SHARP PQ1PD1

Primary Regulators
PQ1PD1
PQ1PD1
(Under Development)
Primary Regulator for Switching Power Supply (100W Class)
■ Features
■ Outline Dimensions
¡5 - terminal lead forming package (equivalent to TO-3P)
¡Built-in oscillation circuit (oscillation frequency : 100kHz)
¡Output for power supply : 100W class
¡Built-in overheat protection, overcurrent protection function
(Unit : mm)
MAX 17
4.5±0.2
φ3.2
■ Applications
8.0±0.2
23.5±0.7
2.0±0.2
PQ1PD1
5.0
(33.0)
¡Switching power supplies for word processors
¡Switching power supplies for personal computers
¡Switching power supplies for TVs
4-(2.54)
1
● 2
● 3
● 4
● 5
●
MIN 5
(0.6)
(0.5)
3.2±0.5
8.2±0.7
( ) : Typical dimensions
1 Drain (VDS)
2 GND
3 Control (CA)
4 Feed back (FB)
5 Supply voltage (VCC)
■ Absolute Maximum Ratings
*1
*2
*3
*4
*1
*2
*3
*4
Parameter
Drain-GND(source)voltage
Drain current
Power supply voltage
FB terminal input voltage
CA terminal input current
Power dissipation
Junction temperature
Operating temperature
Storage temperature
Soldering temperature
(Ta=25˚C)
Symbol
VDS
ID
VCC
VFB
ICA
PD
Tj
Topr
Tstg
Tsol
Rating
500
8
35
4
2
45
150
-20 to +80
-40 to +150
260 (For 10s)
Unit
V
A
V
V
mA
W
˚C
˚C
˚C
˚C
Voltage between VCC terminal and GND terminal.
Voltage between FB-terminal and GND terminal.
With infinite heat sink, Refer to Fig. 2
Overheat protection may operate at 125=<Tj=<150˚C
· Please refer to the chapter “ Handling Precautions ”.
“ In the absence of confirmation by device specification sheets,SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices
shown in catalogs,data books,etc.Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device. ”
Primary Regulators
PQ1PD1
■ Electrical Characteristics
(Unless otherwise specified, conditions shall be VDS=10V,VCC=18V,VCA=OPEN,VFB=2.2V,RL=56Ω, Ta=25˚C)
Parameter
Drain-source onstate resistance
Drain-source leakage current
Oscillation frequency
Temperature change in oscillation frequency
Declining oscillation frequency
Maximum duty
Symbol
RDS (ON)
IDSS
fo
∆fo
foL
DMAX
VFBL
VFB FC
VFBH
VFB OCP
IFB
VCAL
VCAH
VCA(ON/OFF)
VCA FC
VCA(OVP)
ICAIN
ID(OVP)
VCC(ON)
VCC(OFF)
ICC(ST)
ICC(OFF)
ICC(OP)
ICA(CHG)
FB threshold voltage
FB current
CA threshold voltage
CA sink current
Overcurrent detecting level
Operation starting voltage
Operation stopping voltage
Stand-by current
Output OFF-mode consumption current
Output-operating mode consumption current
Charging current
Conditions
ID=2A
VDS=500V,VCC=7V
Tj=0 to 125˚C
VCA=5V
Duty=0%
Duty=DMAX
VCA=6V
VFB=GND
Duty=0%
Duty=DMAX
VFB=1V,VCA=6V
VDS=OPEN,VFB=OPEN
VDS=OPEN,VFB=OPEN
VDS=OPEN,VCC=14V,
VDS=OPEN,VCA=GND
VCA=GND,VFB=OPEN
A
+
A
VCC
5
●
1
●
PQ1PD1
4
●
3
●
2
●
RL
A
VFB
A
VCA
VDS
■ Block Diagram
agram
CA
3
VDS
1
VCC
5
Power dissipation PD (W)
50
0.01µF
40
30
20
10
←
Low voltage
malfunction
prevention circuit
Cut-off voltage
detecting circuit
0
-20
MAX.
1.0
250
110
43
50
3.1
-440
0.74
8.2
52
18.5
10.1
150
1.8
24
-5
Unit
Ω
µA
kHz
%
kHz
%
V
V
V
V
µA
V
V
V
V
V
µA
A
V
V
µA
mA
mA
µA
,,,
,,,
,,,
0
20
40
60
80
Ambient temperature Ta (˚C)
Note) Oblique line portion : Overheat
protection may operate in this area.
Constant
voltage
source
OFF voltage
detecting circuit
Frequency
conversion
circuit
Overheat
detection
circuit
FB 4
TYP.
0.75
100
±5
33
45
0.9
1.1
1.8
2.8
-620
0.9
1.8
0.6
4.3
7.7
36
4.8
17.0
9.3
100
0.6
12
-10
Fig. 2 Power Dissipation vs. Ambient
Temperature
Fig. 1 Test Circuit
CIN
100µF
MIN.
90
23
42
2.6
-800
0.49
7.2
20
15.5
8.5
-15
OSC
RQ
S
PWM
Overload
cut-off voltage
detecting circuit
+
-
DET
Drive
circuit
Overcurrent
detecting
circuit
2