ORIONFANS OA125AP-11/22-2W

77282 2009_fan_cat sec 1:Layout 1
8/3/09
8:57 AM
Page 9
OA125 Series
AC Fan - 115V, 230V, Dual Voltage
120 x 25mm (4.7” x 1.0”)
119.5±0.5
(4.70")
(1.03")
A TI O N
OT
104.8±0.3
(4.13")
(4.13")
R
Frame
Impeller
Connection
Diecast Aluminum
PBT, UL94V-O plastic
2x Lead Wires 22 AWG or
terminals
Operating Temperature
Ball Bearing
-20C ~ +80C
Sleeve Bearing
-10C ~ +50C
Shaded pole, impedance
protected
Tachometer available
(5VTTL), input 5 ~24V
Life Expectancy
Ball Bearing
60,000 hours (L10 at 40C)
Insulation Resistance
>100M ohm between leadwire and frame (500VDC)
Dielectric Strength
1 min at 1500 VAC, 50/60Hz
Dual Voltage
Connection via 4x leads.
Fans can be configured for
115V or 230V operation.
Motor
Bearing System
Sleeve Bearing
30,000 hours (L10 at 40C)
Dual ball or Sleeve
Model Number
119.5±0.5
4.2±.2 (.166") DIA.
HOLE THRU
TYP. 8 PLACES
104.8±0.3
(4.70")
26.2±0.5
m0
Speed (RPM) Airflow (CFM)
Noise (dB)
Volts AC
Voltage
Range
Watts
Max. Static
Pressure (“H2O)
OA125AP-11-1*
OA125AP-11-2*
OA125AP-11-3*
OA125AP-22-1*
OA125AP-22-2*
OA125AP-22-3*
2900
2300
1600
2900
2300
1600
81
60
42
81
60
42
33
27
22
32
27
22
115
115
115
230
230
230
80~130
80~130
80~130
160~260
160~260
160~260
13
10
6
13
10
6
.23
.18
.12
.23
.18
.12
OA125AP-11/22-1W**
OA125AP-11/22-2W**
OA125AP-11/22-3W**
2900
2300
1600
81
60
42
32
27
22
115/230
115/230
115/230
80~260
80~260
80~260
13
10
6
.23
.18
.12
* Indicate “TB” (Terminal Ball Bearing), “WB” (12” Wire Leads, Ball Bearing), “TS” (Terminal, Sleeve Bearing), “WS” (12” Wire Leads, Sleeve Bearing)
** Indicate “B” (Ball Bearing) or “S” (Sleeve Bearing)
Frame Style - m0
Knight Electronics, Inc.
10557 Metric Drive
Dallas, Texas 75243
214-340-0265
Orion Fans
RoHS Compliant
9
Information and data is subject to
change without prior notification.