LINEAGEPOWER CAR1212DC5Z0-1A

CAR1212DC
1200 Watt, +12V DC Input Front End
by Lineage Power
Features:
∎ Compact 1U High Profile
∎ Constant Current Characteristic
∎ Visual LED Indicators
∎ Hot Plug / Redundant Parallel Operation with Active Load Sharing
∎ No Minimum Load Requirements
∎ Analog, I2C, and PMBuss control and monitoring
∎ Four (4) CAR1212DC Modules per Rack
∎ 3.6KW N+1 Capability/ or 4.8KW Total Power
FEATURES
High Power Density >16W/in3
Load Sharing & Fault Tolerant
Automatic Fan Speed Control
System Scalability up to 4.8kW
Universal Input & International
Certifications
BENEFITS
More system space for application circuits and hardware
Excellent reliability in N+1 operation
Reduces audible noise and increases reliability
Allows flexibility with minimum investment
Reduces logistical costs
SPECIFICATIONS
Input Voltage Range
1,200 Watt +12V Front End Power Supply with 48 VDC Input Range
-36 ~ -75 VDC Input Range
Turn off (Hysteresis)
-32 VDC Turn Off
Input Current Maximum
38A, -36VDC Input, Full Load and 89% Efficiency (max)
Input Protection
Two fuses in the negative leg rated at 30 Amps Each
Efficiency
90% typical, at 12Vdc output, -48Vdc nominal input (including Oring Mosfets). Peak Efficiency at 60-80% load
Hold-Up Time
2.5ms at 1200W (typical) nominal -48Vdc
Isolation
1500 VDC Input to Output, 100 VDC Input to Frame
Output Voltage Range
10.8~13.2 VDC with remote programming
Output Current
100A @ 12Vout (max continuous)
Standby Bias Voltage
3.3VSB @ 1A (optional 5VSB)
Voltage Regulation
±2% of Vnom for any combination of line, load and temperature
Output Ripple & Noise
1% (pk-pk) @ 20MHz with 0.1µF ceramic and 10µF Tantalum caps at the output
Transient Response
5% max deviation Recovery time 300μs @ 50% load step and di/dt < 1A/μs
Remote On/Off
ON if >3V or open; OFF if <1V (max. sink 1mA)
Current Limit Protection
110~130A, Constant current 12Vdc down to 11.8vdc. True constant current for Isc Non–hiccup mode (adjustable via I2C)
Short Circuit Protection
Self protected with auto recovery
Over Voltage Protection
Trip level >14.5~15.5V, Reset condition by recycling the AC input or applying Remote or software ON/OFF
Operating Temperature
-10°C to +70°C. power derating above 50°C at change 2.5%/°C (startup @ -40C, within spec @ 30 min of warm up)
Over Temperature Protection
Non-Latching, thermal shutdown point is set for 120°C and recovery point is 110°C
EMI
FCC-B & EN55022-B with specified filter or at rack level, GR-1089-CORE
LED Indicators
3 LED Indicators to indicate Green = Input OK / Green = DCOK / Amber = Fault
Analog Status & Control
Voltage Programming (V Prog), Load sharing (I Share), Remote On/Off, Current Monitor (I Monitor), Input OK, DC OK,
Temperature Warning, Fault, PS Present, Module Enable,
Digital Status & Control
I2C and PMBus, see detailed specification for details
Shock & Vibration
NEBS GR-63-CORE Level 3
Dimensions
11.20 x 4.00 x 1.65” / 284.5 x 101.6 x 41.91mm
Safety Approvals
IEC/UL/CSA/EN60950-1, CE Mark (LVD)
Options
5VSB Output
KEY MARKET SEGMENTS & APPLICATIONS
∎ Distributed Power
∎ RF Amplifiers
∎ High End Servers
∎ ATE Equipment
∎ High End Routers and Switchgear
∎ Semiconductor Burn-in Equipment
www.LineagePower.com
rev 100225
Lineage Power
Lineage Power
Lineage Power (China)
3000 Skyline Dr.
Mesquite, TX 75149 Phone: (972) 284-2000
2841 Dow Avenue Tustin, CA 92780 USA Phone: (714) 544-6665
1353 Chenqiao Road, Shanghai Sengpu Industrial Park
Shanghai, 201401 China Phone: 021 6710 8910
CAR1212DC
11200 Watt, +12V DC Input Front End
by Lineage Power
OUTLINE DRAWING
All Dimensions in Inches (mm)
Tolerance: .XX = ± .02 in (.50 mm)
.XXX = ± .010 in (.254 mm)
LED INDICATOR
TEST CONDITION
1 NORMAL OPERATION
2 OUT OF INPUT RANGE
3 OVP
4 OVER CURRENT
5 THERMO ALARM
INP OK
Green
Off
Green
Green
Green
DC OK
Green
Off
Off
Off
Green
FAULT
Off
Red
Red
Red
Red
MONITORING SIGNALS
DC OK
INP OK
Low
Low
High
High
High
Low
High
Low
Low
Low
FAULT
Low
High
High
High
High
TEMP OK
High
High
High
High
Low
Test condition # 2 had two modules plug in. One module running and the other module with no DC input
PART NUMBER DEFINITION GUIDE:
CONNECTOR DRAWING:
CAR 12 12 DC B x xx -1A
Series
12=1200W
Output Current
12=12V
Output Voltage
DC= 48Vin
Front End
Type
B=Bezel
Faceplate
Rev.
Blank=Non-compliant
YO=5 of 6 Compliant
ZO=6 of 6 Compliant
RoHS
5=5VSB
Options
Output Connector: Molex 46437-1041
Examples:
CAR1212DCB-Z01A
12V Front, 6 of 6 RoHS Compliant
CAR1212DCB5-Y01A
12V Front End, 5VSB 5 of 5 RoHS Compliant
rev 100225
Pin
A1
A2
A3
A4
A5
A6
A7
A8
B1
B2
B3
B4
Functions
VPROG
PS_Present
OVP Test Point
Fault Signal
Remote Sense (+)
Temp Warning
N/C
Remote Sense (-)
Write Protect
DC OK
INP OK
Signal Return
Pin
B5
B6
B7
B8
C1
C2
C3
C4
C5
C6
C7
C8
Function
Interrupt (/SMBALERT)
Iout Monitor
Vstb
Module Enable (Short pin)
Remote ON/OFF
SDA
SCL
Vstb Return
I²C Address (A2)
I²C Address (A1)
I²C Address (A0)
I Share
Pin
P1
P2
P3
P4
P5
P6
P7
P8
P9
Functions
+48Vdc
-48Vdc Return
PE
+12Vout
+12Vout
+12Vout
Output Return
Output Return
Output Return
www.LineagePower.com
Lineage Power
Lineage Power
Lineage Power (China)
3000 Skyline Dr.
Mesquite, TX 75149 Phone: (972) 284-2000
2841 Dow Avenue Tustin, CA 92780 USA Phone: (714) 544-6665
1353 Chenqiao Road, Shanghai Sengpu Industrial Park
Shanghai, 201401 China Phone: 021 6710 8910
E