SEME-LAB LM137HVH

IP137MAHVH
IP137MHVHA
LM137HVH
IP137MAH
IP137MH
LM137H
0.5 AMP
NEGATIVE ADJUSTABLE
VOLTAGE REGULATOR
2
1
3
FEATURES
• –1.2V TO 47V OUTPUT VOLTAGE RANGE
Pin 1 – ADJ.
Pin 2 – VOUT
Pin 3 – VIN
H Package – TO–39
• 0.5A OUTPUT CURRENT
• 1% OUTPUT VOLTAGE TOLERANCE
• 0.5% / A LOAD REGULATION
• 0.01% / V LINE REGULATION
• 0.02% / W THERMAL REGULATION
• INTERNAL PROTECTION
Internal current and power limiting coupled with
true thermal limiting prevents device damage
due to overloads or shorts, even if the regulator
is not fastened to a heat sink.
ABSOLUTE MAXIMUM RATINGS (Tcase = 25°C unless otherwise stated)
VI–O
Input - Output Differential Voltage
– Standard
40V
– HV Series
50V
IO
Output Current
Internally limited
PD
Power Dissipation
Internally limited
TJ
Operating Junction Temperature Range
–55 to +150°C
TSTG
Storage Temperature
–65 to 150°C
TJ
Lead temperature
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: [email protected]
Website: http://www.semelab.co.uk
300°C
Prelim. 7/00
IP137MAHVH
IP137MHVHA
LM137HVH
Parameter
IP137MAHV
IP137MA
Min.
Typ.
Max.
Test Conditions
IOUT = 10mA
VREF
Reference Voltage
Thermal Regulation
Ripple Rejection
IADJ
DIADJ
Adjust Pin Current
Adjust Pin Current
Change
-1.25
-1.262 -1.225
-1.25
-1.275
V
-1.220
-1.25
-1.280 -1.200
-1.25
-1.300
V
0.005
0.010
0.010
0.020
0.010
0.030
0.020
0.050
VOUT £ 5V
5
25
15
25
mV
VOUT ³ 5V
0.1
0.5
0.3
0.5
%
TJ = -55 to 150°C
VIN – VOUT = 3V to VMAX
TJ = -55 to 150°C
Minimum Load
Current
ICL
Current Limit
VOUT £ 5V
10
50
20
50
mV
TJ = -55 to 150°C
VOUT ³ 5V
0.2
1
0.3
1
%
tp = 10ms
TA = 25°C
0.002
0.020
0.002
0.02
%/W
VOUT = -10V
f = 120Hz
CADJ = 0
CADJ = 10mF
TJ = -55 to 150°C
60
66
70
80
TJ = -55 to 150°C
TJ = -55 to +150°C
TJ = -55 to 150°C
TJ = -55 to 150°C
DVOUT Temperature
TJ = -55 to 150°C
DTEMP Stability
TA = +125°C
DVOUT
Long Term Stability
DTIME
t = 1000 Hrs
RqJC
RMS Output Noise
f = 10 Hz to 10 kHz
(% of VOUT)
TA = 25°C
Thermal Resistance
Junction to Case
H Package
66
60
dB
77
dB
65
100
65
100
IOUT = 10mA to IMAX
0.2
2
0.5
5
VIN – VOUT = 3V to 40V
1.0
5
2
5
2.0
6
3
6
VIN – VOUT £ 40V
2.5
5
2.5
5
VIN – VOUT £ 10V
1.2
3
1.2
3
1.5
0.50
0.80
1.5
0.15
0.17
0.10
0.17
VIN – VOUT = 3V to 50V
VIN – VOUT £ 15V
0.50
0.80
VIN – VOUT = 40V
0.15
0.17
0.10
0.17
0.5
0.6
1.5
0.6
0.3
1
0.3
VIN – VOUT = 50V
(HV SERIES)
en
%/V
IOUT = 10mA to IMAX
(HV SERIES)
IMIN
Units
-1.238
VIN – VOUT = 3V to VMAX
IOUT = 10mA to IMAX
DVOUT
Load Regulation 1
DIOUT
IP137MHV , IP137M
LM137HV , LM137
Min.
Typ.
Max.
IOUT = 10mA to IMAX
P £ PMAX
DVOUT
Line Regulation 1
DVIN
IP137MAH
IP137MH
LM137H
12
15
12
mA
mA
A
0.5
%
1
%
%
0.003
0.003
mA
15
°C/W
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to
heating effects are covered under thermal regulation specifications. Load regulation is measured at a point 1/8” from the bottom of
the package for the TO–3 and TO–66 packages, at the junction of the wide and narrow portion of the output lead for the
SMD1package, and 1/8” below the base of the package on the output pin of the TO–257 package.
2) Test Conditions unless otherwise stated: VIN – VOUT = 5V , IOUT = 0.1A , PMAX = 2W , IMAX = 0.5A
VMAX = 40V for standard series , 50V for HV series.
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: [email protected]
Website: http://www.semelab.co.uk
Prelim. 7/00