EMERSON-NETWORKPOWER NXI110

Embedded Power for
Business-Critical Continuity
Rev.03.23.07
nxi110
1 of 4
NXI110 Series
Single output,
5 Bit Selectable
(Non-Isolated)
Total Power:
110W
Input Voltage: 11 - 13.2VDC
# of Outputs: Single
Special Features
• Meets VRM9.0 specification
High efficiency: 84% typical @
Vin = 12 V, Vout = 1.7 V,
Iout = 60 A
• Multi-phase power conversion
• Microprocessor voltage
identification input
• 5 Bit VID input
• - 1.10 Vdc to 1.85 Vdc in
25 mV steps
• Remote enable pin
• Power good signal
• True double ended differential
remote sense
• Democratic current sharing,
no need for master/slave
configuration
• Up to 50 A/μsec load transient
no load to full load, recovery
within 50 μsec
• Overcurrent and short circuit
protection
• Overvoltage protection with on
board fuse
• Vertical plug-in to standard
motherboard connector
• No minimum load requirement
• Available RoHS compliant
• 2 year warranty
The NXI110 non-isolated dc-dc converters are designed to meet
the exceptionally fast transient response requirements of today’s
microprocessors and fast switching logic in a compact size at a
very affordable price. Advanced Circuit techniques, component
selection and placement optimization, state-of-the-art thermal
packaging, and Surface Mount Technologies provide a high power
density, highly reliable, and very precise voltage regulation system
for advanced microprocessors. Multi-phase power conversion
techniques allow the NXI converters to lead the industry with
regard to conversion efficiency without adding unneccesary
complexity. VRM9.0 specification compliant without the need for
expensive external components. On board active current sharing
circuit guarantees the current sharing specification is met both
during both static and dynamic load conditions
Embedded Power for
Business-Critical Continuity
Rev.03.23.07
nxi110
2 of 4
Specifications
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
OUTPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Voltage adjustability
See table
Set point accuracy
Vout
Ripple and noise
(See Note 1)
20 MHz bandwidth
Transient response
peak dev. settling time
(See Note 2)
Short-circuit protection
1V7, 1V85 output @ 60 A
1V10 output @ 60 A
Switching frequency
Fixed (See Note 3)
Standards
94V-0 Flammability rating
±0.8%
15 mV pk-pk
125 mV
50 μs
Continuous
automatic recovery
INPUT SPECIFICATIONS
Weight
MTBF
84%
76%
900 kHz
75 g (2.64 oz)
Bellcore TR-332
Mating connector
2,000,000 hours
(See Note 4)
ENVIRONMENTAL SPECIFICATIONS
Input voltage range
12 Vin nominal
Input current
No load
Remote OFF
UVLO turn ON voltage
UVLO turn OFF voltage
Start-up time
Efficiency
11.0-13.2 Vdc
300 mA
40 mA max.
10.8 V typ.
9.5 V typ.
Nominal line
Active high remote ON/OFF
Logic compatibility
ON
Open-circuit voltage
OFF
Maximum temperature
shock
Operating
Temperature shock
Operating
Non-operating
Humidity
Operating
Storage
85% RH
95% RH
Altitude
Operating
Storage
10,000 feet max.
50,000 feet max.
Shock
Operational and
non-operational
50 G 11 ms
half sine wave
Vibration
(See Note 5)
Operational and
non-operational
0.02 G2/Hz max.
Electrostatic discharge
Operating (See Note 6)
Non-operating
Thermal performance
(See Note 7)
Operating ambient
temperature
10 ms
Ref. to -input
5.0 Vdc
0.8 Vdc max.
5 ˚C/10 min.
10 ˚C/hour
20 ˚C/hour
ESD 15 kV
ESD 25 kV
0 to +60 °C
Embedded Power for
Business-Critical Continuity
Rev.03.23.07
nxi110
3 of 4
Specifications Contd.
INPUT
VOLTAGE
NOMINAL OUTPUT
VOLTAGE
NOMINAL OUTPUT
CURRENT
TYPICAL
EFFICIENCY
MODEL
NUMBER (8,9)
12 Vdc
See Table 2
60 A
84%
NXI110-12P1V8CY
Notes
1
2
3
4
5
15 mV pk-pk ripple with no external output filtering.
Vin = 12 V, Vout = 1.6 V, Iout = 60 A.
125 mV peak deviation when slewing load from no load to full load at 50
A/μsec. Oscon type low impedance caps required across output.
Each phase operates at a fixed 225 kHz. Effective fundamental output
frequency is 900 kHz / 4 phases each at 225 kHz interleaved.
Recommended mating connector is AMP 1364125-1 or equivalent.
From 5 Hz to 20 Hz, maintaining 0.02 G2/Hz from 20 Hz to 500 Hz, all axes.
6
7
8
9
Initilization level; ESD event shall cause no out-of-regulation conditions.
Requires 400 LFM forced air over the converter. Ensure the thermal reference
point (see figure 2) is kept below 95 ºC to maintain the reliability of the
converter.
The ‘Y’ suffix indicates that these parts are TSE RoHS 5/6 (non Pb-free)
compliant.
NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
TABLE 1: PIN CONNECTIONS
PIN NO. FUNCTION
TABLE 2 : VOLTAGE IDENTIFICATION (VID) CODES
PIN NO. FUNCTION
VID4
VID3
VID2
VID1
VID0
1
Vin+
32
Vo-
1
1
1
1
1
VDAC
Off
2
Vin+
33
Vo+
1
1
1
1
0
1.100
3
Vin+
34
Vo-
1
1
1
0
1
1.125
4
Vin+
35
Vo+
1
1
1
0
0
1.150
5
Reserved
36
Vo-
1
1
0
1
1
1.175
6
Key
37
Vo+
1
1
0
1
0
1.200
1
0
0
1
1.225
7
VID3
38
Vo-
1
8
VID1
39
Vo+
1
1
0
0
0
1.250
Vo-
1
0
1
1
1
1.275
1
0
1
1
0
1.300
1
0
1
0
1
1.325
1
0
1
0
0
1.350
1
0
0
1
1
1.375
1
0
0
1
0
1.400
1
0
0
0
1
1.425
1
0
0
0
0
1.450
0
1
1
1
1
1.475
0
1
1
1
0
1.500
9
Reserved
40
10
PWRGD
41
Vo+
11
Vo sen-
42
Vo-
12
Reserved
43
Vo+
13
Vo-
44
Vo-
14
Vo+
45
Vo+
15
Vo-
46
Vo-
16
Vo+
47
Vo+
17
Vo-
48
Vo-
18
Vo+
49
Vo+
0
1
1
0
1
1.525
19
Vo-
50
Vo+
0
1
1
0
0
1.550
20
Vo+
51
Reserved
0
1
0
1
1
1.575
21
Vo-
52
Vo sen+
0
1
0
1
0
1.600
22
Vo+
53
OUTEN
0
1
0
0
1
1.625
23
Vo-
54
Ishare
0
1
0
0
0
1.650
24
Vo+
55
VID0
0
0
1
1
1
1.675
0
1
1
0
1.700
25
Vo-
56
VID2
0
26
Vo+
57
VID4
0
0
1
0
1
1.725
0
1
0
0
1.750
27
Vo-
58
VRM-pres
0
28
Vo+
59
Vin-
0
0
0
1
1
1.775
Vin-
0
0
0
1
0
1.800
0
0
0
0
1
1.825
0
0
0
0
0
1.850
29
Vo-
60
30
Vo+
61
Vin-
31
Vo-
62
Vin-
Embedded Power for
Business-Critical Continuity
Rev.03.23.07
nxi110
4 of 4
Mechanical Notes
All dimensions in INCHES (mm).
Americas
3.800 (96.520)
3.600 (91.440)
0.563 (14.300) MAX
0.425 (10.795)
0.425 (10.795)
0.100 (2.540) TYP
COMP CLEAR
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
0.54 (13.72)
Europe (UK)
0.425 (10.795)
2.300 (58.420)
1.075 (27.305)
2.615
(66.421)
REF
1
62
6 No Contact
1
KEEP OUT
AREA
0.310 (7.874)
11
12
31
32
32-62 1-31
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
0.300 (7.620)
0.610 (15.494)
1.122
(28.499)
REF
0.042
(1.067)
KEY
0.093 (2.362)
3.000 (76.200)
0.307 (7.798)
3.186 (80.924)
Asia (HK)
0.250 (6.350) MAX
0.063 (1.600) THK FR-4 DBL-SIDED
CIRCUIT BOARD W/GOLD-PLATED
(30u") CONNECTOR FINGERS
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
DIMENSIONS IN INCHES (MM)
For global contact, visit:
Figure 1: Mechanical Drawing
www.powerconversion.com
[email protected]
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
TRP
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Figure 2:
Thermal Reference Point (TRP) Monitor Tab Indicated
Site Monitoring and Services
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.