rev. Designed for applications where a group of polar power supplies are isolated from the input power supply in a distributed power supply system on a circuit board. model number VIBLT1-S5-S5-SMT VIBLT1-S5-S9-SMT VIBLT1-S5-S12-SMT VIBLT1-S5-S15-SMT VIBLT1-S12-S5-SMT VIBLT1-S12-S9-SMT VIBLT1-S12-S12-SMT VIBLT1-S12-S15-SMT VIBLT1-S15-S5-SMT VIBLT1-S15-S9-SMT VIBLT1-S15-S12-SMT VIBLT1-S15-S15-SMT VIBLT1-S24-S5-SMT VIBLT1-S24-S9-SMT VIBLT1-S24-S12-SMT VIBLT1-S24-S15-SMT 1 of 3 date 07/2010 DESCRIPTION: DC-DC CONVERTER PART NUMBER: VIBLT1-SMT description page features · SMD package ·temperature range: -40°C~+85°C ·1K Vdc isolation ·internal SMD construction ·short circuit protection ·industry standard pinout ·no heatsink required ·no external component required ·RoHS compliant input voltage nominal range 5 Vdc 4.75~5.25 Vdc 5 Vdc 4.75~5.25 Vdc 5 Vdc 4.75~5.25 Vdc 5 Vdc 4.75~5.25 Vdc 12 Vdc 11.4~12.6 Vdc 12 Vdc 11.4~12.6 Vdc 12 Vdc 11.4~12.6 Vdc 12 Vdc 11.4~12.6 Vdc 15 Vdc 12.8~15.2 Vdc 15 Vdc 12.8~15.2 Vdc 15 Vdc 12.8~15.2 Vdc 15 Vdc 12.8~15.2 Vdc 24 Vdc 22.8~25.2 Vdc 24 Vdc 22.8~25.2 Vdc 24 Vdc 22.8~25.2 Vdc 24 Vdc 22.8~25.2 Vdc output voltage 5 Vdc 9 Vdc 12 Vdc 15 Vdc 5 Vdc 9 Vdc 12 Vdc 15 Vdc 5 Vdc 9 Vdc 12 Vdc 15 Vdc 5 Vdc 9 Vdc 12 Vdc 15 Vdc output current max. min. 150 mA 15 mA 111 mA 12 mA 83 mA 9 mA 67 mA 7 mA 150 mA 15 mA 111 mA 12 mA 83 mA 9 mA 67 mA 7 mA 150 mA 15 mA 111 mA 12 mA 83 mA 9 mA 67 mA 7 mA 150 mA 15 mA 111 mA 12 mA 83 mA 9 mA 67 mA 7 mA efficiency (typ) 69% 70% 71% 72% 69% 70% 71% 72% 69% 70% 71% 72% 69% 70% 71% 72% OUTPUT SPECIFICATIONS item output power line regulation load regulation output voltage accuracy temperature drift output ripple output noise switching frequency test conditions for Vin change of 5% 10% to 100% full load @ full load @ 100% load 20 MHz bandwidth 20 MHz bandwidth full load, nominal input min. 0.1 typ. 10 50 100 max. 1 ±0.3 1 ±3 0.03 20 100 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 units W % % % %/°C mVp-p mVp-p KHz www.v-infinity.com rev. page 2 of 3 date 07/2010 DESCRIPTION: DC-DC CONVERTER PART NUMBER: VIBLT1-SMT GENERAL SPECIFICATIONS short circuit protection temperature rise at full load cooling operating temperature range storage temperature range lead temperature range storage humidity range case material MTBF weight continuous 260°C Max, 1.5mm from case for 10 seconds free air convection -40°C to +85°C -55°C to +125°C +15°C to +25°C <95% plastic (UL94-V0) >3,500,000 hrs. 2.8 g ISOLATION SPECIFICATIONS item isolation voltage insulation resistance test conditions tested for 1 min. test at 500 Vdc min. 1000 1000 typ. max units Vdc M Ω NOTE: 1. All specifications measured at TA=25°C, humidity <75%, nominal input voltage and rated output load unless otherwise specified. DIMENSIONS mm(inches) RECOMMENDED FOOTPRINT Single Output (Sid e Vie w ) 5.75 [0.226] 6.00 [0.236] 10 9 8 (To p Vie w ) 1 2 3 5 0.60 [0.024] 6 7 12.70 [0.500] 14 13 12 17.78 [0.700] 15.24 [0.600] 16.70 [0.657] 17.78 [0.700] 14 13 12 10 9 8 2.54 [0.100] 1 2 3 5 6 7 2.10 [0.083] 1.00 [0.039] 2.54 [0.100] 2.54 [0.100] A 12.22 [0.481] 0.25 [0.010] A 5 max 1.30 [0.051] Note: Unit: mm[inch] Pin section tolerances: 0.10mm[ 0.004inch] General tolerances: 0.25mm[ 0.010inch] FOOTP R I N T D ETAI LS Pin Func t ion 1 2 6 7 Ot hers GN D Vin 0V + Vo NC N C : N o C onnec t ion 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 www.v-infinity.com rev. PART NUMBER: VIBLT1-SMT INPUT FILTERING page 3 of 3 date 07/2010 DESCRIPTION: DC-DC CONVERTER TYPICAL CHARACTERISTICS If you want to further decrease the input/output ripple, an “LC” filtering network may be connected to the input and output ends of the DC/DC converter as shown in Figure 1. The inductance and frequency of the “LC” filtering network should be staggered with the DC/DC frequency to avoid mutual interference. However, the capacitance of the output filter capacitor must be proper. If the capacitance is too big, a startup RECOMMENDED REFLOW SOLDERING PROFILE problem might arise. For every channel of output, provided the safe and reliable operation is ensured, the greatest capacitance of its filter capacitor sees. To ensure this module can operate efficiently and reliably during operation, the minimum output load is not less than 10% of the full load and the product should never be operated under no load. If the actual output power is very small, please connect a resistor with proper resistance at the output end in parallel to increase the load. It’s not recommended to connect any external capacitor in the application field with less than 0.5 watt output. 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 www.v-infinity.com