ZARLINK MT9043AN48PINSSOP

MT9043
T1/E1 System Synchronizer
Data Sheet
Features
November 2003
•
Supports AT&T TR62411 and Bellcore GR-1244CORE, Stratum 4 Enhanced and Stratum 4 timing
for DS1 interfaces
•
Supports ETSI ETS 300 011, TBR 4, TBR 12 and
TBR 13 timing for E1 interfaces
•
Selectable 19.44 MHz, 1.544MHz, 2.048MHz or
8kHz input reference signals
•
Provides C1.5, C2, C4, C6, C8, C16, and C19
(STS-3/OC3 clock divided by 8) output clock
signals
MT9043AN 48 pin SSOP
-40°C to +85°C
Description
The MT9043 T1/E1 System Synchronizer contains a
digital phase-locked loop (DPLL), which provides timing
and synchronization signals for multitrunk T1 and E1
primary rate transmission links.
•
Provides 5 different styles of 8 KHz framing
pulses
•
•
•
•
Attenuates wander from 1.9Hz
Fast lock mode
Provides Time Interval Error (TIE) correction
Accepts reference inputs from two independent
sources
•
Ordering Information
The MT9043 generates ST-BUS clock and framing
signals that are phase locked to either a 19.44 MHz,
2.048MHz, 1.544MHz, or 8kHz input reference.
The MT9043 is compliant with AT&T TR62411 and
Bellcore GR-1244-CORE, Stratum 4 Enhanced, and
Stratum 4; and ETSI ETS 300 011. It will meet the
jitter/wander tolerance, jitter transfer, intrinsic jitter,
frequency accuracy, capture range, phase change
slope, and MTIE requirements for these specifications.
JTAG Boundary Scan
Applications
•
•
Synchronization and timing control for multitrunk
T1,E1 and STS-3/OC3 systems
ST-BUS clock and frame pulse sources
OSCi
OSCo
LOCK
TCLR
Master Clock
TCK
TDI
TMS
TRST
TDO
IEEE
1149.1a
PRI
SEC
Reference
Select
MUX
TIE
Corrector
Circuit
DPLL
Input
Impairment
Monitor
State
Select
Control State Machine
Feedback
RST
Output
Interface
Circuit
State
Select
TIE
Corrector
Enable
MS
VSS
Virtual
Reference
Selected
Reference
Reference
Select
RSEL
VDD
IM
FLOCK
Frequency
Select
MUX
FS1
FS2
Figure 1 - Functional Block Diagram
Zarlink Semiconductor US Patent No. 5,602,884, UK Patent No. 0772912,
France Brevete S.G.D.G. 0772912; Germany DBP No. 69502724.7-08
1
Zarlink Semiconductor Inc.
Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc.
Copyright 2003, Zarlink Semiconductor Inc. All Rights Reserved.
C19o
C1.5o
C2o
C4o
C6o
C8o
C16o
F0o
F8o
F16o
RSP
TSP
MT9043
VSS
RST
TCLR
IC
SEC
PRI
Vdd
OSCo
OSCi
Vss
F16o
F0o
RSP
TSP
F8o
C1.5o
Vdd
LOCK
C2o
C4o
C19o
FLOCK
Vss
IC
1
48
2
47
3
46
45
4
5
44
6
43
42
7
8
41
40
9
10 MT9043AN 39
38
11
12
37
36
13
14
35
34
15
16
33
32
17
31
18
30
19
29
20
21
28
22
27
23
26
24
25
Data Sheet
TMS
TCK
TRST
TDI
TDO
IC
IC
FS1
FS2
IC
RSEL
IC
MS
Vdd
IC
IC
NC
Vss
IC
IM
Vdd
C6o
C16o
C8o
Figure 2 - Pin Connections
Pin Description
Pin #
Name
Description
1,10,
23,31
VSS
Ground. 0 Volts. (Vss pads).
2
RST
Reset (Input). A logic low at this input resets the MT9043. To ensure proper operation, the
device must be reset after reference signal frequency changes and power-up. The RST
pin should be held low for a minimum of 300ns. While the RST pin is low, all frame pulses
except RST and TSP and all clock outputs except C6o, C16o and C19o are at logic high.
The RST, TSP, C6o and C16o are at logic low during reset. The C19o is free-running
during reset. Following a reset, the input reference source and output clocks and frame
pulses are phase aligned as shown in Figure 12.
3
TCLR
TIE Circuit Reset (Input). A logic low at this input resets the Time Interval Error (TIE)
correction circuit resulting in a realignment of input phase with output phase as shown in
Figure 13. The TCLR pin should be held low for a minimum of 300ns. This pin is internally
pulled down to VSS.
4
IC
5
SEC
Secondary Reference (Input). This is one of two (PRI & SEC) input reference sources
(falling edge) used for synchronization. One of four possible frequencies (8kHz, 1.544MHz,
2.048MHz or 19.44MHz) may be used. The selection of the input reference is based upon the
MS, and RSEL, control inputs.This pin is internally pulled up to VDD.
6
PRI
Primary Reference (Input). See pin description for SEC. This pin is internally pulled up to
VDD.
7,17
28,35
VDD
Positive Supply Voltage. +3.3VDC nominal.
8
OSCo
Internal Connection. Leave open circuit.
Oscillator Master Clock (CMOS Output). For crystal operation, a 20MHz crystal is
connected from this pin to OSCi, see Figure 9. Not suitable for driving other devices. For
clock oscillator operation, this pin is left unconnected, see Figure 8.
2
Zarlink Semiconductor Inc.
MT9043
Data Sheet
Pin Description
Pin #
Name
Description
9
OSCi
Oscillator Master Clock (CMOS Input). For crystal operation, a 20MHz crystal is
connected from this pin to OSCo, see Figure 9. For clock oscillator operation, this pin is
connected to a clock source, see Figure 8.
11
F16o
Frame Pulse ST-BUS 8.192 Mb/s (CMOS Output). This is an 8kHz 61ns active low framing
pulse, which marks the beginning of an ST-BUS frame. This is typically used for ST-BUS
operation at 8.192 Mb/s. See Figure 14.
12
F0o
Frame Pulse ST-BUS 2.048Mb/s (CMOS Output). This is an 8kHz 244ns active low framing
pulse, which marks the beginning of an ST-BUS frame. This is typically used for ST-BUS
operation at 2.048Mb/s and 4.096Mb/s. See Figure 14.
13
RSP
Receive Sync Pulse (CMOS Output). This is an 8kHz 488ns active high framing pulse,
which marks the beginning of an ST-BUS frame. This is typically used for connection to the
Siemens MUNICH-32 device. See Figure 15.
14
TSP
Transmit Sync Pulse (CMOS Output). This is an 8kHz 488ns active high framing pulse,
which marks the beginning of an ST-BUS frame. This is typically used for connection to the
Siemens MUNICH-32 device. See Figure 15.
15
F8o
Frame Pulse (CMOS Output). This is an 8kHz 122ns active high framing pulse, which marks
the beginning of a frame. See Figure 14.
16
C1.5o
Clock 1.544MHz (CMOS Output). This output is used in T1 applications.
18
LOCK
Lock Indicator (CMOS Output). This output goes high when the PLL is frequency locked to
the input reference.
19
C2o
Clock 2.048MHz (CMOS Output). This output is used for ST-BUS operation at 2.048Mb/s.
20
C4o
Clock 4.096MHz (CMOS Output). This output is used for ST-BUS operation at 2.048Mb/s
and 4.096Mb/s.
21
C19o
Clock 19.44MHz (CMOS Output). This output is used in OC3/STS3 applications.
22
FLOCK
24
IC
25
C8o
26
C16o
Clock 16.384MHz (CMOS Output). This output is used for ST-BUS operation with a
16.384MHz clock.
27
C6o
Clock 6.312 Mhz (CMOS Output). This output is used for DS2 applications.
29
IM
Impairment Monitor (CMOS Output). A logic high on this pin indicates that the Input
Impairment Monitor has automatically put the device into Freerun Mode.
30
IC
Internal Connection. Tie high for normal operation.
32
NC
No Connection. Leave open circuit.
33,34
IC
Internal Connection. Tie low for normal operation.
36
MS
Mode/Control Select (Input). This input determines the state (Normal or Freerun) of
operation. The logic level at this input is gated in by the rising edge of F8o. See Table 3.
37
IC
Internal Connection. Tie low for normal operation.
Fast Lock Mode (Input). Set high to allow the PLL to quickly lock to the input reference (less
than 500 ms locking time).
Internal Connection. Tie low for normal operation.
Clock 8.192MHz (CMOS Output). This output is used for ST-BUS operation at 8.192Mb/s.
3
Zarlink Semiconductor Inc.
MT9043
Data Sheet
Pin Description
Pin #
Name
Description
38
RSEL
Reference Source Select (Input). A logic low selects the PRI (primary) reference source as
the input reference signal and a logic high selects the SEC (secondary) input. The logic level
at this input is gated in by the rising edge of F8o. See Table 2. This pin is internally pulled
down to VSS.
39
IC
40
FS2
Frequency Select 2 (Input). This input, in conjunction with FS1, selects which of four
possible frequencies (8kHz, 1.544MHz, 2.048MHz or 19.44MHz) may be input to the PRI and
SEC inputs. See Table 1.
41
FS1
Frequency Select 1 (Input). See pin description for FS2.
42
IC
Internal Connection. Tie Low for Normal Operation.
43
IC
Internal Connection. Leave Open Circuit.
44
TDO
Test Serial Data Out (CMOS Output). JTAG serial data is output on this pin on the falling
edge of TCK. This pin is held in high impedance state when JTAG scan is not enabled.
45
TDI
Test Serial Data In (Input). JTAG serial test instructions and data are shifted in on this pin.
This pin is internally pulled up to VDD.
46
TRST
Test Reset (Input). Asynchronously initializes the JTAG TAP controller by putting it in the
Test-Logic-Reset state. If not used, this pin should be held low.
47
TCK
Test Clock (Input). Provides the clock to the JTAG test logic. This pin is internally pulled up
to VDD.
48
TMS
Test Mode Select (Input). JTAG signal that controls the state transitions of the TAP
controller. This pin is internally pulled up to VDD.
Internal Connection. Tie low for normal operation.
Functional Description
The MT9043 is a Multitrunk System Synchronizer, providing timing (clock) and synchronization (frame) signals to
interface circuits for T1 and E1 Primary Rate Digital Transmission links. Figure 1 is a functional block diagram which
is described in the following sections.
Reference Select MUX Circuit
The MT9043 accepts two simultaneous reference input signals and operates on their falling edges. Either the
primary reference (PRI) signal or the secondary reference (SEC) signal can be selected as input to the TIE
Corrector Circuit. The selection is based on the Control, Mode and Reference Selection of the device. See Table 1
and Table 4.
Frequency Select MUX Circuit
The MT9043 operates with one of four possible input reference frequencies (8kHz, 1.544MHz, 2.048MHz or
19.44MHz). The frequency select inputs (FS1 and FS2) determine which of the four frequencies may be used at
the reference inputs (PRI and SEC). Both inputs must have the same frequency applied to them. A reset (RST)
must be performed after every frequency select input change. See Table 1.
4
Zarlink Semiconductor Inc.
MT9043
Data Sheet
FS2
FS1
Input Frequency
0
0
19.44MHz
1
8kHz
0
1.544MHz
1
2.048MHz
0
1
1
Table 1 - Input Frequency Selection
Time Interval Error (TIE) Corrector Circuit
The TIE corrector circuit, when enabled, prevents a step change in phase on the input reference signals (PRI or
SEC) from causing a step change in phase at the input of the DPLL block of Figure 1.
During reference input rearrangement, such as during a switch from the primary reference (PRI) to the secondary
reference (SEC), a step change in phase on the input signals will occur. A phase step at the input of the DPLL
would lead to unacceptable phase changes in the output signal.
As shown in Figure 3, the TIE Corrector Circuit receives one of the two reference (PRI or SEC) signals, passes the
signal through a programmable delay line, and uses this delayed signal as an internal virtual reference, which is
input to the DPLL. Therefore, the virtual reference is a delayed version of the selected reference.
TCLR
Resets Delay
Control
Circuit
Control Signal
Delay Value
PRI or SEC
from
Reference
Select Mux
Programmable
Delay Circuit
Virtual
Reference
to DPLL
Compare
Circuit
TIE Corrector
Enable
from
State Machine
Feedback
Signal from
Frequency
Select MUX
Figure 3 - TIE Corrector Circuit
During a switch from one reference to the other, the State Machine first changes the mode of the device
from Normal to Freerun. The Compare Circuit then measures the phase delay between the current phase
(feedback signal) and the phase of the new reference signal. This delay value is passed to the Programmable
Delay Circuit (See Figure 3). The state machine then returns the device to Normal Mode and the DPLL begins
using the new virtual reference signal. The difference between the phase position of the new virtual reference and
the previous reference is less than 1 µs.
Since internal delay circuitry maintains the alignment between the old virtual reference and the new virtual
reference, a phase error may exist between the selected input reference signal and the output signal of the DPLL.
This phase error is a function of the difference in phase between the two input reference signals during reference
5
Zarlink Semiconductor Inc.
MT9043
Data Sheet
rearrangements. Each time a reference switch is made, the delay between input signal and output signal will
change. The value of this delay is the accumulation of the error measured during each reference switch.
The programmable delay circuit can be zeroed by applying a logic low pulse to the TIE Circuit Reset (TCLR) pin. A
minimum reset pulse width is 300ns. This results in a phase alignment between the input reference signal and the
output signal as shown in Figure 13. The speed of the phase alignment correction is limited to 5ns per 125us, and
convergence is in the direction of least phase travel.
The state diagram of Figure 7 indicates the state changes during which the TIE corrector circuit is activated.
Digital Phase Lock Loop (DPLL)
As shown in Figure 4, the DPLL of the MT9043 consists of a Phase Detector, Limiter, Loop Filter, Digitally
Controlled Oscillator, and a Control Circuit.
Phase Detector - the Phase Detector compares the virtual reference signal from the TIE Corrector circuit with the
feedback signal from the Frequency Select MUX circuit, and provides an error signal corresponding to the phase
difference between the two. This error signal is passed to the Limiter circuit. The Frequency Select MUX allows the
proper feedback signal to be externally selected (e.g., 8kHz, 1.544MHz, 2.048MHz or 19.44MHz).
Limiter - the Limiter receives the error signal from the Phase Detector and ensures that the DPLL responds to all
input transient conditions with a maximum output phase slope of 5ns per 125us. This is well within the maximum
phase slope of 7.6ns per 125us or 81ns per 1.326ms specified by AT&T TR62411 and Bellcore GR-1244-CORE,
respectively.
Loop Filter - the Loop Filter is similar to a first order low pass filter with a 1.9 Hz cutoff frequency for all four
reference frequency selections (8kHz, 1.544MHz, 2.048MHz or 19.44MHz). This filter ensures that the jitter transfer
requirements in ETS 300 011 and AT&T TR62411 are met.
Control Circuit - the Control Circuit uses status and control information from the State Machine and the Input
Impairment Circuit to set the mode of the DPLL. The two possible modes are Normal and Freerun.
Virtual Reference
from
TIE Corrector
Phase
Detector
Feedback Signal
from
Frequency Select MUX
Limiter
Loop Filter
State Select
from
Input Impairment Monitor
Digitally
Controlled
Oscillator
DPLL Reference
to
Output Interface Circuit
Control
Circuit
State Select
from
State Machine
Figure 4 - DPLL Block Diagram
Digitally Controlled Oscillator (DCO) - the DCO receives the limited and filtered signal from the Loop Filter, and
based on its value, generates a corresponding digital output signal. The synchronization method of the DCO is
dependent on the state of the MT9043.
In Normal Mode, the DCO provides an output signal which is frequency and phase locked to the selected input
reference signal.
In Freerun Mode, the DCO is free running with an accuracy equal to the accuracy of the OSCi 20MHz source.
6
Zarlink Semiconductor Inc.
MT9043
Data Sheet
Lock Indicator - If the PLL is in frequency lock (frequency lock means the center frequency of the PLL is identical to
the line frequency), and the input phase offset is small enough such that no phase slope limiting is exhibited, then
the lock signal will be set high. For specific Lock Indicator design recommendations see the Applications - Lock
Indicator section.
Output Interface Circuit
The output of the DCO (DPLL) is used by the Output Interface Circuit to provide the output signals shown in Figure
5. The Output Interface Circuit uses four Tapped Delay Lines followed by a T1 Divider Circuit, an E1 Divider Circuit,
and a DS2 Divider Circuit to generate the required output signals.
Four tapped delay lines are used to generate 16.384MHz, 12.352MHz, 12.624MHz and 19.44 MHz signals.
The E1 Divider Circuit uses the 16.384MHz signal to generate four clock outputs and five frame pulse outputs. The
C8o, C4o and C2o clocks are generated by simply dividing the C16o clock by two, four and eight respectively.
These outputs have a nominal 50% duty cycle.
The T1 Divider Circuit uses the 12.384MHz signal to generate the C1.5o clock by dividing the internal C12 clock
by eight. This output has a nominal 50% duty cycle.
The DS2 Divider Circuit uses the 12.624 MHz signal to generate the clock output C6o. This output has a nominal
50% duty cycle.
T1 Divider
C1.5o
12MHz
Tapped
Delay
Line
E1 Divider
From
DPLL
Tapped
Delay
Line
Tapped
Delay
Line
Tapped
Delay
Line
16MHz
12MHz
DS2 Divider
19MHz
C2o
C4o
C8o
C16o
F0o
F8o
F16o
RSP
TSP
C6o
C19o
Figure 5 - Output Interface Circuit Block Diagram
The frame pulse outputs (F0o, F8o, F16o, TSP, and RSP) are generated directly from the C16 clock.
The T1 and E1 signals are generated from a common DPLL signal. Consequently, all frame pulse and clock outputs
are locked to one another for all operating states, and are also locked to the selected input reference in Normal
Mode. See Figures 14 & 15.
7
Zarlink Semiconductor Inc.
MT9043
Data Sheet
All frame pulse and clock outputs have limited driving capability, and should be buffered when driving high
capacitance (e.g., 30pF) loads.
Input Impairment Monitor
This circuit monitors the input signal to the DPLL for a complete loss of incoming signal, or a large frequency shift in
the incoming signal. If the input signal is outside the Impairment Monitor Capture Range the PLL automatically
changes from Normal Mode to Free Run Mode. See AC Electrical Characteristics - Performance for the Impairment
Monitor Capture Range. When the incoming signal returns to normal, the DPLL is returned to Normal Mode.
State Machine Control
As shown in Figure 1, this state machine controls the Reference Select MUX, the TIE Corrector Circuit and the
DPLL. Control is based on the logic levels at the control inputs RSEL and MS (See Figure 6).
All state machine changes occur synchronously on the rising edge of F8o. See the Control and Mode of Operation
section for full details.
To
Reference
Select MUX
To TIE
Corrector
Enable
To DPLL
State
Select
Control
State Machine
RSEL
MS
Figure 6 - Control State Machine Block Diagram
Master Clock
The MT9043 can use either a clock or crystal as the master timing source. For recommended master timing
circuits, see the Applications - Master Clock section.
Control and Mode of Operation
The active reference input (PRI or SEC) is selected by the RSEL pin as shown in Table 2.
RSEL
Input Reference
0
PRI
1
SEC
Table 2 - nput Reference Selection
MS
Mode
0
NORMAL
1
FREERUN
Table 3 - Operating Modes and States
The MT9043 has two possible modes of operation, Normal and Freerun.
8
Zarlink Semiconductor Inc.
MT9043
Data Sheet
As shown in Table 3, the Mode/Control Select pin MS selects the mode. Refer to Table 4 and Figure 7 for details of
the state change sequences.
Normal Mode
Normal Mode is typically used when a slave clock source, synchronized to the network is required.
In Normal Mode, the MT9043 provides timing (C1.5o, C2o, C4o, C8o, C16o and C19o) and frame synchronization
(F0o, F8o, F16o, TSP and RSP) signals, which are synchronized to one of two reference inputs (PRI or SEC). The
input reference signal may have a nominal frequency of 8kHz, 1.544MHz, 2.048MHz or 19.44MHz.
From a reset condition, the MT9043 will take up to 30 seconds (see AC Electrical Characteristics) of input reference
signal to output signals which are synchronized (phase locked) to the reference input.
The selection of input references is control dependent as shown in state table 4. The reference frequencies are
selected by the frequency control pins FS2 and FS1 as shown in Table 1.
Fast Lock Mode
Fast Lock Mode is a submode of Normal Mode, it is used to allow the MT9043 to lock to a reference more quickly
than Normal mode will allow. Typically, the PLL will lock to the incoming reference within 500 ms if the FLOCK pin is
set high.
Freerun Mode
Freerun Mode is typically used when a master clock source is required, or immediately following system power-up
before network synchronization is achieved.
In Freerun Mode, the MT9043 provides timing and synchronization signals which are based on the master clock
frequency (OSCi) only, and are not synchronized to the reference signals (PRI and SEC).
The accuracy of the output clock is equal to the accuracy of the master clock (OSCi). So if a ±32ppm output clock
is required, the master clock must also be ±32ppm. See Applications - Crystal and Clock Oscillator sections.
MT9043 Measures of Performance
The following are some synchronizer performance indicators and their corresponding definitions.
Intrinsic Jitter
Intrinsic jitter is the jitter produced by the synchronizing circuit and is measured at its output. It is measured by
applying a reference signal with no jitter to the input of the device, and measuring its output jitter. Intrinsic jitter may
also be measured when the device is free running by measuring the output jitter of the device. Intrinsic jitter is
usually measured with various bandlimiting filters depending on the applicable standards. In the MT9043, the
intrinsic Jitter is limited to less than 0.02UI on the 2.048MHz and 1.544MHz clocks.
Jitter Tolerance
Jitter tolerance is a measure of the ability of a PLL to operate properly (i.e., remain in lock and or regain lock in the
presence of large jitter magnitudes at various jitter frequencies) when jitter is applied to its reference. The applied
jitter magnitude and jitter frequency depends on the applicable standards.
Jitter Transfer
Jitter transfer or jitter attenuation refers to the magnitude of jitter at the output of a device for a given amount of jitter
at the input of the device. Input jitter is applied at various amplitudes and frequencies, and output jitter is measured
with various filters depending on the applicable standards.
9
Zarlink Semiconductor Inc.
MT9043
Data Sheet
For the MT9043, two internal elements determine the jitter attenuation. This includes the internal 1.9Hz low pass
loop filter and the phase slope limiter. The phase slope limiter limits the output phase slope to 5ns/125us.
Therefore, if the input signal exceeds this rate, such as for very large amplitude low frequency input jitter, the
maximum output phase slope will be limited (i.e., attenuated) to 5ns/125us.
The MT9043 has twelve outputs with three possible input frequencies (except for 19.44MHz, which is internally
divided to 8KHz) for a total of 36 possible jitter transfer functions. Since all outputs are derived from the same
signal, the jitter transfer values for the four cases, 8kHz to 8kHz, 1.544MHz to 1.544MHz and 2.048MHz to
2.048MHz can be applied to all outputs.
It should be noted that 1UI at 1.544MHz is 644ns, which is not equal to 1UI at 2.048MHz, which is 488ns.
Consequently, a transfer value using different input and output frequencies must be calculated in common units
(e.g., seconds) as shown in the following example.
What is the T1 and E1 output jitter when the T1 input jitter is 20UI (T1 UI Units) and the T1 to T1 jitter attenuation is
18dB?
A
 –----- 20 
OutputT1 = InputT1 ×10
18-
 –------- 20 
OutputT1 = 20 ×10
= 2.5UI ( T1 )
( 1UIT1 )
OutputE1 = OutputT1 × ---------------------( 1UIE1 )
( 644ns )
OutputE1 = OutputT1 × ------------------- = 3.3UI ( T1 )
( 488ns )
Using the above method, the jitter attenuation can be calculated for all combinations of inputs and outputs based on
the three jitter transfer functions provided.
Note that the resulting jitter transfer functions for all combinations of inputs (8kHz, 1.544MHz, 2.048MHz) and
outputs (8kHz, 1.544MHz, 2.048MHz, 4.096MHz, 8.192MHz, 16.384MHz, 19.44MHz) for a given input signal (jitter
frequency and jitter amplitude) are the same.
Since intrinsic jitter is always present, jitter attenuation will appear to be lower for small input jitter signals than for
large ones. Consequently, accurate jitter transfer function measurements are usually made with large input jitter
signals (e.g., 75% of the specified maximum jitter tolerance).
Frequency Accuracy
Frequency accuracy is defined as the absolute tolerance of an output clock signal when it is not locked to an
external reference, but is operating in a free running mode. For the MT9043, the Freerun accuracy is equal to the
Master Clock (OSCi) accuracy.
Capture Range
Also referred to as pull-in range. This is the input frequency range over which the synchronizer must be able to pull
into synchronization. The MT9043 capture range is equal to ±230 ppm minus the accuracy of the master clock
(OSCi). For example, a 32 ppm master clock results in a capture range of 198 ppm.
Lock Range
This is the input frequency range over which the synchronizer must be able to maintain synchronization. The lock
range is equal to the capture range for the MT9043.
10
Zarlink Semiconductor Inc.
MT9043
Data Sheet
Phase Slope
Phase slope is measured in seconds per second and is the rate at which a given signal changes phase with respect
to an ideal signal. The given signal is typically the output signal. The ideal signal is of constant frequency and is
nominally equal to the value of the final output signal or final input signal.
Time Interval Error (TIE)
TIE is the time delay between a given timing signal and an ideal timing signal.
Maximum Time Interval Error (MTIE)
MTIE is the maximum peak to peak delay between a given timing signal and an ideal timing signal within a
particular observation period.
MTIE ( S ) = TIEmax ( t ) – TIEmin ( t )
Phase Continuity
Phase continuity is the phase difference between a given timing signal and an ideal timing signal at the end of a
particular observation period. Usually, the given timing signal and the ideal timing signal are of the same frequency.
Phase continuity applies to the output of the synchronizer after a signal disturbance due to a reference switch or a
mode change. The observation period is usually the time from the disturbance, to just after the synchronizer has
settled to a steady state.
In the case of the MT9043, the output signal phase continuity is maintained to within ±5ns at the instance (over one
frame) of all reference switches and all mode changes. The total phase shift, depending on the switch or type of
mode change, may accumulate up to 200 ns over many frames. The rate of change of the 200 ns phase shift is
limited to a maximum phase slope of approximately 5ns/125us. This meets the AT&T TR62411 maximum phase
slope requirement of 7.6ns/125us and Bellcore GR-1244-CORE (81ns/1.326ms).
Phase Lock Time
This is the time it takes the synchronizer to phase lock to the input signal. Phase lock occurs when the input signal
and output signal are not changing in phase with respect to each other (not including jitter).
Lock time is very difficult to determine because it is affected by many factors which include:
•
initial input to output phase difference
•
initial input to output frequency difference
•
synchronizer loop filter
•
synchronizer limiter
Although a short lock time is desirable, it is not always possible to achieve due to other synchronizer requirements.
For instance, better jitter transfer performance is achieved with a lower frequency loop filter which increases lock
time. And better (smaller) phase slope performance (limiter) results in longer lock times. The MT9043 loop filter and
limiter were optimized to meet the AT&T TR62411 jitter transfer and phase slope requirements. Consequently,
phase lock time, which is not a standards requirement, may be longer than in other applications. See AC Electrical
Characteristics - Performance for Maximum Phase Lock Time.
MT9043 provides a fast lock pin (FLOCK), which, when set high enables the PLL to lock to an incoming reference
within approximately 500 ms.
11
Zarlink Semiconductor Inc.
MT9043
Data Sheet
Description
State
Input Controls
Freerun
Normal (PRI)
Normal (SEC)
MS
RSEL
S0
S1
S2
0
0
S1
-
S1 MTIE
0
1
S2
S2 MTIE
-
1
X
-
S0
S0
Legend:
No Change
MTIE
State change occurs with TIE Corrector Circuit
Refer to Control State Diagram for state changes to and from Auto-Freerun State
Table 4 - Control State Table
S0
Freerun
(1X)
S1
Normal
Primary
(00)
{A}
NOTES:
(XX)
MS RSEL
{A}
Invalid Reference Signal
S1A
Auto-Freerun
Primary
(00)
S2A
Auto-Freerun
Secondary
(01)
{A}
S2
Normal
Secondary
(01)
Phase Re-Alignment
Phase Continuity Maintained (without TIE Corrector Circuit)
Phase Continuity Maintained (with TIE Corrector Circuit)
Movement to Normal State from any
state requires a valid input signal
Figure 7 - Control State Diagram
MT9043 and Network Specifications
The MT9043 fully meets all applicable PLL requirements (intrinsic jitter, jitter/wander tolerance, jitter/wander
transfer, frequency accuracy, capture range, phase change slope and MTIE during reference rearrangement) for
the following specifications.
1. Bellcore GR-1244-CORE June 1995 for, Stratum 4 Enhanced and Stratum 4
2. AT&T TR62411 (DS1) December 1990 for, Stratum 4 Enhanced and Stratum 4
3. ANSI T1.101 (DS1) February 1994 for Stratum 4 Enhanced and Stratum 4
4. ETSI 300 011 (E1) April 1992 for Single Access and Multi Access
12
Zarlink Semiconductor Inc.
MT9043
Data Sheet
5. TBR 4 November 1995
6. TBR 12 December 1993
7. TBR 13 January 1996
8. ITU-T I.431 March 1993
Applications
This section contains MT9043 application specific details for clock and crystal operation, reset operation, power
supply de coupling, and control operation.
Master Clock
The MT9043 can use either a clock or crystal as the master timing source.
In Freerun Mode, the frequency tolerance at the clock outputs is identical to the frequency tolerance of the source
at the OSCi pin. For applications not requiring an accurate Freerun Mode, tolerance of the master timing source
may be ±100ppm. For applications requiring an accurate Freerun Mode, such as AT&T TR62411, the tolerance of
the master timing source must be no greater than ±32ppm.
Another consideration in determining the accuracy of the master timing source is the desired capture range. The
sum of the accuracy of the master timing source and the capture range of the MT9043 will always equal 230ppm.
For example, if the master timing source is 100ppm, then the capture range will be 130ppm.
Clock Oscillator - when selecting a Clock Oscillator, numerous parameters must be considered. This includes
absolute frequency, frequency change over temperature, output rise and fall times, output levels and duty cycle.
MT9043
OSCi
+3.3V
+3.3V
20MHz OUT
GND
0.1uF
OSCo
No Connection
Figure 8 - Clock Oscillator Circuit
For applications requiring ±32ppm clock accuracy, the following clock oscillator module may be used.
FOX F7C-2E3-20.0MHz
Frequency:
Tolerance:
Rise & Fall Time:
Duty Cycle:
20MHz
25ppm 0C to 70C
10ns (0.33V 2.97V 15pF)
40% to 60%
CTS CB3LV-5I-20.0 MHz
Frequency:
Tolerance:
Rise & Fall Time:
Duty Cycle:
20MHz
25ppm
10ns
45% to 55%
13
Zarlink Semiconductor Inc.
MT9043
Data Sheet
The output clock should be connected directly (not AC coupled) to the OSCi input of the MT9043, and the OSCo
output should be left open as shown in Figure 8.
Crystal Oscillator - Alternatively, a Crystal Oscillator may be used. A complete oscillator circuit made up of a
crystal, resistor and capacitors is shown in Figure 9.
MT9043
OSCi
20MHz
1MΩ
56pF
39pF
3-50pF
OSCo
100Ω
1uH
1uH inductor: may improve stability and is optional
Figure 9 - Crystal Oscillator Circuit
The accuracy of a crystal oscillator depends on the crystal tolerance as well as the load capacitance tolerance.
Typically, for a 20MHz crystal specified with a 32pF load capacitance, each 1pF change in load capacitance
contributes approximately 9ppm to the frequency deviation. Consequently, capacitor tolerances, and stray
capacitances have a major effect on the accuracy of the oscillator frequency.
The trimmer capacitor shown in Figure 9 may be used to compensate for capacitive effects. If accuracy is not a
concern, then the trimmer may be removed, the 39pF capacitor may be increased to 56pF, and a wider tolerance
crystal may be substituted.
The crystal should be a fundamental mode type - not an overtone. The fundamental mode crystal permits a simpler
oscillator circuit with no additional filter components and is less likely to generate spurious responses. The crystal
specification is as follows.
Frequency:
20MHz
Tolerance:
As required
Oscillation Mode:
Fundamental
Resonance Mode:
Parallel
Load Capacitance:
32pF
Maximum Series Resistance:
35Ω
Approximate Drive Level:
1mW
e.g., R1B23B32-20.0MHz
(20ppm absolute, ±6ppm 0C to 50C, 32pF, 25Ω)
Reset Circuit
A simple power up reset circuit with about a 50us reset low time is shown in Figure 10. Resistor RP is for protection
only and limits current into the RST pin during power down conditions. The reset low time is not critical but should
be greater than 300ns.
14
Zarlink Semiconductor Inc.
MT9043
Data Sheet
MT9043
+3.3V
R
10kΩ
RST
RP
1kΩ
C
10nF
Figure 10 - Power-Up Reset Circuit
Lock Indicator
The LOCK pin toggles at a random rate when the PLL is frequency locked to the input reference. In Figure 11 the
RC-time-constant circuit can be used to hold the high state of the LOCK pin.
Once the PLL is frequency locked to the input reference, the minimum duration of LOCK pin’s high state would be
32ms and the maximum duration of LOCK pin’s low state would not exceed 1 second. The following equations can
be used to calculate the charge and discharge times of the capacitor.
tC = - RD C ln(1 – VT+ /VDD) = 240 µs
tC = Capacitor’s charge time
RD = Dynamic resistance of the diode (100 Ω)
C = Capacitor value (1µF)
VT+ = Positive going threshold voltage of the
Schmitt Trigger (3.0 V)
VDD = 3.3 V
tD = - R C ln(VT- /VDD) = 1.65 seconds
tD = Capacitor’s discharge time
R = Resistor value (3.3 MΩ)
C = Capacitor value (1µF)
VT- = Negative going threshold voltage of the
Schmitt Trigger (2.0 V)
VDD = 3.3 V
15
Zarlink Semiconductor Inc.
MT9043
MT9043
R=3.3M
74HC14
Data Sheet
74HC14
LOCK
Lock
IN4148
+
C=1µf
Figure 11 - Time-constant Circuit
A digital alternative to the RC-time-constant circuit is presented in Figure 12. The circuit in Figure 12 can be used to
generate a steady lock signal. The circuit monitors the MT9043’s LOCK pin, as long as it detects a positive pulse
every 1.024 seconds or less, the Advanced Lock output will remain high. If no positive pulse is detected on the
LOCK output within 1.024 seconds, the Advanced LOCK output will go low.
MT9043
Figure 12 - Digital Lock Pin Circuit
16
Zarlink Semiconductor Inc.
MT9043
Data Sheet
Absolute Maximum Ratings* - Voltages are with respect to ground (VSS) unless otherwise stated.
Parameter
Symbol
Min
Max
Units
1
Supply voltage
VDD
-0.3
7.0
V
2
Voltage on any pin
VPIN
-0.3
VDD+ 0.3
V
3
Current on any pin
IPIN
30
mA
4
Storage temperature
TST
125
°C
5 48 SSOP package power dissipation
PPD
200
* Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied.
mW
-55
Recommended Operating Conditions - Voltages are with respect to ground (VSS) unless otherwise stated.
Characteristics
1
Supply voltage
2
Operating temperature
Sym
Min
Max
Units
VDD
3.0
3.6
V
TA
-40
85
°C
DC Electrical Characteristics* - Voltages are with respect to ground (VSS) unless otherwise stated.
Characteristics
1
Supply current with:
2
Sym
OSCi = 0V
OSCi = Clock
Min
Max
Units
IDDS
1.8
mA
Outputs unloaded
IDD
50
mA
Outputs unloaded
0.7VDD
Conditions/Notes
3
CMOS high-level input voltage
VCIH
V
4
CMOS low-level input voltage
VCIL
0.3VDD
V
5
Input leakage current
IIL
15
µA
VI=VDD or 0V
6
High-level output voltage
VOH
V
IOH= 10 mA
7
Low-level output voltage
VOL
V
IOL= 10 mA
2.4
0.4
* Supply voltage and operating temperature are as per Recommended Operating Conditions.
17
Zarlink Semiconductor Inc.
MT9043
Data Sheet
AC Electrical Characteristics - Performance
Characteristics
1
Sym
±0ppm
Freerun Mode accuracy with OSCi at:
Min
Max
Units
Conditions/
Notes†
-0
+0
ppm
4-8
2
±32ppm
-32
+32
ppm
4-8
3
±100ppm
-100
+100
ppm
4-8
-230
+230
ppm
1-3,5-8
4
±0ppm
Capture range with OSCi at:
5
±32ppm
-198
+198
ppm
1-3,5-8
6
±100ppm
-130
+130
ppm
1-3,5-8
30
s
1-3,5-14
reference switch
200
ns
1-3,5-14
9
mode switch to Normal
200
ns
1-2,4-14
10
mode switch to Freerun
200
ns
1-3,5-14
7
Phase lock time
8
Output phase continuity with:
11
MTIE (maximum time interval error)
600
ns
1-14,27
12
Output phase slope
45
us/s
1-14,27
13
Impairment Monitor Capture Range at: 8kHz, 19.44MHz
-30k
+30k
ppm
1-3,5,8,9-11
14
1.544MHz
-30k
+30k
ppm
1-3,6,9-11
15
2.048MHz
-30k
+30k
ppm
1-3,7,9-11
† See “Notes” following AC Electrical Characteristics tables.
AC Electrical Characteristics - Timing Parameter Measurement Voltage Levels* - Voltages are
with respect to ground (VSS) unless otherwise stated
Characteristics
1
Threshold Voltage
2
Rise and Fall Threshold Voltage High
Sym
CMOS
Units
VT
0.5VDD
V
VHM
0.7VDD
V
0.3VDD
V
3
Rise and Fall Threshold Voltage Low
VLM
* Supply voltage and operating temperature are as per Recommended Operating Conditions.
* Timing for input and output signals is based on the worst case result of the CMOS thresholds.
* See Figure 10.
Timing Reference Points
V HM
VT
V LM
ALL SIGNALS
tIRF, tORF
tIRF, tORF
Figure 13 - Timing Parameter Measurement Voltage Levels
18
Zarlink Semiconductor Inc.
MT9043
Data Sheet
AC Electrical Characteristics - Input/Output Timing
Characteristics
Sym
Min
100
1
Reference input pulse width high or low
tRW
2
Reference input rise or fall time
tIRF
3
8kHz reference input to F8o delay
tR8D
4
1.544MHz reference input to F8o delay
5
Max
Units
ns
10
ns
-21
6
ns
tR15D
337
363
ns
2.048MHz reference input to F8o delay
tR2D
222
238
ns
6
19.44MHz reference input to F8o delay
tR19D
46
57
ns
7
F8o to F0o delay
tF0D
111
130
ns
8
F16o setup to C16o falling
tF16S
25
40
ns
9
F16o hold to C16o rising
tF16H
-10
10
ns
10
F8o to C1.5o delay
tC15D
-45
-25
ns
11
F8o to C6o delay
tC6D
-10
10
ns
12
F8o to C2o delay
tC2D
-11
5
ns
13
F8o to C4o delay
tC4D
-11
5
ns
14
F8o to C8o delay
tC8D
-11
5
ns
15
F8o to C16o delay
tC16D
-11
5
ns
16
F8o to TSP delay
tTSPD
-6
10
ns
17
F8o to RSP delay
tRSPD
-8
8
ns
18
F8o to C19o delay
tC19D
-15
5
ns
19
C1.5o pulse width high or low
tC15W
309
339
ns
20
C6o pulse width high or low
tC6W
70
86
ns
21
C2o pulse width high or low
tC2W
230
258
ns
22
C4o pulse width high or low
tC4W
111
133
ns
23
C8o pulse width high or low
tC8W
52
70
ns
24
C16o pulse width high or low
tC16WL
24
35
ns
25
TSP pulse width high
tTSPW
478
494
ns
26
RSP pulse width high
tRSPW
474
491
ns
27
C19o pulse width high
tC19WH
25
35
ns
28
C19o pulse width low
tC19WL
17
25
ns
29
F0o pulse width low
tF0WL
234
254
ns
30
F8o pulse width high
tF8WH
109
135
ns
31
F16o pulse width low
tF16WL
47
75
ns
32
Output clock and frame pulse rise or fall time
9
ns
33
Input Controls Setup Time
tS
100
ns
34
Input Controls Hold Time
tH
100
ns
tORF
19
Zarlink Semiconductor Inc.
MT9043
Data Sheet
tR8D
PRI/SEC
8kHz
tRW
tR15D
PRI/SEC
1.544MHz
VT
tRW
VT
tR2D
PRI/SEC
2.048MHz
tRW
VT
tR19D
PRI/SEC
19.44MHz
tRW
VT
F8o
VT
NOTES:
1. Input to output delay values
are valid after a TCLR or RST
with no further state changes
Figure 14 - Input to Output Timing (Normal Mode)
20
Zarlink Semiconductor Inc.
MT9043
Data Sheet
tF8WH
VT
F8o
tF0WL
tF0D
VT
F0o
tF16WL
VT
F16o
tF16S
tC16WL
tF16H
tC16D
VT
C16o
tC8W
tC8W
tC8D
VT
C8o
tC4W
tC4W
tC4D
VT
C4o
tC2W
tC2D
VT
C2o
tC6W
tC6D
tC6W
VT
C6o
tC15W
tC15D
VT
C1.5o
tC19WH
tC19WL
C19o
tC19D
VT
Figure 14 - Output Timing 1
21
Zarlink Semiconductor Inc.
MT9043
Data Sheet
F8o
VT
VT
C2o
tRSPD
VT
RSP
tRSPW
tTSPW
TSP
VT
tTSPD
Figure 15 - Output Timing 2
VT
F8o
tS
tH
MS1,2,
RSEL,
PCCi
VT
Figure 16 - Input Controls Setup and Hold Timing
AC Electrical Characteristics - Intrinsic Jitter Unfiltered
Characteristics
Sym
Max
Units
Conditions/Notes†
1
Intrinsic jitter at F8o (8kHz)
0.0002
UIpp
1-14,21-24,28
2
Intrinsic jitter at F0o (8kHz)
0.0002
UIpp
1-14,21-24,28
3
Intrinsic jitter at F16o (8kHz)
0.0002
UIpp
1-14,21-24,28
4
Intrinsic jitter at C1.5o (1.544MHz)
0.030
UIpp
1-14,21-24,29
5
Intrinsic jitter at C2o (2.048MHz)
0.040
UIpp
1-14,21-24,30
6
Intrinsic jitter at C6o (6.312MHz)
0.120
UIpp
1-14,21-24,31
7
Intrinsic jitter at C4o (4.096MHz)
0.080
UIpp
1-14,21-24,32
8
Intrinsic jitter at C8o (8.192MHz)
0.104
UIpp
1-14,21-24,33
9
Intrinsic jitter at C16o (16.384MHz)
0.104
UIpp
1-14,21-24,34
10
Intrinsic jitter at TSP (8kHz)
0.0002
UIpp
1-14,21-24,34
11
Intrinsic jitter at RSP (8kHz)
0.0002
UIpp
1-14,21-24,34
12
Intrinsic jitter at C19o (19.44MHz)
0.27
UIpp
1-14,21-24,35
† See “Notes” following AC Electrical Characteristics tables.
22
Zarlink Semiconductor Inc.
MT9043
Data Sheet
AC Electrical Characteristics - C1.5o (1.544MHz) Intrinsic Jitter Filtered
Characteristics
Sym
Min
Max
Units
Conditions/Notes†
1
Intrinsic jitter (4Hz to 100kHz filter)
0.015
UIpp
1-14,21-24,29
2
Intrinsic jitter (10Hz to 40kHz filter)
0.010
UIpp
1-14,21-24,29
3
Intrinsic jitter (8kHz to 40kHz filter)
0.010
UIpp
1-14,21-24,29
4
Intrinsic jitter (10Hz to 8kHz filter)
0.005
UIpp
1-14,21-24,29
† See “Notes” following AC Electrical Characteristics tables.
AC Electrical Characteristics - C2o (2.048MHz) Intrinsic Jitter Filtered
Characteristics
Sym
Min
Max
Units
Conditions/Notes†
1
Intrinsic jitter (4Hz to 100kHz filter)
0.015
UIpp
1-14,21-24,30
2
Intrinsic jitter (10Hz to 40kHz filter)
0.010
UIpp
1-14,21-24,30
3
Intrinsic jitter (8kHz to 40kHz filter)
0.010
UIpp
1-14,21-24,30
4
Intrinsic jitter (10Hz to 8kHz filter)
0.005
UIpp
1-14,21-24,30
† See “Notes” following AC Electrical Characteristics tables.
AC Electrical Characteristics - 8kHz Input to 8kHz Output Jitter Transfer
Characteristics
Sym
Min
Max
Units
Conditions/Notes†
1
Jitter attenuation for [email protected] input
0
6
dB
1-3, 5, 9-14,
21-22, 24, 28, 36
2
Jitter attenuation for [email protected] input
6
16
dB
1-3, 5, 9-14,
21-22, 24, 28, 36
3
Jitter attenuation for [email protected] input
12
22
dB
1-3, 5, 9-14,
21-22, 24, 28, 36
4
Jitter attenuation for [email protected] input
28
38
dB
1-3, 5, 9-14,
21-22, 24, 28, 36
5
Jitter attenuation for [email protected] input
42
dB
1-3, 5, 9-14,
21-22, 24, 28, 36
6
Jitter attenuation for [email protected] input
45
dB
1-3, 5, 9-14,
21-22, 24, 28, 36
† See “Notes” following AC Electrical Characteristics tables.
23
Zarlink Semiconductor Inc.
MT9043
Data Sheet
AC Electrical Characteristics - 1.544MHz Input to 1.544MHz Output Jitter Transfer
Characteristics
Sym
Min
Max
Units
Conditions/Notes†
1
Jitter attenuation for 1Hz@20UIpp input
0
6
dB
1-3,6,9-14,
21-22,24,29,36
2
Jitter attenuation for 1Hz@104UIpp input
6
16
dB
1-3,6,9-14,
21-22,24,29,36
3
Jitter attenuation for 10Hz@20UIpp input
12
22
dB
1-3,6,9-14,
21-22,24,29,36
4
Jitter attenuation for 60Hz@20UIpp input
28
38
dB
1-3,6,9-14,
21-22,24,29,36
5
Jitter attenuation for 300Hz@20UIpp input
42
dB
1-3,6,9-14,
21-22,24,29,36
6
Jitter attenuation for [email protected] input
45
dB
1-3,6,9-14,
21-22,24,29,36
7
Jitter attenuation for [email protected] input
45
dB
1-3,6,9-14,
21-22,24,29,36
† See “Notes” following AC Electrical Characteristics tables.
24
Zarlink Semiconductor Inc.
MT9043
Data Sheet
AC Electrical Characteristics - 2.048MHz Input to 2.048MHz Output Jitter Transfer
Characteristics
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Sym
Min
Jitter at output for [email protected] input
with 40Hz to 100kHz filter
Jitter at output for [email protected] input
with 40Hz to 100kHz filter
Jitter at output for [email protected] input
with 40Hz to 100kHz filter
Jitter at output for [email protected] input
with 40Hz to 100kHz filter
Jitter at output for [email protected] input
with 40Hz to 100kHz filter
Jitter at output for [email protected] input
with 40Hz to 100kHz filter
Jitter at output for [email protected] input
with 40Hz to 100kHz filter
† See “Notes” following AC Electrical Characteristics tables.
25
Zarlink Semiconductor Inc.
Max
Units
Conditions/Notes†
2.9
UIpp
1-3,7,9-14,
21-22,24,30,36
0.09
UIpp
1-3,7,9-14,
21-22,24,30,37
1.3
UIpp
1-3,7,9-14,
21-22,24,30,36
0.10
UIpp
1-3,7,9-14,
21-22,24,30,37
0.80
UIpp
1-3,7,9-14,
21-22,24,30,36
0.10
UIpp
1-3,7,9-14,
21-22,24,30,37
0.40
UIpp
1-3,7,9-14,
21-22,24,30,36
0.10
UIpp
1-3,7,9-14,
21-22,24,30,37
0.06
UIpp
1-3,7,9-14,
21-22,24,30,36
0.05
UIpp
1-3,7,9-14,
21-22,24,30,37
0.04
UIpp
1-3,7,9-14,
21-22,24,30,36
0.03
UIpp
1-3,7,9-14,
21-22,24,30,37
0.04
UIpp
1-3,7,9-14,
21-22,24,30,36
0.02
UIpp
1-3,7,9-14,
21-22,24,30,35
MT9043
Data Sheet
AC Electrical Characteristics - 8kHz Input Jitter Tolerance
Characteristics
Sym
Min
Max
Units
Conditions/Notes†
1
Jitter tolerance for 1Hz input
0.80
UIpp
1-3,5,9 -14,21-22,24-26,28
2
Jitter tolerance for 5Hz input
0.70
UIpp
1-3,5,9 -14,21-22,24-26,28
3
Jitter tolerance for 20Hz input
0.60
UIpp
1-3,5,9 -14,21-22,24-26,28
4
Jitter tolerance for 300Hz input
0.20
UIpp
1-3,5,9 -14,21-22,24-26,28
5
Jitter tolerance for 400Hz input
0.15
UIpp
1-3,5,9 -14,21-22,24-26,28
6
Jitter tolerance for 700Hz input
0.08
UIpp
1-3,5,9 -14,21-22,24-26,28
7
Jitter tolerance for 2400Hz input
0.02
UIpp
1-3,5,9 -14,21-22,24-26,28
8
Jitter tolerance for 3600Hz input
0.01
UIpp
1-3,5,9 -14,21-22,24-26,28
† See “Notes” following AC Electrical Characteristics tables.
AC Electrical Characteristics - 1.544MHz Input Jitter Tolerance
Characteristics
Sym
Min
Max
Units
Conditions/Notes†
1
Jitter tolerance for 1Hz input
150
UIpp
1-3,6,9 -14,21-22,24-26,29
2
Jitter tolerance for 5Hz input
140
UIpp
1-3,6,9 -14,21-22,24-26,29
3
Jitter tolerance for 20Hz input
130
UIpp
1-3,6,9 -14,21-22,24-26,29
4
Jitter tolerance for 300Hz input
35
UIpp
1-3,6,9 -14,21-22,24-26,29
5
Jitter tolerance for 400Hz input
25
UIpp
1-3,6,9 -14,21-22,24-26,29
6
Jitter tolerance for 700Hz input
15
UIpp
1-3,6,9 -14,21-22,24-26,29
7
Jitter tolerance for 2400Hz input
4
UIpp
1-3,6,9 -14,21-22,24-26,29
8
Jitter tolerance for 10kHz input
1
UIpp
1-3,6,9 -14,21-22,24-26,29
9
Jitter tolerance for 100kHz input
0.5
UIpp
1-3,6,9 -14,21-22,24-26,29
† See “Notes” following AC Electrical Characteristics tables.
AC Electrical Characteristics - 2.048MHz Input Jitter Tolerance
Characteristics
Sym
Min
Max
Units
Conditions/Notes†
1
Jitter tolerance for 1Hz input
150
UIpp
1-3,7,9 -14,21-22,24-26,30
2
Jitter tolerance for 5Hz input
140
UIpp
1-3,7,9 -14,21-22,24-26,30
3
Jitter tolerance for 20Hz input
130
UIpp
1-3,7,9 -14,21-22,24-26,30
4
Jitter tolerance for 300Hz input
50
UIpp
1-3,7,9 -14,21-22,24-26,30
5
Jitter tolerance for 400Hz input
40
UIpp
1-3,7,9 -14,21-22,24-26,30
6
Jitter tolerance for 700Hz input
20
UIpp
1-3,7,9 -14,21-22,24-26,30
7
Jitter tolerance for 2400Hz input
5
UIpp
1-3,7,9 -14,21-22,24-26,30
8
Jitter tolerance for 10kHz input
1
UIpp
1-3,7,9 -14,21-22,24-26,30
9
Jitter tolerance for 100kHz input
1
UIpp
1-3,7,9 -14,21-22,24-26,30
† See “Notes” following AC Electrical Characteristics tables.
26
Zarlink Semiconductor Inc.
MT9043
Data Sheet
AC Electrical Characteristics - OSCi 20MHz Master Clock Input
Characteristics
Min
Max
Units
-0
+0
ppm
15,18
2
-32
+32
ppm
16,19
3
-100
+100
ppm
17,20
40
60
%
1
Sym
Tolerance
4
Duty cycle
5
Rise time
10
ns
6
Fall time
10
ns
Conditions/Notes†
† See “Notes” following AC Electrical Characteristics tables.
† Notes:
Voltages are with respect to ground (VSS) unless otherwise stated.
Supply voltage and operating temperature are as per Recommended Operating Conditions.
Timing parameters are as per AC Electrical Characteristics - Timing Parameter Measurement Voltage Levels
1. PRI reference input selected.
2. SEC reference input selected.
3. Normal Mode selected.
4. Freerun Mode selected.
5. 8kHz Frequency Mode selected.
6. 1.544MHz Frequency Mode selected.
7. 2.048MHz Frequency Mode selected.
8. 19.44MHz Frequency Mode selected.
9. Master clock input OSCi at 20MHz ±0ppm.
10. Master clock input OSCi at 20MHz ±32ppm.
11. Master clock input OSCi at 20MHz ±100ppm.
12. Selected reference input at ±0ppm.
13. Selected reference input at ±32ppm.
14. Selected reference input at ±100ppm.
15. For Freerun Mode of ±0ppm.
16. For Freerun Mode of ±32ppm.
17. For Freerun Mode of ±100ppm.
18. For capture range of ±230ppm.
19. For capture range of ±198ppm.
20. For capture range of ±130ppm.
21. 25pF capacitive load.
22. OSCi Master Clock jitter is less than 2nspp, or 0.04UIpp where1UIpp=1/20MHz.
23. Jitter on reference input is less than 7nspp.
24. Applied jitter is sinusoidal.
25. Minimum applied input jitter magnitude to regain synchronization.
26. Loss of synchronization is obtained at slightly higher input jitter amplitudes.
27. Within 10ms of the state, reference or input change.
28. 1UIpp = 125us for 8kHz signals.
29. 1UIpp = 648ns for 1.544MHz signals.
30. 1UIpp = 488ns for 2.048MHz signals.
31. 1UIpp = 323ns for 3.088MHz signals.
32. 1UIpp = 244ns for 4.096MHz signals.
33. 1UIpp = 122ns for 8.192MHz signals.
34. 1UIpp = 61ns for 16.384MHz signals.
35. 1UIpp = 51.44ns for 19.44MHz signals.
36. No filter.
37. 40Hz to 100kHz bandpass filter.
38. With respect to reference input signal frequency.
39. After a RST or TCLR.
40. Master clock duty cycle 40% to 60%.
27
Zarlink Semiconductor Inc.
Package Code
c Zarlink Semiconductor 2003 All rights reserved.
ISSUE
ACN
DATE
APPRD.
Previous package codes
For more information about all Zarlink products
visit our Web Site at
www.zarlink.com
Information relating to products and services furnished herein by Zarlink Semiconductor Inc. or its subsidiaries (collectively “Zarlink”) is believed to be reliable.
However, Zarlink assumes no liability for errors that may appear in this publication, or for liability otherwise arising from the application or use of any such
information, product or service or for any infringement of patents or other intellectual property rights owned by third parties which may result from such application or
use. Neither the supply of such information or purchase of product or service conveys any license, either express or implied, under patents or other intellectual
property rights owned by Zarlink or licensed from third parties by Zarlink, whatsoever. Purchasers of products are also hereby notified that the use of product in
certain ways or in combination with Zarlink, or non-Zarlink furnished goods or services may infringe patents or other intellectual property rights owned by Zarlink.
This publication is issued to provide information only and (unless agreed by Zarlink in writing) may not be used, applied or reproduced for any purpose nor form part
of any order or contract nor to be regarded as a representation relating to the products or services concerned. The products, their specifications, services and other
information appearing in this publication are subject to change by Zarlink without notice. No warranty or guarantee express or implied is made regarding the
capability, performance or suitability of any product or service. Information concerning possible methods of use is provided as a guide only and does not constitute
any guarantee that such methods of use will be satisfactory in a specific piece of equipment. It is the user’s responsibility to fully determine the performance and
suitability of any equipment using such information and to ensure that any publication or data used is up to date and has not been superseded. Manufacturing does
not necessarily include testing of all functions or parameters. These products are not suitable for use in any medical products whose failure to perform may result in
significant injury or death to the user. All products and materials are sold and services provided subject to Zarlink’s conditions of sale which are available on request.
Purchase of Zarlink’s I2C components conveys a licence under the Philips I2C Patent rights to use these components in and I2C System, provided that the system
conforms to the I2C Standard Specification as defined by Philips.
Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc.
Copyright Zarlink Semiconductor Inc. All Rights Reserved.
TECHNICAL DOCUMENTATION - NOT FOR RESALE