SEME-LAB LM337

IP137A SERIES
IP137A SERIES
IP337A SERIES
IP337A SERIES
1
1
2
2
3
3
Pin 1 – ADJ.
Pin 2 – VOUT
Case – VIN
Pin 1 – ADJ.
Pin 2 – VOUT
Case – VIN
K Package – TO–3
R Package – TO–66
LM137A SERIES
LM137A SERIES
1.5 AMP
NEGATIVE ADJUSTABLE
VOLTAGE REGULATOR
FEATURES
• OUTPUT VOLTAGE RANGE OF:
1.25 TO 40V FOR STANDARD VERSION
1.25 TO 50V FOR –HV VERSION
• 1% OUTPUT VOLTAGE TOLERANCE
1
2
1 2 3
3
• 0.3% LOAD REGULATION
• 0.01% / V LINE REGULATION
Pin 1 – ADJ.
Pin 2 – VIN
Pin 3 – VOUT
Case – VIN
Pin 1 – ADJ.
Pin 2 – VIN
Pin 3 – VOUT
Case – VIN
T Package – TO–220
G Package – TO–257
• COMPLETE SERIES OF PROTECTIONS:
• CURRENT LIMITING
• THERMAL SHUTDOWN
• SOA CONTROL
!
1 2 3
Pin 1 – ADJ.
Pin 2 – VIN
Pin 3 – VOUT
Pin 1 – ADJ.
Pin 2 – VIN
Pin 3 – VOUT
SG Package – SMD1
CERAMIC SURFACE
MOUNT
IG Package – TO–257
(Isolated)
ABSOLUTE MAXIMUM RATINGS (Tcase = 25°C unless otherwise stated)
VI–O
Input - Output Differential Voltage
– Standard
40V
– HV Series
50V
IO
Output Current
Internally limited
PD
Power Dissipation
Internally limited
Tj
Operating Junction Temperature Range
Tstg
Storage Temperature
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: [email protected]
Website: http://www.semelab.co.uk
See Order Information Table
-65 to 150°C
Prelim. 7/00
LM137A SERIES
LM137A SERIES
IP137A SERIES
IP137A SERIES
IP337A SERIES
IP337A SERIES
Parameter
IP137A , IP137AHV
LM137A , LM137AHV
Min.
Typ.
Max.
Test Conditions
IOUT = 10mA
VREF
Reference Voltage
Thermal Regulation
Ripple Rejection
IADJ
DIADJ
Adjust Pin Current
-1.238
-1.25
-1.262
-1.225
-1.25
-1.275
V
-1.220
-1.25
-1.280
-1.200
-1.250
-1.300
V
0.005
0.010
0.010
0.020
0.010
0.030
0.020
0.050
VOUT £ 5V
5
25
15
25
mV
VOUT ³ 5V
0.1
0.5
0.3
0.5
%
VIN – VOUT = 3V to VMAX
TJ = -55 to 150°C
VIN – VOUT = 3V to VMAX
TJ = -55 to 150°C
IOUT = 10mA to IMAX
DVOUT
Load Regulation 1
DIOUT
VOUT £ 5V
10
50
20
50
mV
TJ = -55 to 150°C
VOUT ³ 5V
0.2
1
0.3
1
%
tp = 10ms
TA = 25°C
0.002
0.020
0.002
0.02
%/W
CADJ = 0
VOUT = -10V
CADJ = 10mF
f = 120Hz
TJ = -55 to 150°C
60
66
70
80
TJ = -55 to 150°C
ICL
IOUT = 10mA to IMAX
0.2
2
0.5
5
1.0
5
2
5
2.0
6
3
6
VIN – VOUT £ 40V
2.5
5
2.5
5
VIN – VOUT £ 10V
1.2
3
1.2
3
3.2
VIN – VOUT = 3V to 40V
to 150°C
VIN – VOUT = 3V to 50V
TJ = -55 to 150°C
TJ = -55 to 150°C
DVOUT Temperature
TJ = -55 to 150°C
DTEMP Stability
TA = +125°C
DVOUT
Long Term Stability
DTIME
t = 1000 Hrs
RqJC
RMS Output Noise
f = 10 Hz to 10 kHz
(% of VOUT)
TA = 25°C
Thermal Resistance
Junction to Case
dB
100
VIN – VOUT £ 15V
1.5
2.2
3.2
1.5
2.2
VIN – VOUT = 40V
0.24
0.4
1
0.24
0.4
0.2
0.4
0.8
0.2
0.4
0.6
1.5
0.6
0.3
1
0.3
VIN – VOUT = 50V
(HV SERIES)
en
77
65
TJ = -55
Current Limit
dB
100
Change
Current
66
60
65
Adjust Pin Current
Minimum Load
%/V
IOUT = 10mA to IMAX
(HV SERIES)
IMIN
Units
IOUT = 10mA to IMAX
P £ PMAX
DVOUT
Line Regulation 1
DIOUT
IP137 , IP137HV
LM137 , LM137HV
Min.
Typ.
Max.
mA
mA
A
0.8
%
1
%
%
0.003
0.003
mA
K Package
2.3
3
2.3
3
R Package
5
7
5
7
G Package
3
5
3
5
°C/W
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to
heating effects are covered under thermal regulation specifications. Load regulation is measured at a point 1/8” from the bottom of
the package for the TO–3 and TO–66 packages, at the junction of the wide and narrow portion of the output lead for the SMD1
package, and 1/8” below the base of the package on the output pin of the TO–257 package.
2) Test Conditions unless otherwise stated: VIN – VOUT = 5V , IOUT = 0.5A , PMAX = 20W , IMAX = 1.5A
VMAX = 40V for standard series , 50V for HV series.
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: [email protected]
Website: http://www.semelab.co.uk
Prelim. 7/00
LM137A SERIES
LM137A SERIES
IP137A SERIES
IP137A SERIES
IP337A SERIES
IP337A SERIES
Parameter
IP337AHV
Min.
Typ.
Max.
Test Conditions
IOUT = 10mA
VREF
Reference Voltage
Thermal Regulation
Ripple Rejection
IADJ
DIADJ
Adjust Pin Current
-1.238
-1.25
-1.262
-1.213
-1.25
-1.287
V
-1.220
-1.25
-1.280
-1.200
-1.250
-1.300
V
0.005
0.010
0.010
0.040
0.010
0.030
0.020
0.070
VOUT £ 5V
5
25
15
50
mV
VOUT ³ 5V
0.1
0.5
0.3
1
%
VIN – VOUT = 3V to VMAX
TJ = 0 to 125°C
VIN – VOUT = 3V to VMAX
TJ = 0 to 125°C
IOUT = 10mA to IMAX
DVOUT
Load Regulation 1
DIOUT
VOUT £ 5V
10
50
20
70
mV
TJ = 0 to 125°C
VOUT ³ 5V
0.2
1
0.3
1.5
%
tp = 10ms
TA = 25°C
0.002
0.020
0.003
0.04
%/W
CADJ = 0
VOUT = 10V
CADJ = 10mF
f = 120Hz
TJ = 0 to 125°C
60
66
70
80
TJ = 0 to 125°C
ICL
IOUT = 10mA to IMAX
0.2
2
0.5
5
1.0
5
2
5
2.0
6
3
6
VIN – VOUT £ 40V
2.5
5
2.5
10
VIN – VOUT £ 10V
1.2
3
1
6
3.5
VIN – VOUT = 3V to 40V
to 125°C
VIN – VOUT = 3V to 50V
TJ = 0 to 125°C
TJ = 0 to 125°C
DVOUT Temperature
TJ = 0 to 125°C
DTEMP Stability
DVOUT
Long Term Stability t = 1000 Hrs
DTIME
RqJC
RMS Output Noise
f = 10 Hz to 10 kHz
(% of VOUT)
TA = 25°C
Thermal Resistance K Package
Junction to Case
T Package
dB
100
VIN – VOUT £ 15V
1.5
2.2
3.5
1.5
2.2
VIN – VOUT = 40V
0.24
0.4
1
0.15
0.4
0.2
0.4
0.8
0.1
0.4
0.6
1.5
0.6
0.3
1
0.3
VIN – VOUT = 50V
(HV SERIES)
en
77
65
TJ = 0
Current Limit
dB
100
Change
Current
66
60
65
Adjust Pin Current
Minimum Load
%/V
IOUT = 10mA to IMAX
(HV SERIES)
IMIN
Units
IOUT = 10mA to IMAX
P £ PMAX
DVOUT
Line Regulation 1
DIOUT
IP337HV
LM337HV
Min.
Typ.
Max.
2.3
3
2.3
4
5
4
mA
mA
A
0.8
%
1
%
%
0.003
0.003
mA
3
°C/W
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to
heating effects are covered under thermal regulation specifications. Load regulation is measured at a point 1/8” from the bottom of
the package for the TO–3 and TO–66 packages, at the junction of the wide and narrow portion of the output lead for the SMD1
package, and 1/8” below the base of the package on the output pin of the TO–257 package.
2) Test Conditions unless otherwise stated: VIN – VOUT = 5V , IOUT = 0.5A , PMAX = 20W , IMAX = 1.5A
VMAX = 40V for standard series , 50V for HV series.
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: [email protected]
Website: http://www.semelab.co.uk
Prelim. 7/00
LM137A SERIES
LM137A SERIES
IP137A SERIES
IP137A SERIES
IP337A SERIES
IP337A SERIES
APPLICATIONS INFORMATION
High Stability Regulator
Multiple Tracking Regulators
The output stability, load regulation, line regulation, thermal
regulation, temperature drift, long term drift, and noise, can be
improved by a factor of 6.6 over the standard regulator
configuration. This assumes a zener has 20PPM/°C maximum
drift and about 10 times lower noise than the regulator.
In the application shown below, regulator #2 to “N” will track
regulator #1 to within ±24mV initially, and to ±60mV over all load,
line, and temperature conditions.
If any regulator output is shorted to ground, all other
outputs will drop to -2V. Load regulation of regulators 2 to “N” will
be improved by VOUT / 1.25V compared to a standard regulator,
so regulator #1 should be the one which has the lowest load
current.
R 2*
7V
C3
1 0µF
2 µF
R3
1 .5 k
1%
1 µF
R1
1k
1%
C1
1µF
AD J
VIN
1 N4 0 0 2
AD J
VOU T
VIN
–VIN
* R2 =
IP337A
( VO U T )
– 908 Ω
9.08 x 10 -3
–VIN
–VO U T
R1
1 20 Ω
SO LID
TAN TALU M
VOU T
–VO U T1
R EG #1
IP137A
IP3 17A
2 µF
VOU T
VIN
+VIN
+VO U T
1µF
SO LID
TANTA LU M
1 N4 0 0 2
AD J
VIN
R2
SO LID
TANT ALUM
VOU T
–VO U T2
R EG #2
ADJ
IP137A
R1* *
1 00 Ω
1%
1 0µ F
1 0µ F
R2
5k
1%
2. 2
µF
D1
1N40 02
2 µF
R3
5k
VIN
R4
5k
1%
1µF
SO LID
TANTA LU M
1 N4 0 0 2
AD J
VOU T
–VO UT N
R EG #N
I P 13 7 A
R5* *
1 00 Ω
1%
2. 2
µF
D2
1N40 02
ADJ
VIN
C1
1 µF
VOU T
–VIN
–VO U T
SO LID
TANA TALU M
AD J
IP3 37A
VIN
(–)
VOU T
RS
IP337A
* Solid Tantalum
** R1 or R5 may be trimmed slightly to improve tracking.
I
(+)
I = 65µA + 1.25 V
RS
0.8 Ω ≤ R S ≤ 250Ω
Dual Tracking Supply
Current Regulator
Order Information
Part
Number
LM137
LM137HV
LM137A
LM137AHV
IP137
IP137HV
IP137A
IP137AHV
LM337
LM337HV
IP337
IP337HV
IP337A
IP337AHV
Semelab plc.
K–Pack
(TO–3)
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
R–Pack
(TO–66)
✔
✔
✔
✔
✔
✔
✔
✔
IG–Pack
G–Pack
T–Pack
(TO–257) (TO–220)
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
SG–Pack
Temp.
SMD1
Range
✔
-55 to +150°C
✔
”
✔
”
✔
”
✔
-55 to +150°C
✔
”
✔
”
✔
”
0 to 125°C
0 to 125°C
0 to 125°C
”
0 to 125°C
”
Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: [email protected]