MAKE-PS 1500UR

www.make-ps.com
E-mail:[email protected]
1500UR series
Single & Dual Output
DC/DC Converter
FEATURES
• 6 sided Continuous Shielding
• 4:1 Ultra-Wide Input Voltage Range
• Output Voltage Trim (Single Output only)
• -25oC to +75oC Operating Temperature Range
• Efficiency to 83%
• 1400 VDC Input/Output Isolation
• 9.4W/In3 Power Density
DESCRIPTIONS
INPUT CHARACTERISTICS
The 1500UR series is a family of miniature 15W DC/DC
converters specifically designed for board mount power
distribution applications where space is critical, but
performance and power cannot be sacrificed. Standard
features include an ultra-wide 4:1 input voltage range,
efficiency as high as 83% and continuous short circuit
protection by input current limiting. 14 models operate from
(4:1) input voltage ranges of 10 to 40 VDC or 18 to 72 VDC and
provide tightly regulated outputs of 3.3, 5, 12, 15, ±5, ±12 or
±15 VDC. All models are packaged in a compact, low profile
2” X 2” X 0.4” metal case.
Input Voltage
20 VDC Input Models
36 VDC Input Models
Input Fuse Requirements
20 VDC Input Models
36 VDC Input Models
Reverse Polarity Input
Current
Input Filter
Min Typ Max Unit/Comments
10
18
20
36
40
72
2000
1000
12
VDC
VDC
mA; Slow blow type
mA; Slow blow type
Amp
LC Type
OUTPUT CHARACTERISTICS
Min Typ Max Unit/Comments
Output Voltage Accuracy
±100 mV 1
3.3V Outputs
±1.0 % 1
All Other Models
Voltage Balance:
±2.0 %; Equal Output Loads
Dual Outputs
Voltage Trim Range (Single Only)
±3.0 %
3.3 Vout
±5.0 %; Output Voltage
All Other Models
±1.0 % 2
Line Regulation
±1.0 % 3
Load Regulation
Ripple/Noise
100 mV; p-p, Nom.Line FL,
3.3V Outputs
20Mhz B.W. using
1 μf bypass capacitor
1.25 %; p-p, Nom.Line FL,
All Other Models
20Mhz B.W. using
1μf bypass capacitor
Continuous, AutoShort Circuit Protection
matic Recovery
300 μS to within1% error
Transient Recovery Time
band for 50% step
load change
±0.02 % per oC
Temperature Coefficient
1
2
3
= Output voltage at nominal line & FL
= Output voltage measured from minimum input line to maximum
= Output voltage measured from FL to 10% Load
GENERAL CHARACTERISTICS
Switching Frequency
Isolation Voltage
Isolation Resistance
Isolation Capacitance
MTBF (MIL-HBK-217F)
Min Typ Max Unit/Comments
kHz
130
VDC, 1 minute
1400
Mohm, 500VDC
1000
pF, 100kHz, 1Volt
100
Thousand Hours,
865
+25oC, Ground
Benign
>> B-137
www.make-ps.com
E-mail:[email protected]
ENVIRONMENTAL SPECIFICATIONS
Operating Temp. Range
Storage Temp. Range
Relative Humidity
Min
-25
-55
PHYSICAL CHARACTERISTICS
Typ Max
+75
+125
+95
Cooling
Unit/Comments
C; Ambient
o
C
% Humidity; noncondensing
Free-Air Convection
o
Unit/Comments
2.0 X 2.0 X 0.4 inches
(51.0 X 51.0 X 10.2 mm)
Coated Metal with NonConductive Base
Case Size
Case Material
Shield Connection
20 VDC Input Models
36 VDC Input Models
Flammability
Weight
Negative Input, Pin 2
Positive Input, Pin 1
UL94V-0
79 Grams
OUTLINE DRAWING
2.00 (50.8)
3
4
+Vout
0.60
(15.2)
0.40
(10.2)
0.40
(10.2)
0.040± .005
(1.01)
DIA.
5
COM -Vout
2.00
0.80 (50.8)
(20.3)
BOTTOM
SIDE
+Vin -Vin
1
0.20
(5.1)
2
0.60
(15.2)
0.90
(22.9)
0.22MIN.
(5.6)
0.40
(10.2)
PIN OUT CHART
Pins
1
2
3
4
5
Single
+Vin
- Vin
+ Vout
Trim
- Vout
Dual
+ Vin
- Vin
+ Vout
± Common
- Vout
Notes:
1. Unless otherwise specified dimensions are in inches (mm).
Tolerances
Inches
mm
X.XX = ±0.02
X.X = ±0.5
X.XXX= ±0.010
X.XX = ±0.25
All specifications are typical at nominal input, nominal load and 25° C unless otherwise specified.
External, low ESR, 10 microfarad (minimum) capacitor across output is recommended for operation.
>> B-138
www.make-ps.com
E-mail:[email protected]
HOW TO ORDER
HOW TO ORDER
15 XX D XX UR
Wattage
Output Voltage
Output
Configuration
(S=Single,D=Dual)
Series
Nominal
Input Voltage
MODEL SELECTION CHART
Model
1503S20UR
1505S20UR
1512S20UR
1515S20UR
1505D20UR
1512D20UR
1515D20UR
1503S36UR
1505S36UR
1512S36UR
1515S36UR
1505D36UR
1512D36UR
1515D36UR
Nominal
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Full Load
Output
Current
(mA)
No Load
Input
Current
(mA)
Full Load
Input
Current
(mA)
Output Over
Voltage
(V)
Efficiency
@ FL
(%)
20
20
20
20
20
20
20
36
36
36
36
36
36
36
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
4500
3000
1250
1000
±1500
±625
±500
4500
3000
1250
1000
±1500
±625
±500
40
40
40
40
40
40
40
40
40
40
40
40
40
40
900
900
960
950
920
960
1000
500
500
510
500
510
520
520
5.8
6.8
15
18
±6.8
±15
±18
5.8
6.8
15
18
±6.8
±15
±18
82
83
78
79
81
78
75
82
83
81
83
81
80
80
>> B-139
www.make-ps.com
E-mail:[email protected]
OUTPUT VOLTAGE TRIM (1500UR SERIES, SINGLE OUTPUT ONLY)
The converter’s output voltage may be trimmed to ±5% of the nominal output voltage.
TRIM UP
Trim output voltage up by connecting an external resistor between Pins 4 and 5. Use the following equation.
Reference Table 1 for variable A.
Radj-up =
A
Δ%
- 24 (kΩ)
Example:
If we want to trim 5% up for 12V output units,
where A = 1.97, Δ % = 0.05
Radj-up =
1.97
0.05
- 24 kΩ = 15.4 kΩ
Table 1.
Output Voltage
A
3.3V
5V
12V
15V
0.75
1.25
1.97
2.07
TRIM DOWN
Trim output voltage down by connecting an external resistor between Pins 3 and 4. Use the following
equation. Reference Table 2 for variable C and D.
Radj-down =
C
Δ%
- D (kΩ)
Example:
If we want to trim 2% down for 5V output units,
where C = 1.25, D = 26.5, Δ % = 0.02
Radj-down =
1.25
0.02
- 26.5 kΩ = 36 kΩ
Table 2.
Output Voltage
C
D
3.3V
5V
12V
1.25
1.25
7.55
26
26.5
33.5
15V
10.3
36.4
>> B-140