HAS SERIES - 30 WATT FEATURES • Industry Standard Half-Brick • Low-Cost Design • 100°C Baseplate Operation • Open-Frame Packaging • 24V and 48V Input Versions • Input Pi Filter • Optional Enable Logic • 1500V Isolation DESCRIPTION HAS DC/DC converters provide up to 30 watts of output power in an industry-standard package and footprint. With a maximum case temperature of 100°C, the HAS is well suited for the most demanding telecom, networking, and industrial applications. The HAS features 1500 VDC isolation, short circuit, and overtemperature protection, as well as six-sided shielding. The HAS series is available with optional enable and voltage trim pins. Please see the IAD series for dual output applications. Efficiency vs. Load (24V Input) 90 85 EFFICIENCY % TECHNICAL SPECIFICATIONS 80 Input Voltage Range 24 VDC Nominal 48 VDC Nominal Reflected Ripple HAS030YG-A 75 18 - 36 VDC 36 - 75 VDC 50 mA EFF. (18v) EFF. (24v) 70 EFF. (36v) 65 Output 10 ±1% 0.2% Vout 0.2% Vout 0.5 VDC 10 % 25% Iout 4% Vout 500 µs ±10% Hiccup 110 - 140% 115 - 140% Vout Nom. Vin Negative 10 mA Max. 20 30 40 50 60 70 80 90 100 90 100 LOAD % Efficiency vs. Load (48V Input) 95 90 85 EFFICIENCY % Setpoint Accuracy Line Regulation Vin Min. - Vin Max., Iout Rated Load Regulation Iout Min. - Iout Max., Vin Nom. Remote Sense Headroom Minimum Output Current Dynamic Regulation, Loadstep Pk Deviation Settling Time Voltage Trim Range Short Circuit / Overcurrent Protection Current Limit Threshold Range, % of Iout Rated OVP Trip Range Remote Shutdown Reference Shutdown Pin Current, Sourced At Off 60 80 75 70 HAS030ZH-A 65 HAS030ZG-A 60 HAS030ZJ-A 55 50 10 General Turn-On Time Remote Shutdown Switching Frequency Isolation Input - Output Input - Case Output - Case Temperature Coefficient Case Temperature Operating Range Storage Range Humidity Max., Non-Condensing Vibration, 3 Axes, 5 Min Each MTBF† (Bellcore TR-NWT-000332) Safety Weight (Approx.) REV. 09/01 20 30 40 50 60 70 80 LOAD % 10 mS Positive/Negative Logic 250 kHz Notes † MTBF predictions may vary slightly from model to model. 1500 VDC 1050 VDC 500 VDC 0.03%/°C Specifications typically at 25°C, normal line, and full load, unless otherwise stated. Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with commercial wave-soldering equipment. -40 To +100°C -40 To +125°C 95% 5 g, 10 - 55 Hz 2.5 X 106 hrs UL, cUL, TUV 1.4 oz Safety: Agency approvals may vary from model to model. Please consult factory for specific model information. Units are water-washable and fully compatible with commercial spray or immersion post wave-solder washing equipment. 1 HAS SERIES - 30 WATT MODELS - (See the last page of section for options.) MODEL INPUT VOLTAGE (VOLTS) INPUT VOLTAGE RANGE (VOLTS) MAXIMUM INPUT CURRENT (AMPS)* OUTPUT VOLTAGE (VOLTS) RATED OUTPUT CURRENT (AMPS) 24 24 24 48 48 48 48 18-36 18-36 18-36 36-75 36-75 36-75 36-75 2.2 2.2 2.2 1.0 1.3 1.3 1.3 5 12 15 3.3 5 12 15 6.0 2.5 2.0 6.0 6.0 2.5 2.0 HAS030YG-A HAS030YH-A HAS030YJ-A HAS030ZE-A HAS030ZG-A HAS030ZH-A HAS030ZJ-A RIPPLE & NOISE pk-pk (mV) TYPICAL EFFICIENCY** 100 150 150 100 100 150 150 83% 87% 86% 81% 83% 88% 88% NOTES: * Maximum input current at minimum input voltage, maximum rated output power. ** At nominal Vin, rated output. MECHANICAL DRAWING !" # $% Thermal Impedance Natural Convection 100 LFM 200 LFM 300 LFM 400 LFM 7.9 °C/W 6.8 °C/W 4.9 °C/W 3.6 °C/W 3.0 °C/W Note: Thermal impedance data is dependent on many environmental factors. The exact thermal performance should be validated for specific application. Pin Tolerances Function 1 -Vin 2 3 4 Case On/Off +Vin 5 -Vout 6 7 8 9 -Sense Trim +Sense +Vout 2 Inches: .XX ± 0.020 .XXX ± 0.010 Pin: ± 0.002 (Millimeters) .X ± 0.5 .XX ± 0.25 ± 0.05 (Dimensions as listed unless otherwise specified.) OPTIONS ! !-. ' ' ' ' ' . " ' 0 2 3 4 5 7007) 28 6 ! 70;7) 38 6 ! 724) 90 "= "> 8 < 0" 724) 90 @ "> 0@ 74;) 004 "= "> 74;) 004 @ "> 2" 7<;) 240 "= "> 7<;) 240 @ "> 3" 2@ 3@ "# "$% "$ " "! ! &$ & &! ' '&% "# "$% "$ " "! &$ & &! / /% /' 1# ! 1#% 1# ! * 1# ! * 1 + # : * # : * # : %16 "! "!% &! 16 * '!% '?% 6> # : %16 "! "!% &! 16 * '!% '?% 6> # : %16 "! "!% &! 16 * '!% '?% 6> # : %16 "! "!% &! 16 * '!% '?% 6> # : %16 "! "!% &! 16 * '!% '?% 6> # : %16 "! "!% &! 16 * '!% '?% 6> ''! (!) ' * + ''! (" ) ' * +,, 6 ! 7087) 49 1 ' 6 1 ' 6 1 ' 6 1 ' 6 1 ' 6 1 ' 6 +A "$7;7BC-#'3@ D "$7;7BC-# !- 7<;) > !70;5E-3 D !70;5E &$799BC-#'8 D &$799BC-# ! 7007) NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. 3