60 MS/s, 60 MHz, 12-Bit, 8-Channel Digitizers NI 5105 • 8 channels simultaneously sampled at 12-bit resolution • 60 MS/s real-time sampling • 60 MHz bandwidth • 50 mVpp to 30 Vpp input range • 72 dBc SFDR • 16, 128, or 512 MB of onboard memory • Edge, window, hysteresis, and digital triggering Calibration • Gain, offset, frequency response, and timing self-calibration • 2-year external calibration interval Operating Systems • Windows Vista/XP/2000 • LabVIEW Real-Time Recommended Software • LabVIEW • LabWindows™/CVI • Measurement Studio for Visual Studio • LabVIEW SignalExpress Driver Software (included) • NI-SCOPE driver • LabVIEW Express VIs • Scope Soft Front Panel Overview National Instruments 5105 high-resolution digitizers feature eight 60 MS/s simultaneously sampled input channels with 12-bit resolution, 60 MHz bandwidth, and up to 512 MB of memory in a compact, 3U PXI/PXI Express or PCI device. An NI 5105 uses the National Instruments Synchronization and Memory Core (SMC) architecture, so you can combine multiple devices to build up to 136 phase-coherent channels in a single PXI chassis. You can also synchronize an NI 5105 with other analog and digital instruments to create mixed-signal test systems. An NI 5105 is ideal for a wide range of applications including ultrasonic nondestructive test (NDT), medical imaging, scientific research, military/aerospace, and consumer electronics. Applications Imaging Ultrasonic nondestructive test Optical coherence tomography Medical imaging Aerospace/Defense RADAR, SONAR, and LIDAR Satellite Signal intelligence Consumer Electronics DVD, DVD-R, and PVR Set-top box Gaming console Communications xDSL Eight 60 MS/s, 12-Bit Input Channels for Time and Frequency Analysis • 60 MHz input bandwidth with antialias and noise filters • >72 dBc spurious-free dynamic range (SFDR) • Independent channel-selectable 50 mVpp to 30 Vpp input ranges • Independent channel-selectable 50 Ω or 1 MΩ input impedance • 2-year calibration interval and 0 to 55 °C operating temperature Deep Onboard Memory • 16, 128, or 512 MB of onboard memory • Capture more than 1 million triggered waveforms in multiple record mode, with hardware trigger rearming • Stream data continuously from onboard memory to host memory or disk Triggering, Clocking, and Synchronization • Edge, window, hysteresis, and digital triggering • Pretrigger and posttrigger acquisition in single- and multiple-record mode • Internal 60 MHz clock or external clock from 4 to 65 MHz • Phase lock to PXI 10 MHz reference or external reference from 1 to 20 MHz • Timestamp-triggered events with 100 ps resolution Software • IVI-compliant NI-SCOPE driver for NI LabVIEW and LabWindows/CVI as well as Microsoft C++ and Visual Basic with more than 50 built-in measurements • Scope Soft Front Panel for interactive control Ordering Information NI PXI-5105 ........................................................................779685-0M1 NI PCI-5105 ........................................................................779686-0M1 1M (onboard memory): 1 (16 MB), 2 (128 MB), 3 (512 MB) Includes NI-SCOPE driver and Scope Soft Front Panel. Recommended PXI Switch NI PXI-2593 (500 MHz mux/matrix) ......................................778793-01 BUY NOW! For complete product specifications, pricing, and accessory information, call 800 813 3693 (U.S.) or go to ni.com/digitizers. 60 MS/s, 60 MHz, 12-Bit, 8-Channel Digitizers Specifications These specifications are valid for 0 to 55 °C‚ unless otherwise stated. Acquisition System Number of channels............................ 8 simultaneously sampled Vertical resolution............................... 12 bits Bandwidth (-3 dB) 50 Ω 60 MHz 55 MHz Full-Scale Input Range All except 50 mV 50 mV Bandwidth limit filters (software selectable) .......................... Maximum sample rate........................ Onboard sample memory.................... Multirecord mode Maximum number of records ......... 1 MΩ 60 MHz 35 MHz 24 MHz antialias 60 MS/s real-time 16, 128, or 512 MB 1 MΩ 50 mV range: ±(1% of input + 0.25% of FS + 600 µV) 200 mV, 1 V, and 6 V ranges: ±(0.65% of input + 0.25% of FS + 600 µV) 30 V range: ±(0.75% of input + 0.25% of FS + 600 µV) Channel-to-channel crosstalk ............. ≤-80 dB at 1 MHz Spectral Characteristics (typical) Dynamic performance (50 Ω input impedance with 10 MHz, -1 dBFS input signal) THD (dBc) -75 -75 -75 -75 THD (dBc) -72 -75 -65 -68 SINAD (dB) 50 59 61 59 SINAD = Signal-to-noise and distortion DC accuracy (0 V offset setting) SFDR (dBc) – 72 72 72 SFDR (dBc) – 70 65 65 THD = Total harmonic distortion Accuracy Full-Scale Input Range 50 mV 200 mV 1V 6V Full-Scale Input Range 50 mV 200 mV 1V 6V SFDR = Spurious-free dynamic range Onboard memory/(512 B x number of enabled channels) Input impedance ................................. 50 Ω and 1 MΩ || 50 pF, software selectable Full-scale input range 50 Ω................................................ 50 mV, 200 mV, 1 V, 6 V 1 MΩ .............................................. 50 mV, 200 mV, 1 V, 6 V, 30 V Maximum input overload 50 Ω ............................................... 7 Vrms with | peaks | ≤10 V 1 MΩ .............................................. | peaks | ≤42 V Input coupling ..................................... AC, DC (AC coupling on 1 MΩ only) AC coupling cutoff frequency (-3 dB).. 12 Hz 50 Ω All ranges: ±(1% of input + 0.25% of FS + 600 µV) Dynamic performance (1 MΩ input impedance with 10 MHz, -1 dBFS input signal) SINAD (dB) 59 62 62 62 RMS Noise (24 MHz filter enabled) Full-Scale Input Range 50 mV 200 mV 1V 6V 30 V (1 MΩ only) 50 Ω 19 µVrms 56 µVrms 290 µVrms 1.68 mVrms – 1 MΩ 60 µVrms 72 µVrms 300 µVrms 2.16 mVrms 9 mVrms Timebase System Timebase options................................ Internal, PXI star, external (PFI 1) Internal Internal sample clock frequency ........ 60 MS/s sampling rate with decimation by n where 1 ≤ n ≤ 65,535 Timebase accuracy.............................. ±25 ppm (±0.0025%) External External clock range............................ 8 to 65 MHz, variable with decimation by n where 1 ≤ n ≤ 65,535 External reference sources ................. PFI 1 (SMB connector), PXI backplane 10 MHz External reference range .................... 1 to 20 MHz in 1 MHz increments External clock/reference amplitude.... Sine wave: 0.65 to 2.8 Vpp (0 to 13 dBm) Square wave: 0.2 to 2.8 Vpp External clock/reference impedance .. 50 Ω, AC coupled Trigger System Modes ................................................. Edge, hysteresis, window, digital, immediate, software Sources................................................ CH 0 to CH 7, PXI_Trig <0..6>, PFI 1, PXI star, software Slope ................................................... Rising or falling Hysteresis............................................ Fully programmable Sensitivity............................................ 2% FS BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) 2 60 MS/s, 60 MHz, 12-Bit, 8-Channel Digitizers Intermodule SMC Synchronization Using NI-TClk (typical) Skew.................................................... 500 ps <10 ps after manual adjustment Power Requirements (typical) PXI PCI +3.3 VDC 1.5 A 1.7 A +5 VDC 1.7 A 2A +12 VDC 200 mA 20 mA -12 VDC 25 mA OA Total Power 16.15 W 15.85 W Environment Operating temperature1 ...................... 0 to 55 °C (meets IEC-60068-2-1 and IEC-60068-2-2) Storage temperature........................... -40 to 70 °C (meets IEC-60068-2-1 and IEC-60068-2-2) Relative humidity ................................ 10 to 90%, noncondensing (meets IEC-60068-2-56) 10 to 45 °C in PXI-101x and 1000/B chassis. For access to certifications, marks, and DoCs, visit ni.com/certification. BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) 3 NI Services and Support NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. Professional Services Our NI Professional Services team is composed of NI applications and systems engineers and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. OEM Support We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. ni.com • 800 813 3693 National Instruments • [email protected] Local Sales and Technical Support In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. Hardware Services NI Factory Installation Services NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor. Calibration Services NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. Repair and Extended Warranty NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. *351444B-01* 351444B-01 2006-7317-101-D © 2007 National Instruments Corporation. All rights reserved. CVI, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com, SCXI, and SignalExpress are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency, partnership, or joint-venture relationship with National Instruments.