ARCH APF100-48S

VER : PA_1
update : 2012.05.10
LED Power
APF100 SERIES
100 Watts
KEY FEATURES
„ Fully Isolated Plastic Case with IP67 Level
„ Universal Input: 90-305 VAC or 120-430 VDC
„ Three in one dimming function
(1~10VDC & PWM Signal or resistance)
„ Bulit-in Active PFC Function
„ Free Air Convection
„ High Reliability
„ With Constant Current & Constant Voltage
„ Output Voltage and Constant Current Level can Be
Adjusted Through Internal Potential Meter
„ Isolation Class II
„ LED Power Application
„ 3-Years Product Warranty
ELECTRICAL SPECIFICATIONS
Model No.
APF100-12S
100W
Max Output Wattage (W)
Voltage
Output
Protection
Isolation
APF100-48S
APF100-54S
47-63 Hz
Current (Full load)
1.5 A max. (115 VAC) / 0.7 A max. (230 VAC) / 0.6 A max. (277 VAC)
Inrush Current (<2ms)
40 A max. (115 VAC) / 60 A max. (230 VAC)
Leakage Current
<0.75 mA max.
Power Factor
PF>0.97 (115 VAC) / PF>0.9 (230 VAC) at Full Load
Voltage (V.DC.)
12V
24V
36V
48V
54V
Constant Current Range (V.DC.)
6 ~ 12V
12 ~ 24V
18 ~ 36V
24 ~ 48V
27 ~ 54V
Voltage Accuracy
±2%
Current (Convection) (mA) max
8333
4166
2777
2083
1852
Current ADJ Range (mA)
4166 ~ 8333
2083 ~ 4166
1388 ~2777
1041 ~ 2083
926 ~ 1852
Line Regulation
±1%
Load Regulation
±1%
Minimum Load
1%
Maximum Capacitive Load
100,000 uF
50,000 uF
8,000 uF
4,000 uF
3,000 uF
Ripple & Noise (max.)
100mVp-p
100mVp-p
100mVp-p
200mVp-p
200mVp-p
Efficiency (typ.)
89%
91.5%
91.5%
91.5%
91.5%
Hold-up Time
25 ms min.
Switching Frequency
100 kHz
Over Power Protection
Auto recovery
Over Voltage Protection
Auto recovery
Overt Temperature Protection
Auto recovery
Short Circuit Protection
Auto recovery
Input-Output (V.AC)
3750V
Input-FG
(V.AC)
1880V
Output-FG
.(V.AC)
Operating Temperature
Environment
APF100-36S
90-305 VAC or 120-430 VDC
Frequency (Hz)
Input
APF100-24S
500V
-30°C…+70°C (with derating)
Storage Temperature
-40°C…+85°C
Temperature Coefficient
±0.02%/°C ( 0~50°C )
Humidity
95% RH
MTBF
>100,000 h @ 25°C (MIL-HDBK-217F)
Vibration
10~500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes.
1. All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
2. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-
VER : PA_1
update : 2012.05.10
LED Power
APF100 SERIES
100 Watts
Model No.
APF100-12S
APF100-24S
APF100-36S
APF100-48S
6.44 x 2.79 x 1.50 Inches (163.7 x 71.0 x 38.0 mm ) Tolerance ±0.5 mm
Dimension (L x W x H)
Physical
Safety
g
Weight
Cooling Method
Free air convection
Agency Approvals
EN61347-1:2008、 EN61347-2-13:2006
EMI
EN 55015
(Pending)
EMS (Noise Immunity)
EN 61547
(Pending)
Surge
2KV L-L, 4KV L-E
(Conducted & Radiated Emission)
EMC
APF100-54S
(Pending)
1. All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
2. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
MECHANICAL DIMENSION
( Top View )
DERATING
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
BLOCK DIAGRAM
-2-