MEANWELL P50A14E-R1B

P50A-T
46.5~50W AC-DC Triple Output Desktop
series
Features :
3 pole AC inlet IEC320-C14
Class power (with earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
Fix switching frequency and regulation
Topology: PWM 3882 circuit
LED indicator for power on
Approvals: UL / CUL / TUV / CB / CE
1 year warranty
TUV
Rheinland
Product Safety
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
P50A13D-R1B
P50A14E-R1B
PSU50A-13D
PSU50A-14E
12V
-5V
5V
12V
-12V
5V
15V
-15V
RATED CURRENT
4A
2A
0.5A
4A
2A
0.5A
4A
1.5A
0.5A
CURRENT RANGE
0.5 ~ 4.0A
0.5 ~ 2.0A
0.1 ~ 0.5A
0.5 ~ 4.0A
0.5 ~2.0A
0.1 ~0.5A
0.5 ~ 4.0A
0.5 ~ 1.5A
0.1 ~ 0.5A
RATED POWER
46.5W
100mVp-p
100mVp-p
DC VOLTAGE
OUTPUT
P50A13A-R1B
PSU50A-13A
Note.2 5V
geprUfre
Sicherheit
50W
RIPPLE & NOISE (max.) Note.3 50mVp-p
100mVp-p
100mVp-p
50mVp-p
50W
100mVp-p
100mVp-p
50mVp-p
VOLTAGE ADJ. RANGE
Fixed
VOLTAGE TOLERANCE Note.4 6.0%
10%
12%
6.0%
10%
12%
6.0%
10%
12%
LINE REGULATION
Note.5
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION
Note.6
5.0%
10%
10%
5.0%
10%
10%
5.0%
10%
10%
SETUP, RISE, HOLD UP TIME 1.5s, 50ms, 12ms at full load
INPUT
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
70%
AC CURRENT
1.6A / 100VAC
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.)
40A / 230VAC
0.75mA / 240VAC
OVER VOLTAGE
5V: 110 ~ 140% of rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
0 ~ +40
WORKING HUMIDITY
20% ~ 90% RH non-condensing
EMS IMMUNITY
MTBF
NOTE
74%
OVERLOAD
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
(Note. 7)
HARMONIC CURRENT
CONNECTOR
72%
150 ~ 250% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
OTHERS
135~ 370VAC
(Refer to output load derating curve)
-20 ~ +85 , 10 ~ 95% RH
0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1950, CSA22.2, EN60950-1 approved
I/P-O/P:3KVAC , I/P-FG:1.5KVAC
I/P-O/P,I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022(CISPR22) class B
Compliance to EN61000-3-2,3
Compliance to EN61000-4-2,3,4,5,6,11, ENV50204, light industry level, criteria A
280K hrs min. MIL-HDBK-217F (25 )
DIMENSION
PACKING
PLUG
Standard type R1B: DIN 5PIN for stock ; Other type available by customer requested
CABLE
Standard type AWM2464 18Awg*4c with shiell 4ft for stock ; Other type available by customer requested
147*76*43mm (L*W*H)
0.55kg; 36pcs / 21kg / CARTON
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerence: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load.
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:P50A-T-SPEC 2007-05-14
PP5500AA--TT ss ee rriieess
46.5~50W AC-DC Triple Output Desktop
Mechanical Specification
Unit:mm
43
UL2464 18AWG 1220+100/-0
43
144.5
54.8
76
SWITCHING ADAPTOR
10.2
POWER LED
147
Plug Assignment
21.5
144.5
Standard plug: R1B (option)
NAME PLATE
3
1
o
PIN NO
OUTPUT
1
COM
2
COM
3
+5VDC
4
- Vout
5
+Vout
RUBBER FOOTX4
Derating Curve
Static Characteristics
100
LOAD (%)
100
LOAD (%)
45
5 2 4
76
40
42
38
69.9
60
0
10
20
30
Ta (
)
40
80
60
0
50
60
70
80
90 100
260
INPUT VOLTAGE
File Name:P50A-T-SPEC 2007-05-14