SHINDENGEN Trankiller Axial Package OUTLINE DIMENSIONS ST02D-200 Case : AX078 (Unit : mm) RATINGS ●Absolute Maximum Ratings (Tl=25℃) Item Symbol Conditions Tstg Storage Temperature Tj Junction Temperature PRSM 10/1000μs, Non-repetitive Peak Surge Reverse Power IRSM 10/1000μs, Non-repetitive Peak Surge Reverse Current VRM Maximum Reverse Voltage ●Electrical Characteristics (Tl=25℃) Item Symbol Conditions Movement Start Voltage VBR IR = 1mA Restriction Voltage VCL IR trr θjL IPP = 0.75A Leak Current Reverse Recovery Time Thermal Resistance VR = VRM IF/IR=0.1A/0.3A Junction to lead Copyright & Copy;2000 Shindengen Electric Mfg.Co.Ltd ZD -40~150 150 200 0.7 170 Di -40~150 150 600 Unit ℃ ℃ W A V ZD MIN 185 STD 200 MAX 215 MAX 300 MAX 5 MAX 17 Di Unit - V MAX 5 MAX 500 MAX 17 V μA ns ℃/W ST02D-200 Breakdown Voltage 225 TYP IR = 1mA TEST 220 Breakdown Voltage VBR [V] 215 210 205 200 195 190 0 50 100 Junction Temperature Tj [°C] 150 ST02D-200 Reverse Current 10 TYP VR = 170V TEST Reverse Current IR [µA] 1 0.1 0.01 0 50 100 Junction Temperature Tj [°C] 150 ST02D-200 Reverse Current 10 TYP VR = 600V TEST Reverse Current IR [µA] 1 0.1 0.01 0 50 100 Junction Temperature Tj [°C] 150 ST02D-200 Peak Surge Reverse Power 100 IP V CL 0 Peak Surge Reverse Power PRSM [kW] tP PRSM = IP × VCL Tl = 25°C 10 1 0.1 0.01 0.1 1 10 100 Pulse Width t P [µs] 1000 10 4 ST02D-200 Junction Capacitance 100 TYP Junction Capacitance Cj [pF] TEST VD = 0V VD = 40V 10 1 1 10 100 Frequency f [kHz] 1000 ST02D-200 Junction Capacitance 100 TYP TEST Junction Capacitance Cj [pF] VD = 0V 10 VD = 50V 1 1 10 100 Frequency f [kHz] 1000 ST02D-200 Junction Capacitance 100 TYP f = 100kHz Junction Capacitance Cj [pF] TEST 10 1 1 10 Applied Voltage VD [V] ST02D-200 Junction Capacitance 100 TYP f = 100kHz Junction Capacitance Cj [pF] TEST 10 1 1 10 Applied Voltage VD [V]