KYL KYL-500S

zhen KYL Communication Equipment Co
., Ltd
Shen
Shenz
Co.
KYL-500
S Smart Wi
500S
Wirreless
le
Tran
anssceiver Data Modu
Module
Shenzhen KYL Communication Equipment Co., Ltd
Address: C3705-3707, Huangdu Square, South of Exhibition Center, Yitian Road, Futian
District, Shenzhen, Guangdong, China 518048
Tel: 86-755-82943662
Fax: 86-755-83408785
Skype
Skype:KYL-Sunny
Yahoo messenger: [email protected]
MSN: [email protected]
Email: [email protected]
Website: http://www.rf-data.com
Web: www.rf-data.com
Email: [email protected]
Fax: 86-755-73408785
zhen KYL Communication Equipment Co
., Ltd
Shen
Shenz
Co.
Before using the product please read the use manual carefully. Any
question in technical, you can contact us.
out KYL-500
S
I: Ab
Abo
500S
KYL-500S, the micro power wireless transceiver data module is used as the wireless data
transceiver in short-ranges, with the small size, low weight and low power consumption, it
has good stability and reliability. This Narrow-band wireless data trasceiver's channel
spacing is as low as 25 KHz.
II
II:: Features:
PERFORMANCE
Power Output:
10mW(Default), (10~100mW optional)
RF Line-of-sight Range:
1000m@1200bps; 600m@9600bps
RF Effective Rate:
1200/2400/4800/9600/19200bps
Space Channel:
1MHz(Default),(12.5/25KHz/other customization )
Bandwidth:
<25KHz
Receiver Sensitivity:
-123dBm@1200bps(1% BER)
NETWORKING
Networking Topology:
Point-to-point, point-to-multipoint
COMPATIBILITY
KYL-200 and KYL-300 series
POWER
Supply Voltage:
5V DC (default), 3.3-3.6V( optional)
Transmit Current:
<40mA
Receive Current:
<20mA
Sleep current:
<20uA
GENERAL
Communication Mode:
Half-duplex
Frequency Band:
400-470MHz, 868MHz,915MHz
Channel:
8(default),16/32/64(optional)
Interface:
TTL/UART, Non-Standard RS232/RS485/USB
Web: www.rf-data.com
Email: [email protected]
Fax: 86-755-73408785
zhen KYL Communication Equipment Co
., Ltd
Shen
Shenz
Co.
PHYSICAL PROPERTIES
Size:
28mm×15mm×10mm
(excluding antenna base and data pin)
Weight:
20g
Antenna Base:
50Ω, SMA
Operating Temperature:
Industrial:-40℃~+85℃(TCXO)
Frequency Stability:
±2.5ppm Industrial
CERTIFICATIONS
FCC/RoHS/CE
S:
III
III:: Applic
Applicaation of KYL-500
500S
KYL-500S the micro power wireless transceiver data module is suitable for:
* AMR Automatic Meter Reading
* Wireless alarm and security systems
* Building automation, security, wireless monitoring and control
* Wireless data transmission, automatic data collection system;
* Radio modem can be used for Sports training & competition;
* Wireless dishes ordering;
* Wireless POS, PDA wireless smart terminal;
* RF modem can be used for Electronic bus station and intelligent traffic;
* RF transmitter Wireless electronic display screen and queuing machine;
* Wireless telemetry Charging for parking, parking lot;
* Wireless modem Automobile inspection and four-wheel orientation;
* Data communication used for railway, oil field, dock and army.
* LED display in thruway and public places
* Point to multi-point wireless network, wireless on-the-spot bus and automatic data
collection system;
S
IV: How to use the KYL-500
500S
KYL-500S provide RS-232, RS-485 and UART/TTL interface port for direct
connection with a PC, RS485 devices, monolithic processors and other UART. The
schematic diagram is in the following.
Web: www.rf-data.com
Email: [email protected]
Fax: 86-755-73408785
zhen KYL Communication Equipment Co
., Ltd
Shen
Shenz
Co.
wer supply
1. Po
Pow
The factory default setting is +5V(3.3-3.6V will inform when placing the order).By
using better ripple factor, KYL-500S transceivers can also share power supply with
other equipment. If possible, a voltage-stabilizing chip with 5V voltage is more
recommended as the only power supply than Switch power supply. But if only
switch power supply available, the jam by switch pulse to the transceivers should
be avoided. In addition, the reliable grounding must be used if there is other device
in the system equipment. In case of failing to connect with the ground, it can form
its own grounding but must be absolutely separated from the municipal electric
supply.
nn
ect
ion Definition wi
2. Co
Conn
nnect
ection
witth te
terrminal
KYL-500S transceivers supply one 9-pin connector (JP1), their definitions and
connection methods with terminals are shown in Table 1.
ns and conn
ect
ion met
hods
Table 1: JP1 Pin Definitio
ion
nnect
ection
meth
Pin No. Signal Name
Function
Level
Connection
with terminal
Ground
1
GND
Grounding of power supply
2
Vcc
Power supply DC
5V
3
RxD/TTL
Serial data input to the transceiver
TTL
TxD
4
TxD/TTL
TTL
RxD
5
SGND
Transmitted data out of the
transceiver
Signal
6
A (TXD)
A of RS-485(TxD of RS-232)
A(RxD)
7
B (RXD)
B of RS-485(RxD of RS-232)
B(TxD)
8
SLEEP
Sleep control (input)
TTL
9
RESET
Reset signal(input)
TTL
Web: www.rf-data.com
Email: [email protected]
Sleep signal
Remarks
High level
sleep
Negative
pulse reset
Fax: 86-755-73408785
zhen KYL Communication Equipment Co
., Ltd
Shen
Shenz
Co.
ect
ion schem
w ee
n compu
te
3. Th
Thee conn
nnect
ection
emaatic diag
agrram bet
etw
een
pute
terr and our
le
RF modu
dule
4. Sett
ettiing of chann
nneel, inter
terfface
ce,, and data format
Before using KYL-500S, the user needs to make simple configuration based on
its own needs to determine the channel,interface mode and data format. The user
can change or view the module's interface baud rate, channel and address code.
Parameter setting or reading as per the testing software KYLCOM.exe in the PC
(in products box).
n:
5. Installa
allattion dimensio
sion
ct
io
n-ind
ht
6. Th
Thee Fun
unct
ctio
ion
ndiicator lig
ligh
a. The LED indicator light turns red for 0.5S after switching on.
b. The LED indicator light turns green continually while receiving data from air.
c. The LED indicator light turns red continuously when transmitting data into air after
receiving from COM.
Web: www.rf-data.com
Email: [email protected]
Fax: 86-755-73408785
zhen KYL Communication Equipment Co
., Ltd
Shen
Shenz
Co.
d. If the module enables the sleep function, LED indicator light is always dark.
pporte
d protocol and Transmit capability
7. Su
Sup
rted
KYL-500S standard transceivers offer transparent protocol to support various
applications and protocols of users. If the user needs to decrease his cost or ease the
workload of terminal CPU, we can add other specific functions based on the transparent
protocol, such as addressing, data acquisition, command interpretation, etc.
p fun
ct
ion instr
uct
io
n:
8. Slee
eep
unct
ction
tru
ctio
ion
Due to reducing more consumption, KYL-500S transceivers support Sleep function. In
sleep mode, the current consumption is less than 20uA.
p f unct
io
n:
a. How to use the Slee
eep
ctio
ion
The Pin8 ‘SLP’ in JP1 is the signal of sleep control. In high power level, transceiver
stays in working mode. In low power level (<0.5V), transceiver stays in sleep mode.
The SLP signal can convert transceiver from working to sleep mode in 1ms after
falling edge. If the Sleep signal arrives when the transceiver is transmitting data, the
module will enter sleep mode after finishing transmission. From sleep mode to
working, it takes the transceiver 1ms after rising edge.
To disable the opened sleep function of KYL-500S, the SLP (SLEEP) pin should be
definitely connected with 0 or ground.
en
ns about use of sl
ee
p funct
io
n:
b. Att
tten
enttio
ion
slee
eep
ctio
ion
When the sleep function enabled, any supply glitches, such as switch dithering,fire
striking or quick switching on and off, could cause the transceiver to be switched to the
wrong sleep mode. After switching on, users can avoid this error by making a
compulsive restoration once after the CPU delays 100ms.
p Timing Diag
Slee
eep
Diagrram:
ntio
ns of data tr
9. Th
Thee atte
tten
ion
traansmission
a. The delay time (tc) between transmitting and receiving is less than1ms.
Web: www.rf-data.com
Email: [email protected]
Fax: 86-755-73408785
zhen KYL Communication Equipment Co
., Ltd
Shen
Shenz
Co.
Timing diag
iagrram:
iv
wee
n the f irst bit sent by TxD to the
b. Th
Thee delay time of tr
traansce
ceiv
iveers bet
etw
een
first bit rec
receeiv
iveed by RxD.
Due to a data processing will be made on user’s data by KYL-500S
transceiver using FEC (Forward Error Correction) or other correction
algorithm, when RxD of a KYL-500S transceiver ‘A’ receives the data,
then transmits it, the other one transceiver ‘B’ will have a delay (ts) to
receive and transmit by TxD. Different RF data rate causes different delay
time. Please see the specific delay time
below:
RF Date Rate
(bps)
1200
Delay
Ts(mS)
90
RF Date Rate
(bps)
9600
Delay
Ts(mS)
16
2400
48
19200
10
4800
30
ming dia
gram:
Ti
Tim
iag
or deali
ng proce
du
re
c. Err
rror
alin
cedu
dure
re::
To enhance the reliability and stability of user’s systems, a verify bit or a Cyclic
Redundancy Check (CRC) mode is highly recommended to resent the wrong
Web: www.rf-data.com
Email: [email protected]
Fax: 86-755-73408785
zhen KYL Communication Equipment Co
., Ltd
Shen
Shenz
Co.
information while using KYL-500S modules.
nu
mber data tr
d. Largee-nu
num
traansmission
In theory, when the interface data rate is faster than the RF data rate, KYL-500S
transceivers can sent unlimited-long data package, but any long packages more than
120B are not recommended. The length of each package should be between
60~100B. We also recommend user to resent the wrong information using
Automatic Error Request Equipment (ARQ).
Th
Thee analyzing as below:
What if the actual transmission BER (Bit Error Rate) is 10-4, 1 packet with 1KB data,
which is about 10-thousand bits, is sent, theoretically, at least 1 bit will be received
wrongly, then the 1KB information will never be received correctly. But if we
package the data into 10 packets with 100B for each, when all 10 packets are sent,
there will be only 1 packet wrong according to this probability.
After that, resend this wrong packet using ARQ mode. So by resending one more
packet and the efficiency rate is reduced 10%, all data will be absolutely received
correctly.
nn
uratio
n:
10. Ante
tenn
nnaa config
igu
ion
Many appropriative antennas for low power RF modules are selected for meeting
different user antenna configurations. Please ask our Sales office for further
information about the antenna’s dimension and performance.
a. Helical SMA antennas
KYL-ANT-433-10-SMA: 100mm helical SMA antennas with high gain and low cost,
reach a long distance.
KYL-ANT-433-3-SMA: 28mm SMA helical antenna with magnetic core, small size,
beautiful appearance (like the mobile phone antenna)
KYL-ANT-433-10-ZSMA: 100mm SMA helical antenna with folding joint, easy for
adjusting the direction and fixing.
Web: www.rf-data.com
Email: [email protected]
Fax: 86-755-73408785
zhen KYL Communication Equipment Co
., Ltd
Shen
Shenz
Co.
b. Magnetic vehicle antenna
KYL-ANT-O433S-300H1.5-SMA: include magnetic antenna base, suitable for
equipment with metal shell, easy for fixing, effective to enhance the transmission
distance.
More kinds of antenna, please browse our website:
http://www.rf-data.com/Products_list_en.asp?classid=163
If the user has special demands on antennas, we can design and produce for them
specially.
Web: www.rf-data.com
Email: [email protected]
Fax: 86-755-73408785