FCI FBR6050

60 Amp High Voltage
SCHOTTKY BARRIER
RECTIFIERS
FBR6030 . . . 6060 Series
Data Sheet
Mechanical Dimensions
Description
.900
.200
2 plcs.
.670
.75
.175
JEDEC
T0-3P
.200
.050 Typ
Features
n HIGH CURRENT CAPABILITY
WITH LOW VF
n HIGH SURGE VOLTAGE AND
TRANSIENT PROTECTION
n HIGH EFFICIENCY w/LOW POWER LOSS
n MEETS UL SPECIFICATION 94V-0
Electrical Characteristics @ 25o C.
Units
FBR6030 . . . 6060 Series
FBR6030 FBR6035 FBR6040 FBR6045 FBR6050 FBR6060
Maximum Ratings
Peak Repetitive Reverse Voltage...VRRM
30
35
40
45
50
60
Volts
Working Peak Reverse Voltage...VRWM
30
35
40
45
50
60
Volts
DC Blocking Voltage...VDC
30
35
40
45
50
60
Volts
RMS Reverse Voltage...VR(rms)
21
24
28
31
35
42
Volts
Average Forward Rectified Current...IO
@ TC = 110°C VR (equiv.) < = 0.2VR(DC)
............................................. 6 0 ...............................................
Amps
Non-Repetitive Peak Forward Surge Current...IFSM
@ Rated Load Conditions, ½ Sine Wave, Single Phase, 60HZ
............................................. 6 0 0 ...............................................
Amps
Forward Voltage...VF
@ IF = 30 Amps
< ........................ .65 ........................ >
Volts
DC Reverse Current...IR
@ Rated DC Blocking Voltage
T C = 25°C
T C =125°C
Operating & Storage Temperature Range...TJ, TSTRG
Page 7-44
< ........ .75 ......... >
............................................. 1 0 ............................................... mAmps
< ........................ 1 0 0 ........................ >
< .......... 1 5 0 ........ > mAmps
............................................. -65 to 150 ......................................
°C
Typical Reverse Characteristics
FBR6030...6045
FBR6030...6045
Case Temperature (oC)
Reverse Voltage (Volts)
Typical Reverse Characteristics
pF
Reverse Voltage (Volts)
Reverse Voltage (Volts)
Typical Forward Characteristics
Common Cathode,
Suffix "C"
FBR6050...6060
2
Case
Amps
1
FBR6050...6060
Reverse Current (mA)
Typical Junction Capacitance
FBR6030...6045
Peak Forward Surge Current
Ratings at
25 Deg. C ambient
temperature
unless otherwise
specified.
Amps
Amps
FBR6050...6060
Reverse Current (mA)
Forward Current Derating Curve
FBR6030 . . . 6060 Series
60 Amp High Voltage
SCHOTTKY BARRIER
RECTIFIERS
Data Sheet
3
Single Phase Half
Wave, 60 HZ
Resistive or
Inductive Load.
Forward Voltage (Volts)
NOTES: 1. Measured @ 1 MHZ and applied reverse voltage of 4.0V.
2. Thermal Resistance Junction to Case, Jedec Method.
3. When Mounted to heat sink, from body.
Number of Cycles @ 60 Hz
For Capacitive
Load, Derate
Current by 20%.
Page 7-45