RHOMBUS-IND T

T3 Interface Transformer
Also suitable for DS3, E3 and STS-1 interfaces
Turns Ratio ( + 3% )
1:2CT
PARAMETER
MIN.
Inductance
MAX.
40
UNITS
µHy
Rise Time
3.0
nS
Leakage Inductance
0.14
µHy
Capacitance (CW/W)
15
pF
Primary DC Resistance
0.2
ohms
Flammability: Materials used in
the production of these units
are UL94-VO and meet requirements of IEC 695-2-2 needle
flame test.
Parts shipped in anti-static
tubes. 55 pieces per tube
Tape & Reel Available
Isolation
1500
VRMS
3 dB Bandwidth is .200 - 340 (MHz) typical, tested in a 75 ohm system
Schematic Diagram
Dimensions in inches (mm)
1
6
2
5
3
6
1
5
2
4
3
4
RHOMBUS P/N: T-13104P
CUST P/N:
NAME:
DATE: 4/27/99
SHEET:
Rhombus
Industries Inc.
Transformers & Magnetic Products
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971
www.rhombus-ind.com