DELTA MPT1015

DELTA P/N : MPT1015-H1 Series
Mechanical dimensions
Unit : mm
A’
10.85 ± 0.35
A
10 ± 0.3
B
1.3 ± 0.2
C
2.0 ± 0.5
C’
2.5 ± 0.1
D
3.0 ± 0.5
D’
5.0 ± 0.2
E
0~0.15
F
4.1
G
5.4
H
13.6
Electrical Characteristics
DCR
Lo @0A
Part No.
(uH)
Ir(Adc)
± 20%
MPT1015-R68H1
MPT1015-R82H1
MPT1015-1R0H1
MPT1015-3R3H1
MPT1015-4R7H1
0.68
0.82
1.0
3.3
4.7
(mΩ)
Isat(Adc)
7.5
6.0
5.5
4.0
3.0
16.0
14.0
12.0
6.5
6.0
TYP.
MAX
15.0
16.0
18.0
62.0
83.0
16.0
18.0
21.0
70.0
95.0
NOTES:
(1) All test data is referenced to 25℃ ambient.
(2) Ir is the DC current which cause the surface temperature of the part increse approximate 40℃
(3) Isat is the DC current which cause the inductance drop approximate 30% of Lo.
(4) Operating temperature range -55℃ to 125℃. (The part temperature should be keepped under 125℃
when the worse operating condition apply on it. Circuit design, component placement,
PWB tracesize and thickness, airflow and other cooling provision may affect the part temperature.
Part temperature should be verified in the end application.)
(5)
The rated current is depended on Ir and Isat which one is lower.