SECOS SCS706F

SCS706F
VOLTAGE 40V
Elektronische Bauelemente
0.03AMP Surface Mount Schottky Barrier Rectifiers
RoHS Compliant Product
A suffix of "-C" specifies halogen & lead-free
FEATURES
·
·
·
SOT323
Dim
Low Turn-on Voltage
Min
Max
Fast Switching
A
1.80
2.20
PN Junction Guard Ring for Transient and
ESD Protection
B
1.15
1.35
C
0.80
1.00
D
0.30
0.40
MECHANICAL DATA
G
1.20
1.40
·
·
H
0.00
0.10
·
·
·
Case: SOT-346, Molded Plastic
A
Terminals: Solderable per MIL-STD-202,
Method 208
L
Polarity: See Diagrams Below
Weight: 0.008 grams (approx.)
S
Mounting Position: Any
2
3
Top View
B
1
J
0.10
0.25
K
0.20
0.60
L
0.90
1.10
S
2.00
2.40
All Dimension in mm
D
G
CATHODE
ANODE
J
C
1
3
2
CATHODE
K
H
ANODE
3
SCS706F Marking : 3J
2
1
zAbsolute maximum ratings (Ta = 25°C)
Symbol
Limits
Unit
Peak reverse voltage
Parameter
VRM
45
V
DC reverse voltage
VR
40
V
Mean rectifying current
IO
30
mA
IFSM
200
mA
Peak forward surge current ∗
Junction temperature
Tj
125
°C
Storage temperature
Tstg
−40~+125
°C
∗60 Hz for 1
zElectrical characteristics (Ta = 25°C)
Parameter
Symbol
Min.
Typ.
Max.
Unit
Conditions
Forward voltage
VF
−
−
0.37
V
IF=1mA
Reverse current
IR
−
−
1
µA
VR=10V
Capacitance between terminals
CT
−
5.0
−
pF
VR=1V, f=1MHz
Note) ESD sensitive product handling required.
http://www.SeCoSGmbH.com
01-Jun-2002 Rev. A
Any changing of specification will not be informed individual
Page 1 of 2
SCS706F
VOLTAGE 40V
Elektronische Bauelemente
0.03AMP Surface Mount Schottky Barrier Rectifiers
RATING AND CHARACTERISTIC CURVES (SCS706F)
zElectrical characteristic curves (Ta = 25°C)
1000m
100µ
°C
10m
1m
Ta=25°C
Ta=−25°C
10µ
1µ
0
0.2
0.4
0.6
0.8
1.0
1.2
Ta=25°C
100n
Ta=−25°C
10n
1n
0
1.4
Typ.
pulse measurement
5
10
15
20
25
30
Fig. 1 Forward characteristics
Fig. 2 Reverse characteristics
35
f=1MHz
Ta=25°C
100
20
10
5
80
60
40
20
2
2
4
6
8
10
12
14
REVERSE VOLTAGE : VR (V)
Fig. 3 Capacitance between
terminals characteristics
01-Jun-2002 Rev. A
1µ
REVERSE VOLTAGE : VR (V)
50
http://www.SeCoSGmbH.com
Ta=75°C
FORWARD VOLTAGE : VF (V)
100
1
0
10µ
Io CURRENT (%)
CAPACITANCE BETWEEN TERMINALS : CT (pF)
Ta=75°C
100µ
Ta=125°C
REVERSE CURRENT : IR (A)
100m
Ta
=1
25
FORWARD CURRENT : IF (A)
Typ.
pulse measurement
0
25
50
75
100
125
AMBIENT TEMPERATURE : Ta(°C)
Fig 4. Derating curve
(mounting on glass epoxy PCBs)
Any changing of specification will not be informed individual
Page 2 of 2