ARCH QLF100-24S

VER : PA_0
update : 2012.03.09
LED Power
QLF100 SERIES
100 Watts
KEY FEATURES
„
„
„
„
„
„
„
„
„
IP66/67 Design for Indoor or LED Outdoor Installations
Suitable for Dry / Damp / Wet / Locations
Universal Input: 100-277 VAC
Bulit-in Active PFC Function
High Efficiency up to 90%
Free Air Convection
High Reliability
With Constant Current & Constant Voltage
Output Voltage and Constant Current Level can Be
Adjusted Through Internal Potential Meter
„ LED Power Application
„ 3-Years Product Warranty
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
Max output wattage
(W)
Voltage
(Note2)
Frequency (Hz)
Input
Output
Protection
Isolation
Physical
QLF100-36S
QLF100-54S
96W
96W
95.58W
90-295 VAC
50 / 60 Hz
Power factor
PF>0.9 at Full load (115 VAC / 230 VAC)
Current (Full load)
1.4A max. (115 VAC) / 0.7A max. (230 VAC)
Inrush current
60 A max. (Cold Start at 230 VAC)
Leakage Current
< 0.7 mA max at 240 VAC
Voltage (V.DC.)
24V
36V
54V
Voltage ADJ Range Setup
22 ~ 27V
33 ~ 40V
49 ~ 58V
Constant Current Operation Voltage (max)
(CC Mode) (Note3)
15.6~ 24
VDC
23.4~36
VDC
35.1~54
VDC
Voltage Tolerance
±10%
Preset Current (mA) (CC Mode)
Current Adjustment Range (mA)
(CC Mode)
Minimum Load (mA)
3850
2450
1750
2600~4000
1720~2650
1150~1770
2600
1720
1150
Line Regulation (100-277VAC) (typ.)
±4%
Load Regulation (Min-Max) (typ.)
±5%
Ripple & Noise (max)
2.7Vp-p
3.6Vp-p
5Vp-p
90%
90%
Efficiency (at 230VAC.)(typ)
89%
Over current protection
Auto recovery
Over voltage protection
Zener diode clamp
Short circuit protection
Auto recovery
Input-Output (V.AC)
3750V
Input-FG
(V.AC)
1880V
Output-FG
.(V.AC)
500V
Operating temperature
Environment
QLF100-24S
-30°C…+70°C (with derating)
Storage temperature
-40°C…+85°C
Temperature coefficient
0.02%/°C
Humidity
95% RH
MTBF
>530,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
6.44 x 2.79 x 1.50 Inches
Weight
(163.7 x 71.0 x 38.0 mm ) Tolerance ±0.5 mm
g
Cooling method
Free air convection
Safety
Agency Approvals
UL8750、IEC / EN 61347-2-13、 IEC / EN 61347-1
EN 55015
(Pending)
EMC
EMI
(Conducted & Radiated Emission)
EMS (Noise Immunity)
EN 61547
(Pending)
Harmonic Current
EN 61000-3-2(at Full Load)、EN 61000-3-3
Surge
2KV L-L, 4KV L-E
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
(Pending)
(Pending)
-1-
VER : PA_0
update : 2012.03.09
LED Power
QLF100 SERIES
100 Watts
Note:
1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
2. Please check the derating curve for more details.
3. Input Voltage=115 or 230 VAC。This is the suitable operation region for LED related application.but please reconfirm special electrical requirements
for some specific ststem design.
MECHANICAL DIMENSION
( Top View )
ASSEMBLY INSTRUCTIONS
DERATING
*U Case T=2.5mm
Customer screws into the length of the case no higher than 0.5mm
(Namely screw length for load plate thickness plus 3.0mm
BLOCK DIAGRAM
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319