TI LMX2581SQE

LMX2581
www.ti.com
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
LMX2581 Wideband Frequency Synthesizer with Integrated VCO
Check for Samples: LMX2581
FEATURES
•
•
1
General Features
2
•
•
•
•
•
•
•
•
•
•
50 – 3760 MHz Operating Frequency
Low Voltage Logic Compatibility
Digital Lock Detect
32 Pin QFN Package
High Performance PLL
-229 dBc/Hz Normalized PLL Phase Noise
-120.8 dBc/Hz Normalized PLL 1/f Noise
200 MHz Maximum Phase Detector Frequency
Programmable Charge Pump Current
Broadband Multi-Core VCO
Tuning Range: 1880 - 3760 MHz
-137 dBc/Hz Phase Noise @ 1 MHz for a 2.5
GHz Carrier
•
•
Programmable Output Power
Programmable Option to Use an External VCO
Low Noise VCO Divider
Programmable to divide by 1 (bypass), 2, 4, 6,
8, ... , 38
-155 dBc/Hz Noise Floor
TARGET APPLICATIONS
•
•
•
•
•
Wireless Infrastructure (UMTS, LTE, WiMax,
Multi-Standard Base Stations)
Broadband Wireless
Wireless Meter Reading
Test and Measurement
Clock Generation
DESCRIPTION
The LMX2581 is an ultra low noise wideband frequency synthesizer which integrates a delta-sigma fractional N
PLL, a VCO with fully integrated tank circuit, and an optional frequency divider.
The LMX2581 integrates several low-noise, high precision LDOs to provide superior supply noise immunity and
more consistent performance. When combined with a high quality reference oscillator, the LMX2581 generates a
very stable, ultra low noise signal. The internal VCO can be bypassed so that an external VCO can be used.
FUNCTIONAL BLOCK DIAGRAM
Vtune
Low
Noise
LDO
Multiple
Core VCO
FLout
MUX
Fin
Comp
RFoutA
MUX
Output
Divider
I
Charge
Pump
CPout
N Divider
LD
BUFEN
MUXout
RFoutB
MUX
2X
OSCin
MUX
R
Divider
DATA
Serial Interface
Control
CLK
LE
CE
1
2
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
All trademarks are the property of their respective owners.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2012–2013, Texas Instruments Incorporated
LMX2581
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
www.ti.com
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
VccFRAC
GND
MUXout
OSCin
VccDIG
GND
BUFEN
LD
32
31
30
29
28
27
26
25
CONNECTION DIAGRAM
CLK
1
24
VregVCO
DATA
2
23
VbiasCOMP
LE
3
22
VrefVCO
CE
4
0
21
GND
DAP
14
15
16
RFoutB-
VccBUF
VccVCO
RFoutB+
17
13
8
12
GND
RFoutA-
GND
RFoutA+
18
11
7
Fin
VbiasVCO
CPout
9
Vtune
19
10
20
6
VccPLL
5
GND
FLout
VccCP
Table 1. Pin Descriptions
2
Pin #
Pin Name
Type
0
DAP
GND
The DAP should be grounded
Description
1
CLK
Input
MICROWIRE Clock Input. High Impedance CMOS input
2
DATA
Input
MICROWIRE Data. High Impedance CMOS input
3
LE
Input
MICROWIRE Latch Enable. High Impedance CMOS input
4
CE
Input
Chip Enable Pin
5
FLout
Output
Fastlock Output that can be high Z or ground.
6
VccCP
Supply
Charge Pump Supply
7
CPout
Output
Charge Pump Output
8
GND
GND
Ground for the Charge Pump.
Ground for the N and R divider.
9
GND
GND
10
VccPLL
Supply
11
Fin
Input
12
RFoutA+
Output
Differential divided output.
13
RFoutA-
Output
Differential divided output.
14
RFoutB+
Output
Differential divided output.
15
RFoutB-
Output
Differential divided output.
16
VccBUF
Supply
Supply for the Output Buffer
17
VccVCO
Supply
Supply for the VCO
18
GND
GND
19
VbiasVCO
20
Vtune
Input
VCO tuning Voltage input
21
GND
GND
VCO ground.
Supply for the PLL
High frequency input pin for an external VCO. Leave Open or Ground if not used.
Ground Pin for the VCO. This can be attached to the regular ground. Ensure a solid trace connects
this pin to the bypass capacitors on pins 19, 23, and 24.
Bias circuitry for the VCO. Place a 2.2 µF capacitor to GND (Preferably close to Pin 18).
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
LMX2581
www.ti.com
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
Table 1. Pin Descriptions (continued)
Pin #
Pin Name
Type
Description
VCO capacitance. Place a capacitor to GND (Preferably close to Pin 18). This value should be
between 5% and 10% of the capacitance at pin 24. Recommended value is 1 uF.
22
VrefVCO
23
VbiasCOMP
24
VregVCO
25
LD
Output
26
BUFEN
Input
Enable pin for the RF output buffer
27
GND
GND
Digital Ground.
28
VccDIG
Supply
Digital Supply
VCO bias voltage temperature compensation circuit. Place a 10 uF capacitor to GND (Preferably
close to Pin 18). If it is possible, put two 10 uF capacitors as this may improve the VCO phase noise
slightly.
VCO regulator output. Place a 10 uF capacitor to GND (Preferably close to Pin 18). If it is possible,
put two 10 uF capacitors as this may improve the VCO phase noise slightly.
Lock detect output
29
OSCin
Input
30
MUXout
Output
Reference input clock
31
GND
GND
Ground for the fractional circuitry.
32
VccFRAC
Vcc
Supply for the fractional circuitry.
Multiplexed output that can select lock detect, N divider, or R dividert.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
3
LMX2581
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
Absolute Maximum Ratings (1)
www.ti.com
(2)
Parameter
Symbol
Ratings
Units
Power Supply Voltage
Vcc
-0.3 to 3.6
V
Input Voltage to Pins other than Vcc Pins
VIN
-0.3 to (Vcc + 0.3)
V
Storage Temperature Range
TSTG
-65 to 150
°C
Lead Temperature (solder 4 sec.)
TL
+260
°C
VOSCin
≤1.8 with Vcc Applied
≤1 with Vcc=0
Vpp
Voltage on OSCin (Pin29)
(1)
(2)
"Absolute Maximum Ratings" indicate limits beyond which permanent or latent damage to the device may occur. Operating Ratings
indicate conditions for which the device is intended to be functional, but do not ensure specific performance limits. For ensured
specifications and test conditions, see the Electrical Characteristics.
This device has an ESD rating of ≥2500 V Human Body Model (HBM), ≥ 1250 V Charged Device Model (CDM), and ≥ 250 V Machine
model (MM). It should only be assembled in ESD free workstations.
Recommended Operating Conditions
4
Parameter
Symbol
Min
Typ
Max
Power Supply Voltage
Vcc
3.15
3.3
3.45
V
Ambient Temperature
TA
-40
85
°C
Submit Documentation Feedback
Units
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
LMX2581
www.ti.com
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
Electrical Characteristics
(3.15 V ≤ Vcc ≤ 3.45 V, -40°C ≤ TA ≤ 85 °C; except as specified. Typical values are at Vcc = 3.3 V, 25 °C.)
Symbol
Parameter
Conditions
Min
Typ
Max
Units
ICC
Entire Chip Supply
Current
One Output Enabled
OUTx_PWR = 15
178
mA
ICCCore
Supply Current Except
for Output Buffers
VCO Divider Bypassed
134
mA
ICCRFout
Additive Current for
Output Buffer
OUTx_PWR = 15
44
mA
ICCVCO_DIV
Additive VCO Divider
Current
VCO Divider > 1
20
mA
ICCPD
Power Down Current
Device Powered Down
(CE Pin = LOW)
7
mA
fOSCin
OSCin Frequency
Range
Doubler Enabled
5
250
Doubler Disabled
5
900
vOSCin
OSCin Input Voltage
AC Coupled
0.4
1.7
SpurFoscin
Oscin Spur
Current Consumption
OSCin Reference Input
-81
MHz
Vpp
dBc
PLL
fPD
Phase Detector
Frequency
Fractional Mode
200
Gain = 1X
110
Gain = 2X
220
...
...
KPD
Charge Pump Gain
Gain = 31X
3410
PNPLL_1/f
Normalized PLL 1/f
Noise
Gain > 8X
- 120.8
dBc
/Hz
PNPLL_Flat
Normalized PLL Noise
Floor
Gain > 8X
- 229
dBc
/Hz
fRFin
External VCO Input Pin
Frequency
Internal VCOs Bypassed
(OUTA_PD=OUTB_PD=1)
0.5
2.2
GHz
pRFin
External VCO Input Pin
Power
Internal VCOs Bypassed
(OUTA_PD=OUTB_PD=1)
0
+8
dBm
SpurFpd
Phase Detector Spurs
Fpd = 25 MHz
-85
Fpd = 100 MHz
-71
VCO
fVCO
Before the VCO Divider
KVCO
VCO Gain
ΔTCL
Allowable Temperature
Drift
(2)
(3)
(3)
µA
dBc
(1)
Vtune = 1.3 Volts
(2)
All VCO Cores
Combined
1880
VCO not being recalibrated
3760
Core 1
12 - 24
Core 2
15 - 30
Core 3
20 - 37
Core 4
(1)
MHz
MHz/
V
21 - 37
Fvco ≥2.5 GHz
-125
+125
Fvco < 2.5 GHz
- 100
+125
°C
All four VCO cores cover the range as reported in the specifications and the typical tuning ranges for each core are also reported.
However, at some of the frequencies that are at the boundary of two cores, it might not be always possible to ensure which core the
LMX2581 would use to achieve this frequency.
The lower number for the VCO gain applies to the lower end of the tuning range for that VCO core and the upper number for the VCO
gain applies to the upper range for that VCO core.
Continuous tuning range over temperature refers to programming the device at an initial temperature and allowing this temperature to
drift WITHOUT reprogramming the device. This drift could be up or down in temperature and the spec does not apply to temperatures
that go outside the recommended operating temperatures of the device.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
5
LMX2581
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
www.ti.com
Electrical Characteristics (continued)
(3.15 V ≤ Vcc ≤ 3.45 V, -40°C ≤ TA ≤ 85 °C; except as specified. Typical values are at Vcc = 3.3 V, 25 °C.)
Symbol
tVCOCal
Parameter
Conditions
VCO Calibration Time
(4)
fOSCin = 100 MHz
fPD = 100 MHz
Full Band Change 1880 — 3760
MHz
fVCO = 1.9 GHz
Core 1
fVCO = 2.2 GHz
Core 2
PNVCO
VCO Phase Noise
(OUTx_PWR =15)
fVCO = 2.7 GHz
Core 3
fVCO = 3.3 GHz
Min
Typ
No Preprogramming
140
With Preprogramming
10
Max
Units
us
10 kHz Offset
-84.8
100 kHz Offset
-113.7
1 MHz Offset
-136.7
10 MHz Offset
-154.2
40 MHz Offset
-156.7
10 kHz Offset
-84.6
100 kHz Offset
-114.1
1 MHz Offset
-137.5
10 MHz Offset
-154.5
40 MHz Offset
-155.2
10 kHz Offset
-81.7
100 kHz Offset
-111.1
1 MHz Offset
-135.5
10 MHz Offset
-152.9
40 MHz Offset
-154.6
10 kHz Offset
-77.9
100 kHz Offset
-108.0
1 MHz Offset
-132.4
10 MHz Offset
-151.5
40 MHz Offset
-153.6
dBc
/Hz
dBc
/Hz
dBc
/Hz
dBc
/Hz
Outputs
pRFoutA+/pRFoutB+/-
Output Power Level
H2RFoutX+/-
Output Power Level
(5)
(6)
OUTx_PWR=15
Inductor Pull-Up
Fout=2.7 GHz
5
dBm
OUTx_PWR = 15
Fout = 2.7 GHz
-25
dBc
Digital Interface (DATA, CLK, LE, CE, MUXout,BUFEN, LD)
VIH
High-Level Input Voltage
VIL
Low Level Input Voltage
1.4
IIH
High-Level Input Current
VIH = 1.75 V
IIL
Low-Level Input Current
VOH
Vcc
V
0.4
V
-5
5
µA
VIL = 0 V
-5
5
µA
High-Level Output
Voltage
IOH = -500 µA
2
VOL
Low-Level Output
Voltage
IOL = -500 µA
tES
Clock to Enable Low
Time
V
0
0.4
V
MICROWIRE Timing
(4)
(5)
(6)
6
See Serial Data Input Timing
35
ns
When the VCO is programmed to a frequency, it goes through a digital calibration where it searches for the correct frequency band until
it reaches the final frequency band. After this frequency calibration is done, the VCO will typically be far less than 1 MHz within the final
target frequency. This final frequency error is corrected analog lock time, which is totally loop filter dependent, but it can be made <2 us
for a wide enough loop filter (perhaps at the expense of fractional spurs). The number reported in the electrical specifications is for this
digital VCO calibration time only. The lock time can be greatly reduced if the user can preprogram the device with an initial starting point
for which VCO core and what frequency band in the core to start the VCO frequency calibration at. Even if it is the wrong core and the
wrong band, it can greatly reduce the lock time provided that this frequency close (<20 MHz) of the final settling frequency.
The output power is dependent of the setup and is also programmable. Consult the Applications section for more information.
The harmonics vary as a function of frequency, output termination, board layout, and output power setting. Reported number is for an
OUTx_PWR of 15.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
LMX2581
www.ti.com
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
Electrical Characteristics (continued)
(3.15 V ≤ Vcc ≤ 3.45 V, -40°C ≤ TA ≤ 85 °C; except as specified. Typical values are at Vcc = 3.3 V, 25 °C.)
Symbol
Parameter
Conditions
Min
Typ
Max
Units
tCS
Data to Clock Set Up
Time
See Serial Data Input Timing
10
ns
tCH
Data to Clock Hold Time
See Serial Data Input Timing
10
ns
tCWH
Clock Pulse Width High
See Serial Data Input Timing
25
ns
tCWL
Clock Pulse Width Low
See Serial Data Input Timing
25
ns
tCES
Enable to Clock Set Up
Time
See Serial Data Input Timing
10
ns
tEWH
Enable Pulse Width
High
See Serial Data Input Timing
10
ns
SERIAL DATA INPUT TIMING
MSB
DATA
D27
LSB
D26
D25
D24
D23
D0
A3
A2
A1
A0
CLK
tCES
tCS
tCH
tCWH
tCWL
tES
LE
tEWH
There are several other considerations for programming:
• The DATA is clocked into a shift register on each rising edge of the CLK signal. On the rising edge of the LE
signal, the data is sent from the shift registers to an actual counter.
• A slew rate of at least 30 V/us is recommended for the CLK, DATA, and LE signals
• If the CLK and DATA lines are toggled while the in VCO is in lock, as is sometimes the case when these lines
are shared with other parts, the phase noise may be degraded during the time of this programming.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
7
LMX2581
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
www.ti.com
Functional Description
The LMX2581 is a low power, high performance frequency synthesizer system which includes a PLL (Phased
Locked Loop), VCO (Voltage Controlled Oscillator), VCO Divider, and Programmable Output Buffer.
OSCin INPUT and OSCin DOUBLER
The OSCin pin is driven with a single-ended signal which is used to as a frequency reference. Before the OSCin
frequency reaches the phase detector, it can be doubled with the OSCin doubler and/or divided with the PLL R
divider.
Because the OSCin signal is used as a clock for the VCO calibration, the OSC_FREQ field needs to be
programmed correctly and a proper signal needs to be applied at the OSCin pin at the time of programming the
R0 register order for the VCO calibration to properly work. Higher slew rates tend to yield the best fractional
spurs and phase noise, so a square wave signal is best for OSCin. If using a sine wave, higher frequencies tend
to yield better phase noise and fractional spurs due to their higher slew rates. The OSCin pin his high
impedance, so for optimal performance, it is recommended to use either a shunt resistor or resistive pad to make
such that the impedances looking towards our device and from the looking away from our device (as seen by the
OSCin pin) are both close to 50 ohms
R DIVIDER
The R divider divides the OSCin frequency down to the phase detector frequency. With this device, it is possible
to use both the doubler and the R divider at the same time.
PLL N DIVIDER AND FRACTIONAL CIRCUITRY
The N divider includes fractional compensation and can achieve any fractional denominator (PLL_DEN) from 1 to
4,194,303. The integer portion, PLL_N, is the whole part of the N divider value and the fractional portion,
PLL_NUM / PLL_DEN, is the remaining fraction. PLL_N, PLL_NUM, and PLL_DEN are software programmable.
So in general, the total N divider value, N, is determined by: N = PLL_N + PLL_NUM / PLL_DEN The order of
the delta sigma modulator is programmable from integer mode to third order. There are also several dithering
modes that are also programmable. In order to make the fractional spurs consistent, the modulator is reset any
time that the R0 register is programmed.
PLL PHASE DETECTOR AND CHARGE PUMP
The phase detector compares the outputs of the R and N dividers and generates a correction current
corresponding to the phase error. This charge pump current is software programmable to many different levels.
The phase detector frequency, fPD, can be calculated as follows: fPD = fOSCin × OSC_2X / R. The charge pump
outputs a correction current the loop filter, which is implemented with external components.
EXTERNAL LOOP FILTER
The LMX2581 requires an external loop filter. The design of this filter is application specific and can be done by
software provided on the Texas Instruments website. For the LMX2581, it is recommended for the best possible
VCO noise to ensure a capacitor of at least 3.3 nF next to the VCO. Not doing so will degrade the VCO phase
noise at offsets in the 100k-1MHz region, although the device will still function properly.
LOW NOISE, FULLY INTEGRATED VCO
The VCO takes the voltage from the loop filter and converts this into a frequency. The VCO frequency is related
to the other frequencies and divider values as follows: fVCO = fPD × N = fOSCin × OSC_2X × N / R. The VCO is
fully integrated, including the tank inductors.
In order to the reduce the VCO tuning gain and therefore improve the VCO phase noise performance, the
internal VCO is actually four VCO cores working in conjunction. These cores starting from lowest frequency to
highest frequency are VCO 1, VCO 2, VCO 3, and VCO 4. Each VCO core has 256 different frequency bands.
This creates the need for frequency calibration in order to determine the correct VCO core and correct frequency
band in that VCO core. The frequency calibration routine is activated any time that the R0 register is
programmed with the NO_FCAL bit equal to zero. In order for this frequency calibration to work properly, the
OSC_FREQ field needs to be set to the correct setting. The are also programmable settings that allow the user
to suggest a particular VCO core for the device to choose.
8
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
LMX2581
www.ti.com
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
PROGRAMMABLE VCO DIVIDER
The VCO divider can be programmed to even values from 2 to 38 as well as bypassed by either one or both of
the RFout outputs. When the zero delay mode is not enabled, the VCO divider is not in the feedback path
between the VCO and the PLL and therefore has no impact on the PLL loop dynamics. After this programmable
divider is changed, it may be beneficial to reprogram the R0 register to recallibrate the VCO . The frequency at
the RFout pin is related to the VCO frequency and divider value, VCO_DIV, as follows: fRFout = fVCO / VCO_DIV
When this divider is enabled, there will be some far-out phase noise contribution to the VCO noise. .
When changing to a VCO_DIV value of 4, either from a state of VCO_DIV=2 or OUTx_MUX = 0, it is necessary
to program VCO_DIV first to a value of 6, then to a value of 4. This holds for no other VCO_DIV value and is not
necessary if the VCO frequency (but not VCO_DIV) is changing
0–DELAY MODE
In the event that the VCO divider is not used, there is a deterministic phase relationship between the OSCin and
RFout pins. However, when the VCO divider is used, it creates an ambiguous phase relationship when 0–Delay
mode is not enabled. When 0–Delay mode is enabled, it includes the VCO divider in the feedback path to make
the phase relationship between OSCin and Fout deterministic.
When this mode is used, special care needs to be taken because it does interfere with the VCO calibration if not
done correctly. The correct way to use 0–Delay mode is as follows
1.
2.
3.
4.
5.
Calibration with Zero Delay
Program the 0_DLY bit = 1
Program the NO_FCAL bit = 1
Program the R0 register with the RF_N value multiplied by the VCO_DIV value.
Set the NO_FCAL bit = 0
Program the R0 register again with RF_N value not being multiplied by the VCO_DIV value.
DETERMINING THE OUTPUT FREQUENCY
Based on the oscillator input frequency (fOSC), PLL R divider value (PLL_R), PLL N Divider Value (PLL_N),
Fractional Numerator (PLL_NUM), Fractional Denominator (PLL_DEN), and VCO divider value (VCO_DIV), the
output frequency of the LMX2581 (fOUT) can be determined as follows:
fOUT = fOSC x OSC_2X / PLL_R x (PLL_N + PLL_NUM / PLL_DEN) / VCO_DIV
PROGRAMMABLE RF OUTPUT BUFFERS
The output states of the RFoutA and RFoutB pins are controlled by the BUFEN pin as well as the BUFEN_DIS
programming bit. If the pin is powered up, then output power can be programmed to various levels with the
OUTx_PWR fields.
OUTA_PD
OUTB_PD
BUFEN_DIS
BUFEN Pin
Output State
1
X
X
Powered Down
0
0
1
X
Powered Up
Low
Powered Down
High
Powered Up
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
9
LMX2581
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
www.ti.com
POWERDOWN MODES
The LMX2581 can be powered down either partially or fully. The partial powerdown powers down the PLL, VCO,
and output buffer, but keeps the LDOs running. The full powerdown powers down everything, although register
settings are still retained. The type of powerdown is governed by the PWDN_MODE field and the CE pin in
accordance to the following table.
PWDN_MODE
CE Pin
Device State
0
X
Powered Up
1
X
Full Powerdown
3
X
Partial Powerdown
4
Low
Full Powerdown
Powered Up
Low
5
7
Partial Powerdown
Up
Powered Up
Low
Full Powerdown
High
Partial Powerdown
X
Invalid State
2,6
When coming out of a full powerdown state, it is necessary to do the initial power on programming sequence
described in later sections. If coming out of a partial powerdown state, it is necessary to do the sequence for
switching frequencies after initialization, that is described in later sections.
FASTLOCK
The LMX2581 includes the Fastlock™ feature that can be used to improve the lock times. When the frequency is
changed, a timeout counter is used to engage the fastlock for a programmable amount of time. During the time
that the device is in Fastlock, the FLout pin changes from high impedance to low, thus switching in the external
resistor R2pLF in parallel with R2_LF.
Vtune
Charge
Pump
CPout
C2_LF
Fastlock
Control
FLout
C1_LF
R2pLF
R2_LF
Parameter
Normal Operation
Charge Pump Gain
CPG
Fastlock
FL_CPG
FLout Pin
High Impedance
Grounded
Once the loop filter values and charge pump gain are known for normal operation, they can be determined for
fastlock operation as well. In normal operation, one can not use the highest charge pump gain and still use
fastlock because there will be no larger current to switch in. The resistor and the charge pump current are
changed simultaneously so that the phase margin remains the same while the loop bandwidth is by a factor of K
as shown in the following table:
10
Parameter
Symbol
Calculation
Charge Pump Gain in Fastlock
FL_CPG
Typically use the highest value.
Loop Bandwidth Multiplier
K
K=sqrt(FL_CPG/CPG)
External Resistor
R2pLF
R2 / (K-1)
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
LMX2581
www.ti.com
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
Lock Detect
The LMX2581 offers two forms of lock detect, Vtune and Digital Lock Detect, which could be used separately or
in conjunction. Digital Lock Detect gives a reliable indication of lock/unlock if programmed correctly with the one
exception of when the PLL is locked to a valid OSCin signal and then the OSCin signal is abruptly removed. In
this case, digital lock detect can sometimes still indicate a locked state, but Vtune Lock detect will correctly
indicate an unlocked state. Therefore, for the most reliable lock detect, it is recommended to use these in
conjunction, because they cover the deficits of each other.
Vtune Lock Detect
This style of lock detect only works with the internal VCO. Whenever the tuning voltage goes below the threshold
of about 0.5 volts or above the threshold of about 2.2 volts, the internal VCO will become unlocked and the
Vtune lock detect will indicate that the device is unlocked. For this reason, when the Vtune lock detect says the
PLL is unlocked, one can be certain that it is unlocked.
Digital Lock Detect
This lock detect works by comparing the phase error as presented to the phase detector. If the phase error plus
the delay as specified by the PFD_DLY bit outside the tolerance as specified by DLD_TOL, then this comparison
would be considered to be an error, otherwise passing. At higher phase detector frequencies, it may be
necessary to adjust the DLD_ERR_CNT and DLD_PASS_CNT. The DLD_ERR_CNT specifies how may errors
are necessary to cause the circuit to consider the PLL to be unlocked. The DLD_PASS_CNT multiplied by 8
specifies how many passing comparisons are necessary to cause the PLL to be considered to be locked and
also resets the count for the errors. The DLD_ERR_CNT and DLD_PASS_CNT values can be decreased to
make the circuit more sensitive, but if lock detect is made too sensitive chattering can occur and these values
should be increased.
PART ID AND REGISTER READBACK
The LMX2581 allows any of its registers to be read back. This could be useful for
• Register Readback
– By reading back the register values, it can be confirmed that the correct information was written. In
addition to this, Register R6 has special diagnostic information that could potentially be useful for
debugging problem.
• Part ID Readback
– By reading back the part ID, this information can be used by whatever device is programming the
LMX2581 to identify this device and know what programming information to send. In addition to this, the
BUFEN and CE pins can be used to create 4 unique part ID values. Although these pins can impact the
device, they can be overridden in software. It is not necessary to have the device programmed in order to
do part ID readback.
The procedure for doing this readback is as follows:
1. Hold the LE pin high
2. Send 32 clocks to the CLK pin and monitor the output at the LD pin to read back the bit stream of 32 bits
3. Depending on the settings for the ID(R0[31]) and RDADDR (R6[8:5]), information a different bit stream will be
returned as shown in the following table. .
ID
RDADDR
BUFEN Pin
CE Pin
Read Back Code
0
6
X
X
Register Readback
(Register R6)
0
0
0
0x 00000500
0
0
1
0x 00000510
1
1
0
0x 00000520
1
1
1
0x 00000530
1
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
11
LMX2581
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
www.ti.com
General Programming Information
The LMX2581 is programmed using several 32-bit registers. A 32-bit shift register is used as a temporary register
to indirectly program the on-chip registers. The shift register consists of a data field and an address field. The last
4 bits, ADDR[3:0] form the address field, which is used to decode the internal register address. The remaining 28
bits form the data field DATA[27:0]. While LE is low, serial data is clocked into the shift register upon the rising
edge of clock (data is programmed MSB first). When LE goes high, data is transferred from the data field into the
selected register bank.
Recommended Initial Power on Programming Sequence
When the device is first powered up, the device needs to be initialized and the ordering of this programming is
very important. The following is the sequence. After this sequence is complete, the device should be running and
locked to the proper frequency.
1. Apply power to the device and ensure the Vcc pins are at the proper levels.
2. Ensure that a valid reference is applied to the OSCin pin
3. Program register R5 with RESET=1
4. Program registers R15,R13,R10,R9,R8,R7,R6,R5,R4,R3,R2,R1,R0
5. Wait 20 ms
6. Program the R0 register again OR do the recommended sequence for changing frequencies.
Recommended Sequence for Changing Frequencies
After the device has gone through the initial power on programming sequence, it is not necessary to do this
again. The recommended sequence for changing frequencies is as follows:
1. (optional) If the OUTx_MUX State is changing, program Register R5
2. (optional) If the VCO_DIV state is changing, program Register R3. See section on VCO_DIV if programming
a to a value of 4.
3. (optional) If the MSB of the fractional numerator or charge pump gain is changing, program register R1
4. (Required) Program register R0
Although not necessary, it is also acceptable to program the R0 register a second time after this programming
sequence.
Triggering Registers
The action of programming certain registers may trigger special actions as shown in the table below.
Reg
R5
12
Conditions
Actions Triggered
Why this is done
RESET = 1
The registers are reset by the power on reset
All Registers are reset to power on circuitry when power is initially applied. The
default values. This takes less than 1 RESET bit allows the user the option to
perform the same functionality of the power
us. The reset bit is self-clearing.
on reset through software.
R0
NO_FCAL = 0
—Starts the Frequency Calibration
—Engages Fastlock (If FL_TOC>0)
This activates the frequency calibration, which
chooses the correct VCO core and also the
correct frequency band within that core. This
is necessary whenever the frequency is
changed. If it is desired that the R0 register be
programmed without activating this calibration,
then the NO_FCAL bit can be set to zero. If
the fastlock timeout counter is programmed to
a nonzero value, then this action also
engages fastlock.
R0
NO_FCAL = 1
—Engages Fastlock (If FL_TOC>0)
This engages fastlock, which can be used to
decrease
the
lock
time
in
some
circumstances.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
LMX2581
www.ti.com
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
Table 2. Register Map
Register
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
DATA[27:0]
R15
0
R13
0
0
0
0
0
1
DLD_ERR_CNT[3:0]
0
0
0
0
1
1
1
1
1
1
DLD_
TOL
[2:0]
DLD_PASS_CNT[9:0]
2
1
0
ADDRESS[3:0]
1
1
VCO
_
CAP
_
MAN
1
0
0
0
0
0
1
0
0
0
VCO_CAPCODE[7:0]
1
1
1
1
0
1
1
0
1
R10
0
0
1
0
0
0
0
1
0
0
0
0
0
0
0
0
0
1
0
1
0
0
0
0
1
1
0
0
1
0
1
0
R9
0
0
0
0
0
0
1
1
1
1
0
0
0
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
0
0
1
R8
0
0
1
0
0
0
0
0
0
1
1
1
1
1
0
1
1
1
0
1
1
0
1
1
1
1
1
1
1
0
0
0
LD_
PINMODE[2:0]
0
1
1
1
uWI
RE_
LOC
K
0
1
1
0
RES
ET
0
1
0
1
0
1
0
0
0
0
1
1
0
0
1
0
0
0
0
1
0
0
0
0
R7
0
R6
0
R5
0
FL_SELECT
[4:0]
0
0
0
0
0
0
1
0
0
0
R2
0
0
OSC
_2X
0
CPP
1
OUT
_LD
EN
FRAC_
DITHER
[1:0]
BUF
EN_
DIS
OSC_FREQ[2:0]
0
0
0
0
LD_SELECT
[4:0]
1
0
0
VCO_
SEL_
MODE
[1:0]
OUTB_
MUX
[1:0]
FL_CPG[4:0]
VCO_DIV[4:0]
OUTB_PWR[5:0]
OUTA
_MUX
[1:0]
0_
DLY
LD_
INV
0
RDADDR[3:0]
MODE
[1:0]
0
PWDN_MODE
[2:0]
CPG_BLEED[5:0]
OUT
B
_PD
OUTA_PWR[5:0]
PLL_DEN[21:0]
VCO_
SEL
[1:0]
CPG[4:0]
ID
MUXOUT_SELECT
[4:0]
FL_TOC[11:0]
0
R0
0
FL_
FRC
E
R3
R1
FL_
INV
MUXOUT_
PINMODE
[2:0]
RD_DIAGNOSTICS[19:0]
PFD_DLY
[2:0]
R4
FL_PINMODE
[2:0]
MUX
_
INV
NO_
FCA
L
PLL_NUM[21:12]
PLL_N[11:0]
FRAC_
ORDER
[2:0]
PLL_R[7:0]
PLL_NUM[11:0]
OUT
A
_PD
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
13
LMX2581
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
www.ti.com
Programming Field Descriptions
REGISTER R15
The programming of register R15 is not necessary and only needs to be done in situations where the
programming fields in this register need to be changed. This is typically for diagnostic purposes or improving the
digital VCO calibration time.
VCO_CAP_MAN — Manual VCO Band Select
This bit determines if the value of VCO_CAPCODE is just used as a starting point for the initial frequency
calibration or if the VCO is forced to this value. If this is forced, it is only for diagnostic purposes.
VCO_CAP_MAN
Impact of VCO_CAPCODE
Application
0
Determines initial starting point for VCO
calibration.
Setting the VCO_CAPCODE field can
improve the digital calibration time.
1
Forces the band for the VCO all the time.
For diagnostic purposes only.
VCO_CAPCODE[7:0] — Capacitor Value for VCO Band Selection
This field selects the capacitor value that is initially used for the VCO tank when the VCO calibration is run or that
is forced when VCO_CAP_MAN is set to one. The lower values correspond to less capacitance, which
corresponds to a higher VCO Frequency for that given VCO Core. If not using this feature, the default value for
this field is 128.
VCO_CAPCODE
VCO Tank Capacitance
VCO Frequency
Highest
0
Minimum
...
...
255
Maximum
Lowest
REGISTER R13
Register R13 gives access to bits that are used for the digital lock detect circuitry.
DLD_ERR_CNT[3:0] - Digital Lock Detect Error Count
This is the amount of phase detector comparisons that may exceed the tolerance as specified in DLD_TOL
before digital lockindicates an unlocked state. The recommended default is 4 for phase detector frequencies of
80 MHz or below, but larger values may be necessary for higher phase detector frequencies.
DLD_PASS_CNT[9:0] - Digital Lock Detect Success Count
This value multiplied by 8 is the amount of amount of phase detector comparisons within the tolerance specified
by DLD_TOL and adjusted by DLD_ERR_CNT that are necessary that are necessary to cause the digital lock to
indicate a locked state. The recommended default value is 32 for phase detector frequencies of 80 MHz or
below, but larger values may be necessary for higher phase detector frequencies.
DLD_TOL[2:0] — Digital Lock Detect
This is the tolerance that is used to compare with each phase error to decide if it is a success or a fail. Larger
settings are generally recommended, but they are limited by several factors such as PFD_DLY, modulator order,
and especially the phase detector frequency.
14
DLD_TOL
Phase Error Tolerance (ns)
0
1
Fpd > 130 MHz
1
1.7
80 MHz > Fpd >= 130 MHz
2
3
60 MHz > Fpd >= 80 MHz
3
6
45 MHz > Fpd >= 60 MHz
4
10
30 MHz >Fpd >= 45 MHz
5
18
Fpd <= 30 MHz
6–7
Reserved
n/a
Submit Documentation Feedback
Typical Phase Detector Frequency
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
LMX2581
www.ti.com
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
REGISTERS R10, R9, and R8
These registers have no functions that are disclosed to the user. However, it is still important to program them to
the values specified in the register map because they are necessary for proper operation.
REGISTER R7
This register has fields that control status pins, which would be LD, MUXout, and FLout
FL_PINMODE[2:0], MUXOUT_PINMODE[2:0], and LD_PINMODE[2:0] — Output Format for Status Pins
These fields control the state of the output pin
FL_PINMODE
MUXOUT_PINMODE
LD_PINMODE
Output Type
0
TRI-STATE
(Default for LD_PINMODE)
1
Push-Pull
(Default for MUXOUT_PINMODE)
2
Open Drain
3
High Drive Push-Pull
(Can drive 5 mA for an LED)
4
High Drive Open Drain
5
High Drive Open Source
6,7
Reserved
FL_INV, MUX_INV, LD_INV - Inversion for Status Pins
The logic for the LD and MUXOUT pins can be inverted with these bits.
FL_INV
MUX_INV
LD_INV
Pin Status
0
Normal Operation
1
Inverted
FL_SELECT[4:0], MUXOUT_SELECT[4:0], LD_SELECT[4:0] — State for Status Pins
This field controls the output state of the MUXout, LD, and FLout pins. Note that during fastlock, the FL_SELECT
field is ignored.
FL_SELECT
MUXOUT_SELECT
LD_SELECT
Output
0
Vcc
1
Lock Detect (Based on Phase Measurement)
2
Lock Detect (Based on tuning voltage)
3
Lock Detect (Based on Phase Measurement AND tuning voltage)
4
Readback (Default for MUXOUT_SELECT)
5
PLL_N divided by 2
6
PLL_N divided by 4
7
PLL_R divided by 2
8
PLL_R divided by 4
9
Analog Lock Detect
10
OSCin Detect
11
Fin Detect
12
Calibration Running
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
15
LMX2581
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
FL_SELECT
MUXOUT_SELECT
LD_SELECT
16
www.ti.com
Output
13
Tuning Voltage out of Range
14
VCO calibration fails in the low frequency direction.
15
VCO Calibration fails in the high frequency direction.
16-31
Reserved
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
LMX2581
www.ti.com
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
REGISTER R6
RD_DIAGNOSTICS[19:0] — Readback Diagnostics
This field is contains several pieces of information that can be read back for debug and diagnostic purposes.
RD_DIAGNOISTICS[19:0]
R6
[30:29]
R6
[28]
R6
[27]
R6
[26]
R6
[25:22]
R6
[21]
R6
[20]
R6
[19]
R6
[18]
R6
[17]
R6
[16]
R6
[15]
R6
[14]
R6
[13]
R6
[12]
19 18
17
16
15
[14:11]
10
9
8
7
6
5
4
3
2
1
0
CE_
PIN
STAT
E
BUFE
N_
PIN
STAT
E
VCO_
SEL
ECT
OSCI
N_
DET
ECT
FIN_
DET
ECT
VCO_
DET
ECT
CAL_
Reserved RUNN
ING
VCO_
RAIL_
HIGH
VCO_
RAIL_
LOW
Reser
ved
VCO_
TUNE
_
HIGH
VCO_
TUNE
_
VALID
FLOU
T_
ON
DLD
LD_
PIN
STAT
E
R6
[11]
field Name
Meaning if Value is One
VCO_ SELECT
This is the VCO that the device chose to use. 0 = VCO 1, 1 = VCO 2, 2 = VCO 3, 3 = VCO 4
FIN_DETECT
Indicates transitions at the Fin pin have been detected. This could either be the VCO signal or self-oscillation of the
Fin pin in the even that no signal is present. This bit needs to be manually reset by programing register R5 with
R5[30] = 1, and then again with bit R5[30]=0
OSCIN_DETECT
Indicates transitions at the OSCin pin have been detected. This could either be a signal at the OSCin pin or selfoscillation at the OSCin pin in the event no signal is present . This bit needs to be manually reset by programming
R5 with R5[29] = 1 and then again with R5[29] = 0.
CAL_RUNNING
Indicates that some calibration in the part is currently running.
VCO_RAIL_HIGH
Indicates that the VCO frequency calibration failed because the VCO would need to be a higher frequency than it
could achieve.
VCO_RAIL_LOW
Indicates that the VCO frequency calibration failed because the VCO would need to be a lower frequency than it
could achieve.
VCO_TUNE_HIGH
Indicates that the VCO tuning voltage is higher than 2.4 volts and outside the allowable range.
VCO_TUNE_VALID
Indicates that the VCO tuning voltage is inside then allowable range.
FLOUT_ON
Indicates that the FLout pin is low.
DLD
Indicates that the digital lock detect phase measurement indicates a locked state. This does not include any
consideration of the VCO tuning voltage.
LD_PINSTATE
This is the state of the LD Pin.
CE_PINSTATE
This is the state of the CE pin.
BUFEN_PINSTATE
This is the state of the BUFEN pin.
RDADDR[3:0] — Readback Address
When the ID bit is set to zero, this designates which register is read back from. When the ID bit is set to one, the
unique part ID information is read back.
ID
RDADDR
1
Don't Care
Part ID
0
Register R0
1
Register R1
0
Information Read Back
...
...
15 (default)
Register R15
uWIRE_LOCK - Microwire lock
uWIRE_LOCK
Microwire
0
Normal Operation
1
Locked out – All Programming except to the uWIRE_LOCK bit is ignored
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
17
LMX2581
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
www.ti.com
REGISTER R5
OUT_LDEN — Mute Outputs Based on Lock Detect
When this bit is enabled, the RFoutA and RFoutB pins are disabled if the PLL digital lock detect circuitry
indicates that the PLL is in the unlocked state.
OUT_LDEN
PLL Digital Lock Detect Status
RFoutA / RFoutB Pins
0
Don't Care
Normal Operation
1
Locked
Normal Operation
1
Unlocked
Powered Down
OSC_FREQ[2:0] — OSCin Frequency for VCO Calibration
This bit should be set to in accordance to the OSCin frequency BEFORE the doubler. It is critical for running
internal calibrations for this device.
OSC_FREQ
OSCin Frequency
0
fOSCin < 128 MHz
1
128 ≤ fOSCin < 256 MHz
2
256 ≤ fOSCin < 512 MHz
3
512 ≤ fOSCin
>=4
Reserved
BUFEN_DIS - Disable for the BUFEN Pin
This pin allows the BUFEN pin to be disabled. This is useful if one does not want to pull this pin high or use it for
the readback ID.
BUFEN_DIS
BUFEN Pin
0
Impacts Output buffers
1
Ignored.
VCO_SEL_MODE — Method of Selecting Internal VCO Core
This field allows the user to choose how the VCO selected by the VCO_SEL field is treated. Note setting 0
should not be used if switching from a frequency above 3 GHz to a frequency below 2.2 GHz.
VCO_SEL_MODE
VCO Selection
0
VCO core is automatically selected based on the last one that was used. If none was used before, it chooses
the lowest frequency VCO core.
1
VCO selection starts at the value as specified by the VCO_SEL field. However, if this is invalid, it will choose
another VCO.
2
VCO is forced to the selection as defined by the VCO_SEL field, regardless of whether it is valid or not. Note
that this mode is not ensured and is only included for diagnostic purposes.
3
Reserved
OUTB_MUX — Mux for RFoutB
This bit determines whether RFoutB is the VCO frequency, the VCO frequency divided by VCO_DIV, or the fin
frequency.
OUTB_MUX
18
RFoutB Frequency
0
fVCO
1
fVCO / VCO_DIV
2
fFin
3
Reserved
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
LMX2581
www.ti.com
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
OUTA_MUX — Mux for RFoutA
This bit determines whether RFoutA is the VCO frequency, the VCO frequency divided by VCO_DIV, or the fin
frequency.
OUTA_MUX
RFoutB Frequency
0
fVCO
1
fVCO / VCO_DIV
2
fFin
3
Reserved
0_DLY - Zero Delay Mode
When this mode is enabled, the VCO divider is put in the feedback path of the PLL so that the delay from input
to output of the device will be deterministic.
0_DLY
Phase Detector Input
0
Direct VCO or Fin signal.
1
Channel Divider output.
MODE[1:0] — Operating Mode
This field determines what mode the device is run in
MODE
Operational Mode
PLL
VCO
Fin Pin
0
Full Chip Mode
1
PLL Only Mode
Powered Up
Powered Up
Powered Down
Powered Up
Powered Down
2,3
Reserved
Powered Down
Reserved
Reserved
Reserved
PWDN_MODE - Powerdown Mode
This field power the device up and down. Aside from the traditional power up and power down, there is the
partial powerdown that powers down the PLL and VCO, but keeps the LDOs powered up to allow the device to
power up faster.
PWDN_MODE
CE Pin
0
X
Powered Up
1
X
Powered Down
2
X
Reserved
3
4
5
6
7
Device Status
X
Partial Powerdown
Low
Powered Down
High
Powered Up
X
Reserved
Low
Partial Powerdown
High
Powered Up
Powered Down
Low
Partial Powerdown
RESET - Register Reset
When this bit is enabled, the action of programming register R5 resets all registers to their default power on reset
status, otherwise the fields in register 5 can be programmed without resetting all the registers.
RESET
Action of Programming Register R5
0
Registers and state machines are operational.
1
Registers and state machines are reset, then this reset is automatically released.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
19
LMX2581
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
www.ti.com
REGISTER R4
PFD_DLY[2:0] — Phase Detector Delay
This word controls the minimum on time for the charge pump. The minimum setting often yields the best phase
detector spurs and integer mode PLL phase noise. Higher settings can be useful in reducing the delta sigma
noise of the modulator when dithering is enabled, but are not generally recommended if the phase detector
frequency exceeds 130 MHz. If unsure, default this word to zero.
PFD_DLY
Pulse Width
When Recommended
370 ps
Default
Use with a 2nd order modulator , when
dithering is disabled, or when the phase
detector frequency is >130 MHz.
0
1
760 ps
2
1130 ps
3
1460 ps
4
1770 ps
5
2070 ps
6
2350 ps
7
2600 ps
Consider these settings for a 3rd order
modulator when dithering is used.
FL_FRCE — Force Fastlock Conditions
This bit forces the fastlock conditions on provided that the FL_TOC field is greater than zero.
FL_FRCE
Fastlock Timeout Counter
0
1
Fastlock
0
Disabled
>0
Fastlock engaged as long as timeout counter is
counting down
0
Invalid State
>0
Always Engaged
FL_TOC[11:0] — Fastlock Timeout Counter
This field controls the timeout counter used for fastlock.
FL_TOC
Fastlock Timeout Counter
Comments
0
Disabled
Fastlock Disabled
1
2 x Reference Cycles
2
2 x 2 x Reference cycles
...
4095
20
Fastlock engaged as long as timeout counter is
counting down
2 x 4095 x Reference cycles
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
LMX2581
www.ti.com
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
FL_CPG[4:0] — Fastlock Charge Pump Gain
This bit determines the charge pump current that is active during fastlock.
FL_CPG
Fastlock Current
0
TRI-STATE
1
1X
2
2X
..
...
31
31X
CPG_BLEED[5:0]
The CPG bleed field is for advanced users who want to get the lowest possible integer boundary spur. The
impact of this bit is on the order of 2 dB. For users who do not care about this, the recommendation is to default
this field to zero.
User Type
Basic User
Advanced User
FRAC_ORDER
CPG
CPG Bleed Recommendation
X
X
0
<2
X
0
X
< 4X
0
4X ≤ CPG < 12X
2
12X ≤ CPG
4
>1
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
21
LMX2581
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
www.ti.com
REGISTER R3
VCO_DIV[4:0] — VCO Divider Value
This field determines the value of the VCO divider. Note that the this divider can be bypassed with the
OUTA_MUX and OUTB_MUX fields.
VCO_DIV
VCO Divider Value
0
2
1
4
2
6
3
8
4
10
...
...
18
38
20 - 31
Invalid State
OUTB_PWR[5:0] — RFoutB Output Power
This field controls the output power for the RFoutB output.
OUTB_PWR
RFoutB Power
0
Minimum
...
...
47
Maximum
48 – 63
Reserved
OUTA_PWR[5:0] — RFoutA Output Power
This field controls the output power for the RFoutA output.
OUTA_PWR
RFout Power
0
Minimum
...
...
47
Maximum
48 – 63
Reserved.
OUTB_PD — RFoutB Powerdown
This bit powers down the RFoutB output.
OUTB_PD
RFoutB
0
Normal Operation
1
Powered Down
OUTA_PD — RFoutA Powerdown
This bit powers down the RFoutA output.
22
OUTA_PD
RFoutA
0
Normal Operation
1
Powered Down
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
LMX2581
www.ti.com
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
REGISTER R2
OSC_2X — OSCin Doubler
This bit controls the doubler for the OSCin frequency.
OSC_2X
OSCin Doubler
0
Disabled
1
Enabled
CPP - Charge Pump Polarity
This bit sets the charge pump polarity. Note that the internal VCO has a negative tuning gain, so it should be set
to negative gain with the internal VCO enabled.
CPP
Charge Pump Polarity
0
Positive
1
Negative (Default)
PLL_DEN[21:0] — PLL Fractional Denominator
These fields control the denominator for the PLL fraction. Note that 0 is only permissible in integer mode.
PLL
_
DEN
PLL_DEN[21:0]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
...
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4194
303
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
23
LMX2581
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
www.ti.com
REGISTER R1
CPG[4:0] — PLL Charge Pump Gain
This bit determines the charge pump current that used during steady state operation
CPG
Charge Pump Current
0
TRI-STATE
1
1X
2
2X
..
...
31
31X
Note that if the CPG setting is 400 µA or lower, then the CPG_BLEED field needs to be set to 0.
VCO_SEL[1:0] - VCO Selection
These fields allow the user to specify which VCO the frequency calibration starts at. If uncertain, program this bit
to 0 to start at the lowest frequency VCO core. A programming setting of 3 (VCO 4) should not be used if
switching to a frequency below 2.2 GHz.
VCO_SEL
VCO Selection
0
VCO 1
(Lowest Frequency)
1
VCO 2
2
VCO 3
3
VCO 4
(Highest Frequency)
FRAC_ORDER[2:0] — PLL Delta Sigma Modulator Order
This field sets the order for the fractional engine
FRAC_ORDER
Modulator Order
0
Integer Mode
1
1st Order Modulator
2
2nd Order Modulator
3
3rd Order Modulator
4-7
Reserved
PLL_R[7:0] — PLL R divider
This field sets the value that divides the OSCin frequency.
PLL_R
24
PLL_R Divider Value
0
256
1
1 (bypass)
...
...
255
255
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
LMX2581
www.ti.com
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
REGISTER R0
Register R0 controls the frequency of the device. Also, unless disabled by setting NO_FCAL = 1, the action of
writing to the R0 register triggers a frequency calibration for the internal VCO.
ID - Part ID Readback
When this bit is set, the part ID is readback from the device. Consult the Functional Description for more details.
ID
Readback Mode
0
Register
1
Part ID
FRAC_DITHER[1:0] — PLL Fractional Dithering
This bit sets the dithering mode. When the fractional numerator is zero, it is recommended, although not
required, to set the FRAC_DITHER mode to disabled for the best possible spurs. Doing this shuts down the
fractional circuitry and eliminates fractional spurs for these frequencies. This is the reason why the
FRAC_DITHER word is in the R0 register, so that it can be set correctly for every frequency if this setting
changes.
FRAC_DITHER
Dithering Mode
0
Weak
1
Medium
2
Strong
3
Disabled
NO_FCAL — Disable Frequency Calibration
Normally, when the R0 register is written to, a frequency calibration for the internal VCO is triggered. However,
this feature can be disabled. If the frequency is changed, then this frequency calibration is necessary for the
internal VCO.
NO_FCAL
VCO Frequency Calibration
0
Done upon write to R0 Register
1
Not done on write to R0 Register
PLL_N - PLL Feedback Divider Value
This is the feedback divider value for the PLL. There are some restrictions on this depending on the modulator
order.
PLL_N
PLL_N[11:0]
<7
Invalid state
7
Possible only in integer mode or with a 1st order modulator
8-9
Possible in integer mode, 1st order modulator, or 2nd order modulator
10-13
Possible only in integer mode, 1st order modulator, 2nd order modulator, or 3rd order modulator
14
0
0
0
0
0
0
0
0
1
1
1
0
...
...
...
...
...
...
...
...
...
...
...
...
...
4095
1
1
1
1
1
1
1
1
1
1
1
1
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
25
LMX2581
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
www.ti.com
PLL_NUM[21:12] and PLL_NUM[11:0] — PLL Fractional Numerator
These fields control the numerator for the PLL fraction.
PLL
_
NU
M
PLL_NUM[21:12]
PLL_NUM[11:0]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
...
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4095
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
4096
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
...
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4194
303
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
26
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
LMX2581
www.ti.com
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
APPLICATIONS INFORMATION
VCO Digital Calibration
The VCO has four cores, VCO 1, VCO 2, VCO 3, and VCO 4. Each of these 4 cores has 256 different frequency
bands. Band 255 is the lowest frequency for a given core and Band 0 is the highest frequency. When the
frequency is changed, the digital VCO goes through the following VCO calibration:
1. Depending on the status of the VCO_SEL field, the starting VCO core is selected.
2. The algorithm starts counting at the default band in this core as determined by the VCO_CAPCODE value.
3. Based on the what the actual VCO output is compared to the target VCO output the VCO increments or
decrements the CAPCODE.
4. Repeat step 3 until either the VCO is locked or the VCO is at VCO_CAPCODE = 0 or 255
5. If not locked, then choose the next appropriate VCO if possible and return to step 3. If not possible, the
calibration is done.
A good starting point is to set VCO_SEL =2 for VCO 3 and set VCO_SEL_MODE = 1 to start at the selected
core. If there is the potential of switching the VCO from a frequency above 3 GHz directly to a frequency below
2.2 GHz, VCO_SEL_MODE can not be set to 0. In this case, VCO_SEL_MODE can still be set to 1 to select a
starting core, but the starting core specified by VCO_SEL can not be VCO 4.
The digital calibration time can be dramatically improved by giving the VCO guidance of which VCO core and
which VCO_CAPCODE to start with. Even if the wrong VCO core is chosen, which could happen near the
boundary of two cores, this calibration time is improved. For situations where the frequency change is small, the
device can be programmed to automatically start at the last VCO core used. For applications where the
frequency change is relatively small, the best VCO calibration time can often be achieved by setting the
VCO_SEL_MODE to choose the last VCO core that was used.
Optimizing the RFoutA and RFoutB Pins
Choosing the Proper Pull-Up Component
The first decision is to whether to use a resistor or inductor for a pull up.
• The resistor pull-up involves placing a 50 Ω resistor to the power supply on each side, which makes the
output impedance easy to match to and close to 50 Ω. However, it is higherr current for the same output
power, and the maximum possible output power is more limited. For this method, the OUTx_PWR setting
should be kept about 30 or less (for a 3.3 volt supply) to avoid saturation.
• The inductor pull-up involves placing an inductor to the power supply. This inductor should look like high
impedance at the frequency of interest. This method offers higher output power for the same current and
higher maximum output power. The output power is about 3 dB higher for the same OUTx_PWR setting than
the resistor pull-up. Because the output impedance will be very high and poorly matched, it is recommended
to either keep traces short or AC couple this into a pad for better impedance matching.
If an output is partially used or unused, then treat this as follows:
• If the output is unused, then power it down in software and no external components are necessary.
• If only one side of the differential output is used, include the pull-up component and terminate the unused
side such that the impedance as seen by this pin looks similar to the impedance as seen by the used side.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
27
LMX2581
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
www.ti.com
Choosing the Best Setting for the RFoutA_PWR and RFoutB_PWR Fields
The following table shows the impact of the RFoutA_PWR and RFoutB_PWR on the output. Note that THIS IS
THE RELATIVE OUTPUT POWER, NOT THE ACTUAL VALUE OF THE OUTPUT POWER. All settings are
normalized to the case of RFoutX_PWR = 15, which typically yields the optimal noise floor. The relative currents
are pretty much consistent regardless of the pull-up component used. Note that for the resistive pull-up, setting
OUTx_PWR to greater than 30 does not improve the output power, but it draws more current. So settings for
OUTx_PWR for the resistive load are not recommended to go much above 30. These numbers are typical for a
3.3 volt supply.
OUTx_PWR
RELATIVE Current (mA)
RELATIVE Output Power for
Resistive Pull-Up (dBm)
RELATIVE Output Power for
Inductor Pull-Up (dBm)
0
−16
− 9.0
− 9.0
5
− 11
− 4.6
− 4.6
10
−5
−2.0
−2.0
15
0
0
0
20
+5
+ 1.4
+ 1.5
25
+10
+ 2.1
+ 2.8
30
+15
+ 2.4
+ 3.9
35
+20
+ 2.2
+ 4.8
40
+25
+ 1.9
+ 5.4
45
+30
+ 1.4
+5.9
Using External VCO Mode
The LMX2581 allows the user to use an external VCO by using the Fin pin and selecting the external VCO mode
for the MODE field. Because this is software selectable, the user can have a setup that switches between the
external and internal VCO. Because the Fin pin is close to the RFoutA and RFoutB pins, some care needs to be
taken to minimize board crosstalk when both an external VCO and an output buffer is used. If only one output
buffer is required, it is recommended to use the RFoutB output because it is physically farther from the Fin pin
and therefore will have less board related crosstalk. When using external VCO, it may be necessary to change
the phase detector polarity (CPP).
28
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
LMX2581
www.ti.com
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
Optimization of Spurs
The behaviors of the LMX2581 spurs vary with the application and the particular spur of interest. To get the best
possible spurs, it sometimes involves actual bench measurements and even trial and error. That being said,
there are resources available for better understanding of these spurs and to make the process of optimizing
spurs more systematic. Application note 1879, the clock design tool simulation for the LMX2581, and the
following table give good background on the LMX2581 fractional spurs and the following sections also give some
part-specific tips on how to optimize spurs.
Spur Type
Offset
Phase Detector Spur
Fpd
1.
2.
3.
Reduce Phase Detector Frequency
Decrease PFD_DLY
Decrease CPG_BLEED
Integer Boundary Spur
Fpd/Fden*min{Fnum,Fden/Fnum}
1.
2.
Reduce Phase Detector Frequency
At OSCin Pin, ensure good slew rate, signal integrity, and that
this pin sees about 50 ohms looking outwards.
Primary Fractional Spur
Fpd/Fden
1.
2.
Decrease Loop Bandwidth
Change Modulator Order
Fpd/Fden/k, k=2,3, or 6
1.
2.
3.
4.
Use Dithering
Use Larger Equivalent Fractions
Reduce Modulator Order
Eliminate factors of 2 or 3 in denominator (see AN-1879)
Sub-Fractional Spur
Ways to Reduce
Phase Detector Spur
The phase detector spur occurs at an offset from the carrier equal to the phase detector frequency, Fpd. They
have a general increasing tendency as the phase detector frequency increases, although this trend stops around
100 MHz. To minimize this spur, considering using a smaller value for PFD_DLY, smaller value for CPG_BLEED,
and a lower phase detector frequency. In some cases where the loop bandwidth is very wide relative to the
phase detector frequency, one might see some benefit to using a narrower loop bandwidth or adding poles to the
loop filter, but otherwise these spurs are not impacted much by these things.
Fractional Spur - Integer Boundary Spur
This spur occurs at an offset equal to the difference between the VCO frequency and the closest integer channel
for the VCO. For instance, if the phase detector frequency is 100 MHz and the fraction is 3/100, then the integer
boundary spur would be at 3 MHz offset. If this spur is outside the loop bandwidth, which it usually is, the largest
factor influencing this spur is the phase detector frequency. Lowering the phase detector frequency will reduce
this spur significantly. If the phase detector frequency is reduced, charge pump gain should be changed to
compensate for this, or the loop filter should be re-designed if this is not possible. If it is closer to the loop
bandwidth, a lower loop bandwidth may also improve this spur. This spur can change between the different VCO
cores, with VCO 3 having the best performance for this spur. The signal and termination at the OSCin pin may
also have a small impact on this spur. Fractional settings such as FRAC_DITHER, FRAC_ORDER, and larger
equivalent fractions (i.e. 1000000/4000000 instead of 1/4) may impact this spur by a few dB, but the impact is
typically not very much.
Fractional Spur - Primary Fractional Spurs
These spurs occur at multiples of Fpd/Fden and are not the integer boundary spur. For instance, if the phase
detector frequency is 100 MHz and the fraction is 3/100, the primary fractional spurs would be at
1,2,4,5,6,...MHz. These are impacted by the loop filter and modulator order
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
29
LMX2581
SNAS601D – AUGUST 2012 – REVISED APRIL 2013
www.ti.com
Fractional Spur - Sub-Fractional Spurs
These spurs appear at a fraction of Fpd/Fden and depend on modulator order. With the first order modulator,
there are no sub-fractional spurs. The second order modulator can produce 1/2 sub-fractional spurs if the
denominator is even. A third order modulator can produce sub-fractional spurs at 1/2,1/3, or 1/6 of the offset,
depending if it is divisible by 2 or 3. For instance, if the phase detector frequency is 100 MHz and the fraction is
3/100, we would expect no sub-fractional spurs for a first order modulator, sub-fractional spurs at multiples of 1.5
MHz for a 2nd or 3rd order modulator.
Aside from strategically choosing the fractional denominator and using a lower order modulator, another tactic to
eliminate these spurs is to use dithering and express the fraction in larger equivalent terms (i.e.
1000000/4000000 instead of 1/4). However, dithering can also add phase noise, so if dithering is used, this
needs to be managed with the various levels of it has and the PFD_DLY word to get the best possible
performance.
30
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: LMX2581
PACKAGE OPTION ADDENDUM
www.ti.com
11-Mar-2013
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package Qty
Drawing
Eco Plan
Lead/Ball Finish
(2)
MSL Peak Temp
Op Temp (°C)
Top-Side Markings
(3)
(4)
LMX2581SQ/NOPB
ACTIVE
WQFN
RTV
32
1000
Green (RoHS
& no Sb/Br)
CU SN
Level-3-260C-168 HR
X2581
LMX2581SQE/NOPB
ACTIVE
WQFN
RTV
32
250
Green (RoHS
& no Sb/Br)
CU SN
Level-3-260C-168 HR
X2581
LMX2581SQX/NOPB
ACTIVE
WQFN
RTV
32
4500
Green (RoHS
& no Sb/Br)
CU SN
Level-3-260C-168 HR
X2581
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
(4)
Only one of markings shown within the brackets will appear on the physical device.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
Addendum-Page 1
Samples
PACKAGE MATERIALS INFORMATION
www.ti.com
26-Mar-2013
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
Package Package Pins
Type Drawing
LMX2581SQ/NOPB
WQFN
RTV
32
LMX2581SQE/NOPB
WQFN
RTV
LMX2581SQX/NOPB
WQFN
RTV
SPQ
Reel
Reel
A0
Diameter Width (mm)
(mm) W1 (mm)
B0
(mm)
K0
(mm)
P1
(mm)
W
Pin1
(mm) Quadrant
1000
178.0
12.4
5.3
5.3
1.3
8.0
12.0
Q1
32
250
178.0
12.4
5.3
5.3
1.3
8.0
12.0
Q1
32
4500
330.0
12.4
5.3
5.3
1.3
8.0
12.0
Q1
Pack Materials-Page 1
PACKAGE MATERIALS INFORMATION
www.ti.com
26-Mar-2013
*All dimensions are nominal
Device
Package Type
Package Drawing
Pins
SPQ
Length (mm)
Width (mm)
Height (mm)
LMX2581SQ/NOPB
WQFN
RTV
32
1000
213.0
191.0
55.0
LMX2581SQE/NOPB
WQFN
RTV
32
250
213.0
191.0
55.0
LMX2581SQX/NOPB
WQFN
RTV
32
4500
367.0
367.0
35.0
Pack Materials-Page 2
MECHANICAL DATA
RTV0032A
SQA32A (Rev B)
www.ti.com
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products
Applications
Audio
www.ti.com/audio
Automotive and Transportation
www.ti.com/automotive
Amplifiers
amplifier.ti.com
Communications and Telecom
www.ti.com/communications
Data Converters
dataconverter.ti.com
Computers and Peripherals
www.ti.com/computers
DLP® Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
Energy and Lighting
www.ti.com/energy
Clocks and Timers
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
OMAP Applications Processors
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2013, Texas Instruments Incorporated