10222

T1/CEPT/ISDN PRI INTERFACE TRANSFORMER
UL 1459 Recognized
Turns Ratio ( + 5% )
PARAMETER
*1:0.633:0.633
MIN.
1Open Circuit Inductance
MAX.
1.5
UNITS
mHy
1Primary Leakage Inductance
0.3
µHy
1Secondary Leakage Inductance
0.4
µHy
1Interwinding Capacitance (C
W/W)
18
pF
Primary DC Resistance
0.7
ohms
Secondary DC Resistance
0.5
ohms
Isolation (HI-POT)
1.5 Kv
VRMS
E.T.
16
V-µS
*Primary Pins 5-6. A center tap can be
formed by shorting pins 1+4 creating a
1:1.26CT Transformer
1
R
Temperature Characteristics:
-40o C 900 µH min. (40% drop in
inductance)
+85o C 1.7 mH min. (15% growth in
inductance)
Typical part:
2.0 mH @ +25o C
2.3 mH @ +85o C
1.2 mH @ -40o C
Parts shipped in anti-static
tubes. 50 pieces per tube
PHYSICAL DIMENSIONS
All dimensions in inches (mm):
Tested at 772 kHz & 100 mV
SCHEMATIC DIAGRAM:
RHOMBUS INDUSTRIES INC.
FSCM NO. 16714
RHOMBUS P/N: T-10222
CUST P/N:
11/04/97
DATE:
Rhombus
Industries Inc.
Transformers & Magnetic Products
NAME:
SHEET:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971