SEME-LAB LM79M05AJX

LM79M05AHX
LM79M05AJX
MECHANICAL DATA
5 VOLT NEGATIVE
VOLTAGE REGULATOR
8 .8 9 (0 .3 5 )
9 .4 0 (0 .3 7 )
5 .0 8 (0 .2 0 0 )
ty p .
7 .7 5 (0 .3 0 5 )
8 .5 1 (0 .3 3 5 )
4 .1 9 (0 .1 6 5 )
4 .9 5 (0 .1 9 5 )
2 .5 4
(0 .1 0 0 )
!
FEATURES
0 .6 6 (0 .0 2 6 )
1 .1 4 (0 .0 4 5 )
• 0.01%/V LINE REGULATION
0 .7 1 (0 .0 2 8 )
0 .8 6 (0 .0 3 4 )
0 .8 9 m a x .
(0 .0 3 5 )
1 2 .7 0
(0 .5 0 0 )
m in .
7 .7 5 (0 .3 0 5 )
8 .5 1 (0 .3 3 5 )
d ia .
• 0.3%/A LOAD REGULATION
4 5 °
• THERMAL OVERLOAD PROTECTION
H Package - TO-39 Metal
Pin 1 = Ground
Pin 2 = Vout
Pin 3 = Vin
• SAFE OPERATING AREA PROTECTION
0.45 7 ± 0 .102
(0 .0 18 ± 0.00 4)
8
5
1
4
• 2% OUTPUT VOLTAGE TOLERANCE
DESCRIPTION
1.42 2 ± 0.102
(0 . 056 ± 0.00 4)
7.899
(0.311)
4 .013 ± 0.4 06
(0.1 58 ± 0.016)
10.287 ± 0 .5 08
(0.4 05 ± 0 .0 20)
The LM79M05AH and LM79M05AJ are 5V negative
0.5A Voltage Regulators providing 0.01% per Volt Line
Regulation and 0.3% per amp load regulation.
7.239 ± 0.305
(0.285 ± 0.012)
5 .08
(0.2 00)
Ma x.
1.52 4 (0.060) Ma x.
0 .38 1 (0.01 5) Min .
8.255 ± 0 .6 35
(0 .3 25 ± 0.025 )
• SHORT CIRCUIT PROTECTION
Protection includes safe operating Area current limiting
and thermal.
4 .064
(0.1 60)
Min.
0.914
(0.036)
0.27 9 ± 0 .0 51
(0 .011 ± 0.002)
9.525 ± 0 .635
(0.3 75 ± 0.0 25)
3.68 3 ± 0.508
(0.1 45 ± 0.020)
2.54
(0.100)
2˚ to 1 3˚
REF
* Lead Thickness for tin plate finish only.
Solder dip finish adds 2 to 10 mil thickness to all lead tip dimensions.
J Package = 8 Pin Ceramic DIP
Pin 1 = Ground
Pin 5 = N/C
Pin 2 = N/C
Pin 6 = Vin
Pin 3 = N/C
Pin 7 = N/C
Pin 4 = Vout
Pin 8 = N/C
ABSOLUTE MAXIMUM RATINGS (Tcase = 25°C unless otherwise stated)
VI
PD
Tj
Tstg
TL
Semelab plc.
DC Input Voltage
VO = -5V
Power Dissipation
Operating Junction Temperature Range
Maximum Junction Temperature
Storage Temperature Range
Lead Temperature (Soldering, 10 sec)
Telephone +44(0)1455) 556565. Fax +44(0)1455) 552612.
E-mail: [email protected]
Website: http://www.semelab.co.uk
35V
Internally limited
–55°C to +125°C
125°C
–65°C to +150°C
300°C
1/01
LM79M05AHX
LM79M05AJX
ELECTRICAL CHARACTERISTICS (Tj = 25°C unless stated)
Parameter
VO
Output Voltage*
Test Conditions
IO = 100mA
VIN = -10V
Min.
- 4.9
IO = 5mA to 350mA
PD £ PMAX
- 4.8
Tj = –55 to +125°C
DIQ Quiescent Current Change*
VN
Output Noise Voltage
DVIN
Ripple Rejection
DVO
- 5.2
V
(VIN = -7 to -25V)
mV
50
IO = 500mA
Quiescent Current*
Unit
100
DVO Line Regulation*
Id
Max.
- 5.1
(VIN = -8 to -20V)
IO = 500mA
DVO Load Regulation*
Typ.
-5
(VIN = -8 to -12V)
IO = 5mA to 500mA
VIN = -10V
100
mV
IO = 350mA
VIN = -10V
3
mA
IO = 5 to 500 mA
VIN = -10V
0.5
mA
Tj = –55 to +125°C
IO = 500mA
1.3
Tj = –55 to +125°C
(VIN = -8 to -12V)
f = 10Hz to 100kHz
100
f = 120Hz
IO = 500mA
Tj = –55 to +125°C
54
mA
mV
60
dB
(VIN = -10)
Dropout Voltage*
IO = 500mA
1.4
V
ISC
Short Circuit Current*
VIN = -10V
2.1
A
IPK
Peak Output Current*
VIN = -10V
2.5
A
Average Temperature
IO = 5mA
-0.4
Coefficient of Output Voltage* Tj = –55 to +125°C
* Pulse Test:
mV
/ °C
tp £ 10ms , d £ 5%.
All characteristics are measured with a capacitor across the input of 0.22mF and a capacitor across the output of 0.1mF.
Output Voltage changes due to changes in internal temperature must be taken into account separately.
Although power dissipation is internally limited, these specifications apply for up to 2W for the TO–39 package, and
1.05W for the CERDIP (J package).
THERMAL DATA
RTHj-case
Thermal Resistance Junction – Case
TO-39 (H Package)
RTHj-amb
Thermal Resistance Junction – Ambient
CERDIP (J Package)
120°C / W Typ.
Derate above 25°C
CERDIP (J Package)
8.4 mW / °C
Semelab plc.
Telephone +44(0)1455) 556565. Fax +44(0)1455) 552612.
E-mail: [email protected]
Website: http://www.semelab.co.uk
20°C / W Typ.
1/01