BEL 0RQB

ISOLATED DC/DC CONVERTERS
24 Vdc Input
12 Vdc /20 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Sep. 11, 2010
0RQB-T0R12x
RoHS Compliant
Rev.D
Features
•
Isolated
•
Output Over Voltage Shutdown
•
Fixed Frequency (307 kHz)
•
Over Temperature Protection
•
High Efficiency
•
SCP/OCP
•
High Power Density
•
Remote On/Off
•
Input Under Voltage Lockout
•
Basic Isolation
•
Input Over Voltage Lockout
•
Baseplate
•
Low Cost
•
Class 1, Category 2, Isolated DC/DC Converter (refer to IPC-9592)
•
UL60950-1 Recognized (UL/cUL) (Pending)
Applications
•
Networking
•
Computers and peripherals
•
Telecommunications
Description
The 0RQB-T0R12x is isolated dc/dc converter that operates from a nominal 24 Vdc source. This unit will provide
up to 240 W output power from a nominal 24 Vdc input. These units are designed to be highly efficient and low
cost. Features include remote on/off, over current protection and under-voltage lockout. This converter is
provided in an industry standard quarter brick package.
Part Selection
Output
Voltage
12 Vdc
Input Voltage
18 Vdc - 36 Vdc
Max. Output
Current
20 A
Max. Output
Power
240 W
Typical
Efficiency
94.5%
Model Number
Active High
0RQB-T0R120
Model Number
Active Low
0RQB-T0R12L
Notes: Add “G” suffix at the end of the model number to indicate Tray Packaging.
Part Number Explanation
0 R QB – T0 R 12 x
1 2
3
4
5
6 7
1---Through hole
2---RoHS 6, change “R” to “7” means RoHS 5
3---Series name, 1/4 Brick
4---Series code
5---Input range 24V wide (18-36V)
6---Output voltage (12V)
7---Suffix
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
1
ISOLATED DC/DC CONVERTERS
24 Vdc Input
12 Vdc /20 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Sep. 11, 2010
Absolute Maximum Ratings
Parameter
Continuous Input Voltage
Min
Typ
Max
Unit
Notes
-0.3
-
40
V
non-operating
-
-
50
V
100 mS maximum
-0.3
-
18
V
-
-
1500
V
Ambient Temperature
-40
-
85
°C
Storage Temperature
-55
-
125
°C
Input Transient Voltage
Remote On/Off
I/O Isolation Voltage
Note: Ratings used beyond the maximum ratings may cause a reliability degradation of the converter or may
permanently damage the device.
Input Specifications
Parameter
Operating Input Voltage
Min
18
Typ
24
Max
36
Unit
V
Input Current (full load)
-
-
15.0
A
Input Current (no load)
-
180
200
mA
Remote Off Input Current
-
5
10
mA
Input Reflected Ripple Current
(rms)
-
5
8
mA
Input Reflected Ripple Current
(pk-pk)
-
15
25
mA
-
0.05
0.1
As
Turn-on Voltage Threshold
16.0
16.8
17.5
V
Turn-off Voltage Threshold
15.5
16.5
17.0
V
2
I t Inrush Current Transient
Notes
Tested with simulated source
impedance of 10 uH, 5 Hz to 20 MHz;
use a 100 uF/100 V electrolytic
capacitor with ESR = 1 ohm max. at
200 kHz at 25 °C.
2
CAUTION: This converter is not internally fused. An input line fuse must be used in application.
Recommend a fast-acting fuse with maximum rating of 25A on system board. Refer to the fuse
manufacture’s datasheet for further information.
Notes: 1. This converter has internal C-L-C (23.5uF) filter.
2. All specifications are typical at 25 °C unless otherwise stated.
Output Specifications
Parameter
Output Voltage Set Point
Min
11.76
Typ
12
Max
12.24
Unit
V
Load Regulation
-
±20
±30
mV
Line Regulation
-
±10
±15
mV
Regulation Over Temperature
(-40deg.C-85deg.C)
-
±100
±200
mV
Ripple and Noise (pk-pk)
-
100
120
mV
Ripple and Noise (rms)
-
25
40
mV
Ripple and Noise (pk-pk)
under worst case
-
-
150
mV
Notes
Vin=24V, Io=50% load
Vin=24V, full load, 0-20MHz BW, with a
1µF ceramic capacitor and a 10uF
Tantalum cap at output.
over all operating input voltage, load
and temperature conditions.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
2
ISOLATED DC/DC CONVERTERS
24 Vdc Input
12 Vdc /20 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Sep. 11, 2010
Output Specifications (continued)
Parameter
Min
Typ
Max
Unit
Output Current Range
0
-
20
A
Output DC Current Limit
22
26
30
A
Short Circuit Surge Transient
-
-
5
As
Rise time
8
-
12
ms
25
35
mS
Enable form Vin
-
25
35
mS
Enable form ON/OFF
Overshoot at Turn on
-
0
3
%
Output Capacitance
0
-
5000
uF
Turn on Time
Notes
2
Transient Response
△V50%~75% of
Overshoot
-
300
400
mV
Max Load
Settling Time
-
120
200
uS
△V75%~50% of
Overshoot
-
300
400
mV
Max Load
Settling Time
-
120
200
uS
di/dt=0.1A/us, Vin=24Vdc, Ta=25°C,
with a 1µF ceramic capacitor and a
10uF Tantalum cap at the output.
Note: All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
General Specifications
Parameter
Min
94
Typ
94.5
Max
-
Unit
%
Switching Frequency
-
307
-
kHz
Over Temperature Protection
-
125
130
°C
Over Voltage Protection(Static)
-
14.15
14.5
V
Weight
-
75
-
g
Efficiency
FIT
362.8
-
2.30 x 1.45 x 0.50
58.42 x 36.83 x 12.70
-
Notes
Vin=24V, full load
This voltage is achieved by trimming
up output slowly
Calculated Per Bell Core SR-332
(Vin=24 V, Vo=12 V, Io=7 A,
Ta = 25°C, FIT=109/MTBF)
Dimensions
Inches (L × W × H)
Millimeters (L × W × H)
Isolation characteristics
Input to Output
-
-
1500
V
Input to Case
-
-
1500
V
Output to Case
-
-
500
V
10M
-
-
3900
Isolation Resistance
Isolation Capacitance
ohm
-
pF
Note: All specifications are typical at 25 °C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
3
ISOLATED DC/DC CONVERTERS
24 Vdc Input
12 Vdc /20 A Output
Sep. 11, 2010
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Thermal Derating Curve
Derating curve under normal input
Temperature reference points on top side
Derating curve under worse case input
Temperature reference points on bottom side
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
4
ISOLATED DC/DC CONVERTERS
24 Vdc Input
12 Vdc /20 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Sep. 11, 2010
Ripple and Noise Waveform
24Vdc input, 12Vdc/20A
Note: Ripple and noise at full load, and with a 1uF ceramic cap and a 10 uF Tantalum cap at output and Ta=25
deg C.
Transient Response Waveforms
Vout= 12V 50%-75% Load Transients
Vout= 12V 75%-50% Load Transients
Note: Transient Response at di/dt=0.1A/uS, Vin=24V, with 1uF ceramic cap and 10uF aluminum cap at output
and Ta=25 deg C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
5
ISOLATED DC/DC CONVERTERS
24 Vdc Input
12 Vdc /20 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Sep. 11, 2010
Startup & Shutdown
Rise time
Vin = 24 V, Full Load
Startup time
Startup from Vin
Ch1: Vo
Ch3: Vin
Vin = 24 V, Full Load
Startup from on/off
Ch1: Vo
Ch3: on/off
Vin = 24 V, Full Load
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
6
ISOLATED DC/DC CONVERTERS
24 Vdc Input
12 Vdc /20 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Sep. 11, 2010
Startup & Shutdown (continued)
Shutdown
Vin = 24 V, Full Load
Efficiency Data
96.00%
EFFICIENCY
94.00%
92.00%
90.00%
88.00%
18 V
24 V
86.00%
36 V
84.00%
82.00%
80.00%
2.00
5.00
10.00
15.00
20.00
OUTPUT CURRENT(A)
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
7
ISOLATED DC/DC CONVERTERS
24 Vdc Input
12 Vdc /20 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Sep. 11, 2010
Remote On/Off
Parameter
Signal Low (Unit On)
Signal High (Unit Off)
Signal Low (Unit Off)
Signal High (Unit On)
Active Low
Active High
Current Sink
Min
-0.3
Typ
-
Max
0.8
Unit
V
2.4
-
18
V
-0.3
-
0.8
V
2.4
-
18
V
0
-
1
mA
Notes
0RQB-T0R12L. The remote on/off pin
open, Unit off.
0RQB-T0R120. The remote on/off pin
open, Unit on.
Recommended remote on/off circuit for active low
Vin+
Vin+
On/off
On/off
Vin-
Vin-
Control with open collector/drain circuit
Control with photocoupler circuit
Vin+
Vin+
On/off
On/off
Vin-
Vin-
Vcc
Control with logic circuit
Permanently on
Recommended remote on/off circuit for active high
Vin+
Vin+
On/off
On/off
Vin-
Vin-
Control with open collector/drain circuit
Control with photocoupler circuit
Vin+
Vin+
On/off
On/off
Vin-
Vin-
Vcc
Control with logic circuit
Permanently on
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
8
ISOLATED DC/DC CONVERTERS
24 Vdc Input
12 Vdc /20 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Sep. 11, 2010
Output Trim Equations
Equations for calculating the trim resistor are shown below. The Trim Down resistor should be connected
between the Trim pin and Sense (-) pin. The Trim Up resistor should be connected between the Trim pin and the
Sense (+). Only one of the resistors should be used for any given application.
Minimum trim down voltage is 10.8V
Maximum trim up voltage is 13.2V.
The total voltage increased by trim and remote sense should not exceed 10% of the nominal output voltage.
Sense(+)
511
Rtrimdown =
− 10.22[kΩ ]
delta
Module
Trim
Rtrimdown
Sense(-)
Rtrimup=
(100+ delta) ⋅ Vo⋅ 5.11− 626
−10.22[kΩ]
1.225⋅ delta
Sense(+)
Rtrimup
Module
Trim
Sense(-)
Note:
delta =
(Vo _ req − Vo) ×100[%]
Vo
Vo_req=Desired (trimmed) output voltage [V]
Output voltage Vo=12.036V
2 500
R trim _u p (K ohm )
R trim _ d ow n (K o hm )
600
480
360
240
2 000
1 500
1 000
500
120
0
1 0 .8
0
1 1. 0 4
11 .2 8
1 1 .5 2
V o ,ad j (V)
1 1. 7 6
12
12
1 2 .24
12.48
12.7 2
Vo,adj (V)
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
12 .96
13 .2
9
ISOLATED DC/DC CONVERTERS
24 Vdc Input
12 Vdc /20 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Sep. 11, 2010
Remote Sense
This module has remote sense compensation feature. It can minimize the effects of resistance between
module’s output and load in system layout and facilitates accurate voltage regulation at load terminals or
other selected point.
1. The remote sense lines carries very little current and hence do not require a large cross-sectional area.
2. This module compensates for a maximum drop of 10% of the nominal output voltage.
3. If the unit is already trimmed up, the available remote sense compensation range should be
correspondingly reduced. The total voltage increased by trim and remote sense should not exceed 10%
of the nominal output voltage.
4. When using remote sense compensation, all the resistance, parasitic inductance and capacitance of the
system are incorporated within the feedback loop of this module. The can make an effect on the
module's compensation, affecting the stability and dynamic response. A 0.1uF ceramic capacitor can be
connected at the point of load to de-couple noise on the sense wires.
5. Recommend the connection of remote sense compensation as below figure. There are a resistor RS+
(100 ohm) from Vo+ to Sense+ and a resistor RS- (51 ohm)) from Vo- to Sense- inside of this module.
RS+
Vo+
Sense+
Load
RS-
Sense-
V o-
6. If not using remote sense compensation, please connect sense directly to output at module's pin, that is,
connect sense+ to Vo+ and sense- to Vo- at module's pin, the shorter the better. See below figure.
RS+
V o+
Sense+
Load
RS-
Sense-
Vo-
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
10
ISOLATED DC/DC CONVERTERS
24 Vdc Input
12 Vdc /20 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Sep. 11, 2010
Over Current Protection
To provide protection in a fault output overload condition, the module is equipped with internal current-limiting
circuitry and can endure current limiting for a few mili-seconds. If the over current condition persists beyond a few
milliseconds, the module will shut down into hiccup mode and restart once every 800mS. The module operates
normally when the output current goes into specified range. The typical average output current is 0.02A during
hiccup.
Vin = 24 V, Load in CC Mode
CH1: Output Voltage
CH3: Output Current
Expansion of on time portion
Over Voltage Protection
The output overvoltage protection consists of circuitry that monitors the voltage on the output terminals. If the
voltage on the output terminals exceeds the over voltage protection threshold the module will shutdown into latch
off mode. The overvoltage latch can be reset by either cycling the input power or toggling the on/off signal for one
second at least.
CH1: Output voltage waveform
Test setup:
Waveform:
CH2: Input voltage waveform
CH3: Output Current waveform
R=249K
Vo+
K
Trim
R
Vo-
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
11
ISOLATED DC/DC CONVERTERS
24 Vdc Input
12 Vdc /20 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Sep. 11, 2010
Over Temperature Protection
The OTP is achieved by thermistor RT and the threshold is set at 120C in non-latch mode; the hottest component
Q5 reaches 120C with 200LFM air flow correspondingly. It will restart automatically when the temperature falls
down to 100C. The protecting point will be varied a little under different conditions (air flow, ambient temperature,
input voltage, load...).
The hottest component on the top side: Q5
The thermistor on the bottom side: RT
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
12
ISOLATED DC/DC CONVERTERS
24 Vdc Input
12 Vdc /20 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Sep. 11, 2010
Input Under-voltage Lockout
Input Current
Under-voltage Lockout
Voltage Falling
V1=16V
V2=17V
Voltage Rising
V1
Input Voltage (V)
V2
Fundamental Circuit Diagram
1
8
4
3
7
Control
2
Isolated
Feedback
5
6
Choke
Capacitor
Resistor
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
13
ISOLATED DC/DC CONVERTERS
24 Vdc Input
12 Vdc /20 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Sep. 11, 2010
Safety & EMC
Safety
1. Material flammability
2. TUV Certification
3. UL Certification
UL94V-0
EN60950-1
UL60950-1
EMC
1. Surge
IEC61000-4-5
2. DC-DIP
IEC61000-4-29
3. Conductive EMI
EN55022 class A
Compliance to EN55022 class A (both q.peak and average) with the following inductive and capacitive filter
Setup:
L1
C5
Co nv er ter
Po sitiv e Input
Vin+
C1
C2
C3
C4
Co nv er ter
N e gativ e Input
Vin L1
Parameter
C6
Item
Designator
Vendor
Vendor P/N
1
C1
1uF/100V/1210
Murata
GRM32ER72A105KA01L
2
C2
1uF/100V/1210
Murata
GRM32ER72A105KA01L
3
C3
0.1uF/100V/1206
TDK
C3216X7R2A104K
4
C4
220μF/2000V, AL CAP
Nichicon
UHE2A221MHD6
5
C5
0.1uF/1000V/2220
Murata
GRM55DR73A104KW01L
6
C6
0.1uF/1000V/2220
Murata
GRM55DR73A104KW01L
7
T1
0.809mH
Pulse
P0429
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
14
ISOLATED DC/DC CONVERTERS
24 Vdc Input
12 Vdc /20 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Sep. 11, 2010
Safety & EMC (continued)
Positive:
Negative:
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
15
ISOLATED DC/DC CONVERTERS
24 Vdc Input
Sep. 11, 2010
12 Vdc /20 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Layout
Layout of components on top side
Layout of components on bottom side
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
16
ISOLATED DC/DC CONVERTERS
24 Vdc Input
12 Vdc /20 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Sep. 11, 2010
Mechanical Outline
Pin Connections
pin#
1
2
3
4
5
6
7
8
function
Vin (+)
On/Off
Vin (-)
Vout (-)
RSTRIM
RS+
Vout (+)
pin size
0.04"
0.04"
0.04"
0.06"
0.04"
0.04"
0.04"
0.06"
Note: This module is recommended and compatible with Pb-Free Wave Soldering and must be soldered
using a peak solder temperature of no more than 260 ºC for less than 5 seconds.
Note:
1) All Pins: Material - Copper Alloy;
Finish – 3 micro inches minimum Gold over 50 micro inches minimum Nickel plate.
2) Undimensioned components are shown for visual reference only.
3) All dimensions in inches (mm); Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm).
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
17
ISOLATED DC/DC CONVERTERS
24 Vdc Input
12 Vdc /20 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Sep. 11, 2010
Revision History
Date
Revision
Changes Detail
Approval
2008-07-22
PA
First release
XQ Han
2009-04-03
PB
Update mechanical drawing
XQ Han
2009-10-29
PC
Update input current, no load input current, remoted off input current,
Input reflected ripple current, turn on voltage threshold, turn off voltage
threshold, line regulation, output ripple and noise, output DC current
limit, turn on time, transient response, efficiency, efficiency curve,
switching frequency, over voltage protection and weight
XF Jiang
2010-09-11
D
1. Change fixed frequency from 500kHZ to 307kHZ.
XF Jiang
2. Change max value of remote on/off from 12V to 18V; Add input
transient voltage in absolute maximum ratings.
3. Update no load input current, remote off input current, input
reflected ripple current in input specifications.
4. Change typical value of pipple and noice(pk-pk) from 80mV to
100mV; Update load regulation, line regulation, regulation over
ambient temperature, turn on time, short circuit surge transient and
transient response; Add rise time, output DC current limit, ripple and
noise(pk-pk) under worse case in output specifications.
5. Change min value of efficiency from 93% to 94%; Update switching
frequency, over temperature protection, over voltage protection,
isolation capacitance and FIT; Add input to case isolation voltage,
output to case isolation voltage and isolation resistance in general
specifications.
6. Update TD, NR, TR, efficiency data and output trim equations; Add
startup&shutdown, remote on/off, remote sense, OCP, OVP, OTP,
UVLO, fundamental circuit diagram, safety&EMC and layout.
RoHS Compliance
Complies with the European Directive 2002/95/EC, calling for the elimination of lead and
other hazardous substances from electronic products.
©2010 Bel Fuse Inc. Specifications subject to change without notice. 091110
18
CORPORATE
FAR EAST
EUROPE
Bel Fuse Inc.
206 Van Vorst Street
Jersey City, NJ 07302
Tel 201-432-0463
Fax 201-432-9542
www.belfuse.com
Bel Fuse Ltd.
8F/ 8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel 852-2328-5515
Fax 852-2352-3706
www.belfuse.com
Bel Fuse Europe Ltd.
Preston Technology Management Centre
Marsh Lane, Suite G7, Preston
Lancashire, PR1 8UD, U.K.
Tel 44-1772-556601
Fax 44-1772-888366
www.belfuse.com