CRYSTEKMICROWAVE CS-SM-MHD

M
ICROWAVE
A Division of Crystek Corporation
NOTE: Distance from end of cable
center conductor to Ref. Pl. is 0.289
NOTES:
1.0 Materials
1.1 Body, Coupling, and Clamp Nuts: Steel. Corrosion Resistant per ASTM-A582.
UNS No. S30300.
1.2 Center Conductor: Beryllium Copper per ASTM-B196. UNS C17300.
1.3 Solder Ferrule: Brass per ASTM-B16. UNS C36000.
1.4 Lock Ring: Beryllium Copper per ASTM-B197. UNS C17200.
1.5 Gasket and O-Ring: Silicone Rubber per A-A-59588.
1.6 Insulators: PTFE Fluorocarbon per ASTM-D1710.
2.0 Finishes
2.1 Center Contact and Solder Ferrule: Gold Plate per ASTM-B488 50 Microinches Min. thickness
over Electrolytic Nickel Plate per ASTM-B689 50 Microinches Min. thickness.
2.2 Body, Coupling, and Clamp Nuts: Passivated per SAE-AMS-2700.
2.3 Gasket, O-Ring, and Dielectric Bead: None.
3.0 Interface: Type SMA Plug per Crystek Interface Specification CC-SMAP
(Meets MIL-STD-348. Figure 310-1).
Page 1 of 2
CRYSTEK
CORPORATION
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
Fax: 239-561-1025 • www.crystek.com
M
ICROWAVE
A Division of Crystek Corporation
Harbour SS402 Cable
Step 1
1.1 Trim Cable as shown.
2.1
2.2
2.3
2.4
Step 2
Slide clamp nut over cable as shown.
Insert cable into solder ferrule as shown then solder braids to ferrule where indicated.
Trim exposed cable dielectric flush with solder ferrule face.
Slide dielectric stop over cable center conductor against ferrule face and solder contact
flush against stop to dimension shown.
2.5 Slide forward insulator onto contact.
NOTE: Distance from end of cable
center conductor to Ref. Pl. is 0.289
Step 3
3.1 Insert cable/contact sub-assembly into connector until seated and tighten clamp nut to
25-35 in-lbs.
Product Control:
Crystek Part Number:
CS-SM-MHD
Release Date:
04-Jan-11
Revision Level:
A
Responsible:
K. Piotrowicz
CRYSTEK
CORPORATION
Page 2 of 2
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
Fax: 239-561-1025 • www.crystek.com