SHARP GP2U06

GP2U06
High Sensitivity Dust Sensor
Compact and Thin Type Dust Sensor for Detecting Particles
(Unit : mm)
Outline Dimensions
General Description
Detecting window
Sharp's GP2U06 is dust sensor which integrated optical
sensor portion and signal amplifier portion.
It is suitable for indoor air purifier sensor because of
compact, thin, low dissipation current type.
38
φ3.2
1
2
φ9
3
4
58
Connector
Features
25
(1) Compact, thin type (58 x 38 x 25mm)
(2) High sensitivity
(Dust detecting sensitivity : TYP.0.5V/(0.1mg/m3)
(3) Can detect dust even in low density area
(Minimum particle density : TYP. 0.02mg/m3)
(4) Operating voltage : 5V
(5) Low dissipation current (Icc : MAX. 15mA)
Terminal configuration
1
GND
2
Output terminal
3
Emitting device operating terminal
4
Vcc
Applications
(1) Air purifiers
(2) Air conditioners
Absolute Maximum Ratings
Parameter
Symbol
(Ta=25˚C)
Unit
Ratings
Remarks
Supply voltage
Vcc
-0.3 to +7
V
-
Input terminal voltage
VLED
V
Operating temperature
Topr
-0.3 to +Vcc
-10 to +65
˚C
Open drain input
-
Storage temperature
Tstg
-20 to +80
˚C
-
Operating supply voltage
(Notice)
Symbol
Ratings
Unit
Remarks
Vcc
5±0.5
V
-
• In the absence of device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP device
shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
• Specifications are subject to change without notice for improvement.
(Internet) • Data for SHARP's optoelectronic/power device is provided on internet. (Address http://www.sharp.co.jp/ecg/)
Tec.U970502
GP2U06
High Sensitivity Dust Sensor
Electro-optical Characteristics
Parameter
Detecting sensitivity
Output voltage (no dust)
Range of output voltage
LED operating current
Dissipation current
Symbol
K
VOC
VOH
ILED
ICC
Conditions
*1, 2
*2
RL=4.7kΩ
LED terminal=0V *2
RL=
*2
MIN.
(Ta=25˚C, Vcc=5V)
TYP. MAX.
Unit
0.35
0
3.2
0.5
0.5
0.65
1.0
-
-
-
15
10
20
15
Input condition to LED terminal
V/(0.1mg/m3)
V
V
mA
mA
T=30ms
Vcc
Pw=0.4ms
R1
R3
R4
+
Tr
2
C1
LED
R2
*1 • Dust density is measured by mildseven smoke density, using digital dust meter [P-5L2 made by
SHIBATA scientific instrumental industry].
• Detecting sensitivity is settled according to the change of output voltage when dust density change
0.1mg/m3 from the initial value.
*2 Input conditions to LED terminal (pulse operation condition) is shown in the right figure.
GP2U06
Recommended input conditions to LED terminal
T=30±5ms
PW=0.4±0.1ms
Block Diagram
4 Vcc
Detecting window
Dust
Emitting
circuit
Operation
circuit
Photodiode
circuit
Amp.
3
Peak hold
circuit
Amp.
Emitting device
Operating terminal
2 Output terminal(Vo)
Sensitivity adjustment
1 GND
As of May 1997
Tec.U970502