CPI VTX-6379E1

Dual – Band, CW Helix TWT Series, 1000 W, 5.85 GHz to 6.425 GHz, and 2000 W, 7.90
GHz to 8.40 GHz, Periodic-Permanent, Magnet Focused, Coaxial Input, Waveguide
Output, Forced Air Cooled.
Custom configurations are also available. These variations in the performance and
configuration include: mechanical configuration, electrical and RF connections, & dual
stage depressed collector.
Model Number
VTX-6379E1
Dual Band (C/X)
5.85 GHz – 6.425 GHz, 1 kW
7.90 GHz – 8.40 GHz, 2 kW
PPM Focusing
Coaxial Input
Waveguide Output
Any Mounting Position
Weight: 25 lbs. max
Forced-Air Cooled
Separate Equalizer provided
for C-Band
Power Output
(Min.)
5.85 – 6.425/7.9 – 8.4
1000/2000 W
Operating Parameters
Features
•
•
•
•
•
•
•
•
•
•
Frequency
(GHz)
Heater
Voltage
Heater
Surge
Current
Helix
Voltage
Collector
Voltage 1
Collector
Voltage 2
Collector
Current 1
Collector
Current 2
Parameters:
Ef
If
Ew
Eb1
Eb2
Ib1
Ib2
Units:
Maximum:
Minimum:
Typical:
Vdc
6.6
6.0
A
5
---
kVdc
15.4
13.9
kVdc
62% of Ew
58% of Ew
kVdc
32% Ew
28% Ew
mAdc
990
---
mAdc
650
---
Parameters:
Units:
Maximum:
Minimum:
Typical:
Helix
Current
Drive
Power
Iw
Pd
mAdc
22
---
mW
Adj.
---
Cathode
WarmUp Time
tk
minutes
--3
Load
VSWR
1.7:1
---
Collector
Temperature
°C
150
---
Air
Flow
Inlet Air
Temp
Ib/hr
--628
°C
52
---
The values listed above represent specified limits for the product and are subject to change. The data should be used
for basic information only. Formal, controlled specifications may be obtained from CPI for use in equipment design.
For additional information on CPI MPP products contact:
CPI MPP, Helix TWT Operation - 811 Hansen Way, Palo Alto, CA 94303-0750