ACT–F128K8 High Speed 1 Megabit Monolithic FLASH CIRCUIT TECHNOLOGY www.aeroflex.com Features ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Low Power Monolithic 128K x 8 FLASH TTL Compatible Inputs and CMOS Outputs Access Times of 60, 70, 90, 120 and 150ns +5V Programing, +5V Supply 100,000 Erase / Program Cycles Low Standby Current Page Program Operation and Internal Program Control Time Supports Full Chip Erase Embedded Erase and Program Algorithms Supports Full Chip Erase MIL-PRF-38534 Compliant Circuits Available ■ ■ Industry Standard Pinouts Packaging – Hermetic Ceramic 32 Lead, 1.6" x .6" x .20" Dual-in-line Package (DIP), Aeroflex code# "P4" ● 32 Lead, .82" x .41" x .125" Ceramic Flat Package (FP), Aeroflex code# "F6" ● 32 Lead, .82" x .41" x .132" Ceramic Flat Package (FP Lead Formed), Aeroflex code# "F7" ● ■ Sector Architecture ● ● ■ ■ 8 Equal size sectors of 16K bytes each Any Combination of Sectors can be erased with one command sequence. Commercial, Industrial and Military Temperature Ranges DESC SMD Pending 5962-96690 (P4,F6,F7) Block Diagram – DIP (P4) & Flat Packages (F6,F7) CE WE OE A0 – A16 Vss 512Kx8 Vcc 8 I/O0-7 Pin Description I/O0-7 Data I/O A0–16 Address Inputs WE Write Enable CE Chip Enable OE Output Enable VCC Power Supply VSS Ground NC Not Connected General Description The ACT–F128K8 is a high speed, 1 megabit CMOS monolithic Flash module designed for full temperature range military, space, or high reliability applications. This device is input TTL and output CMOS compatible. The command register is written by bringing write enable (WE) and chip enable (CE) to a logic low level and output enable (OE) to a logic high level. Reading is accomplished when WE is high and CE, OE are both low, see Figure 9. Access time grades of 60ns, 70ns, 90ns, 120ns and 150ns maximum are standard. The ACT–F128K8 is available in a choice of eroflex Circuit Technology - Advanced Multichip Modules © SCD1676 REV A 5/6/98 General Description, Cont’d, second. Erase is accomplished by executing the erase command sequence. This will invoke the Embedded Erase Algorithm which is an internal algorithm that automatically preprograms the array, (if it is not already programmed before) executing the erase operation. During erase, the device automatically times the erase pulse widths and verifies proper cell margin. Also the device features a sector erase architecture. The sector mode allows for 16K byte blocks of memory to be erased and reprogrammed without affecting other blocks. The ACT-F128K8 is erased when shipped from the factory. The device features single 5.0V power supply operation for both read and write functions. lnternally generated and regulated voltages are provided for the program and erase operations. A low VCC detector automatically inhibits write operations on the loss of power. The end of program or erase is detected by Data Polling of D7 or by the Toggle Bit feature on D6. Once the end of a program or erase cycle has been completed, the device internally resets to the read mode. All bits of each die, or all bits within a sector of a die, are erased via Fowler-Nordhiem tunneling. Bytes are programmed one byte at a time by hot electron injection. A DESC Standard Military Drawing (SMD) number is pending. hermetically sealed ceramic packages; a 32 lead .82" x .41" x .125" flat package in both formed or unformed leads or a 32 pin 1.6"x.60" x.20" DIP package for operation over the temperature range -55°C to +125°C and military environmental conditions. The flash memory is organized as 128Kx8 bits and is designed to be programmed in-system with the standard system 5.0V Vcc supply. A 12.0V VPP is not required for write or erase operations. The device can also be reprogrammed with standard EPROM programmers (with the proper socket). The standard ACT–F128K8 offers access times between 60ns and 150ns, allowing operation of high-speed microprocessors without wait states. To eliminate bus contention, the device has separate chip enable (CE), write enable (WE) and output enable (OE) controls. The ACT–F128K8 is command set compatible with JEDEC standard 1 Mbit EEPROMs. Commands are written to the command register using standard microprocessor write timings. Register contents serve as input to an internal state-machine which controls the erase and programming circuitry. Write cycles also internally latch addresses and data needed for the programming and erase operations. Reading data out of the device is similar to reading from 12.0V Flash or EPROM devices. The ACT–F128K8 is programmed by executing the program command sequence. This will invoke the Embedded Program Algorithm which is an internal algorithm that automatically times the program pulse widths and verifies proper cell margin. Typically, each sector can be programmed and verified in less than 0.3 Aeroflex Circuit Technology 2 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 z Absolute Maximum Ratings Parameter Symbol Range Units Case Operating Temperature TC -55 to +125 °C Storage Temperature Range TSTG -65 to +150 °C Supply Voltage Range VCC -2.0 to +7.0 V Signal Voltage Range (Any Pin Except A9) Note 1 VG -2.0 to +7.0 V Maximum Lead Temperature (10 seconds) 300 °C Data Retention 10 Years 100,000 Minimum Endurance (Write/Erase cycles) -2.0 to +14.0 VID A9 Voltage for sector protect, Note 2 V Note 1. Minimum DC voltage on input or I/O pins is -0.5V. During voltage transitions, inputs may undershoot VSS to -2.0v for periods of up to 20ns. Maximum DC voltage on input and I/O pins is VCC + 0.5V. During voltage transitions, inputs and I/O pins may overshoot to VCC + 2.0V for periods up to 20 ns. Note 2. Minimum DC input voltage on A9 is -0.5V. During voltage transitions, A9 may undershoot VSS to -2.0V for periods of up to 20ns. Maximum DC input voltage on A9 is +12.5V which may overshoot to 14.0V for periods up to 20ns. Normal Operating Conditions Symbol Parameter Minimum Maximum Units VCC Power Supply Voltage +4.5 +5.5 V VIH Input High Voltage +2.0 VCC + 0.5 V VIL Input Low Voltage -0.5 +0.8 V Tc Operating Temperature (Military) -55 +125 °C VID A9 Voltage for sector protect 11.5 12.5 V Capacitance (VIN= 0V, f = 1MHz, Tc = 25°C) Symbol CAD COE Parameter Maximum Units A0 – A16 Capacitance 15 pF OE Capacitance 15 pF CWE Write Enable Capacitance 15 pF CCE Chip Enable Capacitance 15 pF I/O0 – I/O7 Capacitance 15 pF CI/O Parameters Guaranteed but not tested DC Characteristics – CMOS Compatible (Vcc = 5.0V, Vss = 0V, Tc = -55°C to +125°C, unless otherwise indicated) Parameter Sym Speeds 60, 70, 90, 120 & 150ns Conditions Minimum Maximum Units Input Leakage Current ILI VCC = 5.5V, VIN = GND to VCC 10 µA Output Leakage Current ILO VCC = 5.5V, VIN = GND to VCC 10 µA Active Operating Supply Current for Read (1) ICC1 CE = VIL, OE = VIH, f = 5MHz 35 mA Active Operating Supply Current for Program or Erase (2) ICC2 CE = VIL, OE = VIH 50 mA Operating Standby Supply Current ICC3 VCC = 5.5V, CE = VIH, f = 5MHz 1.6 mA Output Low Voltage VOL IOL = +8.0 mA, VCC = 4.5V 0.45 V Output High Voltage VOH IOH = –2.5 mA, VCC = 4.5V Low Power Supply Lock-Out Voltage (4) VLKO 0.85 x VCC V 3.2 V Note 1. The Icc current listed includes both the DC operating current and the frequency dependent component (At 6 MHz). The frequency component typically is less than 2 mA/MHz, with OE at VIN. Note 2. Icc active while Embedded Algorithm (Program or Erase) is in progress. Note 3. DC Test conditions: VIL = 0.3V, VIH = VCC - 0.3V, unless otherwise indicated. Note 4. Parameter Guaranteed by design, but not tested. Aeroflex Circuit Technology 3 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 AC Characteristics – Read Only Operations (Vcc = 5.0V, Vss = 0V, Tc = -55°C to +125°C) Symbol Parameter –60 –70 –90 –120 –150 JEDEC Stand’d Min Max Min Max Min Max Min Max Min Max Read Cycle Time tAVAV tRC 60 70 90 120 150 Units ns Address Access Time tAVQV tACC 60 70 90 120 150 ns Chip Enable Access Time tELQV tCE 60 70 90 120 150 ns Output Enable to Output Valid tGLQV tOE 30 35 40 50 55 ns Chip Enable to Output High Z (1) tEHQZ tDF 20 20 25 30 35 ns Output Enable High to Output High Z(1) tGHQZ tDF 35 ns Output Hold from Address, CE or OE Change, Whichever is First tAXQX tOH 20 0 20 0 25 0 30 0 0 ns Note 1. Guaranteed by design, but not tested AC Characteristics – Write/Erase/Program Operations, WE Controlled (Vcc = 5.0V, Vss = 0V, Tc = -55°C to +125°C) Symbol Parameter –60 –70 –90 –120 –150 JEDEC Stand’d Min Max Min Max Min Max Min Max Min Max Units Write Cycle Time tAVAC tWC 60 70 90 120 150 ns Chip Enable Setup Time tELWL tCE 0 0 0 0 0 ns Write Enable Pulse Width tWLWH tWP 30 35 45 50 50 ns Address Setup Time tAVWL tAS 0 0 0 0 0 ns Data Setup Time tDVWH tDS 30 30 45 50 50 ns Data Hold Time tWHDX tDH 0 0 0 0 0 ns Address Hold Time tWLAX tAH 45 45 45 50 50 ns Write Enable Pulse Width High tWHWL tWPH 20 20 20 20 20 ns Duration of Byte Programming Operation Typ = 16 µs tWHWH1 Sector Erase Time tWHWH2 Read Recovery Time before Write 14 TYP 14 TYP 14 TYP 14 TYP 14 TYP 60 tGHWL tVCE Vcc Setup Time 60 60 60 Sec 0 0 0 0 0 µs 50 50 50 50 50 µs Chip Programming Time tWHWH3 Chip Erase Time 60 µs 12.5 12.5 12.5 12.5 12.5 Sec 120 120 120 120 120 Sec AC Characteristics – Write/Erase/Program Operations, CE Controlled (Vcc = 5.0V, Vss = 0V, Tc = -55°C to +125°C) Parameter Symbol –60 –70 –90 –120 –150 JEDEC Stand’d Min Max Min Max Min Max Min Max Min Max Write Cycle Time tAVAC tWC 60 70 90 Write Enable Setup Time tWLEL tWS 0 0 0 Chip Enable Pulse Width tELEH tCP 30 35 45 120 Units 150 ns 0 0 ns 50 50 ns Address Setup Time tAVEL tAS 0 0 0 0 0 ns Data Setup Time tDVEH tDS 30 30 45 50 50 ns Data Hold Time tEHDX tDH 0 0 0 0 0 ns Address Hold Time tELAX tAH 45 45 45 50 50 ns Chip Select Pulse Width High tEHEL tCPH 20 20 20 20 20 Duration of Byte Programming tWHWH1 Sector Erase Time tWHWH2 Read Recovery Time tGHEL Chip Programming Time Chip Erase Time Aeroflex Circuit Technology tWHWH3 4 ns 14 TYP 14 TYP 14 TYP 14 TYP 14 TYP 60 0 60 0 60 0 60 0 60 0 µs Sec ns 12.5 12.5 12.5 12.5 12.5 Sec 120 120 120 120 120 Sec SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 programming, the device will draw active current until the operation is completed. Device Operation The ACT-F128K8 Monolithic module is composed of one, 1 megabit flash EEPROM. Programming of the ACT-F128K8 is accomplished by executing the program command sequence. The program algorithm, which is an internal algorithm, automatically times the program pulse widths and verifies proper cell status. Sectors can be programed and verified in less than 0.3 second. Erase is accomplished by executing the erase command sequence. The erase algorithm, which is internal, automatically preprograms the array if it is not already programed before executing the erase operation. During erase, the device automatically times the erase pulse widths and verifies proper cell status. The entire memory is typically erased and verified in 3 seconds (if pre-programmed). The sector mode allows for 16K byte blocks of memory to be erased and reprogrammed without affecting other blocks. WRITE Device erasure and programming are accomplished via the command register. The contents of the register serve as input to the internal state machine. The state machine outputs dictate the function of the device. The command register itself does not occupy an addressable memory location. The register is a latch used to store the command, along with address and data information needed to execute the command. The command register is written by bringing WE to a logic low level (VIL), while CE is low and OE is at VIH. Addresses are latched on the falling edge of WE or CE, whichever happens later. Data is latched on the rising edge of the WE or CE whichever occurs first. Standard microprocessor write timings are used. Refer to AC Program Characteristics and Waveforms, Figures 3, 8 and 13. Bus Operation Command Definitions READ The ACT-F128K8 has two control functions, both of which must be logically active, to obtain data at the outputs. Chip Enable (CE) is the power control and should be used for device selection. Output-Enable (OE) is the output control and should be used to gate data to the output pins of the chip selected. Figure 7 illustrates AC read timing waveforms. Device operations are selected by writing specific address and data sequences into the command register. Table 3 defines these register command sequences. READ/RESET COMMAND The read or reset operation is initiated by writing the read/reset command sequence into the command register. Microprocessor read cycles retrieve array data from the memory. The device remains enabled for reads until the command register contents are altered. The device will automatically power-up in the read/reset state. In this case, a command sequence is not required to read data. Standard microprocessor read cycles will retrieve array data. The device will automatically power-up in the read/reset state. In this case, a command sequence is not required to read data. Standard Microprocessor read cycles will retrieve array data. This default value ensures that no spurious alteration of the memory content occurs during the power transition. Refer to the AC Read Characteristics and Figure 7 for the specific timing parameters. OUTPUT DISABLE With Output-Enable at a logic high level (VIH), output from the device is disabled. Output pins are placed in a high impedance state. STANDBY MODE The ACT-F128K8 has two standby modes, a CMOS standby mode (CE input held at Vcc + 0.5V), where the current consumed is typically less than 400 µA; and a TTL standby mode (CE is held VIH) is approximately 1 mA. In the standby mode the outputs are in a high impedance state, independent of the OE input. If the device is deselected during erasure or Table 2 – Sector Addresses Table Table 1 – Bus Operations Operation CE OE WE A0 A1 A9 I/O A14 Address Range READ L L H A0 A1 A9 DOUT SA0 0 0 0 00000h – 03FFFh STANDBY H X X X HIGH Z SA1 0 0 1 04000h – 07FFFh HIGH Z SA2 0 1 0 08000h – 0BFFFh SA3 0 1 1 0C000h – 0FFFFh SA4 1 0 0 10000h – 13FFFh SA5 1 0 1 14000h – 17FFFh SA6 1 1 0 18000h – 1BFFFh SA7 1 1 1 1C000h – 1FFFFh X OUTPUT DISABLE L H H X WRITE L H L A0 A1 A9 ENABLE SECTOR PROTECT VERIFY SECTOR PROTECT Aeroflex Circuit Technology L L VID L L H X L X X X H X VID VID A16 A15 DIN X Code 5 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 Table 3 — Commands Definitions Command Sequence Read/Reset Bus Write Cycle First Bus Write Second Bus Write Third Bus Write Cycle Cycle Cycle Fourth Bus Read/Write Cycle Req’d Addr Data Addr Data Addr Data Addr Data 4 5555H AAH 2AAAH 55H 5555H F0H RA RD Fifth Bus Write Sixth Bus Write Cycle Cycle Addr Data Addr Data Byte Program 6 5555H AAH 2AAAH 55H 5555H A0H PA PD Chip Erase 6 5555H AAH 2AAAH 55H 5555H 80H 5555H AAH 2AAAH 55H 5555H 10H Sector Erase 6 5555H AAH 2AAAH 55H 5555H 80H 5555H AAH 2AAAH 55H SA 30H NOTES: 1. Address bit A15 = X = Don't Care. Write Sequences may be initiated with A15 in either state. 2. Address bit A16 = X = Don't Care for all address commands except for Program Address (PA) and Sector Address (SA). 3. RA = Address of the memory location to be read PA = Address of the memory location to be programmed. Addresses are latched on the falling edge of the WE pulse. SA = Address of the sector to be erased. The combination of A16, A15, A14 will uniquely select any sector. 4. RD = Data read from location RA during read Operation. PD = Data to be programmed at location PA. Data is latched on the rising edge of WE. BYTE PROGRAMING device prior to erase. Upon executing the Embedded Erase Algorithm command sequence (Figure 4) the device will automatically program and verify the entire memory for an all zero data pattem prior to electrical erase. The erase is performed concurrently on all sectors at the same time . The system is not required to provide any controls or timings during these operations. Note: Post Erase data state is all "1"s. The automatic erase begins on the rising edge of the last WE pulse in the command sequence and terminates when the data on D7 is "1" (see Write Operation Status section - Table 3) at which time the device retums to read mode. See Figures 4 and 9. The device is programmed on a byte-byte basis. Programming is a four bus cycle operation. There are two "unlock" write cycles. These are followed by the program set-up command and data write cycles. Addresses are latched on the falling edge of CE or WE, whichever occurs later, while the data is latched on the rising edge of CE or WE whichever occurs first. The rising edge of CE or WE (whichever happens first) begins programming using the Embedded Program Algorithm. Upon executing the program algorithm command sequence the system is not required to provide further controls or timings. The device will automatically provide adequate internally generated program pulses and verify the programmed cell. The automatic programming operation is completed when the data on D7 (also used as Data Polling) is equivalent to data written to this bit at which time the device returns to the read mode and addresses are no longer latched. Therefore, the device requires that a valid address be supplied by the system at this particular instance of time for Data Polling operations. Data Polling must be performed at the memory location which is being programmed. Any commands written to the chip during the Embedded Program Algorithm will be ignored. Programming is allowed in any sequence and across sector boundaries. Beware that a data "0" cannot be programmed back to a “1". Attempting to do so may cause the device to exceed programming time limits (D5 = 1) or result in an apparent success, according to the data polling algorithm, but a read from reset/read mode will show that the data is still “0". Only erase operations can convert “0"s to “1"s. Figure 3 illustrates the programming algorithm using typical command strings and bus operations. SECTOR ERASE Sector erase is a six bus cycle operation. There are two "unlock" write cycles. These are followed by writing the "setup" command. Two more "unlock" write cycles are then followed by the sector erase command. The sector address (any address location within the desired sector) is latched on the falling edge of WE, while the command (30H) is latched on the rising edge of WE. After a time-out of 80µs from the rising edge of the last sector erase command, the sector erase operation will begin. Multiple sectors may be erased concurrently by writing the six bus cycle operations as described above. This sequence is followed with writes of the sector erase command to addresses in other sectors desired to be concurrently erased. The time between writes must be less than 80µs otherwise that command will not be accepted and erasure will start. It is recommended that processor interrupts be disabled during this time to guarantee this condition. The interrupts can be re-enabled after the last Sector Erase command is written. A time-out of 80µs from the rising edge of the last WE will initiate the execution of the Sector Erase command(s). If another falling edge of the WE occurs within the 80µs time-out window the timer is reset. (Monitor D3 to determine if the sector erase timer window is still open, see section D3, Sector Erase Timer.) Any commarid other than Sector Erase during this period will reset the device to read mode, ignoring the previous command string. In that case, restart the erase on those sectors and allow them to complete. CHIP ERASE Chip erase is a six bus cycle operation. There are two 'unlock' write cycles. These are followed by writing the “set-up” command. Two more “unlock” write cycles are then followed by the chip erase command. Chip erase does not require the user to program the Aeroflex Circuit Technology 6 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 POWER-UP WRITE INHIBIT Loading the sector erase buffer may be done in any sequence and with any number of sectors (0 to 7). Sector erase does not require the user to program the device prior to erase. The device automatically programs all memory locations in the sector(s) to be erased prior to electrical erase. When erasing a sector or sectors the remaining unselected sectors are not affected. The system is not required to provide any controls or timings during these operations. Post Erase data state is all "1"s. The automatic sector erase begins after the 80µs time out from the rising edge of the WE pulse for the last sector erase command pulse and terminates when the data on D7, Data Polling, is “1" (see Write Operatlon Status secton) at which time the device returns to read mode. Data Polling must be performed at an address within any of the sectors being erased. Figure 4 illustrates the Embedded Erase Algorithm. Power-up of the device with WE = CE = VIL and OE = VIH will not accept commands on the rising edge of WE. The internal state machine is automatically reset to the read mode on power-up. Write Operation Status D7 DATA POLLING The ACT-F128K8 features Data Polling as a method to indicate to the host that the internal algorithms are in progress or completed. During the program algorithm, an attempt to read the device will produce compliment data of the data last written to D7. Upon completion of the programming algorithm an attempt to read the device will produce the true data last written to D7. Data Polling is valid after the rising edge of the fourth WE pulse in the four write pulse sequence. During the erase algorithm, D7 will be "0" until the erase operation is completed. Upon completion data at D7 is "1". For chip erase, the Data Polling is valid after the rising edge of the sixth WE pulse in the six write pulse sequence. For sector erase, the Data Polling is Valid after the last rising edge of the sector erase WE pulse. The Data Polling feature is only active during the programming algorithm, erase algorithm, or sector erase time-out. See Figures 6 and 10 for the Data Polling specifications. Data Protection The ACT-F128K8 is designed to offer protection against accidental erasure or programming caused by spurious system level singles that may exist during power transitions. During power up the device automatically resets the internal state machine in the read mode. Also, with its control register architecture, alteration of the memory content only occurs after successful completion of specific multi-bus cycle command sequences. The device also incorporates several features to prevent inadvertent write cycles resulting from Vcc power-up and power-down transitions or system noise. LOW Vcc WRITE INHIBIT D6 TOGGLE BIT To avoid initiation of a write cycle during Vcc power-up and power-down, a write cycle is locked out for VCC less than 3.2V (typically 3.7V). If VCC < VLKO, the command register is disabled and all internal program/erase circuits are disabled. Under this condition the device will reset to read mode. Subsequent writes will be ignored until the Vcc level is greater than VLKO. It is the users responsibility to ensure that the control pins are logically correct to prevent unintentional writes when Vcc is above 3.2V. The ACT-F128K8 also features the "Toggle Bit" as a method to indicate to the host system that algorithms are in progress or completed. During a program or erase algorithm cycle, successive attempts to read data from the device will result in D6 toggling between one and zero. Once the program or erase algorithm cycle is completed, D6 Will stop toggling and valid data will be read on successive attempts. During programming the Toggle Bit is valid after the rising edge of the fourth WE pulse in the four write pulse sequence. For chip erase the Toggle Bit is valid after the rising edge of the sixth WE pulse in the six write pulse sequence. For Sector erase, the Toggle Bit is valid after the last rising edge of the sector erase WE pulse. The Toggle Bit is active during the sector time out. See Figure 1 and 5. WRITE PULSE GLITCH PROTECTION Noise pulses of less than 5ns (typical) on OE, CE or WE will not initiate a write cycle. LOGICAL INHIBIT Writing is inhibited by holding anyone of OE = VIL, CE = VIH or WE = VIH. To initiate a write cycle CE and WE must be logical zero while OE is a logical one. Aeroflex Circuit Technology 7 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 Table 4 — Hardware Sequence Flags In Progress Exceeding Time Limits Status D7 D6 Auto-Programming D7 Toggle 0 0 0 0 Toggle 0 0 1 Erase in Auto Erase 0 Toggle 0 1 1 Auto-Programming D7 Toggle 1 0 0 Programming in Auto Erase T0 Toggle 1 0 1 0 Toggle 1 1 1 Programming in Auto Erase Erase in Auto Erase D5 EXCEEDED TIMING LIMITS D2 – D0 Reserved for future use Reserved for future use Sector Protection Algorithims D5 will indicate if the program or erase time has exceeded the specified limits. Under these conditions D5 will produce a "1". The Program or erase cycle was not successfully completed. Data Polling is the only operation function of the device under this condition. The CE circuit will partially power down the device under these conditions by approximately 8 mA per chip. The OE and WE pins will control the output disable functions as shown in Table 1. To reset the device, write the reset command sequence to the device. This allows the system to continue to use the other active sectors in the device. SECTOR PROTECTION The ACT-F128K8 features hardware sector protection which will disable both program and erase operations to an individual sector or any group of sectors. To activate this mode, the programming equipment must force VID on control pin OE and address pin A9. The sector addresses should be set using higher address lines A16, A15, and A14. The protection mechanism begins on the falling edge of the WE pulse and is terminated with the rising edge of the same. It is also possible to verify if a sector is protected during the sector protection operation. This is done by setting CE = OE = VIL and WE = VIH (A9 remains high at VID). Reading the device at address location XXX2H, where the higher order addresses (A16, A15 and A14) define a particular sector, will produce 01H at data outputs D0 D7, for a protected sector. D4 - HARDWARE SEQUENCE FLAG If the device has exceeded the specified erase or program time and D5 is "1", then D4 Will indicate which step in the algorithm the device exceeded the limits. A "0" in D4 indicates in programming, a "1" indicates an erase. (See Table 4) D3 SECTOR ERASE TIMER SECTOR UNPROTECT The ACT-F128K8 also features a sector unprotect mode, so that a protected sector may be unprotected to incorporate any changes in the code. All sectors should be protected prior to unprotecting any sector. To activate this mode, the programming equipment must force VID on control pins OE, CE, and address pin A9. The address pins A6, A7, and A12 should be set to VIH, and A6 = VIL. The unprotection mechanism begins on the falling edge of the WE pulse and is terminated with the rising edge of the same. It is also possible to determine if a sector is unprotected in the system by writing the autoselect command. Performing a read operation at address location XXX2H, where the higher order addresses (A16, A15, and A14) define a particular sector address, will produce 00H at data outputs (D0-D7) for an unprotected sector. After the completion of the initial sector erase command sequence the sector erase time-out will begin. D3 will remain low until the time-out is complete. Data Polling and Toggle Bit are valid after the initial sector erase command sequence. If Data Polling or the Toggle Bit indicates the device has been written with a valid erase command, D3 may be used to determine if the sector erase timer window is still open. If D3 is high ("1") the internally controlled erase cycle has begun; attempts to write subsequent commands to the device will be ignored until the erase operation is completed as indicated by Data Polling or Toggle Bit. If D3 is low ("0"), the device will accept additional sector erase commands. To ensure the command has been accepted, the software should check the status of D3 prior to and following each subsequent sector erase command. If D3 were high on the second status check, the command may not have been accepted. Aeroflex Circuit Technology D5 D4 D3 8 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 Figure 1 AC Waveforms for Toggle Bit During Embedded Algorithm Operations CE tOEH WE tOES OE Data D0-D7 D6=Toggle D6=Toggle D6 Stop Toggle D0-D7 Valid tOE Figure 2 AC Test Circuit Current Source IOL To Device Under Test CL = 50 pF Parameter Input Pulse Level Input Rise and Fall VZ ~ 1.5 V (Bipolar Supply) Input and Output Timing Reference Output Lead Capacitance Typical 0 – 3.0 5 1.5 50 Units V ns V pF IOH Current Source Notes: 1) VZ is programmable from -2V to +7V. 2) IOL and IOH programmable from 0 to 16 mA. 3) Tester Impedance ZO = 75Ω. 4) VZ is typically the midpoint of VOH and VOL. 5) IOL and IOH are adjusted to simulate a typical resistance load circuit. 6) ATE Tester includes jig capacitance. Aeroflex Circuit Technology 9 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 Figure 3 Programming Algorithm Bus Operations Command Sequence Comments Program Valid Address/Data Sequence Standby Write Read Data Polling to Verify Programming Standby Compare Data Output to Data Expected Start Write Program Command Sequence (See Below) Data Poll Device Increment Address No Last Address ? Yes Programming Complete Program Command Sequence (Address/Command): 5555H/AAH 2AAAH/55H 5555H/A0H Programming Address/Program Data Aeroflex Circuit Technology 10 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 Figure 4 Erase Algorithm Bus Operations Command Sequence Comments Standby Write Erase Read Data Polling to Verify Erasure Standby Compare Output to FFH Start Write Erase Command Sequence (See Below) Data Poll or Toggle Bit Successfully Completed Erasure Completed Chip Erase Command Sequence (Address/Command) Individual Sector/Multiple Sector Erase Command Sequence (Address/Command) 5555H/AAH 5555H/AAH 2AAAH/55H 2AAAH/55H 5555H/80H 5555H/80H 5555H/AAH 5555H/AAH 2AAAH/55H 2AAAH/55H 5555H/10H Sector Address/30H Sector Address/30H Additional Sector Erase Commands are Optional Sector Address/30H Note 1. To Ensure the command has been accepted, the system software should check the status of D3 prior to and following each subsequent sector erase command. If D3 were high on the second status check, the command may not have been accepted. Aeroflex Circuit Technology 11 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 Figure 5 Toggle Bit Algorithm Figure 6 Data Polling Algorithm Start Read Byte D0-D7 Address = VA D6 = Toggle ? Start VA = Byte Address for Programming = Any of the Sector Addresses within the sector being erased during sector erase operation = XXXXH during Chip Erase Read Byte D0-D7 Address = VA No D7 = Data ? No D5 = 1 ? D5 = 1 ? Yes Yes Read Byte D0-D7 Address = VA D6 = Toggle? (Note 1) Yes Read Byte D0-D7 Address = VA D7 = Toggle? (Note 1) No Pass No Fail Yes Pass Fail Note 1. D7 is rechecked even if D5 = "1" because D7 may change simultaneously with D5. Note 1. D6 is rechecked even if D5 = "1" because D6 may stop toggling at the same time as D5 changes to "1". Aeroflex Circuit Technology Yes No Yes No VA = Byte Address for Programming = Any of the Sector Addresses within the sector being erased during sector erase operation = XXXXH during Chip Erase 12 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 Figure 7 AC Waveforms for Read Operations tRC Addresses Addresses Stable tACC CE tDF OE tOE WE tCE tOH High Z Outputs Output Valid High Z Figure 8 Write/Erase/Program Operation, WE Controlled Data Polling Addresses 5555H PA tWC tAS PA tRC tAH CE tGHWL OE tWP tWHWH1 tWPH WE tCE tDF tOE tDH AOH Data D7 PD DOUT tDS tOH 5.0V tCE Notes: 1. PA is the address of the memory location to be programmed. 2. PD is the data to be programmed at byte address. 3. D7 is the 0utput of the complement of the data written to the deviced. 4. Dout is the output of the data written to the device. 5. Figure indicates last two bus cycles of four bus cycle sequence. Aeroflex Circuit Technology 13 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 Figure 9 AC Waveforms Chip/Sector Erase Operations Data Polling tAH 5555H Addresses 2AAAH 5555H 5555H 2AAAH SA tAS CE tGHWL OE tWP WE tCE tWPH tDH AAH Data 55H 80H AAH 55H 10H/30H tDS VCC tVCE Notes: 1. SA is the sector address for sector erase. Figure 10 AC Waveforms for Data Polling During Embedded Algorithm Operations tCH CE tDF tOE OE tOEH tCE WE tOH * D7 D7 High Z D7= Valid Data tWHWH1 or 2 D0-D6 D0–D6 Valid Data D0–D6=Invalid tOE * D7=Valid Data (The device has completed the Embedded operation). Aeroflex Circuit Technology 14 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 Figure 11 Sector Protection Algorithm Start Set Up Sector Address (A16, A15, A14) PLSCNT = 1 OE = VID A9 = VID, CE = VIL Activate WE Pulse Time Out 100µs Increment PLSCNT Power Down OE WE = VIH CE = OE = VIH A9 Should Remain VID Read From Sector Address = SA, A0 = 0, A1 = 1, A6 = 0 No No Data = 01H ? PLSCNT = 25 ? Yes Yes Device Failure Protect Another Sector? Yes No Remove VID from A9 Write Reset Command Sector Protection Complete Aeroflex Circuit Technology 15 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 Figure 12 Sector Unprotect Algorithm Start Set VCC = 5.0 V Protect All Sectors PLSCNT = 1 Set Up Sector Address Unprotected Mode (A12 = A7 = VIH, A6 = VIL) Set VCC = 5.0 V Set OE = CE = A9 = VID Activate WE Pulse Increment PLSCNT Time Out 10ms Set OE = CE = VIL Remove VID from A9 Set VCC = 4.25 V Write Autoselect Command Sequence Setup Sector Address SA0 Set A1 = 1, A0 = 0 Read Data From Device No Increment Sector Address No Data = 00H ? Write Reset Command PLSCNT = 1000 ? Yes Yes Device Failure No Sector Address = SA7 ? Yes Set VCC = 5.0 V Notes: SA0 = Sector Address for initial sector SA7 = Sector Address for last sector Please refer to Table 2 Write Reset Command Sector Unprotect Completed Aeroflex Circuit Technology 16 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 Figure 13 Write/Erase/Program Operation, CE Controlled Data Polling Addresses 5555H PA tWC tAS PA tAH WE tGHEL OE tCP CE tWHWH1 tCPH tWS tDH AOH Data D7 PD DOUT tDS 5.0V Notes: 1. PA is the address of the memory location to be programmed. 2. PD is the data to be programmed at byte address. 3. D7 is the 0utput of the complement of the data written to the device. 4. DOUT is the output of the data written to the device. 5. Figure indicates last two bus cycles of four bus cycle sequence. Aeroflex Circuit Technology 17 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 Pin Numbers & Functions 32 Pins — DIP Package 1 NC 17 I/O3 2 A16 18 I/O4 3 A15 19 I/O5 4 A12 20 I/O6 5\ A7 21 I/O7 6 A6 22 CE 7 A5 23 A10 8 A4 24 OE 9 A3 25 A11 10 A2 26 A9 11 A1 27 A8 12 A0 28 A13 13 I/O0 29 A14 14 I/O1 30 NC 15 I/O2 31 WE 16 VSS 32 VCC Package Outline "P4" — .590" x 1.67" DIP Package 1.623 MAX Pin 32 .165 MAX Pin 1 .604 MAX Pin 1 Identifier .100 TYP .020 .016 TYP .055 .045 .060 .040 TYP .125 MIN .012 .009 .610 .590 All dimensions in inches Aeroflex Circuit Technology 18 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 Pin Numbers & Functions 32 Pins — Flat Package 1 NC 17 I/O3 2 A16 18 I/O4 3 A15 19 I/O5 4 A12 20 I/O6 5 A7 21 I/O7 6 A6 22 CE 7 A5 23 A10 8 A4 24 OE 9 A3 25 A11 10 A2 26 A9 11 A1 27 A8 12 A0 28 A13 13 I/O0 29 A14 14 I/O1 30 NC 15 I/O2 31 WE 16 VSS 32 VCC Package Outline "F6" — 32 Lead, Ceramic Flat Package .830 MAX Pin 17 Pin 32 .415 MAX Pin 16 Pin 1 .400 MIN All dimensions in inches Aeroflex Circuit Technology .125 MAX +.002 .005 -.001 .017 ±.002 .750 (15 spaces at .050) 2 sides 19 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 Pin Numbers & Functions 32 Pins — Flat Package 1 NC 17 I/O3 2 A16 18 I/O4 3 A15 19 I/O5 4 A12 20 I/O6 5 A7 21 I/O7 6 A6 22 CE 7 A5 23 A10 8 A4 24 OE 9 A3 25 A11 10 A2 26 A9 11 A1 27 A8 12 A0 28 A13 13 I/O0 29 A14 14 I/O1 30 NC 15 I/O2 31 WE 16 VSS 32 VCC Package Outline "F7" — 32 Lead, Ceramic Flat Package .132 MAX .006 TYP .830 MAX Base Plane .125 MAX Pin 17 Pin 32 .415 MAX .530 ±.005 .068 TYP .025 TYP Pin 1 .017 ±.002 .750 (15 spaces at .050) 2 sides Pin 16 +.002 .005 -.001 0° / -4° .030 TYP Seating Plane All dimensions in inches Aeroflex Circuit Technology 20 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700 CIRCUIT TECHNOLOGY Ordering Information Model Number DESC Drawing Number Speed Package ACT–F128K8N–150F6Q 5962-9669001HTC* 150 ns Flat Pack ACT–F128K8N–120F6Q 5962-9669002HTC* 120 ns Flat Pack ACT–F128K8N–090F6Q 5962-9669003HTC* 90 ns Flat Pack ACT–F128K8N–070F6Q 5962-9669004HTC* 70 ns Flat Pack ACT–F128K8N–060F6Q 5962-9669005HTC* 60 ns Flat Pack ACT–F128K8N–150F7Q 5962-9669001HUC* 150 ns Flat Pack (Formed) ACT–F128K8N–120F7Q 5962-9669002HUC* 120 ns Flat Pack (Formed) ACT–F128K8N–090F7Q 5962-9669003HUC* 90 ns Flat Pack (Formed) ACT–F128K8N–070F7Q 5962-9669004HUC* 70 ns Flat Pack (Formed) ACT–F128K8N–060F7Q 5962-9669005HUC* 60 ns Flat Pack (Formed) ACT–F128K8N–150P4Q 5962-9669001HYC* 150 ns DIP Pack ACT–F128K8N–120P4Q 5962-9669002HYC* 120 ns DIP Pack ACT–F128K8N–090P4Q 5962-9669003HYC* 90 ns DIP Pack ACT–F128K8N–070P4Q 5962-9669004HYC* 70 ns DIP Pack ACT–F128K8N–060P4Q 5962-9669005HYC* 60 ns DIP Pack * Pending Part Number Breakdown ACT– F 128 8 N– 090 F6 Q Aeroflex Circuit Technology Memory Type Screening F = FLASH EEPROM C = Commercial Temp, 0°C to +70°C I = Industrial Temp, -40°C to +85°C T = Military Temp, -55°C to +125°C M = Military Temp, -55°C to +125°C, Screening * Q = MIL-PRF-38534 Compliant / SMD Package Type & Size Memory Depth Memory Width, Bits Options Surface Mount Packages F6 = .82" x .40" 32 Lead FP Unformed F7 = .82" x .40" 32 Lead FP Formed N = None Memory Speed, ns Thru-Hole Packages P4 = 32 Pin DIP * Screened to the individual test methods of MIL-STD-883 Specifications subject to change without notice. Telephone: (516) 694-6700 FAX: (516) 694-6715 Toll Free Inquiries: 1-(800) 843-1553 Aeroflex Circuit Technology 35 South Service Road Plainview New York 11830 Aeroflex Circuit Technology 21 SCD1676 REV A 5/6/98 Plainview NY (516) 694-6700