POWER-ONE FRD

(888) IPD-CONVerters ● (888) 473-2668
●
www.ipdconverters.com
FRD SERIES - DUAL OUTPUT, 5 WATT
DESCRIPTION
FEATURES
• 500V Isolation
• Short Circuit Protection
• 6-Sided Shielding
FRD dual output DC/DC converters offer excellent
• Wide Input Range
regulation and isolation in an industry standard
• Trim and Enable Pins
package. Available in several input versions, the FRD • Remote Sense Pins
is perfect for industrial, datacom, or telecom
applications. The FRD features short circuit
protection, six-sided shielding, and 500 VDC isolation.
Please see the FRS series for single output applications.
Efficiency vs. Load (28V Input)
80
75
EFFICIENCY %
70
65
60
55
EFF. FRD2812
50
EFF. FRD2815)
45
40
35
10
20
30
40
TECHNICAL SPECIFICATIONS
50
60
70
80
90
10
LOAD %
Input
Voltage Range
Reflected Ripple
Reverse Input Current
5V, 12V, 24V, 28V, and 48V Nominal
See selection chart for specific input range.
20% Iin Max.
100% Iin Max.
Efficiency vs. Load (48V Input)
70
65
EFFICIENCY %
60
Output
Setpoint Accuracy
Line Regulation Vin Min. - Vin Max., Iout Rated
Load Regulation Iout Min. - Iout Max., Vin Nom.
Minimum Output Current
Short Circuit Protection1
±1% Vout
±0.15% Vout
55
50
45
EFF. FRD4812
40
EFF. FRD4815
±0.15% Vout Iout Rated
10 % lout Rated
Continuous
35
30
25
10
20
30
40
50
60
70
80
90
10
LOAD %
General
Switching Frequency
Isolation
Input - Output
Isolation Resistance - Input to Output
Case Temperature
Operating Range
Storage Range
Humidity Max, Non-Condensing
Temperature Coefficient
Vibration, 3 Axes, 5 Min Each
Safety
Weight (Approx.)
20 kHz
500 VDC
109 Ohms
-25 To +85°C
-40 To +125°C
95%
±0.02%/°C
5 g, 10 - 55 Hz
Consult Factory
2.2 oz
C-64
Notes
†
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
FRD SERIES - DUAL OUTPUT, 5 WATT
MODELS - (See the last page of this file for options.)
Vin
(Volts)
Vin Range
(Volts)
Iin Max.*
(Amps)
Vout
(Volts)
Iout Rated
(Amps)
Ripple & Noise
Pk-Pk (mV)
Efficiency
Typ. **
Model
5
5
12
12
24
24
28
28
48
48
4.65 - 5.50
4.65 - 5.50
10.90 - 13.20
10.90 - 13.20
21.60 - 26.40
21.60 - 26.40
25.20 - 30.80
25.20 - 30.80
43.20 - 52.80
43.20 - 52.80
2.01
2.04
0.85
0.86
0.43
0.45
0.37
0.38
0.21
0.22
±12
±15
±12
±15
±12
±15
±12
±15
±12
±15
±0.23
±0.19
±0.23
±0.19
±0.23
±0.19
±0.23
±0.19
±0.23
±0.19
40
40
40
40
40
40
40
40
40
40
65%
66%
66%
67%
66%
65%
69%
71%
65%
66%
FRD512
FRD515
FRD1212
FRD1215
FRD2412
FRD2415
FRD2812
FRD2815
FRD4812
FRD4815
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
MECHANICAL DRAWING
2.00"
(50.8mm)
0.18"(4.6mm) MIN.
0.100"
-0.300"
(-7.6mm) (2.5mm)
0.500"
(12.7mm)
1.40"
(35.6mm)
0.800"
(20.3mm)
3
4
5
2.00"
(50.8mm)
BOTTOM VIEW
1
2
0
DIA 0.040"
(1.0mm)
0.40"
0
(10.2mm)
1.10"
(27.9mm)
0.200"
(5.1mm)
Pin
Thermal Impedance
Natural convection
100 LFM
200 LFM
300 LFM
400 LFM
10.3
7.7
6.3
5.1
4.1
°C/W
°C/W
°C/W
°C/W
°C/W
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated
for specific application.
Tolerances
Function
1
2
3
4
5
+Vin
-Vin
+ Vout
Common
- Vout
Inches:
.XX ± 0.040
.XXX ± 0.010
(Millimeters)
.X ± 1.0
.XX ± 0.25
Pin:
± 0.002
± 0.05
Case:
+ 0.04, - 0.00
+ 1.0, - 0.0
(Tolerances as listed unless otherwise specified.)
C-65
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that
you prefer and add them to the model number. Example ordering options are located below the
options table.
OPTION
SUFFIX
APPLICABLE SERIES
Negative Logic
N
HAS, HBD, HBS, HES, LES, QBS,
QES, TES, TQD
Lucent Compatible Trim
T
HAS, HBD, HBS, HES, QBS, QES
Terminal Strip
TS
REMARKS
TTL “Low” Turns Module ON
TTL “High” Turns Module OFF
XWS, XWD, XWT
Trim
1
IAS, LES
Enable
2
IAD, IAS, LES, SMS
Trim and Enable
3
IAS, LES
Current Share
4
SMS
Headerless
Y
Encapsulated EWS, IWS, OWS
PIN LENGTH AND HEATSINK
OPTIONS
Standard Pin Length is 0.180”
(4.6mm)
0.110” (2.8mm) Pin Length
8
All Units (Except SMS)
0.150” (3.8mm) Pin Length
9
All Units (Except SMS)
0.24” (6.1mm) Horizontal Heatsink
1H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.24” (6.1mm) Vertical Heatsink
1V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.45” (11.4mm) Horizontal
Heatsink
2H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.45” (11.4mm) Vertical Heatsink
2V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.95” (24.1mm) Horizontal
Heatsink
3H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.95” (24.1mm) Vertical Heatsink
3V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
Example Options:HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and
0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
C105