EMERSON-NETWORKPOWER BXA3

Embedded Power for
Business-Critical Continuity
Rev.03.07.07
bxa3
1 of 4
BXA3 Series
Single output
Total Power:
5W
Input Voltage: 38 - 72VDC
# of Outputs: Single
Special Features
• 3 Watts in DIL Package
• 9 models including 3.3 Vdc
output
• Wide input ranges 9 Vdc to 18
Vdc, 18 Vdc to 36 Vdc, 36 Vdc
to 75 Vdc
• EN55022 conducted emissions
level A (optional)
• Continuous short circuit
protection
• Operating temperature
range -25 °C to +105 °C
• Input voltage range to
ETS300-132-2
• UL, VDE and CSA safety
approvals
• Available RoHS compliant
• 2 year warranty
Safety
VDE0805/EN60950/IEC950
File No. 10401-3336-0098
Licence No. 5856
UL1950 File No. E136005
CSA C22.2 No. 950
File No. LR41062C
The BXA3 Series of dc-dc converters is designed to offer the
optimum cost/benefit power solution for a wide variety of
applications including public and private telecommunications,
industrial systems and process and test equipment. The series
consists of 9 models with input voltages of 9 Vdc to 18Vdc, 18 Vdc
to 36 Vdc and 36 Vdc to 75 Vdc, and offers standard output
voltages of 3.3 V, 5 V, 12 V and 15 V in single and dual output
configurations. Continuous short-circuit protection, overvoltage
protection, 60 mV output ripple and EN55022 level A conducted
noise compliance minimize design-in time, cost and eliminate the
need for external components.
Embedded Power for
Business-Critical Continuity
Rev.03.07.07
bxa3
2 of 4
Specifications
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Voltage accuracy
±1.0%
Line regulation
LL to HL, all outputs
±2.5%
Load regulation
Full load to no load
±2.5%
Ripple and noise
(5 Hz to 20 MHz)
+5 V output
All others
60 mV pk-pk, max.,
15 mV rms
100 mV pk-pk, max.,
15 mV rms
Temperature coefficient
Over voltage protection
±0.02%/°C, max.
Clamp diode
Short circuit protection
135% Vout
Continuous
automatic recovery
INPUT SPECIFICATIONS
Input voltage range
12 Vdc
24 Vdc
48 Vdc
Input filter
Suffix ‘-F’ (See Note 5)
Reverse voltage
protection
(See Note 7)
Max. input rise
and fall time
Output remains within
specification
9-18 Vdc
18-36 Vdc
36-75 Vdc
Pi type
Yes
Conducted emissions
EN55022, FCC part 15
Suffix ‘-F’ versions
(See Notes 5 and 6)
Level A
GENERAL SPECIFICATIONS
Efficiency
See table
Isolation voltage
Input/output
Switching frequency
Variable
Approvals and
standards
500 Vdc
200 kHz to1 MHz
VDE0805, EN60950, IEC950
UL1950, CSA C22.2 No. 950
Case material
Non-conductive
black plastic
Material flammability
UL94V-0 min.
Weight
15 g (0.53 oz)
MTBF
MIL-HDBK-217F
800,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
5 V/ms
Operating ambient
(See derating curve)
Non-operating amb
Cooling
-25 °C to +105 °C
-40 °C to +105 °C
Free air convection
cooled
Relative humidity
Non-condensing
5% to 95% RH
Altitude
Operating
Non operating
10,000 feet max.
40,000 feet max.
Vibration
5 Hz to 500 Hz
2.5 G rms (approx.)
Embedded Power for
Business-Critical Continuity
Rev.03.07.07
bxa3
3 of 4
Specifications Contd.
INPUT
OUTPUT
OUTPUT
INPUT
VOLTAGE
VOLTAGE
CURRENT
9-18 Vdc
3.3 V
600 mA
245 mA
68%
±2.5%
±2.5%
BXA3-12S3V3J
9-18 Vdc
15 V
200 mA
335 mA
75%
±2.5%
±2.5%
BXA3-12S15J
18-36 Vdc
3.3 V
600 mA
122 mA
68%
±2.5%
±2.5%
BXA3-24S3V3J
18-36 Vdc
5V
500 mA
140 mA
76%
±2.5%
±2.5%
BXA3-24S05J
18-36 Vdc
±5 V
±250 mA
140 mA
76%
±2.5%
±2.5%
BXA3-24D05J
36-75 Vdc
3.3 V
600 mA
61 mA
68%
±2.5%
±2.5%
BXA3-48S3V3J
36-75 Vdc
5V
500 mA
69 mA
76%
±2.5%
±2.5%
BXA3-48S05J
36-75 Vdc
12 V
250 mA
83 mA
76%
±2.5%
±2.5%
BXA3-48S12J
36-75 Vdc
15 V
200 mA
83 mA
76%
±2.5%
±2.5%
BXA3-48S15J
(1)
CURRENT
TYPICAL
(2)
Notes
1
2
3
4
5
6
7
8
9
Maximum.
Maximum figure at full load (nominal).
Low line to high line.
Full load to no load.
An optional internal filter is available. When the filter is added, the BXA3
will meet VDE0871-A, VDE0878-A and EN55022-A. Add the suffix ‘-F’ to
the model number, e.g. BXA3-12S15-FJ.
Conducted noise filtering to EN55022 level B may be accomplished by
putting the following capacitors across the input pins.
12 Vdc
5 μF ceramic X7R dielectric type
24 Vdc
3 μF ceramic X7R dielectric type
48 Vdc
1 μF ceramic X7R dielectric type
Reverse voltage protection can be implemented by putting a fast blow fuse
on the positive input rail. Rate the fuse for 250 mA at 48 Vdc input, 500 mA
at 24 Vdc input and 1000 mA at 12 Vdc input.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special
request, please contact your local sales representative for details.
NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
EFFICIENCY
REGULATION
LINE
(3)
LOAD
MODEL
(4)
NUMBER (5,8,9)
Embedded Power for
Business-Critical Continuity
Rev.03.07.07
bxa3
4 of 4
Americas
0.12 Typ
(3.0)
0.1
(2.5)
23
2
22
3
DOT ON TOP
REFERENCES
PIN 2
0.020 Dia.
(0.5)
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
1.25
(31.8)
0.6
(15.2)
0.1
(2.5)
0.1
(2.5)
0.175
(4.5)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
BOTTOM VIEW
16
9
15
10
14
11
0.03
(0.762)
Asia (HK)
0.02
(0.5)
0.60
(15.2)
0.1
(2.5)
0.50
(12.7)
0.80
(20.3)
ALL DIMENSIONS IN Inches (mm)
ALL PINS ARE IN TRUE POSITION WITHIN .010 DIA. @ M.M.C.
TOLERANCE
.XX = ± 0.02
(INCHES)
.XXX = ± 0.005
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
PIN CONNECTIONS
[email protected]
PIN NUMBER
SINGLE OUTPUT
DUAL OUTPUT
2
–Vin
–Vin
3
–Vin
–Vin
22
+Vin
+Vin
23
+Vin
+Vin
9
No Pin
Common
10
No Pin
No Pin
11
No Connection
-Vout
14
+Vout
+Vout
15
No Pin
No Pin
16
-Vout
Common
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
DERATING CURVE
Output Power (Watts)
Integrated Cabinet Solutions
Outside Plant
71°C
2.5/3W
Precision Cooling
Site Monitoring and Services
85°C
EmersonNetworkPower. com
105°C
0W
-25°C -20°C -10°C
0°C 10°C
20°C
30°C 40°C
50°C
60°C 70°C 80°C
90°C 100°C 110°C
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.