NI NIPCI-5114

250 MS/s, 125 MHz, 8-Bit Digitizers
NI 5114 NEW!
•
•
•
•
•
•
•
250 MS/s real-time sampling
5 GS/s random-interleaved sampling
8-bit resolution
125 MHz bandwidth
40 mVpp to 40 Vpp input range
8, 64, or 256 MB memory per channel
Edge, window, hysteresis, video, and
digital triggering with 40 ps timestamping
Calibration
• Gain, offset, compensated 1 MΩ
attenuator, and timing self-calibration
• 2-year external calibration interval
Operating Systems
• Windows Vista/XP/2000
• LabVIEW Real-Time
Recommended Software
•
•
•
•
LabVIEW
LabWindows™/CVI
Measurement Studio for Visual Studio
LabVIEW SignalExpress
Driver Software (included)
• NI-SCOPE Soft Front Panel and driver
• LabVIEW Express VIs
>> For complete specifications, see the NI 5114 Specifications manual at ni.com/manuals.
Overview
Applications
Aerospace/Defense
RADAR, SONAR, and LIDAR
Satellite
Signal intelligence
Biomedical and Scientific Research
Ultrasonic medical imaging
Mass spectrometry
Particle physics
Communications
xDSL
Wireless communications
Baseband I & Q
National Instruments PXI-5114 and
PCI-5114 high-speed digitizers feature
two 250 MS/s simultaneously sampled
input channels with 8-bit resolution,
125 MHz bandwidth, and up to 256 MB of
memory per channel in a compact, 3U PXI or
PCI device. With the National Instruments
Synchronization and Memory Core (SMC)
architecture of an NI 5114, you can create mixed-signal systems using
signal generators and digital waveform generator/analyzers or build a
high-channel-count digitizer with subnanosecond synchronization
between channels. An NI 5114 is ideal for a wide range of application
areas including communications, scientific applications,
military/aerospace, and consumer electronics.
Dual 250 MS/s, 8-Bit Input Channels
• 125 MHz input bandwidth with noise filters
• 5 GS/s equivalent-time sampling (ETS) for repetitive signals
• Independent channel-selectable 40 mVpp to 40 Vpp input ranges
• Independent channel-selectable 50 Ω or 1 MΩ input impedance
• 2-year calibration interval and 0 to 55 °C operating temperature
Deep Onboard Memory
• 8, 64, or 256 MB of memory per channel
• Capture more than 1 million triggered waveforms in multiple record
mode with hardware trigger rearming
• Stream data continuously from onboard memory to host
memory or disk
Triggering, Clocking, and Synchronization
• Edge, window, hysteresis, and digital triggering with 40 ps timestamping
• Pretrigger and posttrigger acquisition in single- and multiple-record mode
• Internal 250 MHz clock or external clock from 50 to 250 MHz
• Phase lock to PXI 10 MHz reference or external reference from
1 to 20 MHz
• Timestamp-triggered events with 100 ps resolution
Software
• IVI-compliant NI-SCOPE driver for NI LabVIEW and LabWindows/CVI
as well as Microsoft C++ and Visual Basic with more than 50
built-in measurements
• NI-SCOPE Soft Front Panel for interactive control
Ordering Information
NI PXI-5114 ........................................................................779466-0M1
NI PCI-5114 ........................................................................779745-0M1
1M
(memory per channel): 1 (8 MB), 2 (64 MB), 3 (256 MB)
Includes NI-SCOPE Soft Front Panel and driver.
Recommended PXI Switch
NI PXI-2593 (500 MHz mux/matrix) ......................................778793-01
BUY NOW!
For complete product specifications, pricing, and accessory
information, call 800 813 3693 (U.S.) or go to ni.com/digitizers.
250 MS/s, 125 MHz, 8-Bit Digitizers
Spectral Characteristics (typical)
Specifications
Dynamic performance (10 MHz, -1 dBFS input signal)
These specifications are valid for 0 to 55 °C, unless otherwise stated.
Acquisition System
Number of channels............................ 2 simultaneously sampled
Vertical resolution............................... 8 bits
Bandwidth (-3 dB)
Range (Vpp)
All except 0.04
0.04
Minimum Bandwidth
125 MHz
100 MHz
Bandwidth limit filters
(software-selectable) ......................... 20 MHz noise filter
Maximum sampling rate..................... 250 MS/s real-time sampling,
5 GS/s equivalent-time/
random-interleaved sampling
Onboard sample memory.................... 8, 64, or 256 MB per channel
(8, 64, or 256 million samples)
Multiple Record Acquisition (0 to 100% pretrigger and posttrigger data)
Memory/Channel
Maximum Number of Records
8 MB
32,768
64 MB
100,0001
256 MB
100,0001
1Infinite
in streaming configuration.
Input impedance ................................. 50 Ω and 1 MΩ || 26 pF,
software-selectable
Full-Scale Input Range and Programmable Vertical Offset
50 Ω
1 MΩ
Range
Vertical Offset
Range
Vertical Offset
(Vpp)
Range (V)
(Vpp)
Range (V)
0.04
0.1
0.2
0.4
1.0
2.0
4.0
10
–
–
±0.8
±0.8
±0.8
±0.8
±6.5
±6.0
±5.0
±2.0
–
–
0.04
0.1
0.2
0.4
1.0
2.0
4.0
10
20
40
±0.8
±0.8
±0.8
±0.8
±8.0
±8.0
±8.0
±30
±25
±15
Maximum input overload.................... 50 Ω: 7 Vrms with | peaks |
≤10 V; 1 MΩ: | peaks | ≤35 V
Input coupling ..................................... AC, DC, GND – AC coupling
available on 1 MΩ only
AC coupling cutoff frequency (-3 dB).. 12 Hz (1 MΩ)
Accuracy
DC accuracy (0 V offset setting) ......... ±(1.5% of input +0.3% of
FS + 200 µV) for PXI-5114
±(1.5% of input +0.3% of
FS + 280 µV) for PCI-5114
Channel-to-channel crosstalk ............. -60 dB at 10 MHz
SFDR
THD
ENOB
SINAD
Range (Vpp)
All Ranges Except 0.04
58 dBc
-58 dBc
7.2
44 dB
0.04
58 dBc
-58 dBc
6.2
38 dB
RMS Noise
20 MHz filter enabled ......................... 0.28% of FS
Timebase System
Timebase options................................ Internal, external (CLK IN)
Internal
Internal sample clock frequency ........ 250 MS/s sampling rate with
decimation by n, 1 ≤ n ≤ 65,535
Timebase accuracy.............................. ±25 ppm (±0.0025%)
External
External clock sources ........................ CLK IN (SMB connector)
External clock range............................ 50 to 250 MHz with
decimation by n where
1 ≤ n ≤ 65,535
External reference sources ................. CLK IN (SMB connector),
PXI_CLK10 (PXI backplane 10 MHz)
External reference range .................... 1 to 20 MHz in 1 MHz increments
External clock/reference amplitude.... Sine wave: 0.65 to 2.8 Vpp
(0 to 13 dBm)
Square wave: 0.2 to 2.8 Vpp
External clock/reference impedance .. 50 Ω, AC coupled
Trigger System
Modes ................................................. Edge, hysteresis, window, video,
digital, immediate, software
Sources................................................ CH 0, CH 1, TRIG, PXI_Trig
<0..6>, PXI star, software
Slope ................................................... Rising or falling
Hysteresis............................................ Fully programmable
High-frequency reject filter................. 50 kHz software-selectable
Low-frequency reject filter ................. 50 kHz software-selectable
Sensitivity
CH 0 and CH 1 ................................ 5% FS
TRIG ................................................ 0.5 Vpp
Level accuracy
CH 0, CH 1 ...................................... ±5% FS up to 10 MHz
TRIG ................................................ ±0.5 V up to 10 MHz
Time resolution ................................... 40 ps with time-to-digital
converter enabled
Rearm time1 ........................................ 2 µs
Holdoff1 ............................................... From 2 µs to [(235-1) x
(sample clock period)],
software-selectable
1Time-to-digital
converter disabled.
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
2
250 MS/s, 125 MHz, 8-Bit Digitizers
External Trigger Channel (TRIG)
Safety and Compliance
Impedance........................................... 1 MΩ || 22 pF
Vertical range...................................... ±5 V
Coupling .............................................. AC, DC
Safety
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control,
and laboratory use:
Intermodule SMC Synchronization Using
NI-TClk (typical)
Skew.................................................... 500 ps
≤20 ps after manual adjustment
Power Requirements (typical)
PXI
PCI
+3.3 VDC
840 mA
1.6 A
+5 VDC
1.1 A
1.7 A
+12 VDC
250 mA
45 mA
-12 VDC
170 mA
0A
Total Power
13.32 W
14.32 W
Environment
Operating temperature2 ...................... 0 to 55 °C for PXI-5114,
0 to 45 °C for PCI-5114
(meets IEC-60068-2-1 and
IEC-60068-2-2)
Storage temperature........................... -40 to 71 °C (meets
IEC-60068-2-1 and IEC-60068-2-2)
Relative humidity ................................ 10 to 90%, noncondensing
(meets IEC-60068-2-56)
20
to 45 °C in PXI-101x or PXI-1000/B chassis.
Calibration
Self-calibration.................................... Gain, offset, compensated
1 MΩ attenuator, triggering,
and timing for all input ranges
External calibration interval................ 2 years
• IEC 61010-1, EN 61010-1
• UL 61010-1, CSA 61010-1
Note: For UL and other safety certifications, refer to the product label or
visit ni.com/certification, search by model number or product line, and
click the appropriate link in the Certification column.
Electromagnetic Compatibility
This product is designed to meet the requirements of the following
standards of EMC for electrical equipment for measurement, control,
and laboratory use:
• EN 61326 EMC requirements; Minimum Immunity
• EN 55011 Emissions; Group 1, Class A
• CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A
Note: For EMC compliance, operate this device according to
product documentation.
CE Compliance
This product meets the essential requirements of applicable European
Directives, as amended for CE marking, as follows:
• 2006/95/EC; Low-Voltage Directive (safety)
• 2004/108/EC; Electromagnetic Compatibility Directive (EMC)
Note: Refer to the Declaration of Conformity (DoC) for this product for
any additional regulatory compliance information. To obtain the DoC for
this product, visit ni.com/certification, search by model number or
product line, and click the appropriate link in the Certification column.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers: At the end of their life cycle, all products must be
sent to a WEEE recycling center. For more information about WEEE
recycling centers and National Instruments WEEE initiatives,
visit ni.com/environment/weee.htm.
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
3
NI Services and Support
NI has the services and support to meet
your needs around the globe and through
the application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
that identifies individuals who have high levels of skill and knowledge on
using NI products. Visit ni.com/training.
Professional Services
Our NI Professional Services team is composed of NI applications
and systems engineers and a worldwide National Instruments Alliance
Partner program of more than 600 independent consultants and
integrators. Services range
from start-up assistance to
turnkey system integration.
Visit ni.com/alliance.
OEM Support
We offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
ni.com • 800 813 3693
Local Sales and Technical Support
In offices worldwide, our staff is local to the country, giving you access
to engineers who speak your language. NI delivers industry-leading
technical support through online knowledge bases, our applications
engineers, and access to 14,000 measurement and automation
professionals within NI Developer Exchange forums. Find immediate
answers to your questions at ni.com/support.
We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of technical
support. Visit ni.com/ssp.
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
Trained NI technicians install the software and hardware and configure
the system to your specifications. NI extends the standard warranty by
one year on hardware components (controllers, chassis, modules)
purchased with FIS. To use FIS, simply configure your system online
with ni.com/pxiadvisor.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
*351544A-01*
351544A-01
2007-9252-101-D
© 2007 National Instruments Corporation. All rights reserved. CVI, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com,
SCXI, and SignalExpress are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Other product and company names listed
are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency,
partnership, or joint-venture relationship with National Instruments.