LINEAGEPOWER CAR1212FPCY0-1A

CAR1212FP Series
1200 Watt +12V Front End Power Supply
Features:
∎ Measures 11.20 x 4.00 x 1.65” / 284.5 x 101.6 x 41.9mm
∎ 12V Power for Powering Non-Isolated POL Converters
∎ Hot Swap / N+1 Redundant
∎ Active Single Wire Current Sharing
∎ Remote On/Off Control
∎ International Safety Approvals - UL, CSA, CE Mark (LVD) TUV
FEATURES
BENEFITS
KEY MARKETS & APPLICATIONS
High Power Density 16W/in3
Minimizes space within your system
∎ Distributed Power ∎ Blade Servers
1U High Form Factor
Supports low profile applications
∎ Mid-End Servers
5VSB Standby Voltage
Provides voltage source for housekeeping and monitoring circuitry
∎ Network Attached Storage
I 2C Digital Control & Monitoring
Cost effective power scalability
∎ Storage Area Networks
SPECIFICATIONS
1200 Watt +12V Front End Power Supply
Input Voltage Range
85-264 VAC, 47-63 Hz
Input Current Maximum
12A @ 100VAC, 8.1A @ 180 VAC, full Load
Inrush Current
35A max. cold start (per ETS 300 132-1 and bellcore specifications)
Input Protection
Single Fused (Line) 20 Amp / 250 VAC Type 3AB Axial
Power Factor
0.99 typical complies with IEC555, EN60555-2, EN61000-3-2
Efficiency
89% typical at 230 VAC Full Load Operation, 85% Typical @ 90 VAC Full Load Operation
Output Power
1200W at High Line Operation (230 VAC), Derate to 1000W
Output Voltage Range
+12 VDC (±5%)
Output Current
100A @ +12 VDC for High Line Operation (230 VAC), reduced to 83.5 A at Low Line Operation (110 VAC)
Voltage Programming
±5% of Vout nominal. Analog input signal. 11.4V + (Vprog x 0.3V) where Vprog = 0V to 4V
Standby Bias Voltage
5VSB@500mA, reference to +12VDC Return
Voltage Regulation
±2% of Vnom for any combination of line, load and temperature
Ouput Ripple & Noise
ETS300 132-2, 32dBnrc. Bandwidth: 25Hz - 20kHz. 2mVrms pk-pk with 0.1µF ceramic and 10µF electrolytics caps
Transient Response
5% max deviation Recovery time 300µs @ 50% load step and di/dt < 1A/µs
Switching Frequency
400kHz (output)
Hold-Up Time
20ms at 1200W (typical) @ 180VAC
Remote On/Off
ON if >3V or open; OFF if <1V (max. sink 1mA) Open collector type
Current Limit Protection
110-135% of Iout Nominal
Short Circuit Protection
Self protected with auto recovery
Over Voltage Protection
+14.5-15.5 VDC max, latched. Reset condition by recycling AC Input or toggling remote on/off
Operating Temperature
-10°C to +70°C. power derating above 55°C at 2.5% per °C
Over Temperature Protection
Non latching; protection active at 110°C internal temperature, restart at 95°C (typical)
EMI
FCC-B & EN55022-B with specified filter, GR-1089-CORE
LED Indicators
Green = AC OK & DC OK, Red = Fault
Analog Status & Control
Voltage Programming (V Prog), Load sharing (I Share), Remote ON/OFF, Current Monitor (I Monitor),, Over temperature
(Temp Warning), Fault, PS Present, Module Enable
Digital Status & Control
I 2C Option, see detailed specification for details
Shock & Vibration
IEC68-2-27, MIL-STD-810E, Telecordia GR-63-CORE
Dimensions
11.20 x 4.00 x 1.65” / 284.5 x 101.6 x 41.9mm
Weight
3.0 lbs
Safety Approvals
IEC 950 per EN60950, UL60950, CSA 22.2-950, CE Mark (LVD) TUV
Options
I2C Signals, Bezel
rev 100506
∎ Network Equipment
www.lineagepower.com/oem
Lineage Power
Lineage Power
Lineage Power (China)
3000 Skyline Dr.
Mesquite, TX 75149 Phone: (972) 284-2000
2841 Dow Avenue Tustin, CA 92780 USA Phone: (714) 544-6665
1353 Chenqiao Road, Shanghai Sengpu Industrial Park
Shanghai, 201401 China Phone: 021 6710 8910
CAR1212FP Series
1200 Watt +12V Front End Power Supply
OUTLINE DRAWING
PART NUMBER DEFINITION GUIDE:
PIN OUT INFORMATION
A1
Vstb (5V)
B4
PS Present
D1
V Prog
P4
+V1 Return
A2
Vstb (5V) Return
B5
Serial Data Line
D2
OVP Test Point
P5
+V1 Return
A3
Signal Return
B6
Serial Data Clock
D3
Remote On/Off
P6
+V1 Return
A4
Write Protect
C1
I Share
D4
DC OK
P7
+V1 Output
A5
Remote Sense (+)
C2
N/C
D5
AC OK
P8
+V1 Output
A6
Remote Sense (-)
C3
Temp Warning
D6
Interrupt
P9
+V1 Output
B1
Fault
C4
I2C Address (A0)
P1
Line
B2
I Monitor
C5
I2C Address (A1)
P2
Neutral
B3
Module Enable
C6
I2C Address (A2)
P3
Chassis
CAR 12 12 F P x xx -1A
Series
12=1200W
Output Current
12=12V
Output Voltage
F=Front End
Type
P=Positive
Polarity
Rev.
Blank=Non-compliant
YO=5 of 6 Compliant
ZO=6 of 6 Compliant
RoHS
B=Bezel Option
C=I2C Option
BC=Both Options
Options
Examples:
CAR1212FPY0-1A:
1200W/12V Front End, 5 of 6 RoHS
CAR1212FPBZ0-1A
1200W/12V Front End, Bezel, 6 of 6 RoHS
CAR1212FPCY0-1A
1200W/12V Front End, I2C, 5 of 6 RoHS
CAR1212FPBCZ0-1A
1200W/12V Front End, I2C, Bezel, 6 of 6 RoHS
D1 D2 D3 D4 D5 D6
P1
P2
P3
P4
P5
P6
P7
P8
P9
C1 C2 C3 C4 C5 C6
B1 B2 B3 B4 B5 B6
A1 A2 A3 A4 A5 A6
Connector is FCI / Berg Part No. 51939-178
Mates with FCI / Berg Part No. 51866-025 (Right Angle
Mounting), or 51940-117 (Straight Mounting)
rev 100506
www.lineagepower.com/oem
Lineage Power
Lineage Power
Lineage Power (China)
3000 Skyline Dr.
Mesquite, TX 75149 Phone: (972) 284-2000
2841 Dow Avenue Tustin, CA 92780 USA Phone: (714) 544-6665
1353 Chenqiao Road, Shanghai Sengpu Industrial Park
Shanghai, 201401 China Phone: 021 6710 8910