BEL XRSB

ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input,
3.3 Vdc/15 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Jul. 09, 2010
xRSB-50T03C
RoHS Compliant
Rev.B
Features
•
Isolated
•
Output Over Voltage Shutdown
•
High Efficiency
•
Output Voltage Trim
•
Fixed Frequency (600 kHz)
•
Over Temperature Protection
•
High Power Density
•
SCP/OCP
•
Input Under Voltage Lockout
•
Basic Insulation
•
Low Cost
•
Remote On/Off
•
Positive/Negative Remote Sense
•
Class 1, Category 2, Isolated DC/DC Converter (refer to IPC-9592)
•
UL60950-1 Recognized (UL/cUL) (Pending)
Applications
•
Networking
•
Computers and peripherals
•
Telecommunications
Description
The xRSB-50T03C is an isolated dc/dc converter that operates from a nominal 48 Vdc source. This unit will
provide up to 50 W of output power from a nominal 48 Vdc input. This unit is designed to be highly efficient and
low cost. Features include remote on/off, over current protection and under voltage lockout. The converter is
provided in an industry standard sixteenth brick package.
Part Selection
Output Voltage
Input Voltage
3.3 Vdc
36 Vdc - 75 Vdc
Max. Output
Current
15 A
Max. Output
Power
50 W
Typical
Efficiency
89%
Model Number
Active Low
xRSB-50T03C
Notes: Add “G” suffix at the end of the model number to indicate Tray Packaging.
Part Number Explanation
x R SB – 50 T 03 C
1 2
3
4
5 6
7
1---“x” can be “0” or “S”, “0” mean through hole mount and “S” mean surface mount
2---RoHS 6, change “R” to “7” means RoHS 5
3---Series name, 1/16 brick
4---Series code
5---Input range (36-75V)
6---Output voltage (3.3V)
7---Suffix
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
1
ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input,
3.3 Vdc/15 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Jul. 09, 2010
Absolute Maximum Ratings
Parameter
Continuous non-operating Input
Voltage
Input Transient Voltage
Remote On/Off
I/O Isolation Voltage
Min
Typ
Max
Unit
-0.3
-
80
V
-
-
100
V
-0.3
-
18
V
Notes
100mS maximum
-
-
1500
V
Ambient Temperature
-40
-
85
°C
Storage Temperature
-55
-
125
°C
Note: Ratings used beyond the maximum ratings may cause a reliability degradation of the converter or may
permanently damage the device.
Input Specifications
Parameter
Operating Input Voltage
Min
36
Typ
48
Max
75
Unit
V
Input Current (full load)
-
-
2
A
Input Current (no load)
-
70
120
mA
Remote Off Input Current
-
1
3
mA
Input Reflected Ripple Current
(rms)
-
3
7
mA
Input Reflected Ripple Current
(pk-pk)
-
20
50
mA
I t Inrush Current Transient
-
-
0.02
As
Turn-on Voltage Threshold
-
32
35
V
Turn-off Voltage Threshold
30
31
-
V
2
Notes
With simulated source impedance of
10uH, 5Hz to 20MHz; use a
100uF/100V electrolytic capacitor with
ESR=1 ohm max, at 200 kHz.
2
CAUTION: This converter is not internally fused. An input line fuse must be used in application.
Recommend a fast-acting fuse with maximum rating of 5A on system board. Refer to the fuse
manufacture’s datasheet for further information.
Notes: 1. This converter has internal L-C (1.0uH-1.0uF) filter.
2. All specifications are typical at 25 °C unless otherwise stated.
Output Specifications
Parameter
Min
Typ
Max
Unit
3.25
3.30
3.35
V
Load Regulation
-
±4
±9
mV
Line Regulation
-
±3
±8
mV
Regulation Over Temperature
(-40deg.C-85deg.C)
-
±9
±16
mV
Ripple and Noise (pk-pk)
-
55
90
mV
Ripple and Noise (rms)
-
12
25
mV
Output Ripple and Noise(Pk-Pk)
under worst case
-
-
100
mV
Output Voltage Set Point
Notes
Vin=48 V, Io=50%Load
0-20MHz BW, with a 1µF ceramic
capacitor and the minimum
external cap at output
over all operating input voltage,
load and ambient temperature
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
2
ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input,
3.3 Vdc/15 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Jul. 09, 2010
Output Specifications (continued)
Min
Typ
Max
Unit
Output Current Range
Parameter
0
-
15
A
Output DC Current Limit
19
22
26
A
Short Circuit Surge Transient
-
-
1
As
Rise Time
-
-
15
mS
-
35
70
mS
Enable form Vin
-
35
70
mS
Enable form ON/OFF
-
0
5
%
3000
-
10000
uF
Turn on Time
Overshoot at Turn on
Output Capacitance
Transient Response
△V
Overshoot
50%~75%
of Max Load Settling Time
△V
Overshoot
75%~50%
of Max Load Settling Time
Vo=
3.3 V
Notes
2
-
150
250
mV
-
120
200
uS
-
150
250
mV
-
120
200
uS
di/dt=0.1A/us, Vin=48Vdc, Ta=25°C,
with a 1µF ceramic capacitor and
the minimum external cap at output
Note: All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
General Specifications
Parameter
Min
Typ
Max
Unit
86
89
-
%
Switching Frequency
-
600
-
kHz
Over Temperature Protection
-
120
140
℃
Over Voltage Protection (Static)
-
4.29
5.28
V
Weight
-
13
-
g
Efficiency
Notes
Vin=48 V, full load.
TBD
-
Calculated Per Bell Core SR-332
(Vin=48V, Vo=3.3V, Io=80%load, Ta
9
= 25 °C, FIT=10 /MTBF)
1.30 x 0.9 x 0.38
33.02 x 22.86 x 9.60
-
0RSB-50T03C
1.30 x 0.9 x 0.36
33.02 x 22.86 x 9.24
-
SRSB-50T03C
-
-
1500
V
10M
-
-
Ohm
-
3900
-
pF
FIT
Dimensions
Inches (L × W × H)
Millimeters (L × W × H)
Dimensions
Inches (L × W × H)
Millimeters (L × W × H)
Isolation characteristics
Input to Output
Isolation Resistance
Isolation Capacitance
Note: All specifications are typical at 25 °C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
3
ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input,
3.3 Vdc/15 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Jul. 09, 2010
Efficiency Data
90.00%
EFFICIENCY
85.00%
80.00%
75.00%
36V
70.00%
48V
65.00%
75V
60.00%
55.00%
50.00%
1.5A
3.75A
7.5A
11.25A
15A
OUTPUT CURRENT(A)
Thermal Derating Curve
Maximum junction temperature of semiconductors derated to 120 degree C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
4
ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input,
3.3 Vdc/15 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Jul. 09, 2010
Thermal Derating Curve (continued)
Temperature reference points on top side
Temperature reference points on bottom side
Ripple and Noise Waveform
48 Vdc input, 3.3 Vdc/15 A output
Note: Ripple and noise at full load, and with a 1uF ceramic cap and a 3000 uF cap at output, Ta=25 deg C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
5
ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input,
3.3 Vdc/15 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Jul. 09, 2010
Transient Response Waveforms
50%-75% Load Transients at Vin=48 V
75%-50% Load Transients at Vin=48 V
Note: Transient response at di/dt=0.1A/us, with 1uF ceramic cap and 3000uF cap at output, and Ta=25 deg C.
Remote On/Off
Parameter
Signal Low (Unit On)
Signal High (Unit Off)
Active Low
Current Sink
Min
-0.3
Typ
-
Max
0.8
Unit
V
2.95
-
18
V
0
-
1
mA
Notes
The remote on/off pin open, Unit off.
Recommended remote on/off circuit for active low
Vin+
Vin+
On/off
On/off
Vin-
Vin-
Control with open collector/drain circuit
Control with photocoupler circuit
Vin+
Vin+
On/off
On/off
Vin-
Vin-
Vcc
Control with logic circuit
Permanently on
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
6
ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input,
3.3 Vdc/15 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Jul. 09, 2010
Output Trim Equations
Equations for calculating the trim resistor are shown below. The Trim Down resistor should be connected
between the Trim pin and GND pin. The Trim Up resistor should be connected between the Trim pin and the
Vout pin. Only one of the resistors should be used for any given application.
Minimum trim down voltage is 2.97V
Maximum trim up voltage is 3.63V.
The total voltage increased by trim and remote sense should not exceed 10% of the nominal output voltage.
Rtrimdown =
Vout
511
− 10.22[kΩ]
delta
Module
Trim
GND
Rtrimup =
(100 + delta ) ⋅ Vo ⋅ 5.11 − 626
− 10.22[kΩ]
1.225 ⋅ delta
Rtrimdown
Vout
Module
Rtrimup
Trim
GND
Note:
delta =
(Vo _ req − Vo ) × 100 [% ]
Vo
300
1500
270
1350
Trim resistor value,Rtrim_up(KOhm)
Trim resistor value Rtrim_down(KOhm)
Vo_req=Desired (trimmed) output voltage [V]
Output voltage Vo=3.308 V
240
210
180
150
120
90
60
1050
900
750
600
450
300
150
30
0
2.64
1200
2.71
2.77
2.84 2.9 2.97 3.04 3.1
Adjusted output voltage Vo,adj (V)
3.17
3.23
3.3
0
3.3
3.33
3.37
3.4 3.43 3.46 3.5 3.53
Adjusted output voltage Vo,adj(V)
3.56
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
3.6
3.63
7
ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input,
3.3 Vdc/15 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Jul. 09, 2010
Remote Sense
This module has remote sense compensation feature. It can minimize the effects of resistance between
module’s output and load in system layout and facilitates accurate voltage regulation at load terminals or
other selected point.
1. The remote sense lines carries very little current and hence do not require a large cross-sectional area.
2. This module compensates for a maximum drop of 10% of the nominal output voltage.
3. If the unit is already trimmed up, the available remote sense compensation range should be
correspondingly reduced. The total voltage increased by trim and remote sense should not exceed 10%
of the nominal output voltage.
4. When using remote sense compensation, all the resistance, parasitic inductance and capacitance of the
system are incorporated within the feedback loop of this module. It can make an effect on the module's
compensation, affecting the stability and dynamic response. A 0.1uF ceramic capacitor can be
connected at the point of load to de-couple noise on the sense wires.
5. Recommend the connection of remote sense compensation as below figure. There are a resistor RS+
(100 ohm) from Vo+ to Sense+ and a resistor RS- (51 ohm)) from Vo- to Sense- inside of this module.
RS+
Vo+
Sense+
Load
RS-
Sense-
V o-
6. If not using remote sense compensation, please connect sense directly to output at module's pin, that is,
connect sense+ to Vo+ and sense- to Vo- at module's pin, the shorter the better. See below figure.
RS+
V o+
Sense+
Load
RS-
Sense-
Vo-
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
8
ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input,
3.3 Vdc/15 A Output
Jul. 09, 2010
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Startup & Shutdown
Rise time
Test Condition:
48Vin, 3.3V/15A
Startup time
Startup from Vin
Startup from on/off
Ch1: Vo, Ch2: Vin
Test Condition: 48Vin, 3.3V/15A
Startup from on/off, Ch2: Vin
Test Condition: 48Vin, 3.3V/15A
Shutdown
Test Condition:
48Vin, 3.3V/15A
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
9
ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input,
3.3 Vdc/15 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Jul. 09, 2010
Over Current Protection
To provide protection in a fault output overload condition, the module is equipped with internal current-limiting
circuitry and can endure current limiting for a few mili-seconds. If the overcurrent condition persists beyond a few
milliseconds, the module will shut down into hiccup mode and restart once every 300mS. The module operates
normally when the output current goes into specified range. The typical average output current is 0.8A during
hiccup.
Expansion of on time portion of above figure
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
10
ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input,
3.3 Vdc/15 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Jul. 09, 2010
Over Voltage Protection
The output overvoltage protection consists of circuitry that monitors the voltage on the output terminals. If the
voltage on the output terminals exceeds the over voltage protection threshold, the module will shutdown into
hiccup mode and restart once every 400mS. The module operates normally when the fault is cleared.
Test setup:
Vo+
K
Trim
R
R=100ohm
Vo-
CH1: Output voltage waveform
CH2: Output Current waveform
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
11
ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input,
3.3 Vdc/15 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Jul. 09, 2010
Over Temperature Protection
The OTP is achieved by thermistor U1 and the threshold is set at 120C in non-latch mode; the hottest component
Q5 reaches 130C with 100LFM air flow correspondingly. It will restart automatically when the temperature falls
down to 100C. The protecting point will be varied a little under different conditions (air flow, ambient temperature,
input voltage, load...).
the hottest component Q5 on top view
thermistor U1 on bottom view
Under Voltage Lockout
Input Current
Under-voltage Lockout
Voltage Falling
Voltage Rising
V1
V2
Input Voltage (V)
V1=31V
V2=32V
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
12
ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input,
3.3 Vdc/15 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Jul. 09, 2010
Mechanical Outline
0RSB-50T03C
Pin Connections
pin#
1
2
3
4
function
Vin (+)
On/Off
Vin (-)
Vo (-)
pin#
5
6
7
8
function
RS (-)
Trim
RS (+)
Vo (+)
Note: This module is recommended and compatible with Pb-Free Wave Soldering and must be soldered
using a peak solder temperature of no more than 260 ºC for less than 5 seconds.
Note:
1) All Pins: Material - Copper Alloy;
Finish – 3 micro inches minimum Gold over 50 micro inches minimum Nickel plate.
2) Undimensioned components are shown for visual reference only.
3) All dimensions in inches (mm); Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm).
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
13
ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input,
3.3 Vdc/15 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Jul. 09, 2010
Mechanical Outline (continued)
SRSB-50T03C
Pin Connections
pin#
1
2
3
4
function
Vin (+)
On/Off
Vin (-)
Vo (-)
pin#
5
6
7
8
function
RS (-)
Trim
RS (+)
Vo (+)
Note: This module is recommended and compatible with Pb-Free Reflow Soldering and must be soldered
using a reflow profile with a peak temperature of no more than 260ºC for less than 5 seconds.
Note:
1) All Pins: Material - Copper Alloy;
Finish – 3 micro inches minimum Gold over 50 micro inches minimum Nickel plate.
2) Undimensioned components are shown for visual reference only.
3) All dimensions in inches (mm); Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm).
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
14
ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input, 3.3 Vdc/15 A Output
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Jul. 09, 2010
Revision History
Date
Version
Changes Detail
Approval
2010-3-23
A
First release
Jack Fan
2010-7-9
B
Update the Outline drawing of 0RSB-50T03C
JZ Wang
RoHS Compliance
Complies with the European Directive 2002/95/EC, calling for the elimination of lead and
other hazardous substances from electronic products.
©2010 Bel Fuse Inc. Specifications subject to change without notice. 070910
15
CORPORATE
FAR EAST
EUROPE
Bel Fuse Inc.
206 Van Vorst Street
Jersey City, NJ 07302
Tel 201-432-0463
Fax 201-432-9542
www.belfuse.com
Bel Fuse Ltd.
8F/ 8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel 852-2328-5515
Fax 852-2352-3706
www.belfuse.com
Bel Fuse Europe Ltd.
Preston Technology Management Centre
Marsh Lane, Suite G7, Preston
Lancashire, PR1 8UD, U.K.
Tel 44-1772-556601
Fax 44-1772-888366
www.belfuse.com