RHOMBUS-IND T-1149

Transformer
Turns Ratio ( + 3 % )
4-6/1-2 = 1 : 1
PARAMETER
MIN.
Primary Inductance1
600
TYP.
MAX.
Schematic Diagram
UNITS
µH
Secondary
Pins 1-2.
Leakage Inductance 2
Interwinding Capacitance 3
Primary DC Resistance
0.6
0.75
µH
27
pF
Primary
1
4
5
ohms
Pins 1-2
2
Secondary DC Resistance
0.6
6
ohms
Pins 4-5 or 5-6.
Isolation (Hi-Pot) 4-1 to 4-6
Insulation Resistance
2500
VRMS
10
MΩ
Longitudinal Balance
0.6
ohms
@ 1.544 MHz 4
1. Tested @ 1kHz & 500 mVRMS
2. Tested @ 10kHz & 100 mVRMS
3. Tested @ 1kHz & 1 VRMS
4. To meet or exceed FCC part 68 requirements
.375
(9.53)
MAX.
.465
(11.81)
MAX.
PIN POSITION GRID 0.098 (2.5)
CLIP SET TERMINATIONS
BOBBIN TERMINATIONS
.394
(10.00)
MAX.
Physical
Dimensions
inches (mm)
.110
(2.79)
MIN.
.098
.024
(2.49) (0.61)
6
5
.080
(2.03)
.039
(0.99)
4
Bottom
View
1
2
3
RHOMBUS P/N: T-1149
CUST P/N:
DATE: 09/29/98
Rhombus
Industries Inc.
Transformers & Magnetic Products
NAME:
SHEET:
1 of 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971
www.rhombus-ind.com