RHOMBUS-IND T

T1/CEPT PULSE TRANSFORMER
Turns Ratio ( + 5% )
PARAMETER
1:0.5:0.5
MIN.
MAX.
UNITS
1
Open Circuit Inductance
1
Primary Leakage Inductance
0.3
µHy
1
Secondary Leakage Inductance
0.4
µHy
1
Interwinding Capacitance (CW/W)
18
pF
Primary DC Resistance
0.7
ohms
Secondary DC Resistance
0.5
ohms
1.5
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
mHy
Isolation (HI-POT)
1.5 Kv
VRMS
E.T.
16
V-µS
Temperature Characteristics:
-40o C 900 µH min. (40% drop in
inductance)
+85o C 1.7 mH min. (15% growth in
inductance)
Typical part:
2.0 mH @ +25o C
2.3 mH @ +85o C
1.2 mH @ -40o C
Parts shipped in anti-static
tubes. 44 pieces per tube
Tape & Reel
Available
*Primary Pins 5-6. A center tap
can be formed by shorting pins
1+4 creating a 1:1CT Transformer.
1
Tested at 772 kHz & 100 mV
PHYSICAL DIMENSIONS
All dimensions in inches (mm):
SCHEMATIC DIAGRAM:
RHOMBUS INDUSTRIES INC.
FSCM NO. 16714
RHOMBUS P/N: T-10321
CUST P/N:
11/04/97
DATE:
Rhombus
Industries Inc.
Transformers & Magnetic Products
NAME:
SHEET:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971