ADAM-5510KW/TCP ADAM-5510EKW/TP 4-slot SoftLogic Controller with Ethernet 8-slot SoftLogic Controller with Ethernet Features 10/100Base-T Ethernet interface Built-in Modbus/TCP server Supports Modbus/TCP client Supports Modbus/RTU Master Supports Modbus/RTU Slave Supports Multiprog via Ethernet IEC-61131-3 standard package Supports LD/FB/SFC/IL/ST languages Cross-language compiling program 8 I/O slots base and handles up to 128 local I/O points Supports AI/AO/DI/DO/Counter function blocks RoHS COMPLIANT 2002/95/EC Introduction The ADAM-5510EKW/TP is an Ethernet-enabled SoftLogic Controller. In addition to the features of ADAM-5510KW and ADAM-5510EKW, the ADAM-5510EKW/TP has Ethernet features including Modbus/TCP Server, Modbus/TCP Client and Multiprog via Ethernet functions. Therefore, users can easily and quickly complete their programming based on Ethernet architecture. Standard Modbus Interface For advanced system integration, the ADAM-5510EKW/TP supports not only Modbus/RTU Master and Slave functions via serial ports, but also the Modbus/TCP Client to retrieve data from remote I/O, and Modbus/TCP Server to send data back to the HMI/SCADA Software via Ethernet port. Furthermore, the ADAM-5510EKW/TP allows users to remotely maintain multiple ADAM-5510EKW/TP controllers by running Multiprog programming software via Ethernet. Specifications Control System Power CPU I/O Capacity 16-bit microprocessor 4 slots (ADAM-5510KW/TCP) 8 slots (ADAM-5510EKW/TP) Power, CPU, communication, and battery Flash disk: 512 KB Flash memory: 768 KB Flash ROM: 256 KB RAM: 768 KB SRAM, 17 KB with battery backup ROM-DOS Yes Yes LED Indicators Memory Operating System Real-time Clock Watchdog Timer Power Consumption Power Input General Certifications Connectors Communications (Ethernet) Dimensions Medium Transmission Speed Enclosure Mounting Cat.5 cable with RJ-45 connectors 100 Mbps (10/100Base-T) Communications (Serial) Max. Nodes Medium Protocols Transmission Speed Protection 32 (in RS-485 daisy-chain network) RS-485 (2-wire) Modbus/RTU, Modbus/TCP (Max. 8 Connection with Modbus/TCP) 9,600, 19,200 and 38,400 bps Power Input Communication Line Isolation Power Reversal Protection 3,000 VDC 2,500 VDC (COM2 only) Yes Programmable Automation Controllers 4 W @ 24 Vdc (not including I/O modules) Unregulated 10 ~ 30 V Unregulated 10 ~ 30 VDC Environment CE, FCC class A 1 x DB9-M for RS-232/485 (COM1) 1 x Screw terminal for RS-485 (COM2) 1 x DB9-F for RS-232/Programming (COM3) 1 x DB9-M for RS-232/485 (COM4) 1 x Screw-terminal for power input 1 x RJ-45 for LAN 4-slot: 231 x 110 x 75 mm 8-slot: 355 x 110 x 75 mm ABS+PC DIN 35 rail, stack, wall Humidity 5 ~ 95%, non-condensing Operating Temperature - 10 ~ 70° C (14 ~ 158° F) Storage Temperature - 25 ~ 85° C (-13 ~ 185° F) Ordering Information ADAM-5510KW/TCP ADAM-5510EKW/TP MPROG-BAS33 4-slot Ethernet-enabled SoftLogic Controller 8-slot Ethernet-enabled SoftLogic Controller KW Multiprog v3.3 for WinNT/2K/XP (128-byte I/O)