zhen KYL Communication Equipment Co ., Ltd Shen Shenz Co. KYL-500 S Smart Wi 500S Wirreless le Tran anssceiver Data Modu Module Shenzhen KYL Communication Equipment Co., Ltd Address: C3705-3707, Huangdu Square, South of Exhibition Center, Yitian Road, Futian District, Shenzhen, Guangdong, China 518048 Tel: 86-755-82943662 Fax: 86-755-83408785 Skype Skype:KYL-Sunny Yahoo messenger: [email protected] MSN: [email protected] Email: [email protected] Website: http://www.rf-data.com Web: www.rf-data.com Email: [email protected] Fax: 86-755-73408785 zhen KYL Communication Equipment Co ., Ltd Shen Shenz Co. Before using the product please read the use manual carefully. Any question in technical, you can contact us. out KYL-500 S I: Ab Abo 500S KYL-500S, the micro power wireless transceiver data module is used as the wireless data transceiver in short-ranges, with the small size, low weight and low power consumption, it has good stability and reliability. This Narrow-band wireless data trasceiver's channel spacing is as low as 25 KHz. II II:: Features: PERFORMANCE Power Output: 10mW(Default), (10~100mW optional) RF Line-of-sight Range: 1000m@1200bps; 600m@9600bps RF Effective Rate: 1200/2400/4800/9600/19200bps Space Channel: 1MHz(Default),(12.5/25KHz/other customization ) Bandwidth: <25KHz Receiver Sensitivity: -123dBm@1200bps(1% BER) NETWORKING Networking Topology: Point-to-point, point-to-multipoint COMPATIBILITY KYL-200 and KYL-300 series POWER Supply Voltage: 5V DC (default), 3.3-3.6V( optional) Transmit Current: <40mA Receive Current: <20mA Sleep current: <20uA GENERAL Communication Mode: Half-duplex Frequency Band: 400-470MHz, 868MHz,915MHz Channel: 8(default),16/32/64(optional) Interface: TTL/UART, Non-Standard RS232/RS485/USB Web: www.rf-data.com Email: [email protected] Fax: 86-755-73408785 zhen KYL Communication Equipment Co ., Ltd Shen Shenz Co. PHYSICAL PROPERTIES Size: 28mm×15mm×10mm (excluding antenna base and data pin) Weight: 20g Antenna Base: 50Ω, SMA Operating Temperature: Industrial:-40℃~+85℃(TCXO) Frequency Stability: ±2.5ppm Industrial CERTIFICATIONS FCC/RoHS/CE S: III III:: Applic Applicaation of KYL-500 500S KYL-500S the micro power wireless transceiver data module is suitable for: * AMR Automatic Meter Reading * Wireless alarm and security systems * Building automation, security, wireless monitoring and control * Wireless data transmission, automatic data collection system; * Radio modem can be used for Sports training & competition; * Wireless dishes ordering; * Wireless POS, PDA wireless smart terminal; * RF modem can be used for Electronic bus station and intelligent traffic; * RF transmitter Wireless electronic display screen and queuing machine; * Wireless telemetry Charging for parking, parking lot; * Wireless modem Automobile inspection and four-wheel orientation; * Data communication used for railway, oil field, dock and army. * LED display in thruway and public places * Point to multi-point wireless network, wireless on-the-spot bus and automatic data collection system; S IV: How to use the KYL-500 500S KYL-500S provide RS-232, RS-485 and UART/TTL interface port for direct connection with a PC, RS485 devices, monolithic processors and other UART. The schematic diagram is in the following. Web: www.rf-data.com Email: [email protected] Fax: 86-755-73408785 zhen KYL Communication Equipment Co ., Ltd Shen Shenz Co. wer supply 1. Po Pow The factory default setting is +5V(3.3-3.6V will inform when placing the order).By using better ripple factor, KYL-500S transceivers can also share power supply with other equipment. If possible, a voltage-stabilizing chip with 5V voltage is more recommended as the only power supply than Switch power supply. But if only switch power supply available, the jam by switch pulse to the transceivers should be avoided. In addition, the reliable grounding must be used if there is other device in the system equipment. In case of failing to connect with the ground, it can form its own grounding but must be absolutely separated from the municipal electric supply. nn ect ion Definition wi 2. Co Conn nnect ection witth te terrminal KYL-500S transceivers supply one 9-pin connector (JP1), their definitions and connection methods with terminals are shown in Table 1. ns and conn ect ion met hods Table 1: JP1 Pin Definitio ion nnect ection meth Pin No. Signal Name Function Level Connection with terminal Ground 1 GND Grounding of power supply 2 Vcc Power supply DC 5V 3 RxD/TTL Serial data input to the transceiver TTL TxD 4 TxD/TTL TTL RxD 5 SGND Transmitted data out of the transceiver Signal 6 A (TXD) A of RS-485(TxD of RS-232) A(RxD) 7 B (RXD) B of RS-485(RxD of RS-232) B(TxD) 8 SLEEP Sleep control (input) TTL 9 RESET Reset signal(input) TTL Web: www.rf-data.com Email: [email protected] Sleep signal Remarks High level sleep Negative pulse reset Fax: 86-755-73408785 zhen KYL Communication Equipment Co ., Ltd Shen Shenz Co. ect ion schem w ee n compu te 3. Th Thee conn nnect ection emaatic diag agrram bet etw een pute terr and our le RF modu dule 4. Sett ettiing of chann nneel, inter terfface ce,, and data format Before using KYL-500S, the user needs to make simple configuration based on its own needs to determine the channel,interface mode and data format. The user can change or view the module's interface baud rate, channel and address code. Parameter setting or reading as per the testing software KYLCOM.exe in the PC (in products box). n: 5. Installa allattion dimensio sion ct io n-ind ht 6. Th Thee Fun unct ctio ion ndiicator lig ligh a. The LED indicator light turns red for 0.5S after switching on. b. The LED indicator light turns green continually while receiving data from air. c. The LED indicator light turns red continuously when transmitting data into air after receiving from COM. Web: www.rf-data.com Email: [email protected] Fax: 86-755-73408785 zhen KYL Communication Equipment Co ., Ltd Shen Shenz Co. d. If the module enables the sleep function, LED indicator light is always dark. pporte d protocol and Transmit capability 7. Su Sup rted KYL-500S standard transceivers offer transparent protocol to support various applications and protocols of users. If the user needs to decrease his cost or ease the workload of terminal CPU, we can add other specific functions based on the transparent protocol, such as addressing, data acquisition, command interpretation, etc. p fun ct ion instr uct io n: 8. Slee eep unct ction tru ctio ion Due to reducing more consumption, KYL-500S transceivers support Sleep function. In sleep mode, the current consumption is less than 20uA. p f unct io n: a. How to use the Slee eep ctio ion The Pin8 ‘SLP’ in JP1 is the signal of sleep control. In high power level, transceiver stays in working mode. In low power level (<0.5V), transceiver stays in sleep mode. The SLP signal can convert transceiver from working to sleep mode in 1ms after falling edge. If the Sleep signal arrives when the transceiver is transmitting data, the module will enter sleep mode after finishing transmission. From sleep mode to working, it takes the transceiver 1ms after rising edge. To disable the opened sleep function of KYL-500S, the SLP (SLEEP) pin should be definitely connected with 0 or ground. en ns about use of sl ee p funct io n: b. Att tten enttio ion slee eep ctio ion When the sleep function enabled, any supply glitches, such as switch dithering,fire striking or quick switching on and off, could cause the transceiver to be switched to the wrong sleep mode. After switching on, users can avoid this error by making a compulsive restoration once after the CPU delays 100ms. p Timing Diag Slee eep Diagrram: ntio ns of data tr 9. Th Thee atte tten ion traansmission a. The delay time (tc) between transmitting and receiving is less than1ms. Web: www.rf-data.com Email: [email protected] Fax: 86-755-73408785 zhen KYL Communication Equipment Co ., Ltd Shen Shenz Co. Timing diag iagrram: iv wee n the f irst bit sent by TxD to the b. Th Thee delay time of tr traansce ceiv iveers bet etw een first bit rec receeiv iveed by RxD. Due to a data processing will be made on user’s data by KYL-500S transceiver using FEC (Forward Error Correction) or other correction algorithm, when RxD of a KYL-500S transceiver ‘A’ receives the data, then transmits it, the other one transceiver ‘B’ will have a delay (ts) to receive and transmit by TxD. Different RF data rate causes different delay time. Please see the specific delay time below: RF Date Rate (bps) 1200 Delay Ts(mS) 90 RF Date Rate (bps) 9600 Delay Ts(mS) 16 2400 48 19200 10 4800 30 ming dia gram: Ti Tim iag or deali ng proce du re c. Err rror alin cedu dure re:: To enhance the reliability and stability of user’s systems, a verify bit or a Cyclic Redundancy Check (CRC) mode is highly recommended to resent the wrong Web: www.rf-data.com Email: [email protected] Fax: 86-755-73408785 zhen KYL Communication Equipment Co ., Ltd Shen Shenz Co. information while using KYL-500S modules. nu mber data tr d. Largee-nu num traansmission In theory, when the interface data rate is faster than the RF data rate, KYL-500S transceivers can sent unlimited-long data package, but any long packages more than 120B are not recommended. The length of each package should be between 60~100B. We also recommend user to resent the wrong information using Automatic Error Request Equipment (ARQ). Th Thee analyzing as below: What if the actual transmission BER (Bit Error Rate) is 10-4, 1 packet with 1KB data, which is about 10-thousand bits, is sent, theoretically, at least 1 bit will be received wrongly, then the 1KB information will never be received correctly. But if we package the data into 10 packets with 100B for each, when all 10 packets are sent, there will be only 1 packet wrong according to this probability. After that, resend this wrong packet using ARQ mode. So by resending one more packet and the efficiency rate is reduced 10%, all data will be absolutely received correctly. nn uratio n: 10. Ante tenn nnaa config igu ion Many appropriative antennas for low power RF modules are selected for meeting different user antenna configurations. Please ask our Sales office for further information about the antenna’s dimension and performance. a. Helical SMA antennas KYL-ANT-433-10-SMA: 100mm helical SMA antennas with high gain and low cost, reach a long distance. KYL-ANT-433-3-SMA: 28mm SMA helical antenna with magnetic core, small size, beautiful appearance (like the mobile phone antenna) KYL-ANT-433-10-ZSMA: 100mm SMA helical antenna with folding joint, easy for adjusting the direction and fixing. Web: www.rf-data.com Email: [email protected] Fax: 86-755-73408785 zhen KYL Communication Equipment Co ., Ltd Shen Shenz Co. b. Magnetic vehicle antenna KYL-ANT-O433S-300H1.5-SMA: include magnetic antenna base, suitable for equipment with metal shell, easy for fixing, effective to enhance the transmission distance. More kinds of antenna, please browse our website: http://www.rf-data.com/Products_list_en.asp?classid=163 If the user has special demands on antennas, we can design and produce for them specially. Web: www.rf-data.com Email: [email protected] Fax: 86-755-73408785