FCI FBR2060

20 Amp High Voltage
SCHOTTKY BARRIER
RECTIFIERS
FBR2060 . . . 20100 Series
Data Sheet
Mechanical Dimensions
Description
Case
1
JEDEC
T0-220AB
2
CASE
3
Common Cathode Suffix ‘‘C’’
1
1
2
3
3
2
CASE
Common Anode Suffix ‘‘A’’
Features
n HIGH CURRENT CAPABILITY
WITH LOW VF
n HIGH SURGE VOLTAGE AND
TRANSIENT PROTECTION
n HIGH EFFICIENCY w/LOW POWER LOSS
n MEETS UL SPECIFICATION 94V-0
FBR2060 . . . 20100 Series
Maximum Ratings
FBR2060
FBR2080
FBR2090
FBR20100
Peak Repetitive Reverse Voltage...VRRM
Pulse Test 0.5 ms, Duty Cycle 1/40
60
80
90
100
Working Peak Reverse Voltage...VRWM
60
80
90
100
DC Blocking Voltage...VDC
60
80
90
100
Units
Volts
Volts
Volts
Average Forward Rectified Current...Io
TC = 110°C
............................................. 2 0 ...............................................
Amps
Non-Repetitive Peak Forward Surge Current...IFSM
@ Rated Load Conditions, Sinosoidal Wave,
60Hz, 1 Cycle, TJ = 125°C
............................................. 120 ...............................................
Amps
Operating Temperature Range...TJ
......................................... -40 to 125 ..........................................
°C
Storage Temperature Range...TSTRG
.........................................
°C
+ 125
..........................................
Electrical Characteristics
Maximum Forward Voltage...VF
@ IF = 10 Amps
@ IF = 20 Amps
............................................. .85 ...............................................
............................................. .95 ...............................................
Volts
Volts
Maximum DC Reverse Current (@ VR = VRM)...IR
@ Rated DC Blocking Voltage
............................................. 3.0 ............................................... mAmps
Thermal Resistance, Junction to Case...RθJC
............................................. 1.5 ...............................................
°C / W
20 Amp High Voltage
SCHOTTKY BARRIER
RECTIFIERS
Typical Reverse Characteristics
Reverse Current (mA)
Average Forward Current (A)
Forward Current Derating Curve
Case Temperature (oC)
Reverse Voltage (V)
Typical Forward Characteristics
Forward Current (A)
Peak Forward Surge Current (A)
Maximum Surge Capacity
FBR2060. . . 20100 Series
Data Sheet
Number of cycles @ 60 Hz
Forward Voltage (V)
Ratings at
25 Deg. C ambient
temperature
unless otherwise
specified.
Single Phase Half
Wave, 60 Hz
Resistive or
Inductive Load.
For Capacitive
Load, Derate
Current by 20%.