SP-500 500W Single Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections: Short circuit / Overload/ Over voltage / Over temperature Forced air cooling by built-in DC fan Built-in cooling Fan ON-OFF control Built-in remote ON-OFF control Built-in remote sense function 3 years warranty ( for 24V only) SPECIFICATION MODEL OUTPUT SP-500-12 SP-500-13.5 SP-500-15 SP-500-24 SP-500-27 DC VOLTAGE 12V 13.5V 15V 24V 27V 48V RATED CURRENT 40A 36A 32A 20A 18A 10A CURRENT RANGE 0 ~ 40A 0 ~ 36A 0 ~ 32A 0 ~ 20A 0 ~ 18A 0 ~ 10A RATED POWER 480W 486W 480W 480W 486W 480W RIPPLE & NOISE (max.) Note.2 240mVp-p 240mVp-p 240mVp-p 240mVp-p 200mVp-p 300mVp-p VOLTAGE ADJ. RANGE 12 ~ 15V 1.0% 13.5 ~ 18V 1.0% 20 ~ 26.4V 1.0% 24 ~ 30V 1.0% 41 ~ 56V 1.0% 10 ~ 13.2V VOLTAGE TOLERANCE Note.3 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 85.5% 86.5% 1500ms, 50ms at full load SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE INPUT PROTECTION FUNCTION 24ms at full load Note.5 88 ~ 264VAC 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY(Typ.) 84% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 7A/115VAC 18A/115VAC PF>0.95/115VAC at full load 84% 83% <3.5mA/240VAC OVERLOAD 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed OVER VOLTAGE 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V 27.6 ~ 32.4V Protection type : Hiccup mode, recovers automatically after fault condition is removed FAN CONTROL, O.T.P. RTH1 or RTH2 REMOTE CONTROL RC+/RC-: Short = power on ; Open = power off -10 ~ +50 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION EMC IMMUNITY MTBF DIMENSION PACKING -20 ~ +85 87% 3.5A/230VAC 36A/230VAC LEAKAGE CURRENT WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION NOTE 124 ~ 370VDC FREQUENCY RANGE WORKING TEMP. OTHERS SP-500-48 50 FAN ON, 45 FAN OFF, 70 31 ~ 36.5V 57.6 ~ 67.2V output shutdown , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, CCC GB4943( for 24V only) approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A 133.4K hrs min. MIL-HDBK-217F (25 170*120*93mm (L*W*H) 1.9Kg; 8pcs/15.5Kg/1.06CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:SP-500-SPEC 2011-11-15 SP-500 500W Single Output with PFC Function Mechanical Specification Unit:mm 58.3 Case No. 910 series 100 Air flow direction 2-M3 L=16mm max. 2-M3 L=4mm max. 150 170 120 1 2 3 4 5 L N FG NC NC R.C.G R.C. 6 150 14 max. 11.5 8 7 Terminal Pin No. Assignment +S 2-M3 L=4mm max. BAUART GEPRUFT TUV Rheinland Product Safety TYPE APPROVED E183223 LEVEL5 2-M3 L=16mm max. 50 (AC ) INPUT 100-240VAC 7A 50/60Hz SP-500-12 MADE IN TAIWAN +12V 40A -V -S +V ADJ. 8 9 10 11 12 13 14 15 9.5 93 SHORT:ON OPEN:OFF Pin No. Assignment 1 AC/L 2 AC/N 3 FG 4,5 NC 6 R.C.G Pin No. 7 8 9~11 12~14 15 Assignment R.C. +S DC OUTPUT +V DC OUTPUT -V -S 11.5 FAN ON/OFF CONTROL Block Diagram ACTIVE INRUSH CURRENT LIMITING EMI FILTER I/P RECTIFIERS & P.F.C. FAN PFC fosc : 100KHz PWM fosc : 67KHz RECTIFIERS & FILTER POWER SWITCHING +V -V RC. G. O.C.P. FG O.L.P. RC DETECTION CIRCUIT PWM CONTROL O.V.P. O.T.P. Derating Curve Output Derating VS Input Voltage 100 100 90 80 80 70 LOAD(%) LOAD (%) 60 40 20 -10 0 10 20 30 40 45 AMBIENT TEMPERATURE ( ) 50 (HORIZONTAL) 60 50 40 88 115 135 155 230 264 INPUT VOLTAGE (V) 60Hz File Name:SP-500-SPEC 2011-11-15