MICREL SY100S360_07

Micrel, Inc.
DUAL PARITY
CHECKER/
GENERATOR
FEATURES
■
■
■
■
■
■
■
■
■
■
SY100S360
SY100S360
DESCRIPTION
The SY100S360 is a dual parity checker/generator and
is designed for use in high-performance ECL systems. The
inputs are segmented into two groups of nine inputs each
and the parity output is at a logic LOW when an even
number of inputs are at a logic HIGH. In each group, one of
the nine inputs (Ia, Ib) has a shorter propagation delay and,
therefore, is ideal as the expansion input for parity
generation of wider data.
A Compare output (C) is also provided which allows
comparison of two 8-bit words. A logic LOW on the C output
indicates a match. The inputs on this device have 75kΩ
pull-down resistors.
Max. propagation delay of 2200ps
IEE min. of –70mA
Industry standard 100K ECL levels
Extended supply voltage option:
VEE = –4.2V to –5.5V
Voltage and temperature compensation for improved
noise immunity
Internal 75kΩ input pull-down resistors
15% faster than Fairchild 300K
Approximately 30% lower power than Fairchild 300K
Function and pinout compatible with Fairchild F100K
Available in 28-pin PLCC package
BLOCK DIAGRAM
I0a
I1a
I2a
I3a
Za
I4a
I5a
I6a
I7a
Ia
C
I0b
I1b
I2b
I3b
I4b
I5b
Zb
I6b
I7b
Ib
M9999-042307
[email protected] or (408) 955-1690
Rev.: I
1
Amendment: /0
Issue Date: April 2007
SY100S360
Micrel, Inc.
I1a
I0a
Ordering Information
I2a
I4a
I3a
VEES
I5a
PACKAGE/ORDERING INFORMATION
11 10 9 8 7 6 5
I6a
12
13
I7a
VEE
4
3
14
15
VEES
I1b
16
17
I2b
18
I0b
Top View
PLCC
J28-1
Ia
Za
VCCA
2
1
VCC
VCC
28
27
C
26
Package
Marking
Lead
Finish
J28-1
Commercial
SY100S360JC
Sn-Pb
J28-1
Commercial
SY100S360JC
Sn-Pb
SY100S360JZ
J28-1
Commercial
SY100S360JZ with
Pb-Free bar-line indicator
Matte-Sn
SY100S360JZTR(1, 2)
J28-1
Commercial
SY100S360JZ with
Pb-Free bar-line indicator
Matte-Sn
SY100S360JC
SY100S360JCTR
(1)
(2)
Notes:
1. Tape and Reel.
2. Pb-Free package is recommended for new designs.
I6b
I7b
Ib
VEES
I4b
I5b
Operating
Range
Zb
19 20 21 22 23 24 25
I3b
Package
Type
Part Number
28-Pin PLCC (J28-1)
TRUTH TABLE(1)
PIN NAMES
Pin
Function
Ia, Ib, Ina, Inb
Data Inputs (n = 1...7)
Za – Zb
Parity Odd Outputs
C
Compare Output
VEES
VEE Substrate
VCCA
VCCO for ECL Outputs
M9999-042307
[email protected] or (408) 955-1690
Sum of
High Inputs
Output
Z
Even
HIGH
Odd
LOW
Note:
1. Comparator Function:
C = (I0a ⊕ I1a) + (I2a ⊕ I3a) + (I4a ⊕ I5a) + (I6a ⊕ I7a) +
(I0b ⊕ I1b) + (I2b ⊕ I3b) + (I4b ⊕ I5b) + (I6b ⊕ I7b)
2
SY100S360
Micrel, Inc.
DC ELECTRICAL CHARACTERISTICS
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
Symbol
IIH
IEE
Parameter
Min.
Typ.
Max.
—
—
—
—
300
200
–70
–45
–30
Input HIGH Current
Ia, Ib
Ina, Inb
Power Supply Current
Unit
Condition
µA
VIN = VIH (Max.)
mA
Inputs Open
AC ELECTRICAL CHARACTERISTICS
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
TA = 0°C
Symbol
Parameter
TA = +25°C
TA = +85°C
Min.
Max.
Min.
Max.
Min.
Max.
Unit
tPLH
tPHL
Propagation Delay
Ina, Inb to Za, Zb
500
2200
500
2200
500
2200
ps
tPLH
tPHL
Propagation Delay
Ina, Inb to C
500
1700
500
1700
500
1700
ps
tPLH
tPHL
Propagation Delay
Ia, Ib to Za, Zb
300
900
300
900
300
900
ps
tTLH
tTHL
Transition Time
20% to 80%, 80% to 20%
300
900
300
900
300
900
ps
TIMING DIAGRAM
0.7 ± 0.1 ns
0.7 ± 0.1 ns
–0.95V
INPUT
80%
50%
20%
–1.69V
TRUE
tPHL
tPLH
50%
tPLH
OUTPUT
tPHL
80%
50%
20%
COMPLEMENT
tTLH
tTHL
Propagation Delay and Transition Times
NOTE:
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
M9999-042307
[email protected] or (408) 955-1690
3
Condition
SY100S360
Micrel, Inc.
28-PIN PLCC (J28-1)
Rev. A
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-042307
[email protected] or (408) 955-1690
4