will be
written to the first location in the buffer. When NOSYNC is set high,
synchronization is disabled, and the path trace message buffer behaves as a
circular buffer.
CONFIG[1:0]:
The CONFIG[1:0] bits specify the tributary configuration of the corresponding
tributary group TUG2. The configuration specified by the CONFIG[1:0] bits
are selected as follows:
CONFIG[1]
CONFIG[0]
Configuration
Active TU (VT)
0
0
TU2 (VT6)
#1
0
1
VT3
#1, #2
1
0
TU12 (VT2)
#1, #2, #3
1
1
TU11 (VT1.5)
#1, #2, #3, #4
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
243
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 418H-41EH, 458H-45EH, 498H-49EH: RTTB, TU #4 in TUG2 #1 to
TUG2 #7, Configuration and Status
Bit
Type
Function
Default
Bit 7
R
CONFIG[1]
1
Bit 6
R
CONFIG[0]
1
Bit 5
R/W
NOSYNC
0
Bit 4
R/W
LEN16
0
Bit 3
R
TIMV
X
Bit 2
R/W
TIME
0
Bit 1
R
TIUV
X
Bit 0
R/W
TIUE
0
This set of registers reports the status and configures the operational modes of
TU #4 in TUG2 #1 to TUG2 #7. These registers have no effect in TU3 mode. When
the corresponding TUG2 tributary group is configured to TU2 (VT6), VT3 or,
TU12 (VT2) mode, the associated register in this set has no effect.
TIUE:
The TIUE bit enables trail trace identifier unstable interrupts for tributary
TU #4 in the corresponding TUG2. When TIUE is set high, an interrupt is
generated upon detection of an unstable identifier and upon return to a stable
identifier. Interrupts due to TIU status change are masked when TIUE is set
low.
TIUV:
The TIUV bit indicates the trail trace identifier unstable status of tributary
TU #4 in the corresponding TUG2.
TIME:
The TIME bit enables trail trace identifier mismatch interrupts for tributary
TU #4 in the corresponding TUG2. When TIME is set high, an interrupt is
generated upon detection of a mismatched identifier and upon return to a
matched identifier. Interrupts due to TIM status change are masked when
TIME is set low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
244
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
TIMV:
The TIUV bit indicates the trail trace identifier mismatch status of tributary
TU #4 in the corresponding TUG2.
LEN16:
The path trace message length bit (LEN16) selects the length of the path
trace message to be 16 bytes or 64 bytes for tributary TU #4 in the
corresponding TUG2. When LEN16 is set high, the message length is set to
16 bytes. When LEN16 is set low, the message length is set to 64 bytes.
NOSYNC:
The path trace message synchronization disable bit (NOSYNC) disables the
synchronized writing of the path trace message into the trace buffer based on
the contents of the message for tributary TU #4 in the corresponding TUG2.
When LEN16 is set high and NOSYNC is set low, the receive path trace
message byte with its most significant bit set to logic one will be written to the
first location in the buffer. When LEN16 is set low, and NOSYNC is also set
low, the byte after the carriage return/linefeed (CR/LF) sequence will be
written to the first location in the buffer. When NOSYNC is set high,
synchronization is disabled, and the path trace message buffer behaves as a
circular buffer.
CONFIG[1:0]:
The CONFIG[1:0] bits specify the tributary configuration of the corresponding
tributary group TUG2. The configuration specified by the CONFIG[1:0] bits
are selected as follows:
CONFIG[1]
CONFIG[0]
Configuration
Active TU (VT)
0
0
TU2 (VT6)
#1
0
1
VT3
#1, #2
1
0
TU12 (VT2)
#1, #2, #3
1
1
TU11 (VT1.5)
#1, #2, #3, #4
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
245
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 420H, 460H, 4A0H: RTTB, TU3 or TU #1 in TUG2 #1 to TUG2 #7, TIM
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
TIM7I
0
Bit 5
R
TIM6I
0
Bit 4
R
TIM5I
0
Bit 3
R
TIM4I
0
Bit 2
R
TIM3I
0
Bit 1
R
TIM2I
0
Bit 0
R
TIM1I
0
This register is used to identify and acknowledge trail trace identifier mismatch
interrupts for the tributaries TU #1 in TUG2 #1 to TUG2 #7. It is also used to
identify and acknowledge TU3 trail trace identifier mismatch interrupts.
TIM1I:
The TIM1I bit identifies the source of trail trace identifier mismatch interrupts.
In TU3 mode, The TIM1I bit reports and acknowledges TIM interrupt of the
TU3 trail trace identifier. Out of TU3 mode, TIM1I bit reports and
acknowledges TIM interrupt of TU #1 in TUG2 #1. Interrupts are generated
upon change of identifier mismatch state. The TIM1I bit is set high when a
trail trace identifier mismatch event and is cleared immediately following a
read of this register, which also acknowledges and clears the interrupt. the
TIM1I bit remains valid when interrupts are not enabled (TIME set low) and
may be polled to detect trail trace identifier mismatch events.
TIM2I-TIM7I:
The TIM2I to TIM7I bits identify the source of trail trace identifier mismatch
interrupts. TIM2I to TIM7I bits report and acknowledge TIM interrupt of TU #1
in TUG2 #2 to TUG2 #7, respectively. Interrupts are generated upon change
of identifier mismatch state. An TIMxI bit is set high when a trail trace
identifier mismatch event on the corresponding tributary (TU #1 in TUG2 #x)
occurs and are cleared immediately following a read of this register, which
also acknowledges and clears the interrupt. TIM xI remains valid when
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
246
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
interrupts are not enabled (TIME set low) and may be polled to detect trail
trace identifier mismatch events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
247
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 421H, 461H, 4A1H: RTTB, TU #2 in TUG2 #1 to TUG2 #7, TIM
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
TIM7I
0
Bit 5
R
TIM6I
0
Bit 4
R
TIM5I
0
Bit 3
R
TIM4I
0
Bit 2
R
TIM3I
0
Bit 1
R
TIM2I
0
Bit 0
R
TIM1I
0
This register is used to identify and acknowledge trail trace identifier mismatch
interrupts for the tributaries TU #2 in TUG2 #1 to TUG2 #7.
TIM1I-TIM7I:
The TIM1I to TIM7I bits identify the source of trail trace identifier mismatch
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6) mode, the associated TIMxI bit is unused and will return a logic 0 when
read. When operational, the TIM1I to TIM7I bits report and acknowledge TIM
interrupt of TU #2 in TUG2 #1 to TUG2 #7, respectively. Interrupts are
generated upon change of identifier mismatch state. An TIM xI bit is set high
when a trail trace identifier mismatch event on the corresponding tributary
(TU #2 in TUG2 #x) occurs and are cleared immediately following a read of
this register, which also acknowledges and clears the interrupt. TIM xI
remains valid when interrupts are not enabled (TIME set low) and may be
polled to detect trail trace identifier mismatch events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
248
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 422H, 462H, 4A2H: RTTB, TU #3 in TUG2 #1 to TUG2 #7, TIM
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
TIM7I
0
Bit 5
R
TIM6I
0
Bit 4
R
TIM5I
0
Bit 3
R
TIM4I
0
Bit 2
R
TIM3I
0
Bit 1
R
TIM2I
0
Bit 0
R
TIM1I
0
This register is used to identify and acknowledge trail trace identifier mismatch
interrupts for the tributaries TU #3 in TUG2 #1 to TUG2 #7.
TIM1I-TIM7I:
The TIM1I to TIM7I bits identify the source of trail trace identifier mismatch
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6) or VT3 mode, the associated TIMxI bit is unused and will return a logic
0 when read. When operational, the TIM1I to TIM7I bits report and
acknowledge TIM interrupt of TU #3 in TUG2 #1 to TUG2 #7, respectively.
Interrupts are generated upon change of identifier mismatch state. An TIM xI
bit is set high when a trail trace identifier mismatch event on the
corresponding tributary (TU #3 in TUG2 #x) occurs and are cleared
immediately following a read of this register, which also acknowledges and
clears the interrupt. TIMxI remains valid when interrupts are not enabled
(TIME set low) and may be polled to detect trail trace identifier mismatch
events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
249
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 423H, 463H, 4A3H: RTTB, TU #4 in TUG2 #1 to TUG2 #7, TIM
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
TIM7I
0
Bit 5
R
TIM6I
0
Bit 4
R
TIM5I
0
Bit 3
R
TIM4I
0
Bit 2
R
TIM3I
0
Bit 1
R
TIM2I
0
Bit 0
R
TIM1I
0
This register is used to identify and acknowledge trail trace identifier mismatch
interrupts for the tributaries TU #4 in TUG2 #1 to TUG2 #7.
TIM1I-TIM7I:
The TIM1I to TIM7I bits identify the source of trail trace identifier mismatch
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6), VT3 or TU12 (VT2) mode, the associated TIMxI bit is unused and will
return a logic 0 when read. When operational, the TIM1I to TIM7I bits report
and acknowledge TIM interrupt of TU #4 in TUG2 #1 to TUG2 #7,
respectively. Interrupts are generated upon change of identifier mismatch
state. An TIMxI bit is set high when a trail trace identifier mismatch event on
the corresponding tributary (TU #4 in TUG2 #x) occurs and are cleared
immediately following a read of this register, which also acknowledges and
clears the interrupt. TIMxI remains valid when interrupts are not enabled
(TIME set low) and may be polled to detect trail trace identifier mismatch
events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
250
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 424H, 464H, 4A4H: RTTB, TU3 or TU #1 in TUG2 #1 to TUG2 #7, TIU
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
TIU7I
0
Bit 5
R
TIU6I
0
Bit 4
R
TIU5I
0
Bit 3
R
TIU4I
0
Bit 2
R
TIU3I
0
Bit 1
R
TIU2I
0
Bit 0
R
TIU1I
0
This register is used to identify and acknowledge trail trace identifier unstable
interrupts for the tributaries TU #1 in TUG2 #1 to TUG2 #7. It is also used to
identify and acknowledge TU3 trail trace identifier unstable interrupts.
TIU1I:
The TIU1I bit identifies the source of trail trace identifier unstable interrupts.
In TU3 mode, The TIU1I bit reports and acknowledges TIU interrupt of the
TU3 trail trace identifier. Out of TU3 mode, TIU1I bit reports and
acknowledges TIU interrupt of TU #1 in TUG2 #1. Interrupts are generated
upon change of identifier unstable state. The TIU1I bit is set high when a trail
trace identifier unstable event and is cleared immediately following a read of
this register, which also acknowledges and clears the interrupt. the TIU1I bit
remains valid when interrupts are not enabled (TIUE set low) and may be
polled to detect trail trace identifier unstable events.
TIU2I-TIU7I:
The TIU2I to TIU7I bits identify the source of trail trace identifier unstable
interrupts. TIU2I to TIU7I bits report and acknowledge TIU interrupt of TU #1
in TUG2 #2 to TUG2 #7, respectively. Interrupts are generated upon change
of identifier unstable state. An TIUxI bit is set high when a trail trace identifier
unstable event on the corresponding tributary (TU #1 in TUG2 #x ) occurs
and are cleared immediately following a read of this register, which also
acknowledges and clears the interrupt. TIUxI remains valid when interrupts
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
251
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
are not enabled (TIUE set low) and may be polled to detect trail trace
identifier unstable events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
252
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 425H, 465H, 4A5H: RTTB, TU #2 in TUG2 #1 to TUG2 #7, TIU
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
TIU7I
0
Bit 5
R
TIU6I
0
Bit 4
R
TIU5I
0
Bit 3
R
TIU4I
0
Bit 2
R
TIU3I
0
Bit 1
R
TIU2I
0
Bit 0
R
TIU1I
0
This register is used to identify and acknowledge trail trace identifier unstable
interrupts for the tributaries TU #2 in TUG2 #1 to TUG2 #7.
TIU1I-TIU7I:
The TIU1I to TIU7I bits identify the source of trail trace identifier unstable
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6) mode, the associated TIUxI bit is unused and will return a logic 0 when
read. When operational, the TIU1I to TIU7I bits report and acknowledge TIU
interrupt of TU #2 in TUG2 #1 to TUG2 #7, respectively. Interrupts are
generated upon change of identifier unstable state. An TIUxI bit is set high
when a trail trace identifier unstable event on the corresponding tributary (TU
#2 in TUG2 #x ) occurs and are cleared immediately following a read of this
register, which also acknowledges and clears the interrupt. TIUxI remains
valid when interrupts are not enabled (TIUE set low) and may be polled to
detect trail trace identifier unstable events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
253
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 426H, 466H, 4A6H: RTTB, TU #3 in TUG2 #1 to TUG2 #7, TIU
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
TIU7I
0
Bit 5
R
TIU6I
0
Bit 4
R
TIU5I
0
Bit 3
R
TIU4I
0
Bit 2
R
TIU3I
0
Bit 1
R
TIU2I
0
Bit 0
R
TIU1I
0
This register is used to identify and acknowledge trail trace identifier unstable
interrupts for the tributaries TU #3 in TUG2 #1 to TUG2 #7.
TIU1I-TIU7I:
The TIU1I to TIU7I bits identify the source of trail trace identifier unstable
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6) or VT3 mode, the associated TIUxI bit is unused and will return a logic
0 when read. When operational, the TIU1I to TIU7I bits report and
acknowledge TIU interrupt of TU #3 in TUG2 #1 to TUG2 #7, respectively.
Interrupts are generated upon change of identifier unstable state. An TIUxI
bit is set high when a trail trace identifier unstable event on the corresponding
tributary (TU #3 in TUG2 #x ) occurs and are cleared immediately following a
read of this register, which also acknowledges and clears the interrupt. TIUxI
remains valid when interrupts are not enabled (TIUE set low) and may be
polled to detect trail trace identifier unstable events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
254
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 427H, 467H, 4A7H: RTTB, TU #4 in TUG2 #1 to TUG2 #7, TIU
Interrupt
Bit
Type
Bit 7
Function
Default
Unused
X
Bit 6
R
TIU7I
0
Bit 5
R
TIU6I
0
Bit 4
R
TIU5I
0
Bit 3
R
TIU4I
0
Bit 2
R
TIU3I
0
Bit 1
R
TIU2I
0
Bit 0
R
TIU1I
0
This register is used to identify and acknowledge trail trace identifier unstable
interrupts for the tributaries TU #4 in TUG2 #1 to TUG2 #7.
TIU1I-TIU7I:
The TIU1I to TIU7I bits identify the source of trail trace identifier unstable
interrupts. In TU3 mode, these bits are unused and will return a logic 0 when
read. When the corresponding TUG2 tributary group is configured for TU2
(VT6), VT3 or TU12 (VT2) mode, the associated TIMxI bit is unused and will
return a logic 0 when read. When operational, the TIU1I to TIU7I bits report
and acknowledge TIU interrupt of TU #4 in TUG2 #1 to TUG2 #7, respectively.
Interrupts are generated upon change of identifier unstable state. An TIUxI
bit is set high when a trail trace identifier unstable event on the corresponding
tributary (TU #4 in TUG2 #x ) occurs and are cleared immediately following a
read of this register, which also acknowledges and clears the interrupt. TIUxI
remains valid when interrupts are not enabled (TIUE set low) and may be
polled to detect trail trace identifier unstable events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
255
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 428H, 468H, 4A8H: RTTB, TIU Threshold
Bit
Type
Function
Default
Bit 7
R/W
TIU64[3]
0
Bit 6
R/W
TIU64[2]
1
Bit 5
R/W
TIU64[1]
1
Bit 4
R/W
TIU64[0]
1
Bit 3
R/W
TIU16[3]
0
Bit 2
R/W
TIU16[2]
1
Bit 1
R/W
TIU16[1]
1
Bit 0
R/W
TIU16[0]
1
This register contains threshold for declaration of the trail trace identifier unstable
alarm (TIU) for 16-byte and 64-byte tributary path trace messages.
TIU16[3:0]:
The 16-byte message trail trace identifier unstable threshold bits (TIU16[3:0])
controls level in the unstable counter at which to declare TIU. When ALGO2
is set low, each time a received message differs from the previous message,
the unstable counter is incremented. When the count exceeds TIU16, the TIU
alarm is declared. When ALGO2 is set high, a message that differs from the
previous initiates the unstable counter to count once per message. When the
count exceeds TIU16, the TIU alarm is declared. TIU is negated and the
unstable counter cleared when a consistent message is repeated three or five
times, as controlled by the PER5 bit, to become the accepted message.
TIU64[3:0]:
The 64-byte message trail trace identifier unstable threshold bits (TIU64[3:0])
controls level in the unstable counter at which to declare TIU. When ALGO2
is set low, each time a received message differs from the previous message,
the unstable counter is incremented. When the count exceeds TIU64, the TIU
alarm is declared. When ALGO2 is set high, a message that differs from the
previous initiates the unstable counter to count once per message. When the
count exceeds TIU64, the TIU alarm is declared. TIU is negated and the
unstable counter cleared when a consistent message is repeated three or five
times, as controlled by the PER5 bit, to become the accepted message.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
256
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 429H, 469H, 4A9H: RTTB, Indirect Tributary Select
Bit
Type
Function
Default
Bit 7
R/W
CPAGE
0
Bit 6
Unused
X
Bit 5
Unused
X
Bit 4
R/W
TUG2[2]
0
Bit 3
R/W
TUG2[1]
0
Bit 2
R/W
TUG2[0]
0
Bit 1
R/W
TU[1]
0
Bit 0
R/W
TU[0]
0
This register contains the identity of the tributary buffer to be accessed in an
indirect read or write operation.
TU[1:0]:
The tributary unit address bits (TU[1:0]) identifies the tributary within the
tributary unit group which is identified by the TUG2[2:0] bits. The combination
of TUG2[2:0] and TU[1:0] identifies the tributary buffer to be accessed
indirectly.
TUG2[2:0]:
The tributary unit group address bits (TUG2[2:0]) identifies the tributary unit
group. The combination of TUG2[2:0] and TU[1:0] identifies the tributary
buffer to be accessed indirectly.
CPAGE:
The capture page control bit (CPAGE) selects between accessing the capture
page and the expected page of the tributary buffer. When CPAGE is set high,
the indirect register access is targeted at the capture page. Reading from the
capture page returns the most recent tributary path trace message received
from the incoming stream. No de-bouncing is provided. When CPAGE is set
low, the indirect register access is targeted at the expected page. An
expected trace message can be provisioned by writing to the expected page.
Both the capture and expected pages may be read from or written to.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
257
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 42AH, 46AH, 4AAH: RTTB, Indirect Address Select
Bit
Type
Function
Default
Bit 7
R
BUSY
0
Bit 6
R/W
RWB
0
Bit 5
R/W
A[5]
0
Bit 4
R/W
A[4]
0
Bit 3
R/W
A[3]
0
Bit 2
R/W
A[2]
0
Bit 1
R/W
A[1]
0
Bit 0
R/W
A[0]
0
This register provides the byte address within the tributary buffer addressed by
the Indirect Tributary Select register. Writing to this register triggers an indirect
register access..
A[5:0]:
The indirect address bits (A[5:0]) index into the receive and expected pages
of the tributary buffers.
RWB:
The indirect access control bit (RWB) selects between a read and write
operation into the tributary buffers. Writing a logic zero to RWB triggers an
indirect write operation. The tributary buffer is selected by the TUG2[2:0] and
TU[1:0] bits in the Indirect Tributary register. Selection between the capture
page and the expected page is controlled by the CPAGE bit also in the
Indirect Tributary register. Bytes within the tributary buffer are indexed by
A[5:0]. Data to be written is taken from D[7:0] of the Indirect Data register.
Writing a logic one to RWB triggers an indirect read operation. Tributary
buffer, page, and byte addressing is the same as in an indirect write
operation. The data read can be found in D[7:0] of the Indirect Data register.
BUSY:
The indirect access status bit (BUSY) reports the progress of an indirect
access. BUSY is set high when this register is written to trigger an indirect
access and will stay high until the access is complete. At which point, BUSY
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
258
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
will be set low. This register should be polled to determine when data from an
indirect read operation is available in the Indirect Data register or to
determine when a new indirect write operation may commence.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
259
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 42BH, 46BH, 4ABH: RTTB, Indirect Data Select
Bit
Type
Function
Default
Bit 7
R/W
D[7]
0
Bit 6
R/W
D[6]
0
Bit 5
R/W
D[5]
0
Bit 4
R/W
D[4]
0
Bit 3
R/W
D[3]
0
Bit 2
R/W
D[2]
0
Bit 1
R/W
D[1]
0
Bit 0
R/W
D[0]
0
This register contains the data read from a tributary buffer after an indirect read
operation or the data to be inserted into a tributary buffer in an indirect write
operation.
D[7:0]:
The indirect data bits (D[7:0]) reports the data read from a tributary buffer
after an indirect read operation has complete. Data to be written to a tributary
buffer in an indirect write operation must be set up in this register before
triggering the write. Data in this register reflects the value written until the
completion of a subsequent indirect read operation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
260
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
10
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
TEST FEATURES DESCRIPTION
Simultaneously asserting (low) the CSB, RDB and WRB inputs when the MBEB
input is negated (high), causes all output pins and the data bus to be held in a
high-impedance state. This test feature may be used for board testing.
Test mode registers are used to apply test vectors during production testing of
the TUPP-PLUS. Test mode registers (as opposed to normal mode registers) are
selected when A[11] is high.
Test mode registers may also be used for board testing. When all of the tributary
payload processors within the TUPP-PLUS are placed in test mode 0, device
inputs may be read and device outputs may be forced via the microprocessor
interface (refer to the section "Test Mode 0" for details).
Table 2
- Test Mode Register Memory Map
Address
Register
000H-7FFH
Normal Mode Registers
800H
Master Test Register
801H
I/O Test register 1
802H
I/O Test register 2
803H
I/O Test register 3
804H
I/O Test register 4
805H
I/O Test register 5
806H-81FH
Reserved
820H
VTPP #1 Test Register 0
821H
VTPP #1 Test Register 2
822H
VTPP #1 Test Register 4
823H-83FH
Reserved
8A0H
VTPP #1 Test Register 1
8A1H
VTPP #1 Test Register 3
8A2H
VTPP #1 Test Register 5
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
261
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Address
Register
8A3H-8BFH
Reserved
840H
VTPP #2 Test Register 0
841H
VTPP #2 Test Register 2
842H
VTPP #2 Test Register 4
843H-85FH
Reserved
8C0H
VTPP #2 Test Register 1
8C1H
VTPP #2 Test Register 3
8C2H
VTPP #2 Test Register 5
8C3H-8DFH
Reserved
860H
VTPP #3 Test Register 0
861H
VTPP #3 Test Register 2
862H
VTPP #3 Test Register 4
863H-87FH
Reserved
8E0H
VTPP #3 Test Register 1
8E1H
VTPP #3 Test Register 3
8E2H
VTPP #3 Test Register 5
8E3H-8FFH
Reserved
900H
RTOP #1 Test Register 0
901H
RTOP #1 Test Register 1
902H
RTOP #1 Test Register 2
903H
RTOP #1 Test Register 3
904H
RTOP #1 Test Register 4
905H
RTOP #1 Test Register 5
906H
RTOP #1 Test Register 6
907H
RTOP #1 Test Register 7
908H
RTOP #1 Test Register 8
909H
RTOP #1 Test Register 9
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
262
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Address
Register
90AH
RTOP #1 Test Register 10
90BH
RTOP #1 Test Register 11
90CH
RTOP #1 Test Register 12
90DH
RTOP #1 Test Register 13
90EH
RTOP #1 Test Register 14
90FH
RTOP #1 Test Register 15
910H-9FFH
Reserved
A00H - A0FH
RTOP #2 Test Register 0 - 15
A10H-AFFH
Reserved
B00H - B0FH
RTOP #3 Test Register 0 - 15
B10H-BFFH
Reserved
C00H
RTTB #1 Test Register 0
C01H
RTTB #1 Test Register 1
C02H
RTTB #1 Test Register 2
C03H
RTTB #1 Test Register 3
C04H-C3FH
Reserved
C40H - C43H
RTTB #2 Test Register 0 - 3
C44H-C7FH
Reserved
C80H - C83H
RTTB #3 Test Register 0 - 3
C84H-FFFH
Reserved
Notes on Test Mode Register Bits:
1. Writing values into unused register bits has no effect. However, to ensure
software compatibility with future, feature-enhanced versions of the product,
unused register bits must be written with logic 0. Reading back unused bits
can produce either a logic 1 or a logic 0; hence unused register bits should be
masked off by software when read.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
263
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
2. Writable test mode register bits are not initialized upon reset unless otherwise
noted.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
264
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 800H: Master Test
Bit
Type
Function
Default
Bit 7
W
SSEL[1]
X
Bit 6
W
SSEL[0]
X
Unused
X
Bit 5
Bit 4
W
PMCTST
X
Bit 3
W
MOTOTST
X
Bit 2
R/W
IOTST
0
Bit 1
W
HIZDATA
X
Bit 0
R/W
HIZIO
0
This register is used to enable TUPP-PLUS test features. All bits, except
PMCTST, are reset to zero by a reset of the TUPP-PLUS.
HIZIO,HIZDATA:
The HIZIO and HIZDATA bits control the tri-state modes of the TUPP-PLUS .
While the HIZIO bit is a logic 1, all output pins of the TUPP-PLUS except the
data bus are held in a high-impedance state. The microprocessor interface is
still active. While the HIZDATA bit is a logic 1, the data bus is also held in a
high-impedance state which inhibits microprocessor read cycles.
IOTST:
The IOTST bit is used to allow normal microprocessor access to the test
registers and control the test mode in each TSB block in the TUPP-PLUS for
board level testing. When IOTST is a logic 1, all blocks are held in test mode
and the microprocessor may write to a block's test mode 0 registers to
manipulate the outputs of the block and consequently the device outputs
(refer to the "Test Mode 0 Details" in the "Test Features" section).
MOTOTST:
The MOTOTST bit is used to test the decoding of the RDB_E and WRB_RWB
control signals when MBEB is logic 0.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
265
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
PMCTST:
The PMCTST bit is used to configure the TUPP-PLUS for PMC's
manufacturing tests. When PMCTST is set to logic 1, the TUPP-PLUS
microprocessor port becomes the test access port used to run the PMC
"canned" manufacturing test vectors. The PMCTST bit is logically "OR'ed"
with the IOTST bit, and can only be cleared by setting CSB to logic 1.
SSEL[1:0]:
The test mode slice selection bits (SSEL[1:0]) controls CBI access to the
VTPP[3:1], RTOP[3:1] and RTTB[3:1], when PMCTST is set high. When
SSEL is set to 'b00, the selection among the TSBs is directly controlled by the
address bus A[11:0]. When SSEL is set to the three higher values, TSB
seletion is a combination of the address bus and the SSEL values. The
selection among the VTPP, RTOP and RTTB TSBs is made by setting the
address to the address range of VTPP #1, RTOP #1 and RTTB #1,
respectively. The choice of TSB slice #1, #2 and #3 is controlled by writing
'b01, 'b10 and 'b11, respectively, to the SSEL bits. The SSEL bits are cleared
by setting CSB to logic 1.
10.1
I/O Test Mode
In I/O test mode (IOTST in Master Test Register set high), the TUPP-PLUS
allows the logic levels on the device inputs to be read through the
microprocessor interface, and allows the device outputs to be forced to either
logic level through the microprocessor interface.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
266
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Test Register 801H: (Write in I/O test mode)
Bit
Type
Function
Default
Bit 7
W
OD[7]
X
Bit 6
W
OD[6]
X
Bit 5
W
OD[5]
X
Bit 4
W
OD[4]
X
Bit 3
W
OD[3]
X
Bit 2
W
OD[2]
X
Bit 1
W
OD[1]
X
Bit 0
W
OD[0]
X
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
267
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Test Register 802H: (Write in I/O test mode)
Bit
Type
Function
Default
Bit 7
W
ODP
X
Bit 6
W
OTPL
X
Bit 5
W
OTV5
X
Bit 4
W
AIS
X
Bit 3
W
IDLE
X
Bit 2
W
LC1J1V1
X
Bit 1
W
LPL
X
Bit 0
W
INTB
X
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
268
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Test Register 803H: (Write in I/O test mode)
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
W
POH[3]
X
Bit 4
W
POH[2]
X
Bit 3
W
POH[1]
X
Bit 2
W
POHFP[3]
X
Bit 1
W
POHFP[2]
X
Bit 0
W
POHFP[1]
X
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
269
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Test Register 804H: (Write in I/O test mode)
Bit
Type
Function
Default
Bit 7
Unused
X
Bit 6
Unused
X
Bit 5
W
POHEN[3]
X
Bit 4
W
POHEN[2]
X
Bit 3
W
POHEN[1]
X
Bit 2
W
POHCK[3]
X
Bit 1
W
POHCK[2]
X
Bit 0
W
POHCK[1]
X
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
270
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Test Register 805H: (Write in I/O test mode)
Bit
Type
Function
Default
Bit 7
W
COUT
X
Bit 6
W
RAD
X
Bit 5
W
LOM[3]
X
Bit 4
W
LOM[2]
X
Bit 3
W
LOM[1]
X
Bit 2
W
TPOH
X
Bit 1
Unused
X
Bit 0
Unused
X
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
271
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Test Register 801H: (Read in I/O test mode)
Bit
Type
Function
Default
Bit 7
R
ID[7]
X
Bit 6
R
ID[6]
X
Bit 5
R
ID[5]
X
Bit 4
R
ID[4]
X
Bit 3
R
ID[3]
X
Bit 2
R
ID[2]
X
Bit 1
R
ID[1]
X
Bit 0
R
ID[0]
X
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
272
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Test Register 802H: (Read in I/O test mode)
Bit
Type
Function
Default
Bit 7
R
SCLK
X
Bit 6
R
IC1J1
X
Bit 5
R
IPL
X
Bit 4
R
ITMF
X
Bit 3
R
IDP
X
Bit 2
R
OTMF
X
Bit 1
R
OC1J1
X
Bit 0
R
OPL
X
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
273
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Test Register 803H: (Read in I/O test mode)
Bit
10.2
Type
Function
Default
Bit 7
R
NSCLK
X
Bit 6
R
IBMODE
X
Bit 5
R
OBMODE
X
Bit 4
R
Reserved
X
Bit 3
R
Reserved
X
Bit 2
R
Reserved
X
Bit 1
R
Reserved
X
Bit 0
R
Reserved
X
JTAG Test Port
The TUPP-PLUS JTAG Test Access Port (TAP) allows access to the TAP
controller and the 4 TAP registers: instruction, bypass, device identification and
boundary scan. Using the TAP, device input logic levels can be read, device
outputs can be forced, the device can be identified and the device scan path can
be bypassed. For more details on the JTAG port, please refer to the Operation
section.
Table 3
- Instruction Register
Length - 3 bits
Instructions
Selected Register
Instruction Codes, IR[2:0]
EXTEST
Boundary Scan
000
IDCODE
Identification
001
SAMPLE
Boundary Scan
010
BYPASS
Bypass
011
BYPASS
Bypass
100
STCTEST
Boundary Scan
101
BYPASS
Bypass
110
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
274
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Instructions
Selected Register
Instruction Codes, IR[2:0]
BYPASS
Bypass
111
Identification Register
Length : 32 bits
Version number : 0x1
Part Number : 0x5362
Manufacturer's identification code : 0x0CD
Device identification : 0x153620CD
Boundary Scan Register
Length : 88 bits + 3 bit instruction register.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
275
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
11
OPERATION
11.1
Configuration Options
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
The TUPP-PLUS consists of three tributary payload processors (VTPPs), three
tributary path overhead processors (RTOPs) and three tributary trace buffers
(RTTBs). Each VTPP, RTOP and RTTB deals with a portion of the SONET frame
that corresponds to an STS-1 SPE. Equivalently, each VTPP, RTOP and RTTB
deals with a portion of the SDH frame that corresponds to a VC3 together with
the 2 columns of fixed stuff that are added when mapping a VC3 into an AU3. By
coordinating the operation of the three VTPPs, RTOPs and RTTBs, they can
process the portion of an SDH frame that corresponds to a VC4. The
coordination that may be required between the three VTPPs relates to the J1
byte marker and the encoding of the tributary multiframe into the H4 byte. When
processing a VC4 that carries three TUG3s, the alignment provided by the J1
byte marker and the H4 byte of the VC4 must be distributed to all VTPPs, RTOPs
and RTTBs. When processing STS-1 SPEs, or equivalently, VC3s carried within
AU3s, each VTPP, RTOP and RTTB receives its own J1 byte marker and H4
byte. Coordination is accomplished as follows: The tributary multiframe
alignment that is detected by VTPP #1 is distributed to the two other VTPPs
which do not receive valid H4 bytes. In addition, the input demultiplexer will
stretch the pulse captured on the IC1J1 input that marks the VC4 J1 byte so that
it marks the next two bytes. During the demultiplexing process this effectively
feeds a "J1" marker to the two "slaved" VTPPs.
The modes of operation of the TUPP-PLUS are summarized as follows:
STS-1 Mode: This is default. Each STS-1 is assumed to carry seven VT groups,
each of which can be independently configured to carry VT1.5s, VT2s, VT3s, or
VT6s. The IC1J1 input is expected to mark the J1 byte of each STS-1 SPE and
each VTPP detects the tributary multiframe encoded in the unique H4 byte that it
receives.
AU3 Mode: This is also the default, as is corresponds exactly to STS-1 mode,
except for nomenclature. Each AU3 is assumed to carry seven TUG2s, each of
which can be independently configured to carry TU11s, TU12s, or TU2s. (The
equivalent of a VT3 is allowed but there is no SDH nomenclature to describe
this.) The IC1J1 input is expected to mark the J1 byte of each VC3 and each
VTPP detects the tributary multiframe encoded in the unique H4 byte that it
receives.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
276
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
AU4 Mode: This mode is enabled when the ICONCAT and OCONCAT bits are set
high. In AU4 mode, individual VTPPs must be configured in either TUG3 mode
or TU3 mode. The IC1J1 input is expected to mark the J1 byte of the VC4. This
J1 marker is stretched to provide a "J1" marker to each VTPP. VTPP #2 and
VTPP#3 are slaved to the tributary multiframe indication provided by VTPP #1 as
it is the only one that receives a valid H4 byte.
TUG3 Mode: This mode is enabled when the TUG3 bit is set high in a VTPP. In
addition, the ICONCAT and OCONCAT bits must be set high for the TUPP-PLUS.
The TUG3 processed by the VTPP is assumed to carry seven TUG2s, each of
which can be independently configured to carry TU11s, TU12s, or TU2s. (The
equivalent of a VT3 is allowed but there is no SDH nomenclature to describe
this.) When the TUPP-PLUS is in AU4 mode, each VTPP can be independently
configured in TUG3 or TU3 mode.
TU3 Mode: This mode is enabled when the TU3 bit is set high in a VTPP. In
addition the ICONCAT and OCONCAT bits must be set high for the TUPP-PLUS.
The TUG3 processed by the VTPP is assumed to carry a TU3. When the
TUPP-PLUS is in AU4 mode, each VTPP can be independently configured in
TUG3 or TU3 mode.
For figures in the operation and functional timing sections (Figures 1 to 12),
transport overhead and path overhead bytes are shown for notational
convenience only. In the incoming direction, except for the H4 byte, ID[7:0] does
not need to contain valid transport and STS/AU path overhead byte values. The
H4 byte must be valid only if H4 framing is enabled (ITMFEN=0). Otherwise, it
too may be invalid. However, the incoming parity must match the data supplied
at all times. In the outgoing direction, TUPP-PLUS places random data on
OD[7:0] for transport overhead bytes. It generates all zero bytes for the STS/AU
path overhead except for the H4 byte which contains leading ones and an
incrementing two bit pattern. The fixed stuff bytes in the tributary mapping to the
synchronous payload envelope (virtual container) are also generated as all zero
bytes. The outgoing parity reflects the data on OD[7:0] at all times.
11.2
STS-1 Mode
An example of the placement of tributaries assumed in STS-1 mode is illustrated
in Figure 3. For simplicity, this figure shows the frame on the OD[7:0] bus when
OJ1EN is low. In this case the outgoing STS-1 SPEs are locked with respect to
the outgoing transport envelope frame. This particular example assumes a
snapshot of the first frame of the tributary multiframe when the V1 bytes are
present. This example illustrates a VT structured STS-1 SPE where all VT
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
277
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
groups are configured to carry VT1.5s. The more general case where OJ1EN is
high would be similar, except that the STS-1 SPE would be floating within the
transport envelope frame.
Figure 3
ROW 1
2
3
4
5
6
7
8
9
COL
1
2
A1 A1
B1
D1
H1 H1
B2 B2
D4
D7
D10 Z1
-
- SONET STS-3 Carrying VT1.5 Within STS-1
3
4
5
A1 A2 A2
E1
D2
H1 H2 H2
B2 K1
D5
D8
- D11 Z2
-
6
7
8
A2 C1 C1
F1
D3
H2 H3 H3
K2
D6
D9
- D12 E2
-
9
C1
H3
-
10
J1
B3
C2
G1
F2
H4
Z3
Z4
Z5
11
J1
B3
C2
G1
F2
H4
Z3
Z4
Z5
12
J1
B3
C2
G1
F2
H4
Z3
Z4
Z5
13
V1
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
14
V1
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
First of 3 columns occupied by
VT1.5 #1 of VT group #1 of
STS-1 #1 of an STS-3 stream
(column set is 13, 100, 187)
11.3
15
265
V1
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE • • • • SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
266
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
267
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
268
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
269
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
270
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
Last of 3 columns occupied by
VT1.5 #4 of VT group #7 of
STS-1 #3 of an STS-3 stream
(column set is 96, 183, 270)
AU3 Mode
An example of the placement of tributaries assumed in AU3 mode is illustrated in
Figure 4. For simplicity, this figure shows the frame on the OD[7:0] bus when
OJ1EN is low. In this case the outgoing VC3s are locked with respect to the
outgoing transport envelope frame. This particular example assumes a snapshot
of the last frame of the tributary multiframe when the V4 bytes are present. This
example illustrates the case where the VC3s carry TUG2s and all TUG2s are
configured to carry TU12s. The more general case where OJ1EN is high would
be similar, except that the VC3s would be floating within the transport envelope
frame.
Figure 4
ROW 1
2
3
4
5
6
7
8
9
COL
1
2
A1 A1
B1
D1
H1 H1
B2 B2
D4
D7
D10 Z1
-
- SDH STM-1 Carrying TU12 Within VC3/AU3
3
4
5
A1 A2 A2
E1
D2
H1 H2 H2
B2 K1
D5
D8
- D11 Z2
-
6
7
8
A2 C1 C1
F1
D3
H2 H3 H3
K2
D6
D9
- D12 E2
-
9
C1
H3
-
10
J1
B3
C2
G1
F2
H4
Z3
Z4
Z5
11
J1
B3
C2
G1
F2
H4
Z3
Z4
Z5
12
J1
B3
C2
G1
F2
H4
Z3
Z4
Z5
First of 4 columns occupied by
TU12 #1 of TUG2 #1 of VC3/
AU3 #1 of an STM-1 stream
(column set is 13, 76,142, 208)
13
V4
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
14
V4
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
15
265
V4
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE • • • • SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
266
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
267
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
268
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
269
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
270
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
Last of 4 columns occupied by
TU12 #3 of TUG2 #7 of VC3/
AU3 #3 of an STM-1 stream
(column set is 75, 141, 207, 270)
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
278
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
11.4
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
AU4 Mode
An example of the placement of tributaries assumed in AU4 mode is illustrated in
Figure 5. For simplicity, this figure shows the frame on the OD[7:0] bus when
OJ1EN is low. In this case the outgoing VC4 is locked with respect to the
outgoing transport envelope frame. This particular example assumes a snapshot
of the second frame of the tributary multiframe when the V2 bytes are present.
This example illustrates a case where the VC4 carries TUG3s, all TUG3s carry
TUG2s, and all TUG2s are configured to carry TU12s. The more general case
where OJ1EN is high would be similar, except that the VC4 would be floating
within the transport envelope frame.
Figure 5
ROW 1
2
3
4
5
6
7
8
9
COL
1
2
A1 A1
B1
D1
H1 H1
B2 B2
D4
D7
D10 Z1
-
- SDH STM-1 Carrying TU12 Within TUG3/AU4
3
4
5
A1 A2 A2
E1
D2
H1 H2 H2
B2 K1
D5
D8
- D11 Z2
-
6
7
8
A2 C1 C1
F1
D3
H2 H3 H3
K2
D6
D9
- D12 E2
-
9
C1
H3
-
10
J1
B3
C2
G1
F2
H4
Z3
Z4
Z5
11
19
V2
SPE
SPE
SPE
- • • • • SPE
SPE
SPE
SPE
SPE
First of 4 columns occupied by
TU12 #1 of TUG2 #1 of
TUG3 #1 of an STM-1 stream
(column set is 19, 82, 145, 208)
20
V2
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
265
21
V2
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE • • • • SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
266
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
267
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
268
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
269
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
270
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
Last of 4 columns occupied by
TU12 #3 of TUG2 #7 of
TUG3 #3 of an STM-1 stream
(column set is 81, 144, 207, 270)
Another example of the placement of tributaries assumed in AU4 mode is
illustrated in Figure 6. For simplicity, this figure shows the frame on the OD[7:0]
bus when OJ1EN is low. In this case the outgoing VC4 is locked with respect to
the outgoing transport envelope frame. This example illustrates the case where
the VC4 carries TUG3s that are all configured to carry TU3s. The more general
case where OJ1EN is high would be similar, except that the VC4 would be
floating within the transport envelope frame.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
279
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Figure 6
ROW 1
2
3
4
5
6
7
8
9
COL
1
2
A1 A1
B1
D1
H1 H1
B2 B2
D4
D7
D10 Z1
-
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- SDH STM-1 Carrying TU3 Within TUG3
3
4
5
A1 A2 A2
E1
D2
H1 H2 H2
B2 K1
D5
D8
- D11 Z2
-
6
7
8
A2 C1 C1
F1
D3
H2 H3 H3
K2
D6
D9
- D12 E2
-
9
C1
H3
-
10
J1
B3
C2
G1
F2
H4
Z3
Z4
Z5
11
-
12
-
13
H1
H2
H3
-
14
H1
H2
H3
-
15
H1
H2
H3
-
First of 86 columns occupied by
TU3 carried in TUG3 #1 of an
STM-1 stream
16 17 18
268
POH POH POH
SPE
POH POH POH
SPE
POH POH POH
SPE
POH POH POH
SPE
POH POH POH • • • • SPE
POH POH POH
SPE
POH POH POH
SPE
POH POH POH
SPE
POH POH POH
SPE
269
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
270
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
Last of 86 columns occupied by
TU3 carried in TUG3 #3 of an
STM-1 stream
Yet another example of the placement of tributaries assumed in AU4 mode is
illustrated in Figure 7. For simplicity, this figure shows the frame on the OD[7:0]
bus when OJ1EN is low. In this case the outgoing VC4 is locked with respect to
the outgoing transport envelope frame. This particular example assumes a
snapshot of the last frame of the tributary multiframe when the V4 bytes are
present. This example illustrates a complex case where the VC4 carries TUG3s
and where TUG3 #1 carries a TU3, TUG3 #2 carries TUG2s that are all
configured to carry TU11s, and TUG3 #3 carries TUG2s that are all configured to
carry TU12s. The more general case where OJ1EN is high would be similar,
except that the VC4 would be floating within the transport envelope frame.
Figure 7
ROW 1
2
3
4
5
6
7
8
9
COL
1
2
A1 A1
B1
D1
H1 H1
B2 B2
D4
D7
D10 Z1
-
- SDH STM-1 Carrying Mix Of TU11, TU12, TU3 Within TUG3/AU4
3
4
5
A1 A2 A2
E1
D2
H1 H2 H2
B2 K1
D5
D8
- D11 Z2
-
6
7
8
A2 C1 C1
F1
D3
H2 H3 H3
K2
D6
D9
- D12 E2
-
9
C1
H3
-
10
J1
B3
C2
G1
F2
H4
Z3
Z4
Z5
11
-
12
-
First of 86 columns occupied by
TU3 carried in TUG3 #1 of an
STM-1 stream
13
H1
H2
H3
-
14
H1
H2
H3
-
15
H1
H2
H3
-
16 17
POH POH POH POH POH POH POH POH POH -
18
-
19
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
First of 3 columns occupied by
TU11 #1 of TUG2 #1 of
TUG3 #2 of an STM-1 stream
(column set is 20, 104, 188)
20
V4
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
21
268
V4
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE • • • • SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
269
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
270
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
SPE
Last of 4 columns
occupied by TU12 #3
of TUG2 #7 of TUG3 #3
of an STM-1 stream
(column set is 81, 144, 207, 270)
In Figure 7 above, the H1 to H3 byte in column 13 form the TU3 offset pointer.
The H1 to H3 bytes in columns 14 and 15 are null pointer indications (NPI) for
TUG3 #2 and #3.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
280
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
11.5
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
JTAG Support
The TUPP-PLUS supports the IEEE Boundary Scan Specification as described
in the IEEE 1149.1 standards. The Test Access Port (TAP) consists of the five
standard pins, TRSTB, TCK, TMS, TDI and TDO, used to control the TAP
controller and the boundary scan registers. The TRSTB input is the active low
reset signal used to reset the TAP controller. TCK is the test clock used to
sample data on input, TDI and to output data on output, TDO. The TMS input is
used to direct the TAP controller through its states. The basic boundary scan
architecture is shown below.
Figure 8
- Boundary Scan Architecture
Boundary Scan
Register
TDI
Device Identification
Register
Bypass
Register
Instruction
Register
and
Decode
Mux
DFF
TDO
Control
TMS
Test
Access
Port
Controller
Select
Tri-state Enable
TRSTB
TCK
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
281
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
The boundary scan architecture consists of a TAP controller, an instruction
register with instruction decode, a bypass register, a device identification register
and a boundary scan register. The TAP controller interprets the TMS input and
generates control signals to load the instruction and data registers. The
instruction register with instruction decode block is used to select the test to be
executed and/or the register to be accessed. The bypass register offers a single
bit delay from primary input, TDI to primary output, TDO. The device
identification register contains the device identification code.
The boundary scan register allows testing of board inter-connectivity. The
boundary scan register consists of a shift register place in series with device
inputs and outputs. Using the boundary scan register, all digital inputs can be
sampled and shifted out on primary output, TDO. In addition, patterns can be
shifted in on primary input, TDI and forced onto all digital outputs.
11.5.1 TAP Controller
The TAP controller is a synchronous finite state machine clocked by the rising
edge of primary input, TCK. All state transitions are controlled using primary
input, TMS. The finite state machine is described below.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
282
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Figure 9
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- TAP Controller Finite State Machine
TRSTB=0
Test-Logic-Reset
1
0
1
1
Run-Test-Idle
1
Select-IR-Scan
Select-DR-Scan
0
0
0
1
1
Capture-IR
Capture-DR
0
0
Shift-IR
Shift-DR
0
1
0
1
1
1
Exit1-IR
Exit1-DR
0
0
Pause-IR
Pause-DR
0
1
0
0
1
0
Exit2-DR
Exit2-IR
1
1
Update-DR
1
0
Update-IR
1
0
All transitions dependent on input TMS
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
283
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Test-Logic-Reset:
The test logic reset state is used to disable the TAP logic when the device is in
normal mode operation. The state is entered asynchronously by asserting input,
TRSTB. The state is entered synchronously regardless of the current TAP
controller state by forcing input, TMS high for 5 TCK clock cycles. While in this
state, the instruction register is set to the IDCODE instruction.
Run-Test-Idle:
The run test/idle state is used to execute tests.
Capture-DR:
The capture data register state is used to load parallel data into the test data
registers selected by the current instruction. If the selected register does not
allow parallel loads or no loading is required by the current instruction, the test
register maintains its value. Loading occurs on the rising edge of TCK.
Shift-DR:
The shift data register state is used to shift the selected test data registers by
one stage. Shifting is from MSB to LSB and occurs on the rising edge of TCK.
Update-DR:
The update data register state is used to load a test register's parallel output
latch. In general, the output latches are used to control the device. For example,
for the EXTEST instruction, the boundary scan test register's parallel output
latches are used to control the device's outputs. The parallel output latches are
updated on the falling edge of TCK.
Capture-IR:
The capture instruction register state is used to load the instruction register with
a fixed instruction. The load occurs on the rising edge of TCK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
284
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Shift-IR:
The shift instruction register state is used to shift both the instruction register and
the selected test data registers by one stage. Shifting is from MSB to LSB and
occurs on the rising edge of TCK.
Update-IR:
The update instruction register state is used to load a new instruction into the
instruction register. The new instruction must be scanned in using the Shift-IR
state. The load occurs on the falling edge of TCK.
The Pause-DR and Pause-IR states are provided to allow shifting through the
test data and/or instruction registers to be momentarily paused.
The TDO output is enabled during states Shift-DR and Shift-IR. Otherwise, it is
tri-stated.
11.5.2 Boundary Scan Instructions
The following is a description of the standard instructions. Each instruction
selects an serial test data register path between input, TDI, and output, TDO.
BYPASS
The bypass instruction shifts data from input TDI to output TDO with one TCK
clock period delay. The instruction is used to bypass the device.
EXTEST
The external test instruction allows testing of the interconnection to other
devices. When the current instruction is the EXTEST instruction, the boundary
scan register is place between input TDI and output TDO. Primary device inputs
can be sampled by loading the boundary scan register using the Capture-DR
state. The sampled values can then be viewed by shifting the boundary scan
register using the Shift-DR state. Primary device outputs can be controlled by
loading patterns shifted in through input TDI into the boundary scan register
using the Update-DR state.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
285
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
SAMPLE
The sample instruction samples all the device inputs and outputs. For this
instruction, the boundary scan register is placed between TDI and TDO. Primary
device inputs and outputs can be sampled by loading the boundary scan register
using the Capture-DR state. The sampled values can then be viewed by shifting
the boundary scan register using the Shift-DR state.
IDCODE
The identification instruction is used to connect the identification register
between TDI and TDO. The device's identification code can then be shifted out
using the Shift-DR state.
STCTEST
The single transport chain instruction is used to test out the TAP controller and
the boundary scan register during production test. When this instruction is the
current instruction, the boundary scan register is connected between TDI and
TDO. During the Capture-DR state, the device identification code is loaded into
the boundary scan register. The code can then be shifted out on output TDO
using the Shift-DR state.
Table 4
Order #
- Boundary Scan Pin Order
Pin #
0
Pin name
Pin Type
ID value
HIZ
Output Enable
-
1
105
TPOH
Output
-
2
149
GSCLK[0]
Clock Output
-
3
144
LOM[1]
Output
-
4
141
LC1J1V1
Output
-
5
140
LPL
Output
-
6
139
POHEN[1]
Output
-
7
136
OTV5
Output
-
8
135
POH[1]
Output
-
9
134
OTPL
Output
-
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
286
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Order #
Pin #
Pin name
Pin Type
ID value
10
133
POHFP[1]
Output
-
11
126
POHCK
Clock Output
-
12
124
RAD
Output
-
13
115
IDLE
Output
-
14
114
AIS
Output
-
15
111
POHEN[2]
Output
-
16
110
OD[0]
Output
-
17
109
POH[2]
Output
-
18
108
OD[1]
Output
-
19
107
POHFP[2]
Output
-
20
106
OD[2]
Output
-
21
104
OD[3]
Output
-
22
97
OD[4]
Output
-
23
95
OD[5]
Output
-
24
93
OD[6]
Output
-
25
91
OD[7]
Output
-
26
90
LOM[2]
Output
-
27
89
ODP
Output
-
28
85
COUT
Output
-
29
77
POHEN[3]
Output
-
30
76
POH[3]
Output
-
31
67
POHFP[3]
Output
-
32
65
GSCLK[1]
Clock Output
-
33
63
LOM[3]
Output
-
34
28
INTB
OD Output
-
OENB[7]
OE
-
D[7]
I/O
-
OENB[6]
OE
-
35
36
37
26
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
287
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Order #
Pin #
Pin name
Pin Type
ID value
38
25
D[6]
I/O
-
OENB[5]
OE
-
D[5]
I/O
-
OENB[4]
OE
-
D[4]
I/O
-
OENB[3]
OE
-
D[3]
I/O
-
OENB[2]
OE
-
D[2]
I/O
-
OENB[1]
OE
-
D[1]
I/O
-
OENB[0]
OE
-
39
40
24
41
42
23
43
44
18
45
46
17
47
48
16
49
50
15
D[0]
I/O
-
51
157
A[9]
Input
-
52
156
A[10]
Input
-
53
153
SCLK
Clock Input
-
54
147
NSCLK
Clock Input
-
55
146
OBMODE
Input
-
56
145
IBMODE
Input
1
57
132
OPL
Input
0
58
127
OC1J1
Input
1
59
125
OTMF
Input
1
60
70
IDP
Input
0
61
68
ID[7]
Input
0
62
66
ID[6]
Input
1
63
64
ID[5]
Input
1
64
62
ID[4]
Input
0
65
60
ID[3]
Input
0
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
288
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Order #
Pin #
Pin name
Pin Type
ID value
66
58
ID[2]
Input
0
67
56
ID[1]
Input
0
68
54
ID[0]
Input
0
69
52
ITMF
Input
1
70
48
IPL
Input
0
71
44
IC1J1
Input
0
72
37
WRB_RWB
Input
0
73
35
RDB_E
Input
1
74
34
A[11]/TRS
Input
1
75
33
ALE
Input
0
76
31
RSTB
Input
1
77
14
MBEB
Input
1
78
13
CSB
Input
0
79
12
A[8]
Input
0
80
11
A[7]
Input
1
81
10
A[6]
Input
0
82
9
A[5]
Input
1
83
8
A[4]
Input
0
84
7
A[3]
Input
1
85
6
A[2]
Input
0
86
5
A[1]
Input
0
87
4
A[0]
Input
0
45
TCK
TAP Clock
47
TDI
TAP Input
49
TDO
TAP Output
51
TRSTB
TAP Input
53
TMS
TAP Input
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
289
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Notes :
1. A[0] is the first bit of the scan chain (closest to TDI).
2. OENB[n] sets the corresponding D[n] pin to an output when set low.
In the diagram of boundary scan cells, CLOCK-DR is connected to TCK when
the current controller state is SHIFT-DR or CAPTURE-DR, and unchanging
otherwise. The multiplexer in the centre of the diagram selects one of four inputs,
depending on the status of select lines G1 and G2. The ID Code bit is as listed in
the table above.
Figure 10
- Input Observation Cell (Input, Clock Input)
IDCODE
Scan Chain Out
INPUT
to internal
logic
Input
Pad
G1
G2
SHIFT-DR
I.D. Code bit
12
1 2 MUX
12
12
D
C
CLOCK-DR
Scan Chain In
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
290
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Figure 11
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- Output Cell (Output, Clock Output, Output Enable)
Scan Chain Out
G1
EXTEST
OUTPUT or Enable
f rom syst em logic
IDCODE
SHIFT - DR
I.D. code bit
1
G1
G2
1
1
1
1
2
2 MUX
2
2
1
OUTPUT or
Enable
MUX
D
C
D
C
CLOCK-DR
UPDA TE- DR
Scan Chain In
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
291
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Figure 12
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- Bidirectional Cell (IO_CELL)
Scan Chain Out
G1
EXTEST
OUTPUT from
internal logic
1
IDCODE
SHIFT-DR
INPUT
from pin
12
1 2 MUX
12
12
I.D. code bit
MUX
1
G1
G2
D
C
INPUT
to internal
logic
OUTPUT
to pin
D
C
CLOCK-DR
UPDATE-DR
Scan Chain In
Figure 13
- I/O Cell (I/O with OE pair)
Scan Chain Out
OUTPUT ENABLE
from internal
logic (0 = drive)
INPUT to
internal logic
OUTPUT from
internal logic
OUT_CELL
IO_CELL
I/O
PAD
Scan Chain In
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
292
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
12
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
FUNCTIONAL TIMING
The timing of the TUPP-PLUS input signals is illustrated in Figure 14. This
diagram shows a simple STS-3 case that outlines the function of the various
input signals. Data on ID[7:0] is sampled on the rising edge of SCLK. The bytes
forming the three STS-1 synchronous payload envelopes are identified by the
IPL signal being set high. The IC1J1 signal pulses high while IPL is low to mark
the position of the first C1 byte in the STS-3 transport envelope. The IC1J1
signal is set high for three SCLK periods while IPL is also set high to mark the J1
bytes of each STS-1 SPE. The ITMF signal is selectable to mark the third byte
after J1 of the first tributary in an STS-1 SPE or the H4 byte in the last (fourth)
frame of a tributary multiframe. In this diagram, ITMF is shown to be marking the
last H4 byte of the tributary multiframe in STS-1 #1 and STS-1 #3. The H4 byte
in STS-1 #2, as shown, is not last in the tributary multiframe. In this simple
example, all STS-1 SPEs are aligned to the STS-3 transport envelope such that
the J1 bytes directly follow the C1 bytes and no STS-1 pointer justification events
are occurring.
This same diagram applies for the AU3 mode as it is equivalent to the STS-1
mode, except for nomenclature.
Figure 14
- Input Bus Timing - Simple STS-1/AU3 Case
SCLK
IC1J1
••••
IPL
ITMF
(ITMFH4=1)
ID[7:0]
A1 A1 A1 A2 A2 A2 C1 C1 C1 J1 J1 J1
STS-1 #1 SPE J1 byte
H2 H3 H3 H3
H4 H4 H4
No stuffing
occuring
STS-1 #2 SPE J1 byte
STS-1 #3 SPE J1 byte
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
293
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Figure 15 shows a more complex STS-3 case that illustrates the flexibility
provided by the various input signals. Data on ID[7:0] is sampled on the rising
edge of SCLK. The bytes forming the three STS-1 synchronous payload
envelopes are identified by the IPL signal being set high. This example shows a
negative stuff event occurring on STS-1 #2 and a positive stuff event occurring
on STS-1 #3. The IC1J1 signal pulses high while IPL is low to mark the position
of the C1 byte of STS-1 #1. The IC1J1 signal pulses high again to mark the J1
byte of each of the three STS-1 SPEs. The ITMF signal is selectable to mark the
third byte after J1 in an STS-1 SPE or the H4 byte in the last (fourth) frame of a
tributary multiframe. In this diagram, ITMF is shown to be marking the V1 byte of
the first tributary multiframe in STS-1 #2. The three STS-1 SPEs are shown to
have different alignments to the STS-3 transport envelope and the alignment is
changing for two of the STS-1 SPEs (STS-1 #1 and #2) due to the pointer
justification events shown.
Again, this same diagram would apply for AU3 mode as it is equivalent to STS-1
mode, except for nomenclature.
Figure 15
- Input Bus Timing - Complex STS-1 / AU3 Case
SCLK
IC1J1
••••
IPL
ITMF
(ITMFH4=0)
ID[7:0]
A1 A1 A1 A2 A2 A2 C1 C1 C1 J1
STS-1 #1 SPE J1 byte
H1 H1 H1 H2 H2 H2 H3 J1 H3
V1
V1
Negative stuff byte
for STS-1 #2 SPE
which happens to
carry the J1 byte
V1 byte of first tributary in STS-1 #2
Positive stuff for STS-1 #3 SPE
V1 byte of second tributary in STS-1 #2
Figure 16 shows timing relationships of the various input signals in the AU4
mode. Data on ID[7:0] is sampled on the rising edge of SCLK. The bytes
forming the AU4 virtual container are identified by the IPL signal being set high.
This example shows a negative stuff occurring for the VC4. The IC1J1 signal
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
294
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
pulses high while IPL is set low to mark the position of the single C1 byte in the
STM-1 transport envelope. The ITMF signal is selectable to mark the third byte
after J1, or the H4 byte in the last (fourth) frame of a tributary multiframe. In this
diagram, ITMF is shown to be marking the final H4 byte of the tributary
multiframe. The IC1J1 signal pulses high to mark the single J1 byte of the VC4.
This diagram applies when the TUPP-PLUS is in AU4 mode, regardless of
whether individual tributary payload processors are configured for TUG3 or TU3
mode.
Figure 16
- Input Bus Timing - AU4 Case
SCLK
IC1J1
••••
IPL
ITMF
(ITMFH4=1)
ID7:0]
A1 A1 A1 A2 A2 A2 C1 X X H4
H1 H1 H1 H2 H2 H2
Negative stuff for VC4 which
happens to carry the J1 byte
The timing of the TUPP-PLUS output bus is illustrated in Figure 17. This diagram
shows the relationships of the output signals in locked STS-1 mode. Data on
OD[7:0] is updated on the rising edge of SCLK, and the OPL input must be logic
0. The OC1J1 signal pulses high to mark the position of the C1 byte of the first
STS-1 stream in every frame of the STS-3 transport envelope. In locked STS-1
mode, the position of the J1 bytes and the STS-1 SPEs is implicitly defined by
the C1 byte position. All three STS-1 SPEs are defined to be aligned to the STS3 transport envelope such that the J1 bytes immediately follow the C1 bytes and
no STS-1 pointer justification events are possible. This fixed implicit alignment is
reflected in the locked mode control signals LC1J1V1 and LPL. LC1J1V1 pulses
high to mark the first C1 byte, all three J1 bytes and the third byte after J1 of the
first tributary in each STS-1 stream. LPL identifies the SPE bytes on OD[7:0].
The OTMF input marks the frame containing V1 bytes. It is sampled only at the
first V1 byte position of the first STS-1 stream. The bytes forming the various
tributary synchronous payload envelopes are identified by the OTPL signal being
set high. The OTV5 signal pulses high to mark the V5 bytes of each outgoing
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
295
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
tributary. The TPOH signal marks the tributary path overhead bytes (V5, J2, Z6
and Z7) of each outgoing tributary.
This same diagram would apply for AU3 mode as it is equivalent to STS-1 mode,
except for nomenclature.
Figure 17
- Output Bus Timing - Locked STS-1 SPEs / AU3 VCs Case
SCLK
OC1J1
(OJ1EN=0)
OPL
OTMF
(OTMFH4=0)
••••
OTV5
OTPL
TPOH
LC1J1V1
LPL
OD[7:0]
A2 C1 C1 C1 J1 J1 J1 V1 V1 V1 V1 V1 V1 V1
Implicit location
of STS-1 SPE
J1 bytes
V1 byte VT #1, STS-1 #1
H1 H1 H1 H2 H2 H2 H3 H3 H3
J2 V5
No stuff events possible
J2 byte VT #1, STS-1 #1
V1 bytes VT #2
V5 byte VT #1, STS-1 #2
V1 byte VT #1, STS-1 #2
V1 byte VT #1, STS-1 #3
Figure 18 shows the function of the various output signals in floating STS-1
mode and AU3 mode. Data on OD[7:0] is updated on the rising edge of SCLK.
The bytes forming the three STS-1 synchronous payload envelopes are identified
by the setting the OPL signal high. In this diagram, a negative stuff event is
shown occurring on STS-1 #2 and a positive stuff event on STS-1 #3. The
OC1J1 signal pulses high, while OPL is set low, to mark the C1 byte of the first
STS-1 in every frame of the STS-3 transport envelope. The OC1J1 signal is set
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
296
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
high to mark every J1 byte of each of the three STS-1 SPEs. The OTMF input is
selectable to mark the third byte after J1 in each STS-1 SPE, or the H4 byte in
the last (fourth) frame of a tributary multiframe. In this diagram, OTMF is shown
to be marking the last H4 byte of the tributary multiframe in STS-1 #1. The bytes
forming the various tributary synchronous payload envelopes are identified by
the OTPL signal being set high. The OTV5 signal pulses high to mark the V5
bytes of each outgoing tributaries. The TPOH signal pulses high to mark the
tributary path overhead bytes (V5, J2, Z6 and Z7) of each outgoing tributaries.
OTPL, OTV5 and TPOH are invalid when OPL is set low. The three STS-1 SPEs
each have different alignments to the STS-3 transport envelope and the
alignment is changing for two of the STS-1 SPEs (STS-1 #2 and #3) due to the
pointer justification events shown. In floating mode, LC1J1V1 and LPL are held
low and are not shown in Figure 18.
Figure 18
- Output Bus Timing - Floating STS-1 SPEs / AU3 VCs Case
SCLK
OC1J1
(OJ1EN=1)
••••
OPL
OTMF
(OTMFH4=1)
OTV5
OTPL
TPOH
OD[7:0]
INVALID
INVALID
IV
IV
INVALID
INVALID
IV
IV
INVALID
INVALID
IV
IV
A1 A1 A1 A2 A2 A2 C1 C1 C1 J1 C2 H4 Vx
STS-1 #1 SPE J1 byte
Last H4 byte in
tributary multiframe
Any V1 - V4 byte
TU#1, STS-1 #1
H1 H1 H1 H2 H2 H2 H3 H4 H3 G1
V5
Negative stuff for STS-1 #2
SPE which happens to
carry a non-final H4 byte
Positive stuff for STS-1 #3 SPE
V5 byte as marked by OTV5
The timing of the TUPP-PLUS output signals in locked and floating AU4 modes is
illustrated in Figure 19 and Figure 20, respectively. The operation of the various
signals is analogous to the locked and floating STS-1 modes, except that there is
only a single J1 byte and all pointer justification events must involve a group of
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
297
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
three stuff bytes. These diagrams apply when the TUPP-PLUS is in AU4 mode,
regardless of whether individual tributary payload processors are configured for
TUG3 or TU3 mode.
Figure 19 shows the case of the TUPP-PLUS operating in locked AU4 mode.
Data on OD[7:0] is updated on the rising edge of SCLK, and the OPL input must
be logic 0. The OC1J1 signal pulses high to mark the position of the single C1
byte in every frame of the AU4 transport envelope. In locked AU4 mode, the
position of the single J1 byte and the VC4 is implicitly defined by the C1 byte
position. The VC4 is defined to be aligned to the AU4 transport envelope such
that the J1 byte occupies the first available payload byte after the C1 byte, and
no pointer justification events are possible. This fixed implicit alignment is
reflected in the locked mode control signals LC1J1V1 and LPL. LC1J1V1 pulses
high to mark the first C1 byte, the J1 byte and the third byte after J1 of the first
tributary in the AU4 stream. LPL identifies the payload bytes on OD[7:0]. The
OTMF input marks the frame containing V1 bytes. It is sampled only at the J1
plus one byte position of the first TUG3 stream. The bytes forming the various
tributary synchronous payload envelopes are identified by the OTPL signal being
set high. The OTV5 signal pulses high to mark the V5 bytes of each outgoing
tributary. The TPOH signal pulses high to mark the tributary path overhead bytes
(V5, J2, Z6 and Z7) of each outgoing tributary.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
298
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Figure 19
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- Output Bus Timing - Locked AU4 VC Case
S C LK
O C 1J1
(O J1E N =0)
••••
O P L=0
O TM F
(O TM F H 4=0 )
O TV 5
O TP L
TP O H
LC 1J1V 1
LP L
O D [7:0 ]
A2 C1 X
X J1
R
R
R
R
R
N ation al
bytes
Im p licit loca tio n
of V C 4 J1 byte
First R c olum n of TU G 3 # 1
V 1 b yte TU #1 , TU G 2 # 1, TU G 3 # 1
R V1
H4
La st H 4 b yte
in tribu tary
m ultifram e
R
R
R
R
R
R V5
Z6
Fixed
S tuff
C olum ns
V 5 b yte TU #1 ,
TU G 2 # 1 , TU G 3 #1
Z6 b yte TU #1 ,
TU G 2 # 1 , TU G 3 #3
Figure 20 shows the function of the various output signals in floating AU4 mode.
Data on OD[7:0] is updated on the rising edge of SCLK. The bytes forming the
VC4 virtual container are identified by the setting the OPL signal high. The
OC1J1 signal pulses high, while OPL is set low, to mark the single C1 byte in
every frame of the AU4 transport envelope. The OC1J1 signal is set high again
with OPL high to mark the J1 byte of the VC4. The OTMF input is selectable to
mark the third byte after J1 in the VC4, or the H4 byte in the last (fourth) frame of
a tributary multiframe. In this diagram, OTMF is shown to be marking the first V1
byte. The bytes forming the various tributary synchronous payload envelopes are
identified by the OTPL signal being set high. The OTV5 signal pulses high to
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
299
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
mark the V5 bytes of each outgoing tributaries. The TOPH signal pulses high to
mark the tributary overhead bytes of each outgoing tributaries.
Figure 20
- Output Bus Timing - Floating AU4 VC Case
S C LK
O C 1J1
(O J1E N =1)
••••
OPL
O TM F
(O TM F H 4=0 )
O TV 5
IN V A L ID
O TP L
IN V A L ID
TP O H
IN V A L ID
D O U T[7:0]
A1 A2 A2 A2 C1 X
X
N ation al bytes
V 5 byte TU G 3 #1
Z7 byte TU G 3 # 1
V5
Z7
J1
NP NP NP
V1 V1 V1
J1 byte V C 4
Firs t N P I b yte TU G 3 # 1
V 1 byte TU #1 ,
TU G 2 #1 , TU G 3 #1
The three tributary payload processor may be individually disabled. Incoming
data destined to a disabled processor is re-transmitted unchanged to the
outgoing data after some delay. The amount of delay is dependent on the
relative phase of the incoming frame pulse (IC1J1) and the outgoing frame pulse
(OC1J1). Figure 21 shows the delay for the three possible alignments of IC1J1
in relation to OC1J1 in byte interface mode. The delay from the rising edge of
SCLK where TUPP-PLUS samples ID[7:0] to the rising edge of SCLK where a
downstream device samples OD[7:0] is 5, 6, or 7 cycles. Figure 22 shows the
alignment of the data to the frame pulses IC1J1 and OC1J1 in nibble interface
mode. The more significant nibble on ID[3:0] and OD[3:0] is transmitted first and
is marked by the C1 and J1 pulses. The possible delay values ranges from 11 to
16 NSCLK cycles. The minimum and maximum delay scenarios are shown in
Figure 22.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
300
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Figure 21
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- Byte Interface, By-passed Mode Functional Timing
SCLK
IC1J1
OC1J1
DIN[7:0]
5 byte
delay
DOUT[7:0]
A2 C1 C1 C1
A1 A1 A1 A2 A2 A2 C1 C1 C1
SCLK
IC1J1
OC1J1
DIN[7:0]
6 byte
delay
DOUT[7:0]
A2 C1 C1 C1
A1 A1 A1 A2 A2 A2 C1 C1 C1
SCLK
IC1J1
OC1J1
DIN[7:0]
7 byte
delay
DOUT[7:0]
A2 C1 C1 C1
A1 A1 A1 A2 A2 A2 C1 C1 C1
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
301
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Figure 22
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- Nibble Interface, By-passed Mode Functional Timing
NSCLK
IC1J1
OC1J1
ID[3:0]
OD[3:0]
A2
A1
C1
A1
C1
C1
A1
B522 B522 B522 B523 B523 B523
A2
A2
A2
C1
C1
C1
B522
NSCLK
IC1J1
OC1J1
ID[3:0]
OD[3:0]
A2
C1
C1
B521 B521 B521
C1
A1
B522 B522 B522 B523 B523 B523
A1
A1
A2
A2
A2
C1
The tributary overhead serial interface is shown in Figure 23. The tributary path
overhead bytes in each of the STS-1 (AU3) or TUG3 streams on ID[7:0] are
individually serialized on POH[3:1]. The most significant bit of the V5 byte of the
first tributary (TU#1, TUG2 #1) of each STS-1 stream is identified by a logic high
value on the corresponding POHEN[3:1] output. All four tributary path overhead
bytes (V5, J2, Z6, Z7) are shifted out once per payload frame. Since the nominal
arrival rate of overhead is once per multiframe, each overhead byte is presented
on POH an average of four times. To distinguish the first presentation of an
overhead byte from subsequent repeat presentations, the corresponding
POHEN[3:1] output is set high to mark a fresh byte and set low to mark a stale
byte. POHCK provides timing for the POH[3:1], POHFP[3:1] and POHEN[3:1]
outputs. POHCK[3:1] are 9.72 MHz clocks and run continuously.
Tributaries on POH are arranged in the order of transmission as in the incoming
data stream ID[7:0]. I.e., TU #1 of TUG2 #1, TU#1 of TUG2 #2, ... TU #1 of
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
302
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
TUG2 #7, TU #2 of TUG2 #1, ... TU #2 of TUG2 #7, TU #3 of TUG2 #1, ... TU #4
of TUG2 #7. Timeslot assignment on POH is unrelated to the configuration of the
tributary group. Timeslots for four tributaries are always reserved for any tributary
group even if it is configured for TU12, VT3 or TU2. At timeslots devoted to nonexistent tributaries, for example, tributary 2, 3 and 4 of a TUG2 configured for
TU2, POH and POHEN will be set low. The path overhead frame pulse, POHFP,
identifies the most significant bit of the first tributary (TU #1 of TUG2 #1) on POH.
In TU3 mode, the POH stream carry the nine path overhead bytes. The bytes are
shifted out twice per payload frame. The assignment of TU3 POH bytes to lower
order tributary overhead timeslots shown in Figure 13 are:
TU3, J1
-> TU #1, TUG2 #1, V5 and TU #3, TUG2 #1, V5
TU3, B3
-> TU #1, TUG2 #1, J2 and TU #3, TUG2 #1, J2
TU3, C2
-> TU #1, TUG2 #1, Z6 and TU #3, TUG2 #1, Z6
TU3, G1
-> TU #1, TUG2 #1, Z7 and TU #3, TUG2 #1, Z7
TU3, F2
-> TU #1, TUG2 #2, V5 and TU #3, TUG2 #2, V5
TU3, H4
-> TU #1, TUG2 #2, J2 and TU #3, TUG2 #2, J2
TU3, Z3
-> TU #1, TUG2 #2, Z6 and TU #3, TUG2 #2, Z6
TU3, Z4
-> TU #1, TUG2 #2, Z7 and TU #3, TUG2 #2, Z7
TU3, Z5
-> TU #1, TUG2 #3, V5 and TU #1, TUG2 #3, V5
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
303
P O H [3:1]
P O H E N [3:1]
Z7
T U #1 , T U G 2 #2
Z6
J2
Z7
T U #1 , T U G 2 # 1,J 2 B Y T E
V5
T U #1 , T U G 2 #3
Z6
J2
•••
T U #1 , T U G 2 #1, Z 6 B Y T E
V5
V5
T U #4 , T U G 2 #7
Z6
J2
T U #1 , T U G 2 #1, Z 7 B Y T E
Z7
Z7
X
X B1 B2 B3 B4 B5 B6 B7 B8 B1 B2 B3 B4 B5 B6 B7 B8 B1 B2 B3 B4 B5 B6 B7 B8 B1 B2 B3 B4 B5 B6 B7 B8 B1 B2 B3
T U #1 , T U G 2 #1 , V 5 B Y T E
T U #1 , T U G 2 #1
Z6
J2
Figure 23
P O H F P [3:1]
V5
ISSUE 6
PO H CK
X
PMC-951010
P O H F P [3:1]
P O H C K [3:1]
PM5362 TUPP-PLUS
DATA SHEET
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- Tributary Path Overhead Serialization Functional Timing
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
304
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Figure 24 shows the timing of the receive alarm port. Timing is provided by the
POHCK[1] output which is a continuous 9.72 MHz clock. The BIP-2, RDI,
auxiliary RDI, PDI and LOM indications of all the tributaries in the incoming
stream are combined and reported on the RAD output. The bits labeled B1 and
B2 reports the number of BIP-2 errors. If the number of BIP-2 errors is one, only
one of B1 is set high. Both B1 and B2 are set high when two BIP-2 errors are
detected. The bit labeled R and AR reports the remote defect indication (RDI)
and auxiliary remote defect indication (ARDI) status of the associated tributary.
They are set high due to incoming AIS, LOP, PLSM, PSLU, TIM, TIU and LOM.
The bit labeled P report the path defect indication (PDI-P) due to tributary path
defect indication PDI-V, AIS, LOP and UNEQ states. The PDI-P indications allow
a downstream device where the tributaries are aggregated into an SPE to form a
C2 byte containing the count of tributaries in alarm state. The bit labeled L
reports the loss of multiframe state. Tributaries timeslots on RAD are arranged in
the order of transmission as in the incoming data stream ID[7:0]. I.e., TU #1 of
TUG2 #1 TUG3 #1, TU #1 of TUG2 #1 TUG3 #2, TU #1 of TUG2 #1 TUG3 #3,
TU#1 of TUG2 #2 TUG3 #2, ... TU #1 of TUG2 #7 TUG3 #3, TU #2 of TUG2 #1
TUG3 #1, ..., TU #2 of TUG2 #7 TUG3 #3, ..., TU #4 of TUG2 #7 TUG3 #3.
Timeslot assignment on RAD is unrelated to the configuration of the tributary
group. Timeslots for four tributaries are always reserved for any tributary group
even if it is configured for TU12, VT3 or TU2. At timeslots devoted to non-existent
tributaries, for example, tributary 2, 3 and 4 of a TUG2 configured for TU2, RAD
will be set low. The path overhead frame pulse, POHFP[1], identifies the BIP-2
error indication for the odd-numbered bits of the first tributary (TU #1 of TUG2 #1
STS-1 #1) on RAD.
When a TUG3 stream is configured in TU3 mode, the segregation of RAD, for
that TUG3, into tributary timeslots are dissolved. Any bit normally carrying
tributary BIP-2 indications may carry a TU3 BIP-8 error indication. All remaining
bits will report the associated state of the TU3 stream simultaneously.
When a TUG3 is bypassed by setting corresponding TUGEN bit in the VTPP
Configuration register low, no performance monitoring is performed on that TUG3
stream. Consequently, the timeslots associated with the bypassed stream on the
RAD stream are invalid.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
305
RAD
B1 B2
R
AR P
T U # 1,
TUG 2 #1,
TU G 3 #1
L
B1 B2 R
AR
P
T U # 1,
TU G 2 #1,
TU G 3 #2
L
B1 B2 R
AR
T U # 1,
TUG 2 #1,
TU G 3 #3
P
L
T U #1, T U G 2 #4
TUG 3 TU G 3
#1
#2
•••
B1 B2 R
L
X
B1 B2 R
T U # 1,
TUG 2 #2,
TU G 3 #2
T U #4, T U G 2 #7
TUG 3 TU G 3 TUG 3
#3
#1
#2
AR P
T U # 1,
TU G 2 #2,
TUG 3 #1
T U #4, T U G 2 #6
TUG 3 TUG 3
#3
#2
Figure 24
P O H F P [1]
T U #1 , T U G 2 #1
T U #1 , T U G 2 #3
T U #1, T U G 2 #2
TUG 3 TU G 3
TU G 3 TUG 3 TUG 3 TUG 3 TU G 3 TUG 3 TUG 3
#1
#3
#2
#3
#2
#2
#1
#1
#3
ISSUE 6
POH CK
X
PMC-951010
P O H F P [1]
P O H C K [1]
PM5362 TUPP-PLUS
DATA SHEET
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- Receive Alarm Port Functional Timing
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
306
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Figure 25 illustrates the input and output timing in nibble interface mode. For
each byte on the incoming data stream ID[3:0], the more significant nibble is
transmitted first, followed by the less significant nibble. The more significant
nibble of the C1 byte on ID[3:0] is marked by a high pulse on IC1J1 while IPL is
set low. IC1J1 is always set low at the less significant nibble of any byte.
Similarly, the more significant nibble of the J1 byte(s) is (are) marked by a high
pulse on IC1J1 while IPL is set high. IPL is only meaningful during the more
significant nibble of each incoming data byte and is ignored during the less
significant nibble. The first frame of each incoming tributary multiframe is marked
by a pulse on ITMF. ITMF is only meaningful during the more significant nibble
and is ignored during the less significant nibble.
The outgoing data stream OD[3:0] behaves similarly to the incoming data
stream. The more significant nibble of each byte is transmitted first, followed by
the less significant nibble. The more significant nibble of the C1 byte on OD[3:0]
is marked by a high pulse on OC1J1 while OPL is set low. OC1J1 is always set
low at the less significant nibble of any byte. Similarly, the more significant nibble
of the J1 byte(s) is (are) marked by a high pulse on OC1J1 while OPL is set high.
OPL is only meaningful during the more significant nibble of each incoming data
byte and is ignored during the less significant nibble. The first frame of each
incoming tributary multiframe is marked by a pulse on OTMF. OTMF is only
meaningful during the more significant nibble and is ignored during the less
significant nibble. The OTV5 output identifies both nibbles of the V5 bytes on the
outgoing stream while OTPL identifies both nibbles of tributary payload bytes. All
tributary path overhead bytes are identified by the TPOH signal. The LC1J1V1
output marks the transport frame, payload frame and tributary multiframe
boundaries on OD[3:0] when the TUPP-PLUS is operating in locked mode. It will
only pulse high during the more significant nibble of the identified bytes and will
be set low during the less significant nibble of any byte. The LPL output identifies
payload bytes on OD[3:0]. LPL is set to the same value on both the more and
less significant nibbles.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
307
ISSUE 6
PM5362 TUPP-PLUS
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
OTV5
TPOH
OTPL
LPL
LC1J1V1
V3
V2
V1
J1
J1
J1
C1
C1
C1
A2
A2
A2
A1
A1
A1
OD[3:0] B520 B521
V3
V2
V1
J1
J1
J1
C1
C1
C1
A2
A2
A2
A1
A1
A1
B520 B521
ID[3:0]
DATA SHEET
ITMF/
OTMF
308
- Nibble Interface Mode Input/Output Functional Timing
IPL/
OPL
PMC-951010
Figure 25
IC1J1/
OC1J1
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
NSCLK
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
13
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
APPLICATION EXAMPLES
The TUPP-PLUS is typically used as part of a SONET/SDH tributary crossconnect. The TUPP-PLUS can be used to transfer the payloads of incoming
tributaries into outgoing tributaries that are aligned to facilitate switching. A
typical example is illustrated in Figure 26. This example shows the tributaries
extracted from an STS-1 or AU3 path terminating device, such as the PM5344
SPTX SONET/SDH Path Terminating Transceiver, being routed through TUPPPLUS so as to be aligned for cross-connection using the PM5371 TUDX
SONET/SDH Tributary Unit Cross-Connect. The TUPP-PLUS (and SPTX) can
be bypassed by switching through whole STS-1s or AU3s that are output by the
SPTX through a delay that matches the delay between the C1 pulse on IC1J1
and the C1 pulse on OC1J1. Note that in this application example, the TUPPPLUS is operating in locked output mode (i.e. their OJ1EN bits are low) to allow
convenient interfacing to the TUDX.
Figure 26
- SONET/SDH Tributary Cross-Connect Application
From PM5344
SPTX #2
DELAY
From PM5344
SPTX #1
DELAY
PM5362
TUPP-PLUS
From PM5344
SPTX #1
SCLK
OTMF
IC1J1
OC1J1
IPL
OPL
ITMF
OD[7:0]/ODP
ID[7:0]/IDP
SINL
OTPL
SCLK
OTV5
SFP
From PM5344
SPTX #2
OTMF
OFSEB
IC1J1
OC1J1
SOBEB
ITMF
ID[7:0]/IDP
OPL
OFP
SOUTL
SOUTR
DINR
SCLK
IPL
IFP
PM5371
TUDX
DINL
PM5362
TUPP-PLUS
SINR
DOUTL
ODEB
AOBEB
DOUTR
OD[7:0]/ODP
OTPL
OTV5
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
To PM5344
SPTX #2
To PM5344
SPTX #1
309
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
14
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
ABSOLUTE MAXIMUM RATINGS
Maximum rating are the worst case limits that the device can withstand without
sustaining permanent damage. They are not indicative of normal operating
conditions.
Table 5
- TUPP-PLUS Absolute Maximum Ratings
Ambient Temperature under Bias
-40°C to +85°C
Storage Temperature
-40°C to +125°C
Supply Voltage
-0.5V to +6.0V
Voltage on Any Pin
-0.5V to VDD+0.5V
Static Discharge Voltage
±1000 V
Latch-Up Current
±100 mA
DC Input Current
±20 mA
Lead Temperature
+220°C
Absolute Maximum Junction Temperature
+150°C
Power Dissipation
1.5 W
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
310
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
15
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
D.C. CHARACTERISTICS
(TA = -40°C to +85°C, VDD = 5 V ±10%)
Table 6
- TUPP-PLUS D.C. Characteristics
Symbol
Parameter
Min
VIL
Input Low
Voltage
VIH
Input High
Voltage
VOL
Output or
Bidirectional
Low Voltage
VOH
Output or
Bidirectional
High Voltage
VT+
Reset Input
High Voltage
VT-
Reset Input
Low Voltage
VTH
Reset Input
Hysteresis
Voltage
IILPU
Input Low
Current
(Pull-ups)
Typ
Max
Units
Conditions
-0.5
0.8
Volts
Guaranteed Input
LOW Voltage
2.0
VDD
+0.5
Volts
Guaranteed Input
HIGH Voltage
0.4
Volts
IOL = -8 mA for INTB,
D[7:0], POHCK and
GSCLK[1]
IOL = -4 mA for all
others
Note 3
VDD1.0
Volts
IOH = 8 mA for INTB,
D[7:0], POHCK and
GSCLK[1]
IOH = 4 mA for all
others
Note 3
3.5
Volts
0.6
0.5
+100
+35
0
Volts
Volts
+525
µA
VIL = GND, Notes 1, 3
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
311
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Symbol
Parameter
Min
Typ
Max
Units
Conditions
IIHPU
Input High
Current (Pullups)
-10
0
+10
µA
VIH = VDD, Notes 1, 3
IIL
Input Low
Current
-10
0
+10
µA
VIL = GND, Notes 2, 3
IIH
Input High
Current
-10
0
+10
µA
VIH = VDD, Notes 2, 3
CIN
Input
Capacitance
5
pF
Excluding Package,
Package Typically 2
pF
COUT
Output
Capacitance
5
pF
Excluding Package,
Package Typically 2
pF
CIO
Bidirectional
Capacitance
5
pF
Excluding Package,
Package Typically 2
pF
IDDOP1
Operating
Current
Processing
Tributaries
185
mA
VDD = 5.5 V, Outputs
Unloaded, SCLK =
19.44 MHz,
Alternating Data,
Processing Tributaries
IDDOP2
Operating
Current
Tributary
Processing
Disabled
80
mA
VDD = 5.5 V, Outputs
Unloaded, SCLK =
19.44 MHz,
Alternating Data,
Tributary Processors
Bypassed
Notes on D.C. Characteristics:
1. Input pin or bidirectional pin with internal pull-up resistor.
2. Input pin or bidirectional pin without internal pull-up resistor
3. Negative currents flow into the device (sinking), positive currents flow out of
the device (sourcing).
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
312
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
4. Input pin or bidirectional pin with internal pull-down resistor.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
313
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
16
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
MICROPROCESSOR INTERFACE TIMING CHARACTERISTICS
(TA = -40°C to +85°C, VDD = 5 V ±10%)
Table 7
- Microprocessor Interface Read Access (Figure 27, Figure 28)
Symbol
Parameter
Min
Typ
Max
tSAR
Address to Valid Read
Set-up Time
25
ns
tHAR
Address to Valid Read
Hold Time
25
ns
tSRWB
RWB to Valid Read Setup Time
25
ns
tHRWB
RWB to Valid Read Hold
Time
tSALR
Address to Latch Set-up
Time
20
ns
tHALR
Address to Latch Hold
Time
20
ns
tVL
Valid Latch Pulse Width
20
ns
tSLR
Latch to Read Set-up
0
ns
tHLR
Latch to Read Hold
20
ns
tPRD
Valid Read to D[7:0] Valid
80
ns
tZRD
Valid Read Negated to
Output Tri-state
20
ns
tZINTH
Valid Read Negated to
INTB High
70
ns
10
Units
ns
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
314
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Figure 27
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- Microprocessor Interface Read Timing (Intel Mode)
tSAR
A[7:0]
Valid
Address
tHAR
tS ALR
tV L
tHALR
ALE
tHLR
tS LR
(CSB+RDB)
tZ INTH
INTB
tPRD
D[7:0]
tZ RD
Valid Data
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
315
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Figure 28
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- Microprocessor Interface Read Timing (Motorola Mode)
tS AR
Valid
A[7:0]
Address
RWB
tS RWB
tHRWB
tS ALR
tV L
tHALR
tHAR
ALE
tHLR
tS LR
(!CSB & E)
tZ INTH
INTB
tZ RD
tPRD
D[7:0]
Valid Data
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
316
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Notes on Microprocessor Interface Read Timing:
1. Output propagation delay time is the time in nanoseconds from the 1.4 Volt
point of the reference signal to the 1.4 Volt point of the output.
2. Maximum output propagation delays are measured with a 100 pF load on the
Microprocessor Interface data bus, (D[7:0]).
3. a. In Intel mode, a valid read enable bar is defined as a logical OR of the CSB
and the RDB signals.
b. In Motorola mode, a valid read enable is defined as a logical AND of the E
signal, the RWB signal, and the inverted CSB signal.
4. Microprocessor Interface timing applies to normal mode register accesses
only.
5. In non-multiplexed address/data bus architectures, ALE should be held high,
parameters tSALR, tHALR, tVL, and tSLR are not applicable.
6. Parameters tHAR and tSAR are not applicable if address latching is used.
7. When a set-up time is specified between an input and a clock, the set-up time
is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4 Volt
point of the clock.
8. When a hold time is specified between an input and a clock, the hold time is
the time in nanoseconds from the 1.4 Volt point of the clock to the 1.4 Volt
point of the input.
9. Output tristate delay is the time in nanoseconds from the 1.4 Volt point of the
reference signal to the ±300mV of the termination voltage on the output. The
test load is 50Ω to 1.4V in parallel with 10pF to GND.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
317
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Table 8
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- Microprocessor Interface Write Access (Figure 29, Figure 30)
Symbol
Parameter
Min
Typ
Max
Units
tSAW
Address to Valid Write Set-up
Time
25
ns
tSDW
Data to Valid Write Set-up Time
20
ns
tSALW
Address to Latch Set-up Time
20
ns
tHALW
Address to Latch Hold Time
20
ns
tVL
Valid Latch Pulse Width
20
ns
tSLW
Latch to Write Set-up
0
ns
tHLW
Latch to Write Hold
20
ns
tHDW
Data to Valid Write Hold Time
20
ns
tHAW
Address to Valid Write Hold Time
25
ns
tVWR
Valid Write Pulse Width
40
ns
tSRWB
RWB to Write Set-up Time
25
ns
tHRWB
RWB to Write Hold Time
10
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
ns
318
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Figure 29
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- Microprocessor Interface Write Timing (Intel Mode)
A[7:0]
Valid Address
tS ALW
tV L
tH ALW
tS LW
tHLW
ALE
tSAW
tH AW
tVWR
(CSB+WRB)
tS DW
D[7:0]
tH DW
Valid Data
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
319
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Figure 30
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- Microprocessor Interface Write Timing (Motorola Mode)
tS AW
A[7:0]
Valid Address
tS RWB
tH RWB
RWB
tSALW
tVL
tH ALW
tSLW
tHLW
ALE
tHAW
tVWR
(!CSB & E)
tS DW
D[7:0]
tH DW
Valid Data
Notes on Microprocessor Interface Write Timing:
1. a. In Intel mode, a valid write strobe bar is defined as a logical OR of the CSB
and the WRB signals.
b. In Motorola mode, a valid write strobe is defined as a logical AND of the E
signal, the inverted RWB signal, and the inverted CSB signal.
2. Microprocessor Interface timing applies to normal mode register accesses
only.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
320
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
3. In non-multiplexed address/data bus architectures, ALE should be held high,
parameters tSALW, tHALW, tVL, and tSLW are not applicable.
4. Parameters tHAW and tSAW are not applicable if address latching is used.
5. Output propagation delay time is the time in nanoseconds from the 1.4 Volt
point of the reference signal to the 1.4 Volt point of the output.
6. When a set-up time is specified between an input and a clock, the set-up time
is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4 Volt
point of the clock.
7. When a hold time is specified between an input and a clock, the hold time is
the time in nanoseconds from the 1.4 Volt point of the clock to the 1.4 Volt
point of the input.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
321
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
17
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
TUPP-PLUS TIMING CHARACTERISTICS
(TA = -40°C to +85°C, VDD = 5 V ±10%)
Table 9
Symbol
- TUPP-PLUS Input (Figure 31)
Description
Min
SCLK Frequency (nominally 19.44
MHz )
SCLK Duty Cycle
40
NSCLK Frequency (nominally
38.88 MHz)
Max
Units
20
MHz
60
%
40
MHz
60
%
NSCLK Duty Cycle
40
tSID
ID[7:0] Set-up Time
5
ns
tHID
ID[7:0] Hold Time
3
ns
tSIDP
IDP Set-up Time
5
ns
tHIDP
IDP Hold Time
3
ns
tSPL
IPL and OPL Set-Up Time
5
ns
tHPL
IPL and OPL Hold Time
3
ns
tSC1J1
IC1J1 and OC1J1 Set-Up Time
5
ns
tHC1J1
IC1J1 and OC1J1 Hold Time
3
ns
tSTMF
ITMF and OTMF Set-Up Time
5
ns
tHTMF
ITMF and OTMF Hold Time
3
ns
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
322
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Figure 31
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- Input Timing
SCLK/
NSCLK
tS ID
tH ID
tS IDP
tH IDP
tS PL
tH PL
tS C1J1
tH C1J1
tS TMF
tH TMF
ID[7:0]
IDP
IPL/
OPL
IC1J1/
OC1J1
ITMF/
OTMF
Notes on Input Timing:
1. When a set-up time is specified between an input and a clock, the set-up time
is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4 Volt
point of the clock.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
323
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
2. When a hold time is specified between an input and a clock, the hold time is
the time in nanoseconds from the 1.4 Volt point of the clock to the 1.4 Volt
point of the input.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
324
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Table 10
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- TUPP-PLUS Stream Output (Figure 32)
Symbol
Description
Min
Max
Units
tPOD
SCLK High to OD[7:0] Valid
4
25
ns
tPODP
SCLK High to ODP Valid
4
25
ns
tPTPL
SCLK High to OTPL Valid
4
25
ns
tPTV5
SCLK High to OTV5 Valid
4
25
ns
tPTPOH
SCLK High to TPOH Valid
4
25
ns
tPAIS
SCLK High to AIS Valid
4
25
ns
tPIDLE
SCLK High to IDLE Valid
4
25
ns
tPLC1
SCLK High to LC1J1V1 Valid
4
25
ns
tPLPL
SCLK High to LPL Valid
4
25
ns
tPLOM
SCLK High to LOM Valid
4
25
ns
tPOD
NSCLK High to OD[3:0] Valid
3
20
ns
tPODP
NSCLK High to ODP Valid
3
20
ns
tPTPL
NSCLK High to OTPL Valid
3
20
ns
tPTV5
NSCLK High to OTV5 Valid
3
20
ns
tPTPOH
NSCLK High to TPOH Valid
3
20
ns
tPAIS
NSCLK High to AIS Valid
3
20
ns
tPIDLE
NSCLK High to IDLE Valid
3
20
ns
tPLC1
NSCLK High to LC1J1V1 Valid
3
20
ns
tPLPL
NSCLK High to LPL Valid
3
20
ns
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
325
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Figure 32
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- Stream Output Timing
SCLK/
NSCLK
tP OD
OD[7:0]
tP ODP
ODP
tP TPL
OTPL
tP TV5
OTV5
tP TPOH
TPOH
tP AIS
AIS
tP IDLE
IDLE
tP LC1
LC1J1V1
tP LPL
LPL
tP LOM
LOM
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
326
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Table 11
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- TUPP-PLUS Path Overhead Output (Figure 33)
Symbol
Description
Min
Max
Units
tPPOH
POHCK Low to POH[3:1] Valid
-5
25
ns
tPPOHFP
POHCK Low to POHFP[3:1] Valid
-5
25
ns
tPPOHEN
POHCK Low to POHEN[3:1] Valid
-5
25
ns
tPRAD
POHCK Low to RAD Valid
-5
25
ns
Figure 33
- Path Overhead Output Timing
POHCK
tP POH
POH[3:1]
tP POHFP
POHFP[3:1]
tP POHEN
POHEN[3:1]
tP RAD
RAD
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
327
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Table 12
Symbol
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- JTAG Port Interface (Figure 34)
Description
Min
TCK Frequency
Max
Units
1
MHz
60
%
TCK Duty Cycle
40
tSTMS
TMS Set-up time to TCK
50
ns
tHTMS
TMS Hold time to TCK
50
ns
tSTDI
TDI Set-up time to TCK
50
ns
tHTDI
TDI Hold time to TCK
50
ns
tPTDO
TCK Low to TDO Valid
2
50
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
ns
328
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
Figure 34
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
- JTAG Port Interface Timing
TCK
tS TMS
tH TMS
tS TDI
tH TDI
TMS
TDI
TCK
tP TDO
TDO
Notes on Output Timing:
1. Output propagation delay time is the time in nanoseconds from the 1.4 Volt
point of the reference signal to the 1.4 Volt point of the output.
2. Output propagation delays are measured with a 50 pF load on the outputs.
3. Output propagation delays of signal outputs that are specified in relation to a
reference output are measured with a 50 pF load on both the signal output
and the reference output.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
329
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
18
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
ORDERING AND THERMAL INFORMATION
Table 13
- TUPP-PLUS Ordering Information
PART NO.
DESCRIPTION
PM5362-RI
160 Metric Plastic Quad Flat Pack (MQFP)
Table 14
- TUPP-PLUS Thermal Information
PART NO.
CASE TEMPERATURE
Theta Ja
Theta Jc
PM5362-RI
-40°C to 85°C
35°C/W
9°C/W
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
330
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
19
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
MECHANICAL INFORMATION
Figure 35
- METRIC PLASTIC QUAD FLATPACK - MQFP (BODY
28x28x3.49MM) 160 PIN MQFP - (R SUFFIX)
D
A
160
D1
1
Pin 1
Designator
e
E
E1
8-12 DEG
8-12 DEG
A2
SEE DETAIL A
0-10 DEG.
NOTES: 1) ALL DIMENSIONS IN MILLIMETER.
STANDOFF
A
.25
2) DIMENSIONS SHOWN ARE NOMINAL
WITH TOLERANCES AS INDICATED.
A1
3) FOOT LENGTH "L" IS MEASURED AT
GAGE PLANE, 0.25 ABOVE SEATING PLANE.
SEATING
PLANE
C
C
0-7 DEG
b
L
0.13-0.23
LEAD COPLANARITY
ccc
C
DETAIL A
PACKAGE TYPE: 160 PIN METRIC PLASTIC QUAD FLATPACK-MQFP
BODY SIZE: 28 x 28 x 3.49 MM
Dim.
A
A1
A2
D
D1
E
E1
L
Min.
3.42
0.25
3.17
30.95
27.85
30.95
27.85
0.73
3.42
31.20
28.00
31.20
28.00
0.88
3.68
31.45
28.10
31.45
28.10
1.03
Nom.
Max.
4.07
0.39
e
b
ccc
0.22
0.65
0.38
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
0.10
331
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
NOTES
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
332
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
NOTES
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
333
PM5362 TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
CONTACTING PMC-SIERRA, INC.
PMC-Sierra, Inc.
105-8555 Baxter Place Burnaby, BC
Canada V5A 4V7
Tel:
(604) 415-6000
Fax:
(604) 415-6200
Document Information:
Corporate Information:
Application Information:
Web Site:
[email protected]
[email protected]
[email protected]
http://www.pmc-sierra.com
None of the information contained in this document constitutes an express or implied warranty by PMC-Sierra, Inc. as to the sufficiency, fitness or
suitability for a particular purpose of any such information or the fitness, or suitability for a particular purpose, merchantability, performance, compatibility
with other parts or systems, of any of the products of PMC-Sierra, Inc., or any portion thereof, referred to in this document. PMC-Sierra, Inc. expressly
disclaims all representations and warranties of any kind regarding the contents or use of the information, including, but not limited to, express and implied
warranties of accuracy, completeness, merchantability, fitness for a particular use, or non-infringement.
In no event will PMC-Sierra, Inc. be liable for any direct, indirect, special, incidental or consequential damages, including, but not limited to, lost profits,
lost business or lost data resulting from any use of or reliance upon the information, whether or not PMC-Sierra, Inc. has been advised of the possibility
of such damage.
© 1998 PMC-Sierra, Inc.