DATA SHEET SKY13286-359LF: 0.1-6.0 GHz High Isolation SPDT Absorptive Switch Applications • GSM, PCS, WCDMA base stations • 2.4 and 5.8 GHz ISM devices • Wireless local loops CBL J1 50 CBL Features RFC • Single, positive voltage control: 0 to 3 and 0 to 5 V • High isolation 64 dB at 1 GHz and 2 GHz • Integrated silicon CMOS driver • Absorptive 50 CBL J2 • Small, QFN (16-pin, 4 x 4 mm) Pb-free package (MSL1, 260 °C per JEDEC J-STD-020) Decoder VDD Skyworks offers lead (Pb)-free, RoHS (Restriction of Hazardous Substances) compliant packaging. VCTL S1595 Figure 1. SKY13286-359LF Block Diagram Description The SKY13286-359LF is a GaAs pHEMT FET high-isolation, absorptive switch. The device is an ideal component for base station applications in which synthesizer isolation is critical. The device is provided in a 4 x 4 mm, 16-pin Quad Flat No-Lead (QFN) package. A functional block diagram is shown in Figure 1. The pin configuration and package are shown in Figure 2. Signal pin assignments and functional pin descriptions are provided in Table 1. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 200570E • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • July 30, 2009 1 GND GND GND GND DATA SHEET • SKY13286-359LF SPDT ABSORPTIVE SWITCH 16 15 14 13 VCTL 2 11 GND RFC 3 10 GND GND 4 9 J2 5 6 7 8 GND J1 GND 12 GND 1 GND VDD Figure 2. SKY13286-359LF Pinout – 16-Pin QFN (Top View) Table 1. SKY13286-359LF Signal Descriptions Pin # Name Description Pin # Name Description 1 VDD DC power supply 9 J2 RF output 2 2 VCTL DC switch control pin. Switches insertion loss state from RFC to J1 or J2 (see Table 5). 10 GND Ground 3 RFC RF input 11 GND Ground 4 GND Ground 12 J1 RF output 1 5 GND Ground 13 GND Ground 6 GND Ground 14 GND Ground 7 GND Ground 15 GND Ground 8 GND Ground 16 GND Ground Electrical and Mechanical Specifications The absolute maximum ratings of the SKY13286-359LF are provided in Table 2. Recommended operating conditions are specified in Table 3 and electrical specifications are provided in Table 4. Typical performance characteristics of the SKY13286-359LF are illustrated in Figures 3 through 9. The state of the SKY13286-359LF is determined by the logic provided in Table 5. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 2 July 30, 2009 • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • 200570E DATA SHEET • SKY13286-359LF SPDT ABSORPTIVE SWITCH Table 2. SKY13286-359LF Absolute Maximum Ratings Parameter Symbol Minimum Typical Maximum Units 5.5 V Supply voltage VDD RF input power @ >500 MHz VI Operating temperature TOP –40 +95 °C Storage temperature TSTG –65 +150 °C Note: 2.7 1 W Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device. CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times. Table 3. Recommended Operating Conditions Parameter Symbol Switching characteristics: Rise, fall On/off Video feedthrough Test Condition 10/90% or 90/10% RF 50% control to 90/10% RF TRISE = 3 ns, measurement bandwidth = 500 MHz Input power for 1 dB compression PINPUT VDD = 3V, 0.7-2.0 GHz VDD = 5 V, 0.7-2.0 GHz 3rd Order Intercept Point IP3 For 2-tone input power, +8 dBm/tone, 1 MHz spacing: VDD = 3.3 V, 0.7-1.0 GHz VDD = 5.0 V, 0.7-1.0 GHz VDD = 3.3 V, 1.0-2.0 GHz VDD = 5.0 V, 1.0-2.0 GHz Control voltage (Note 1): Low High VCTL_LOW VCTL_HIGH Typical VDD = 5 V Control current VCTL = low or high Max +26 +45 +45 25 mV +23 +30 dBm dBm +49 +47 +43 +46 dBm dBm dBm dBm 0.5 VDD V V 100 μA μA 5 2.7 Units ns ns 30 50 0 2.7 Supply current Supply voltage Min 5.0 V Note 1: VDD must be applied before a VCTL high signal. A latch-up condition may occur if a logic high signal is applied before the VDD voltage. Control voltages switch the VDD voltage to the GaAs switch. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 200570E • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • July 30, 2009 3 DATA SHEET • SKY13286-359LF SPDT ABSORPTIVE SWITCH Table 4. SKY13286-359LF Electrical Specifications (Note 1) (VCTL = 0 V/3 V, VDD = 5 V, TOP = +25 °C, PINPUT = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Parameter Symbol Test Condition Min Typical Max Units 0.8 0.8 1.0 1.5 1.10 1.25 1.35 1.80 dB dB dB dB Insertion loss 0.1 to 2.0 GHz 2.0 to 3.0 GHz 3.0 to 4.0 GHz 4.0 to 6.0 GHz Isolation 0.1 to 2.0 GHz 2.0 to 3.0 GHz 3.0 to 4.0 GHz 4.0 to 6.0 GHz 60 58 55 40 62 62 58 42 dB dB dB dB Return loss (insertion loss state) (Note 2) 0.1 to 2.0 GHz 2.0 to 3.0 GHz 3.0 to 4.0 GHz 4.0 to 6.0 GHz 10 15 13 10 22 22 18 12 dB dB dB dB Return loss (isolation state) (Note 2) 0.1 to 2.0 GHz 2.0 to 3.0 GHz 3.0 to 4.0 GHz 4.0 to 6.0 GHz 10 12 12 11 12 15 15 13 dB dB dB dB Note 1: Performance is guaranteed only under the conditions listed in this Table and is not guaranteed over the full operating or storage temperature ranges. Operation at elevated temperatures may reduce reliability of the device. Note 2: Lower frequency return loss is dependent on DC blocks. Typical Performance Characteristics (VCTL = 0 V/3 V, VDD = 5 V, TOP = +25 °C, PINPUT = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) 0 0 –0.5 –10 J1 J2 –20 –1.5 Isolation (dB) Insertion Loss (dB) –1.0 –2.0 –2.5 –3.0 –30 –40 –50 –3.5 –60 –4.0 J1 J2 –4.5 –70 –5.0 –80 0 1 2 3 4 Frequency (GHz) Figure 3. Insertion Loss vs Frequency 5 6 0 1 2 3 4 Frequency (GHz) Figure 4. Isolation v s Frequency Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 4 July 30, 2009 • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • 200570E 5 6 DATA SHEET • SKY13286-359LF SPDT ABSORPTIVE SWITCH 0 0 J1 |S11| J2 |S11| J1 |S22| J2 |S22| –5 –5 Return Loss (dB) Return Loss (dB) –10 –15 –20 –25 –30 J1 |S11| J2 |S11| J1 |S22| J2 |S22| –35 –40 –10 –15 –20 –25 –45 –30 0 1 2 3 4 5 0 6 1 2 4 5 6 Frequency (GHz) Frequency (GHz) Figure 6. Return Loss vs Frequency (Isolation State) Figure 5. Return Loss vs Frequency (Insertion Loss State) 0 0 –10 –0.2 J1-J2 J2-J1 Insertion Loss (dB) –20 Isolation (dB) 3 –30 –40 –50 3.0 V 3.3 V 5.0 V –0.4 –0.6 –0.8 –1.0 –1.2 –60 –1.4 –70 –1.6 –1.8 –80 0 1 2 3 4 5 6 0 +4 +8 +12 +16 +20 +24 +28 +32 Input Power (dBm) Frequency (GHz) Figure 7. Output to Output Isolation Figure 8. Insertion Loss vs Input Power Over Voltage +55 IP3 (dBm) +50 +45 +40 0.7-1.0 GHz 1.0-2.0 GHz +35 +30 2.8 3.0 3.2 3.4 3.6 3.8 4.0 4.2 4.4 4.6 4.8 5.0 Supply Voltage (V) Figure 9. IP3 vs VDD Supply Voltage Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 200570E • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • July 30, 2009 5 DATA SHEET • SKY13286-359LF SPDT ABSORPTIVE SWITCH Table 5. SKY13286-359LF Truth Table VCTL RFC to J1 RFC to J2 0 Insertion loss Isolation 1 Isolation Insertion loss Evaluation Board Description Package and Handling Information The SKY13286-359LF Evaluation Board is used to test the performance of the SKY13286-359LF SPDT absorptive switch. An assembly drawing for the Evaluation Board is shown in Figure 10. Instructions on the shipping container label regarding exposure to moisture after the container seal is broken must be followed. Otherwise, problems related to moisture absorption may occur when the part is subjected to high temperature during solder assembly. Package Dimensions THE SKY13286-359LF is rated to Moisture Sensitivity Level 1 (MSL1) at 260 °C. It can be used for lead or lead-free soldering. For additional information, refer to the Skyworks Application Note, Solder Reflow Information, document number 200164. The PCB layout footprint for the SKY13286-359LF is shown in Figure 11. Typical case markings are noted in Figure 12. Package dimensions for the 16-pin QFN are shown in Figure 13, and tape and reel dimensions are provided in Figure 14. Care must be taken when attaching this product, whether it is done manually or in a production solder reflow environment. Production quantities of this product are shipped in a standard tape and reel format. For packaging details, refer to the Skyworks Application Note, Discrete Devices and IC Switch/Attenuators Tape and Reel Package Orientation, document number 200083. GND VP VDD J2 VCTL J1 ?? VCTL 1 RFC ?? J3 J1 CBLK Through ?? ?? CBL = 47 pF capacitor (5 places) J2 Through S1597 Figure 10. SKY13286-359LF Evaluation Board Assembly Diagram Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 6 July 30, 2009 • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • 200570E DATA SHEET • SKY13286-359LF SPDT ABSORPTIVE SWITCH 8X 1.600 0.325 Typ R0.200 Solderable Area Pin 1 8X 1.600 2X 1.350 Package Outline 0.30 See Detail A For Solderable Area 2X 1.350 Solderable Area 0.650 Pitch 0.55 Detail A S1598 Figure 11. SKY13286-359LF PCB Layout Footprint Pin 1 Indicator S286 XXXX YWW Skyworks P/N Skyworks GaAs Die Lot # Date Code Y = Calendar Year WW = Week Figure 12. Typical Case Markings Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 200570E • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • July 30, 2009 7 DATA SHEET • SKY13286-359LF SPDT ABSORPTIVE SWITCH 0.20 Ref 4.00 0.02 +0.03/–0.02 Pin 1 Indicator Seating Plane 2.70 +0.10/–0.15 1.35 +0.05/–0.075 Exposed Pad Pin 1 Ind. 0.20 Min. Typ. 0.65 4.00 0.325 2.70 +0.10/–0.15 1.35 +0.05/–0.075 0.40 ± 0.10 0.90 ± 0.10 0.30 ± 0.05 All dimensions are in millimeters S1596 Figure 13. SKY13286-359LF 16-Pin QFN Package Dimensions ∅1.50 2.00 ± 0.05 ± 0.10 1.75 ± 0.10 B A A 12.00 +0.30/–0.10 1.13 ± 0.10 4.00 ± 0.10 5.50 ± 0.05 8.00 ± 0.10 Reference Pin Indicator 4.25 ± 0.10 10o Max B ∅1.50 ± 0.25 0.229 ± 0.02 B 10o Max Notes: 1. Carrier tape material: black conductive polycarbonate or polysterene 2. Cover tape material: transparent conductive PSA 3. Cover tape size: 9.3 mm width 4. All measurements are in millimeters 4.25 ± 0.10 A S1056 Figure 14. SKY13286-359LF Tape and Reel Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 8 July 30, 2009 • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • 200570E DATA SHEET • SKY13286-359LF SPDT ABSORPTIVE SWITCH Ordering Information Model Name SKY13286-359LF SPDT Absorptive Switch Manufacturing Part Number SKY13286-359LF (Pb-free package) Evaluation Board Part Number SK39110, rev. 2 Copyright © 2009 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 200570E • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • July 30, 2009 9