PARAMETER UNITS 100 WATT TURNS S1,S2 = 10 turns, AWG 22 (Bifilar) S3 = 4 turns, AWG 28 S4 = 3 turns, AWG 28 S5 = 35 turns, AWG 28 S6 = 35 turns AWG 28 FORWARD CONVERTER TRANSFORMER Schematic Diagram Isolation (min) S1 to S2 Isolation (min) S1 & S2 to S3 600 VRMS PRI SEC 12 1 600 Isolation (min) S4 to S5 & S6 600 Isolation (min) S5 to S6 1500 Isolation (min) S1 & S2 &S3 to S4 & S5 & S6 1500 VRMS 2 3 VRMS VRMS S1 S6 10 S2 S5 4 5 VRMS 9 8 S3 S4 7 6 Manufactured with UL rated materials. Wire rated at 155o minimum 11 Physical Dimensions inches (mm) Rhombus P/N: Cust. P/N: Date: 1/14/96 Rhombus Industries Inc. Transformers & Magnetic Products T-1038 Name: Sheet: 1 of 1 15801 Chemical Lane, Huntington Beach, CA 92649-1595 Phone: (714) 898-0960 z FAX: (714) 896-0971 www.rhombus-ind.com